1 About the FAN-8056-2U-G6 fan module

IMPORTANT

IMPORTANT:

·     The information in this document might differ from your product if it contains custom configuration options or features.

·     The figures in this document are for illustration only and might differ from your product in appearance or structure, such as color and label form.

·     To obtain fan modules supported by a server, use the component compatibility lookup tool at http://www.h3c.com/en/home/qr/default.htm?id=66.

·     The model name of a hardware option in this document might differ slightly from its model name label. A model name label might add a prefix or suffix to the hardware-coded model name. For example, the FAN-8056-2U-G6 fan module model represents fan module labels including UN-FAN-8056-2U-G6 that has a prefix.

 

The FAN-8056-2U-G6 fan has two rotors, one that has five vanes at the air inlet, and the other that has four vanes at the air outlet. When the fan is operating correctly, the two rotors are reversed in direction to form counter-rotation for sufficient wind pressure. The fan module is hot swappable, and provides fast heat dissipation and high speed.

Figure1-1 FAN-8056-2U-G6 fan module

 

2 Key features

Automatic speed adjustment

The fan uses pulse width modulation (PWM) to adjust fan speed quickly, accurately, and stably as instructed by the system. When the temperature of the ambient environment or an internal component is high, the fan speed increases to help fast heat dissipation. When the temperature of the ambient environment or an internal component is low, the fan speed decreases to save energy.

Hot swapping

The fan module is hot swappable, improving system maintainability.

Locked rotor protection

This feature protects the fan from being damaged for up to 96 hours if the rotor of the fan operating under normal voltage stops rotating because of a foreign object.

Polarity protection

If the polarity of the input voltage does not match the polarity of the fan, the fan cannot operate correctly but will not be damaged.

3 Technical specifications

Table3-1 Technical specifications

Item

Specifications

Number of fans

1

Number of rotors

2

Dimensions (H × W × D)

80 × 80 × 56 mm (3.15 × 3.15 × 2.20 in)

Rotation direction

Facing the air inlet side:

·     The rotor at the air inlet rotates counterclockwise.

·     The rotor at the air outlet rotates clockwise.

Maximum fan speed

·     Rotor at the air inlet: 15000 RPM

·     Rotor at the air outlet: 13000 RPM

Maximum airflow

128.1 CFM

Maximum power consumption

76.24 W

Operating voltage

12 V (10.8 V to 13.2 V)

Operating temperature

–10°C to +70°C (14°F to 158°F)

Operating humidity

5% to 90%, noncondensing

Storage temperature

–40°C to +70°C (–40°F to +158°F)

Storage humidity

5% to 95%, power-off, noncondensing

 

 

NOTE:

Facing the air inlet side*: The label () on the top of the fan module indicates the direction of the airflow, with the arrow end indicating the outlet side and the tail end indicating the inlet side.

 

4 Installing and removing the fan module

For information about installing and removing the fan module on a device, see the user guide for the device.

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Intelligent Storage
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
  • Technical Blogs
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网