H3C IE4300-12P-AC & IE4300-12P-PWR Industrial Switches Hardware Information and Specifications-6W103

HomeSupportSwitchesIE4300-12P-AC & IE4300-12P-PWR Industrial SwitchesProduct LiteratureHardware Information & SpecificationsH3C IE4300-12P-AC & IE4300-12P-PWR Industrial Switches Hardware Information and Specifications-6W103

01-Hardware Information and Specifications


1 Product models and technical specifications

Product models

This document is applicable to the following industrial switch models:

·     IE4300-12P-AC

·     IE4300-12P-PWR

Technical specifications

Table1-1 Technical specifications

Item

IE4300-12P-AC

IE4300-12P-PWR

Dimensions (H × W × D)

150 × 44 × 130 mm (5.91 × 1.73 × 5.12 in)

150 × 44 × 130 mm (5.91 × 1.73 × 5.12 in)

Weight

≤ 1 kg (2.20 lb)

≤ 1 kg (2.20 lb)

Console port

1

1

10/100/1000BASE-T autosensing Ethernet port

8

8 (PoE capable)

SFP port

4

4

Alarm input (DI)

The system detects exceptions of the connected device based on the input voltage changes on the alarm input connection.

·     State:

¡     1: +13 to +30 V

¡     0: 30 to + 3 V

·     Max. input current: 8 mA

Alarm output (DO)

Uses a relay for output, with a current carrying capacity of 1A @ 24 VDC

The relay outputs alarms by opening or closing the contact.

DIP switch

Supported. For more information, see "DIP switches."

Input voltage

·     Rated voltage range: 100 to 240 VAC @ 50 or 60 Hz

·     Max voltage range: 85 to 264 VAC @ 45 to 65 Hz

·     Rated voltage range: 54 to 57 VDC

·     Max voltage range: 54 to 57 VDC

Max. PoE power per port

N/A

30 W

Total PoE power

N/A

125 W

Minimum power consumption

7 W

·     Single DC input: 11 W

·     Dual DC inputs: 14 W

Maximum power consumption (including PoE power consumption)

12 W

·     Single DC input: 141 W

·     Dual DC inputs: 144 W

Melting current of power supply fuse

6.3 A/250 V

8 A/125 V

Cooling system

Natural cooling without fan trays

Operating altitude

–60 to +5000 m (–196.85 to +16404.20 ft)

The maximum acceptable temperature decreases by 0.33°C (32.59°F) for every 100 m (328.084 ft) increase in altitude from 0 m (0 ft).

Operating humidity

5% RH to 95% RH, noncondensing

Ingress protection rating

IP41

Pollution degree

Degree 2.

The switch is for indoor use only.

Safety compliance

UL 61010, UL 60950-1, EN 60950-1, IEC 60950-1, GB4943, IEC 62368-1, UL 62368-1, EN 62368-1

 

DIP switches

The switch provides DIP switches to enable or disable corresponding features.

Table1-2 DIP switch descriptions

Item

Description

Applicable switch models

IE4300-12P-AC

IE4300-12P-PWR

DIP switch 1

Enables or disables flow control on the ports

DIP switch 2

Enables or disables broadcast suppression on the ports

DIP switch 3

Enables or disables link aggregation on ports 9 and 10

DIP switch 4

Enables or disables RRPP on ports 11 and 12

 

When DIP switch 1 is on, flow control is enabled on all ports. When DIP switch 1 is off, the status of the flow control feature depends on the configuration. For more information about flow control, see Ethernet interface configurations in the configuration guides for the switch.

When DIP switch 2 is on, broadcast suppression is enabled on all ports. When DIP switch 2 is off, the status of the broadcast suppression feature depends on the configuration. For more information about broadcast suppression, see Ethernet interface configurations in the configuration guides for the switch.

When DIP switch 3 is on, the system creates Layer 2 aggregation group 1 and adds the two uplink Ethernet ports to the group. When DIP switch 3 is off, the status of the link aggregation feature depends on the configuration. For more information about Layer 2 link aggregation, see Ethernet link aggregation configurations in the configuration guides for the switch.

When DIP switch 4 is on, RRPP is enabled. When DIP switch 4 is off, the status of the RRPP feature depends on the configuration. For more information, see RRPP configurations in the configuration guides for the switch.

2 Chassis views

IE4300-12P-AC

Figure2-1 Front panel

(1) Diag LED

(2) SFP port

(3) 10/100/1000BASE-T autosensing Ethernet port

(4) 10/100/1000BASE-T autosensing Ethernet port LEDs

(5) SFP port LED

(6) Alarm LED

(7) Power status LED (PWR)

 

Figure2-2 Top panel

(1) Alarm input connection (DI)

(2) Alarm output connection (DO)

(3) AC power receptacle

(4) DIP switch

(5) Console port

(6) Grounding screw

 

CAUTION

CAUTION:

The IE4300-12P-AC switch has a caution label on the top panel, indicating that no alarm cable and power cord are provided with the switch. Use only a copper alarm cable and power cord for the switch.

 

Figure2-3 Rear panel

(1) DIN rail mounting bracket

 

IE4300-12P-PWR

Figure2-4 Front panel

(1) PWR2 status LED

(2) Diag LED

(3) SFP port

(4) 10/100/1000BASE-T autosensing Ethernet port

(5) 10/100/1000BASE-T autosensing Ethernet port LEDs

(6) SFP port LED

(7) Alarm LED

(8) PWR1 status LED

 

Figure2-5 Top panel

(1) Alarm input connection (DI)

(2) Alarm output connection (DO)

(3) DC power receptacle 2 (PWR2)

(4) DC power receptacle 1 (PWR1)

(5) DIP switch

(6) Console port

(7) Grounding screw

 

CAUTION

CAUTION:

The IE4300-12P-PWR switch has a caution label on the top panel, indicating that no alarm cable and power cord are provided with the switch. Use only a copper alarm cable and power cord for the switch.

 

Figure2-6 Rear panel

(1) DIN rail mounting bracket

 

 


3 Ports and LEDs

Ports

Console port

Table3-1 Console port specifications

Item

Specification

Connector type

RJ-45

Compliant standard

EIA/TIA-232

Transmission baud rate

9600 bps (default) to 115200 bps

Services

·     Provides connection to an ASCII terminal.

·     Provides connection to the serial port of a local terminal (PC for example) running a terminal emulation program.

 

10/100/1000BASE-T autosensing Ethernet port

Table3-2 10/100/1000BASE-T autosensing Ethernet port specifications

Item

Specification

Connector type

RJ-45

Rate and duplex mode

·     10 Mbps, half/full-duplex

·     100 Mbps, half/full-duplex

·     1000 Mbps, full-duplex

Auto MDI/MDI-X

Supported

Transmission medium and max transmission distance

100 m (328.08 ft) over category-5 or above twisted pair cable

Compliant standard

IEEE 802.3i, 802.3u, 802.3ab

 

SFP port

Table3-3 GE SFP transceiver modules and cables available for the SFP ports

GE SFP transceiver module and cable

Central wavelength (nm)

Connector

Cable/Fiber type and diameter (µm)

Modal bandwidth (MHz × km)

Max transmission distance

SFP copper transceiver module

SFP-GE-T

N/A

RJ-45

Twisted pair cable

N/A

100 m (328.08 ft)

SFP-GE-T-D

N/A

RJ-45

Twisted pair cable

N/A

100 m (328.08 ft)

SFP fiber transceiver module

SFP-GE-SX-MM850-A

850

LC

Multi-mode, 50/125

500

550 m (1804.46 ft)

400

500 m (1640.42 ft)

Multi-mode, 62.5/125

200

275 m (902.23 ft)

160

220 m (721.78 ft)

SFP-GE-SX-MM850-D

850

LC

Multi-mode, 50/125

500

550 m (1804.46 ft)

400

500 m (1640.42 ft)

Multi-mode, 62.5/125

200

275 m (902.23 ft)

160

220 m (721.78 ft)

SFP-GE-SX-MM850-S

850

LC

Multi-mode, 50/125

500

550 m (1804.46 ft)

400

500 m (1640.42 ft)

Multi-mode, 62.5/125

200

275 m (902.23 ft)

160

220 m (721.78 ft)

SFP-GE-LX-SM1310-A

1310

LC

Single-mode, 9/125

N/A

10 km (6.21 miles)

Multi-mode, 50/125

500 or 400

550 m (1804.46 ft)

Multi-mode, 62.5/125

500

550 m (1804.46 ft)

SFP-GE-LX-SM1310-D

1310

LC

Single-mode, 9/125

N/A

10 km (6.21 miles)

SFP-GE-LX-SM1310-S

1310

LC

Single-mode, 9/125

N/A

10 km (6.21 miles)

SFP-GE-LX10-SM1310

1310

LC

Single-mode, 9/125

N/A

10 km (6.21 miles)

SFP-GE-LH40-SM1310

1310

LC

Single-mode, 9/125

N/A

40 km (24.86 miles)

SFP-GE-LH40-SM1310-D

1310

LC

Single-mode, 9/125

N/A

40 km (24.86 miles)

SFP-GE-LH40-SM1550

1550

LC

Single-mode, 9/125

N/A

40 km (24.86 miles)

SFP-GE-LH80-SM1550

1550

LC

Single-mode, 9/125

N/A

80 km (49.71 miles)

SFP-GE-LH80-SM1550-D

1550

LC

Single-mode, 9/125

N/A

80 km (49.71 miles)

SFP-GE-LH100-SM1550

1550

LC

Single-mode, 9/125

N/A

100 km (62.14 miles)

SFP-GE-LX-SM1310-BIDI

TX: 1310

RX: 1490

LC

Single-mode, 9/125

N/A

10 km (6.21 miles)

SFP-GE-LX-SM1490-BIDI

TX: 1490

RX: 1310

LC

Single-mode, 9/125

N/A

10 km (6.21 miles)

SFP-GE-LH40-SM1310-BIDI

TX: 1310

RX: 1550

LC

Single-mode, 9/125

N/A

40 km (24.86 miles)

SFP-GE-LH40-SM1550-BIDI

TX: 1550

RX: 1310

LC

Single-mode, 9/125

N/A

40 km (24.86 miles)

SFP-GE-LH70-SM1490-BIDI

TX: 1490

RX: 1550

LC

Single-mode, 9/125

N/A

70 mm (2.76 in)

SFP-GE-LH70-SM1550-BIDI

TX: 1550

RX: 1490

LC

Single-mode, 9/125

N/A

70 mm (2.76 in)

SFP cable

SFP-STACK-Kit

N/A

1.5 m (4.92 ft)

 

IMPORTANT

IMPORTANT:

The SFP-GE-LX-SM1310-BIDI and SFP-GE-LX-SM1490-BIDI transceiver modules, the SFP-GE-LH40-SM1310-BIDI and SFP-GE-LH40-SM1550-BIDI transceiver modules, and the SFP-GE-LH70-SM1490-BIDI and SFP-GE-LH70-SM1550-BIDI transceiver modules must be used in pairs. For example, if one end uses an SFP-GE-LX-SM1310-BIDI transceiver module, the other end must use an SFP-GE-LX-SM1490-BIDI transceiver module.

 

 

NOTE:

·     As a best practice, use H3C transceiver modules and cables for the switch.

·     The H3C transceiver modules and cables are subject to change over time. For the most recent list of H3C transceiver modules and cables, contact H3C marketing staff or technical support.

·     For the specifications of H3C transceiver modules and cables, see H3C Transceiver Modules User Guide.

 

LEDs

Power status LED

An IE4300-12P-AC switch provides an AC power receptacle and uses a power status LED to indicate the power input status. Table3-4 provides the description of the power status LED on the IE4300-12P-AC switch.

An IE4300-12P-PWR switch provides two DC power receptacles and uses a power status LED for each receptacle to indicate the power input status. Table3-5 provides the description of the power status LEDs on the IE4300-12P-PWR switch.

Table3-4 Description of the power status LED on the IE4300-12P-AC switch

LED mark

Status

Description

PWR

Steady green

Normal AC power input

Off

Abnormal or no AC power input

 

Table3-5 Description of the power status LEDs on the IE4300-12P-PWR switch

LED mark

Status

Description

PWR

Steady green

Normal DC power input

Off

Abnormal or no DC power input

 

Alarm LED

The switch provides an alarm input connection on the top panel and can detect changes of the digital input voltage. When the digital input voltage exceeds the acceptable range, the system uses the alarm LED to indicate the exception.

Table3-6 Alarm LED description

LED mark

Status

Description

Alarm

Steady red

A digital input exception has been detected.

Off

No exception has been detected.

 

Diag LED

The switch provides a Diag LED on the front panel to indicate the system operating status.

Table3-7 Diag LED description

LED mark

Status

Description

Diag

Steady red

The switch has failed the POST, or an alarm condition such as MAC chip overtemperature has occurred.

Off

The switch has passed the POST and is operating correctly.

 

SFP port LED

Table3-8 SFP port LED description

Status

Description

Steady green

A link is present on the port.

Flashing green

The port is sending or receiving data.

Off

No link is present on the port.

 

10/100/1000BASE-T autosensing Ethernet port LED (IE4300-12P-AC)

Table3-9 10/100/1000BASE-T autosensing Ethernet port LED description

Green LED

Yellow LED

Description

Steady on

Off

A link is present on the port and the port is operating at 1000 Mbps.

Flashing

Off

The port is sending or receiving data at 1000 Mbps.

Off

Steady on

A link is present on the port and the port is operating at 10/100 Mbps.

Off

Flashing

The port is sending or receiving data at 10/100 Mbps.

Off

Off

No link is present on the port or a link failure has occurred.

 

 

NOTE:

For the green and yellow LEDs for a 10/100/1000BASE-T autosensing Ethernet port, only one of them is on or flashing at a time.

 

10/100/1000BASE-T autosensing Ethernet port LED (IE4300-12P-PWR)

An IE4300-12P-PWR switch provides a green and a yellow LED for each 10/100/1000BASE-T autosensing Ethernet port. The green and yellow LEDs indicate the data rate and PoE power supply status of the port, respectively.

Table3-10 10/100/1000BASE-T autosensing Ethernet port LED description

LED

Status

Description

Green LED

Steady on

A link is present on the port and the port is operating at 10/100/1000 Mbps.

Flashing

The port is sending or receiving data at 10/100/1000 Mbps.

Off

No link is present on the port, or a link failure has occurred.

Yellow LED

Steady on

A PD is connected to the port and the port is supplying power to the PD correctly.

Flashing

A PD is connected to the port but the port is not supplying power correctly to the PD.

Off

No PD is connected to the port, or PoE is not enabled on the port.

 

不同款型规格的资料略有差异, 详细信息请向具体销售和400咨询。 H3C保留在没有任何通知或提示的情况下对资料内容进行修改的权利!
  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become a Partner
  • Partner Resources
  • Partner Business Management
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网