Contents
Common Ethernet interface commands
display interface split-capable
priority-flow-control (Ethernet interface view)
priority-flow-control (system view)
priority-flow-control deadlock auto-recover action
priority-flow-control deadlock auto-recover cos
priority-flow-control deadlock cos
priority-flow-control deadlock enable
priority-flow-control deadlock precision
priority-flow-control deadlock recover
priority-flow-control deadlock recover-mode
priority-flow-control deadlock threshold
priority-flow-control early-warning inpps
priority-flow-control early-warning outpps
priority-flow-control no-drop dot1p (Ethernet interface view)
priority-flow-control no-drop dot1p (system view)
snmp-agent trap enable ifmonitor
Layer 2 Ethernet interface commands
Layer 3 Ethernet interface or subinterface commands
Ethernet interface commands
Common Ethernet interface commands
bandwidth
Use bandwidth to set the expected bandwidth of an interface.
Use undo bandwidth to restore the default.
Syntax
bandwidth bandwidth-value
undo bandwidth
Default
The expected bandwidth (in kbps) is the interface baud rate divided by 1000.
Views
Ethernet interface view
Ethernet subinterface view
Predefined user roles
network-admin
Parameters
bandwidth-value: Specifies the expected bandwidth in the range of 1 to 400000000 kbps.
Usage guidelines
The expected bandwidth is an informational parameter used only by higher-layer protocols for calculation. You cannot adjust the actual bandwidth of an interface by using this command.
Examples
# Set the expected bandwidth of Ten-GigabitEthernet 1/0/1 to 1000 kbps.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] bandwidth 1000
# Set the expected bandwidth of Ten-GigabitEthernet 1/0/1.1 to 1000 kbps.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1.1
[Sysname-Ten-GigabitEthernet1/0/1.1] bandwidth 1000
Related commands
speed
broadcast-suppression
Use broadcast-suppression to enable broadcast suppression and set the broadcast suppression threshold.
Use undo broadcast-suppression to disable broadcast suppression.
Syntax
broadcast-suppression { ratio | pps max-pps | kbps max-kbps }
undo broadcast-suppression
Default
Ethernet interfaces do not suppress broadcast traffic.
Views
Ethernet interface view
Predefined user roles
network-admin
Parameters
ratio: Sets the broadcast suppression threshold as a percentage of the interface bandwidth. The value range for this argument is 0 to 100. A smaller value means that less broadcast traffic is allowed to pass through.
pps max-pps: Specifies the maximum number of broadcast packets that the interface can forward per second. The value range for the max-pps argument (in pps) is 0 to 1.4881 × the interface bandwidth.
kbps max-kbps: Specifies the maximum number of kilobits of broadcast traffic that the Ethernet interface can forward per second. The value range for this argument (in kbps) is 0 to the interface bandwidth.
Usage guidelines
The broadcast storm suppression features limits the size of broadcast traffic to a threshold on an interface. When the broadcast traffic on the interface exceeds this threshold, the system drops packets until the traffic drops below this threshold.
Both the storm-constrain command and the broadcast-suppression command can suppress broadcast storms on a port. The broadcast-suppression command uses the chip to physically suppress broadcast traffic. It has less influence on the device performance than the storm-constrain command, which uses software to suppress broadcast traffic.
For the traffic suppression result to be determined, do not configure both the storm-constrain broadcast command and the broadcast-suppression command on an interface.
When you configure the suppression threshold in kbps, the actual suppression threshold might be different from the configured one as follows:
· If the configured value is smaller than 64, the value of 64 takes effect.
· If the configured value is greater than 64 but not an integer multiple of 64, the integer multiple of 64 that is greater than and closest to the configured value takes effect.
For the suppression threshold that takes effect, see the prompt on the device.
Examples
# Set the broadcast suppression threshold to 10000 kbps on Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] broadcast-suppression kbps 10000
The actual value is 10048 on port Ten-GigabitEthernet1/0/1 currently.
The output shows that the value that takes effect is 10048 kbps (157 times of 64), because the chip only supports step 64.
Related commands
multicast-suppression
unicast-suppression
dampening
Use dampening to enable the device to dampen an interface when the interface is flapping.
Use undo dampening to restore the default.
Syntax
dampening [ half-life reuse suppress max-suppress-time ]
undo dampening
Default
Interface dampening is disabled on Ethernet interfaces.
Views
Ethernet interface view
Predefined user roles
network-admin
Parameters
half-life: Specifies the amount of time after which a penalty is decreased, in the range of 1 to 120 seconds. The default value is 54 seconds.
reuse: Specifies the reuse threshold in the range of 200 to 20000. The default value is 750. The reuse threshold must be less than the suppression threshold.
suppress: Specifies the suppression threshold in the range of 200 to 20000. The default value is 2000.
max-suppress-time: Specifies the maximum amount of time the interface can be dampened, in the range of 1 to 255 seconds. The default value is 162 seconds (three times the half-life timer).
Usage guidelines
This command and the link-delay command cannot be both configured on an interface.
This command does not take effect on the administratively down events. When you execute the shutdown command, the penalty restores to 0, and the interface reports the down event to the higher layer protocols.
Do not enable the dampening function on an interface with RRPP, MSTP, or Smart Link enabled.
After an interface in down state is dampened, the interface state displayed through the display interface command is always down.
Examples
# Enable interface dampening on Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] dampening
# Enable interface dampening on Ten-GigabitEthernet 1/0/1, and set the following parameters:
· Half life time to 2 seconds.
· Reuse value to 800.
· Suppression threshold to 3000.
· Maximum suppression interval to 5 seconds.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] dampening 2 800 3000 5
Related commands
display interface
link-delay
default
Use default to restore the default settings for an interface.
Syntax
default
Views
Ethernet interface view
Ethernet subinterface view
Predefined user roles
network-admin
Usage guidelines
CAUTION: The default command might interrupt ongoing network services. Make sure you are fully aware of the impacts of this command when you use it in a live network. |
This command might fail to restore the default settings for some commands because of command dependencies or system restrictions. You can use the display this command in interface view to identify these commands, and use their undo forms or follow the command reference to restore their default settings. If your restoration attempt still fails, follow the error message instructions to solve the problem.
Examples
# Restore the default settings for Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] default
# Restore the default settings for Ten-GigabitEthernet 1/0/1.1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1.1
[Sysname-Ten-GigabitEthernet1/0/1.1] default
description
Use description to configure the description of an interface.
Use undo description to restore the default.
Syntax
description text
undo description
Default
The description of an interface is the interface name plus Interface (for example, Ten-GigabitEthernet1/0/1 Interface).
Views
Ethernet interface view
Ethernet subinterface view
Predefined user roles
network-admin
Parameters
text: Specifies the interface description, a case-sensitive string of 1 to 255 characters.
Examples
# Set the description of Ten-GigabitEthernet 1/0/1 to lan-interface.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] description lan-interface
# Set the description of Ten-GigabitEthernet 1/0/1.1 to subinterface1/0/1.1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1.1
[Sysname-Ten-GigabitEthernet1/0/1.1] description subinterface1/0/1.1
display counters
Use display counters to display interface traffic statistics.
Syntax
display counters { inbound | outbound } interface [ interface-type [ interface-number ] ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
inbound: Displays inbound traffic statistics.
outbound: Displays outbound traffic statistics.
interface-type: Specifies an interface type.
interface-number: Specifies an interface number.
Usage guidelines
To clear the Ethernet interface traffic statistics, use the reset counters interface command.
If you do not specify an interface type, this command displays traffic statistics for all interfaces that have traffic counters.
If you specify an interface type but do not specify an interface number, this command displays traffic statistics for all interfaces of the specified type.
If you specify an interface type and an interface, this command displays traffic statistics for the specified interface.
Examples
# Display inbound traffic statistics for all GigabitEthernet interfaces.
<Sysname> display counters inbound interface gigabitethernet
Interface Total(pkt) Broadcast(pkt) Multicast(pkt) Err(pkt)
XGE1/0/1 100 100 0 0
XGE1/0/2 Overflow Overflow Overflow Overflow
Overflow: More than 14 digits (7 digits for column "Err").
--: Not supported.
Table 1 Command output
Field |
Description |
Interface |
Abbreviated interface name. |
Total(pkt) |
Total number of packets received or sent through the interface. |
Broadcast(pkt) |
Total number of broadcast packets received or sent through the interface. |
Multicast(pkt) |
Total number of multicast packets received or sent through the interface. |
Err(pkt) |
Total number of error packets received or sent through the interface. |
Overflow: More than 14 digits (7 digits for column "Err") |
The command displays Overflow when any of the following conditions exist: · The data length of an Err field value is greater than 7 decimal digits. · The data length of a non-Err field value is greater than 14 decimal digits. |
--: Not supported |
The statistical item is not supported. |
Related commands
reset counters interface
display counters rate
Use display counters rate to display traffic rate statistics for interfaces in up state within the most recent statistics polling interval.
Syntax
display counters rate [ inbound | outbound ] interface [ interface-type [ interface-number ] ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
inbound: Displays inbound traffic rate statistics.
outbound: Displays outbound traffic rate statistics.
interface-type: Specifies an interface type.
interface-number: Specifies an interface number.
Usage guidelines
If you do not specify the inbound or outbound keyword, this command displays both the inbound and outbound traffic rate statistics for interfaces in up state within the most recent statistics polling interval.
If you do not specify an interface type, this command displays traffic rate statistics for all up interfaces that have traffic counters.
If you specify an interface type but do not specify an interface number or subinterface number, this command displays traffic rate statistics for all up interfaces of the specified type.
If you specify an interface type and an interface or subinterface number, this command displays traffic rate statistics for the specified interface or subinterface.
If an interface that you specify is always down for the most recent statistics polling interval, the system prompts that the interface does not support the command.
The statistics polling interval varies by device model:
· On a device that does not support the flow-interval command, the statistics polling interval is 5 minutes.
· On a device that supports the flow-interval command, you can use the flow-interval command to set the statistics polling interval.
Examples
# Display the inbound and outbound traffic rate statistics for Ten-GigabitEthernet 1/0/1.
<Sysname> display counters rate interface ten-gigabitethernet 1/0/1
Usage: Bandwidth utilization in percentage
Interface InUsage(%) InTotal(pps) OutUsage(%) OutTotal(pps)
XGE1/0/1 0 0 0 0
Overflow: More than 14 digits.
--: Not supported.
# Display the inbound traffic rate statistics for all GigabitEthernet interfaces.
<Sysname> display counters rate inbound interface gigabitethernet
Usage: Bandwidth utilization in percentage
Interface Usage(%) Total(pps) Broadcast(pps) Multicast(pps)
XGE1/0/1 3 200 100 100
Overflow: More than 14 digits.
--: Not supported.
Table 2 Command output
Field |
Description |
Interface |
Abbreviated interface name. |
Usage(%) |
Bandwidth usage (in percentage) of the interface within the most recent statistics polling interval. |
Total(pps) |
Average receiving or sending rate (in pps) for all packets within the most recent statistics polling interval. |
InUsage(%) |
Bandwidth usage (in percentage) of all inbound packets within the most recent statistics polling interval. When the usage is smaller than 1%, 1% is displayed. |
InTotal(pps) |
Average receiving rate (in pps) for all packets within the most recent statistics polling interval. |
OutUsage(%) |
Bandwidth usage (in percentage) of all outbound packets within the most recent statistics polling interval. When the usage is smaller than 1%, 1% is displayed. |
OutTotal(pps) |
Average sending rate (in pps) for all packets within the most recent statistics polling interval. |
Broadcast(pps) |
Average receiving or sending rate (in pps) for broadcast packets within the most recent statistics polling interval. |
Multicast(pps) |
Average receiving or sending rate (in pps) for multicast packets within the most recent statistics polling interval. |
Overflow: more than 14 decimal digits |
The command displays Overflow if the data length of a statistical item is greater than 14 decimal digits. |
--: not supported |
The statistical item is not supported. |
Related commands
flow-interval
reset counters interface
display ethernet statistics
Use display ethernet statistics to display the Ethernet module statistics.
Syntax
display ethernet statistics slot slot-number
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
slot slot-number: Specifies the slot number of the device, which is fixed at 1.
Examples
# Display the Ethernet module statistics for the specified slot.
<Sysname> display ethernet statistics slot 1
ETH receive packet statistics:
Totalnum : 10447 ETHIINum : 4459
SNAPNum : 0 RAWNum : 0
LLCNum : 0 UnknownNum : 0
ForwardNum : 4459 ARP : 0
MPLS : 0 ISIS : 0
ISIS2 : 0 IP : 0
IPV6 : 0
ETH receive error statistics:
NullPoint : 0 ErrIfindex : 0
ErrIfcb : 0 IfShut : 0
ErrAnalyse : 5988 ErrSrcMAC : 5988
ErrHdrLen : 0
ETH send packet statistics:
L3OutNum : 211 VLANOutNum : 0
FastOutNum : 155 L2OutNum : 0
ETH send error statistics:
MbufRelayNum : 0 NullMbuf : 0
ErrAdjFwd : 0 ErrPrepend : 0
ErrHdrLen : 0 ErrPad : 0
ErrQoSTrs : 0 ErrVLANTrs : 0
ErrEncap : 0 ErrTagVLAN : 0
IfShut : 0 IfErr : 0
Table 3 Output description
Field |
Description |
ETH receive packet statistics |
Statistics about the Ethernet packets received by the Ethernet module: · Totalnum—Total number of received packets. · ETHIINum—Number of packets encapsulated by using Ethernet II. · SNAPNum—Number of packets encapsulated by using SNAP. · RAWNum—Number of packets encapsulated by using RAW. · LLCNum—Number of packets encapsulated by using LLC. · UnknownNum—Number of packets encapsulated by using unknown methods. · ForwardNum—Number of packets forwarded at Layer 2 or sent to the CPU. · ARP—Number of ARP packets. · MPLS—Number of MPLS packets. · ISIS—Number of IS-IS packets. · ISIS2—Number of large 802.3/802.2 frames encapsulated by using IS-IS. · IP—Number of IP packets. · IPv6—Number of IPv6 packets. |
ETH receive error statistics |
Statistics about the error Ethernet packets in the inbound direction on the Ethernet module. Errors might be included in packets or occur during the receiving process. The items include: · NullPoint—Number of packets that include null pointers. · ErrIfindex—Number of packets that include incorrect interface indexes. · ErrIfcb—Number of packets that include incorrect interface control blocks. · IfShut—Number of packets that are being received when the interface is shut down. · ErrAnalyse—Number of packets that include packet parsing errors. · ErrSrcMAC—Number of packets that include incorrect source MAC addresses. · ErrHdrLen—Number of packets that include header length errors. |
ETH send packet statistics |
Statistics about the Ethernet packets sent by the Ethernet module: · L3OutNum—Number of packets sent out of Layer 3 Ethernet interfaces. · VLANOutNum—Number of packets sent out of VLAN interfaces. · FastOutNum—Number of packets fast forwarded. · L2OutNum—Number of packets sent out of Layer 2 Ethernet interfaces. · MbufRelayNum—Number of packets transparently sent. |
ETH send error statistics |
Statistics about the error Ethernet packets in the outbound direction on the Ethernet module: · NullMbuf—Number of packets with null pointers. · ErrAdjFwd—Number of packets with adjacency table errors. · ErrPrepend—Number of packets with extension errors. · ErrHdrLen—Number of packets with header length errors. · ErrPad—Number of packets with padding errors. · ErrQoSTrs—Number of packets that failed to be sent by QoS. · ErrVLANTrs—Number of packets that failed to be sent in VLANs. · ErrEncap—Number of packets that failed to be sent due to link header encapsulation failures. · ErrTagVLAN—Number of packets that failed to be sent due to VLAN tag encapsulation failures. · IfShut—Number of packets that are being sent when the interface is shut down. · IfErr—Number of packets with incorrect outgoing interfaces. |
Related commands
reset ethernet statistics
display interface
Use display interface to display interface information.
Syntax
display interface [ interface-type [ interface-number | interface-number.subnumber ] ] [ brief [ description | down ] ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
interface-type: Specifies an interface type.
interface-number: Specifies an interface number.
interface-number.subnumber: Specifies a subinterface number. The interface-number argument is an interface number. The subnumber argument is the number of a subinterface created under the interface. The value range for the subnumber argument is 1 to 4094.
brief: Displays brief interface information. If you do not specify this keyword, the command displays detailed interface information.
description: Displays complete interface descriptions. If you do not specify this keyword, the command displays only the first 27 characters of each interface description.
down: Displays information about interfaces in down state and the causes. If you do not specify this keyword, the command displays information about interfaces in all states.
Usage guidelines
If you specify an interface type but do not specify an interface number or subinterface number, this command displays information about all interfaces of the specified type.
Examples
# Display information about Layer 3 interface Ten-GigabitEthernet 1/0/1.
<Sysname> display interface ten-gigabitethernet 1/0/1
Ten-GigabitEthernet1/0/1
Current state: Administratively DOWN
Line protocol state: DOWN
Description: Ten-GigabitEthernet1/0/1 Interface
Bandwidth: 1000000 kbps
Maximum transmission unit: 1500
Allow jumbo frames to pass
Broadcast max-ratio: 100%
Multicast max-ratio: 100%
Unicast max-ratio: 100%
Internet protocol processing: Disabled
IP packet frame type: Ethernet II, hardware address: 3822-d666-bd0c
IPv6 packet frame type: Ethernet II, hardware address: 3822-d666-bd0c
Flow-control is not enabled
Loopback is not set
Media type is twisted pair, port hardware type is 1000_BASE_T
Port priority: 2
Unknown-speed mode, unknown-duplex mode
Last link flapping: 6 hours 39 minutes 28 seconds
Last clearing of counters: Never
Current system time: 2017-10-27 15:10:03
Last time when physical state changed to up:-
Last time when physical state changed to down: 2017-10-27 14:56:38
Last 300 seconds input: 0 packets/sec 0 bytes/sec 0 bits/sec 0.00%
Last 300 seconds output: 0 packets/sec 0 bytes/sec 0 bits/sec 0.00%
Input (total): 0 packets, 0 bytes
0 unicasts, 0 broadcasts, 0 multicasts, - pauses
Input (normal): 0 packets, 0 bytes
0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses
Input: 0 input errors, 0 runts, 0 giants, 0 throttles
0 CRC, 0 frame, 0 overruns, - aborts
- ignored, - parity errors
Output (total): 0 packets, 0 bytes
0 unicasts, 0 broadcasts, 0 multicasts, - pauses
Output (normal): 0 packets, 0 bytes
0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses
Output: 0 output errors, - underruns, - buffer failures
0 aborts, 0 deferred, 0 collisions, 0 late collisions
- lost carrier, - no carrier
Peak input rate: 0 bytes/sec, at 2013-07-07 16:07:11
Peak output rate: 0 bytes/sec, at 2013-07-07 16:07:11
# Display detailed information about Layer 2 interface Ten-GigabitEthernet 1/0/1.
<Sysname> display interface ten-gigabitethernet 1/0/1
Ten-GigabitEthernet1/0/1
Current state: DOWN
Line protocol state: DOWN
IP packet frame type: Ethernet II, hardware address: 000c-2963-b767
Description: Ten-GigabitEthernet1/0/1 Interface
Bandwidth: 100000 kbps
Loopback is not set
Media type is twisted pair,port hardware type is 1000_BASE_T_AN_SFP
Unknown-speed mode, unknown-duplex mode
Link speed type is autonegotiation, link duplex type is autonegotiation
Flow-control is not enabled
Maximum frame length: 9216
Allow jumbo frame to pass
Broadcast max-ratio: 100%
Multicast max-ratio: 100%
Unicast max-ratio: 100%
PVID: 1
MDI type: Automdix
Port link-type: Access
Tagged VLANs: None
UnTagged VLANs: 1
Port priority: 2
Last link flapping: 6 hours 39 minutes 25 seconds
Last clearing of counters: 14:34:09 Tue 11/01/2011
Current system time: 2017-10-27 15:10:03
Last time when physical state changed to up:-
Last time when physical state changed to down: 2017-10-27 14:56:38
Peak input rate: 0 bytes/sec, at 2013-07-17 22:06:19
Peak output rate: 0 bytes/sec, at 2013-07-17 22:06:19
Last 300 seconds input: 0 packets/sec 0 bytes/sec 0 bits/sec 0.00%
Last 300 seconds output: 0 packets/sec 0 bytes/sec 0 bits/sec 0.00%
Input (total): 0 packets, 0 bytes
0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses
Input (normal): 0 packets, 0 bytes
0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses
Input: 0 input errors, 0 runts, 0 giants, 0 throttles
0 CRC, 0 frame, 0 overruns, 0 aborts
0 ignored, 0 parity errors
Output (total): 0 packets, 0 bytes
0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses
Output (normal): 0 packets, 0 bytes
0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses
Output: 0 output errors, 0 underruns, 0 buffer failures
0 aborts, 0 deferred, 0 collisions, 0 late collisions
0 lost carrier, 0 no carrier
Field |
Description |
Current state |
Physical link state of the interface: · Administratively DOWN—The interface has been shut down by using the shutdown command. · DOWN—The interface is administratively up, but its physical state is down (possibly because no physical link exists or the link has failed). · DOWN ( Link-Aggregation interface down )—The aggregate interface to which the interface belongs has been shut down by using the shutdown command. · mac-address moving down—The interface has been shut down by the MAC address move suppression feature. · Storm-Constrain—The interface has been shut down because the storm control feature detected that unknown unicast traffic, multicast traffic, or broadcast traffic exceeded the upper threshold. · STP DOWN—The interface has been shut down by the BPDU guard feature. · UP—The interface is both administratively and physically up. |
Line protocol state |
Data link layer state of the interface. The state is determined through automatic parameter negotiation at the data link layer. · UP—The data link layer protocol is up. · UP (spoofing)—The data link layer protocol is up, but the link is an on-demand link or does not exist. This attribute is typical of null interfaces and loopback interfaces. · DOWN—The data link layer protocol is down. · DOWN (protocols)—The data link layer has been shut down by protocols included in the parentheses. Available protocols include: ¡ DLDP—Shuts down the data link layer when it detects that the link is unidirectional. ¡ OAM—Shuts down the data link layer when it detects a remote link failure. ¡ LAGG—Shuts down the data link layer when it detects that the aggregate interface does not have Selected ports. ¡ BFD—Shuts down the data link layer when it detects a link failure. |
Bandwidth |
Expected bandwidth of the interface. |
Maximum transmission unit |
MTU of the interface. |
Internet protocol processing |
IP configuration parameter of the interface when the interface is not assigned an IP address: · Disabled—The interface cannot process IP packets. · Enabled—The interface can process IP packets. |
Internet address: ip-address/mask-length (Type) |
IP address of the interface and type of the address in parentheses. Possible IP address types include: · Primary—Manually configured primary IP address. · Sub—Manually configured secondary IP address. If the interface has both primary and secondary IP addresses, the primary IP address is displayed. If the interface has only secondary IP addresses, the lowest secondary IP address is displayed. · DHCP-allocated—DHCP allocated IP address. For more information, see DHCP client configuration in Layer 3—IP Services Configuration Guide. · BOOTP-allocated—BOOTP allocated IP address. For more information, see BOOTP client configuration in Layer 3—IP Services Configuration Guide. · Unnumbered—IP address borrowed from another interface. · MTunnel—IP address of the multicast tunnel interface (MTI), which is the same as the IP address of the MVPN source interface. For more information, see multicast VPN configuration in IP Multicast Configuration Guide. |
IP packet frame type |
IPv4 packet framing format. |
hardware address |
MAC address of the interface. |
IPv6 packet frame type |
IPv6 packet framing format. |
FEC mode |
FEC mode of the interface, which depends on the configuration. When the FEC mode of an interface is set to autonegotiation, the actual FEC mode depends on the model of the transceiver module installed in the fiber port. |
Port priority |
Port priority of the interface. |
Loopback is set internal |
An internal loopback test is running on the interface. This field depends on your configuration . |
Loopback is set external |
An external loopback test is running on the interface. This field depends on your configuration. |
Loopback is not set |
No loopback test is running on the interface. This field depends on your configuration. |
1000Mbps-speed mode |
The interface is operating at 1000 Mbps. This field depends on your configuration and the link parameter negotiation result. |
10Gbps-speed mode |
The interface is operating at 10 Gbps. This field depends on your configuration and the link parameter negotiation result. |
40Gbps-speed mode |
The interface is operating at 40 Gbps. This field depends on your configuration and the link parameter negotiation result. |
100Gbps-speed mode |
The interface is operating at 100 Gbps. This field depends on your configuration and the link parameter negotiation result. |
Unknown-speed mode |
The speed of the interface is unknown because the speed negotiation fails or the interface is physically disconnected. |
full-duplex mode |
The interface is operating in full duplex mode. This field depends on your configuration and the link parameter negotiation result. |
unknown-duplex mode |
The duplex mode of the interface is unknown because the duplex mode negotiation fails or the interface is physically disconnected. |
Link speed type is autonegotiation |
The interface is configured with the speed auto command. |
Link speed type is force link |
The interface is manually configured with a speed (for example, 10 Mbps or 100 Mbps) by using the speed command. |
link duplex type is autonegotiation |
The interface is configured with the duplex auto command. |
link duplex type is force link |
The interface is manually configured with a duplex mode (for example, half or full) by using the duplex command. |
Flow-control is not enabled |
Generic flow control is disabled on the interface. This field depends on your configuration and the link parameter negotiation result. |
Maximum frame length |
Maximum length of Ethernet frames allowed to pass through the interface. |
Allow jumbo frame to pass |
The interface allows jumbo frames to pass through. |
Broadcast max- |
Broadcast storm suppression threshold in ratio, pps, or kbps. The unit of the threshold depends on your configuration. |
Multicast max- |
Multicast storm suppression threshold in ratio, pps, or kbps. The unit of the threshold depends on your configuration. |
Unicast max- |
Unknown unicast storm suppression threshold in ratio, pps, or kbps. The unit of the threshold depends on your configuration. |
PVID |
Port VLAN ID (PVID) of the interface. |
MDI type |
MDIX mode of the interface: · automdix. · mdi. · mdix. |
Port link-type |
Link type of the interface: · access. · trunk. · hybrid. |
Tagged VLANs |
VLANs for which the interface sends packets without removing VLAN tags. |
Untagged VLANs |
VLANs for which the interface sends packets after removing VLAN tags. |
VLAN Passing |
VLANs whose packets can be forwarded by the port. The VLANs must have been created. |
VLAN permitted |
VLANs whose packets are permitted by the port. |
Trunk port encapsulation |
Encapsulation protocol type for the trunk port. |
Last link flapping |
The amount of time that has elapsed since the most recent physical state change of the interface. This field displays Never if the interface has been physically down since device startup. |
Last clearing of counters |
Time when the reset counters interface command was last used to clear the interface statistics. This field displays Never if the reset counters interface command has never been used on the interface since device startup. |
Current system time |
Current system time in the YYYY/MM/DD HH:MM:SS format. If the time zone is configured, this field is in the YYYY/MM/DD HH:MM:SS UTC±HH:MM:SS format. |
Last time when physical state changed to up |
Last time when physical state of the interface changed to up. A hyphen (-) indicates that the physical state of the interface has not changed to up. |
Last time when physical state changed to down |
Last time when physical state of the interface changed to down. A hyphen (-) indicates that the physical state of the interface has not changed to down. |
Last 300 seconds input: 0 packets/sec 0 bytes/sec 0 bits/sec 0.00% Last 300 seconds output: 0 packets/sec 0 bytes/sec 0 bits/sec 0.00% |
Average inbound or outbound traffic rate (in pps, Bps, and bps) in the last statistics polling interval, and the ratio of the actual rate to the interface bandwidth. To set the statistics polling interval, execute the flow-interval command. A hyphen (-) indicates that the statistical item is not supported. |
Input(total): 0 packets, 0 bytes 0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses |
The two fields on the first line represent the inbound traffic statistics (in packets and bytes) for the interface. All inbound normal packets, abnormal packets, and normal pause frames were counted. The four fields on the second line represent: · Number of inbound unicast packets. · Number of inbound broadcasts. · Number of inbound multicasts. · Number of inbound pause frames. A hyphen (-) indicates that the statistical item is not supported. |
Input(normal): 0 packets, 0 bytes 0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses |
The two fields on the first line represent the inbound normal traffic and pause frame statistics (in packets and bytes) for the interface. The four fields on the second line represent: · Number of inbound normal unicast packets. · Number of inbound normal broadcasts. · Number of inbound normal multicasts. · Number of inbound normal pause frames. A hyphen (-) indicates that the statistical item is not supported. |
input errors |
Statistics of incoming error packets. |
runts |
Number of inbound frames meeting the following conditions: · Shorter than 64 bytes. · In correct format. · Containing valid CRCs. |
giants |
Number of inbound giants. Giants refer to frames larger than the maximum frame length supported on the interface. For an Ethernet interface that does not permit jumbo frames, the maximum frame length is as follows: · 1518 bytes (without VLAN tags). · 1522 bytes (with VLAN tags). For an Ethernet interface that permits jumbo frames, the maximum Ethernet frame length is set when you configure jumbo frame support on the interface. |
throttles |
Number of inbound frames that had a non-integer number of bytes. |
CRC |
Total number of inbound frames that had a normal length, but contained CRC errors. |
frame |
Total number of inbound frames that contained CRC errors and a non-integer number of bytes. |
overruns |
Number of packets dropped because the input rate of the port exceeded the queuing capability. |
aborts |
Total number of illegal inbound packets: · Fragment frames—CRC error frames shorter than 64 bytes. The length (in bytes) can be an integral or non-integral value. · Jabber frames—CRC error frames greater than the maximum frame length supported on the Ethernet interface (with an integral or non-integral length). ¡ For an Ethernet interface that does not permit jumbo frames, the maximum frame length is 1518 bytes (without VLAN tags) or 1522 bytes (with VLAN tags). ¡ For an Ethernet interface that permits jumbo frames, the maximum Ethernet frame length is set when you configure jumbo frame support on the interface. · Symbol error frames—Frames that contained a minimum of one undefined symbol. · Unknown operation code frames—Non-pause MAC control frames. · Length error frames—Frames whose 802.3 length fields did not match the actual frame length (46 to 1500 bytes). |
ignored |
Number of inbound frames dropped because the receiving buffer of the port ran low. |
parity errors |
Total number of frames with parity errors. |
Output(total): 0 packets, 0 bytes 0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses |
The two fields on the first line represent the outbound traffic statistics (in packets and bytes) for the interface. All outbound normal packets, abnormal packets, and normal pause frames were counted. The four fields on the second line represent: · Number of outbound unicast packets. · Number of outbound broadcasts. · Number of outbound multicasts. · Number of outbound pause frames. A hyphen (-) indicates that the statistical item is not supported. |
Output(normal): 0 packets, 0 bytes 0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses |
The two fields on the first line represent the outbound normal traffic and pause frame statistics (in packets and bytes) for the interface. The four fields on the second line represent: · Number of outbound normal unicast packets. · Number of outbound normal broadcasts. · Number of outbound normal multicasts. · Number of outbound normal pause frames. A hyphen (-) indicates that the statistical item is not supported. |
output errors |
Number of outbound packets with errors. |
underruns |
Number of packets dropped because the output rate of the interface exceeded the output queuing capability. This is a low-probability hardware anomaly. |
buffer failures |
Number of packets dropped because the transmitting buffer of the interface ran low. |
aborts |
Number of packets that failed to be transmitted, for example, because of Ethernet collisions. |
deferred |
Number of frames that the interface deferred to transmit because of detected collisions. |
collisions |
Number of frames that the interface stopped transmitting because Ethernet collisions were detected during transmission. |
late collisions |
Number of frames that the interface deferred to transmit after transmitting their first 512 bits because of detected collisions. |
lost carrier |
Number of carrier losses during transmission. This counter increases by one when a carrier is lost, and applies to serial WAN interfaces. |
no carrier |
Number of times that the port failed to detect the carrier when attempting to send frames. This counter increases by one when a port failed to detect the carrier, and applies to serial WAN interfaces. |
Peak input rate |
Peak rate of inbound traffic in Bps, and the time when the peak inbound traffic rate occurred. |
Peak output rate |
Peak rate of outbound traffic in Bps, and the time when the peak outbound traffic rate occurred. |
# Display brief information about all interfaces.
<Sysname> display interface brief
Brief information on interfaces in route mode:
Link: ADM - administratively down; Stby - standby
Protocol: (s) – spoofing
Interface Link Protocol Primary IP Description
XGE1/0/1 DOWN DOWN --
Loop0 UP UP(s) 2.2.2.9
NULL0 UP UP(s) --
Vlan1 UP DOWN --
Vlan999 UP UP 192.168.1.42
Brief information on interfaces in bridge mode:
Link: ADM - administratively down; Stby - standby
Speed: (a) - auto
Duplex: (a)/A - auto; H - half; F - full
Type: A - access; T - trunk; H - hybrid
Interface Link Speed Duplex Type PVID Description
XGE1/0/2 DOWN auto A A 1
XGE1/0/3 UP 1G(a) F(a) A 1 aaaaaaaaaaaaaaaaaaaaaaaaaaa
# Display brief information about Ten-GigabitEthernet 1/0/3, including the complete description of the interface.
<Sysname> display interface ten-gigabitethernet 1/0/3 brief description
Brief information on interfaces in bridge mode:
Link: ADM - administratively down; Stby - standby
Speed: (a) - auto
Duplex: (a)/A - auto; H - half; F - full
Type: A - access; T - trunk; H - hybrid
Interface Link Speed Duplex Type PVID Description
XGE1/0/3 UP 1G(a) F(a) A 1 aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
# Display information about interfaces in DOWN state and the causes.
<Sysname> display interface brief down
Brief information on interfaces in route mode:
Link: ADM - administratively down; Stby - standby
Interface Link Cause
XGE1/0/1 DOWN Not connected
Brief information on interfaces in bridge mode:
Link: ADM - administratively down; Stby - standby
Interface Link Cause
XGE1/0/2 DOWN Not connected
Field |
Description |
Brief information on interfaces in route mode: |
Brief information about Layer 3 interfaces. |
Interface |
Interface name. |
Link |
Physical link state of the interface: · UP—The interface is physically up. · DOWN—The interface is physically down. · ADM—The interface has been shut down by using the shutdown command. To restore the physical state of the interface, use the undo shutdown command. |
Protocol |
Data link layer protocol state of the interface: · UP—The data link layer protocol of the interface is up. · DOWN—The data link layer protocol of the interface is down. · UP(s)—The data link layer protocol of the interface is up, but the link is an on-demand link or does not exist. The (s) attribute represents the spoofing flag. This value is typical of null interfaces and loopback interfaces. |
Primary IP |
Primary IP address of the interface. This field displays two hyphens (--) if the interface does not have an IP address. |
Description |
Description of the interface. |
Brief information of interfaces in bridge mode: |
Brief information about Layer 2 interfaces. |
Type: A - access; T - trunk; H – hybrid |
Link type options for interfaces. |
Speed |
Speed of the interface, in bps. This field displays the (a) flag next to the speed if the speed is automatically negotiated. This field displays auto if the interface is configured to autonegotiate its speed but the autonegotiation has not started. |
Duplex |
Duplex mode of the interface: · A—Autonegotiation. The interface is configured to autonegotiate its duplex mode but the autonegotiation has not started. · F—Full duplex. · F(a)—Autonegotiated full duplex. · H—Half duplex. · H(a)—Autonegotiated half duplex. |
Type |
Link type of the interface: · A—Access. · H—Hybrid. · T—Trunk. |
PVID |
Port VLAN ID. |
Cause |
Cause for the physical link state of an interface to be DOWN: · Administratively—The interface has been manually shut down by using the shutdown command. To restore the physical state of the interface, use the undo shutdown command. · DOWN ( Link-Aggregation interface down )—The interface is a member port of an aggregate interface, and the aggregate interface is down. · DOWN (Loopback detection down)—The loopback detection module has detected loops. · DOWN ( Monitor-Link uplink down )—The monitor link module has detected that the uplink is down. · Not connected—No physical connection exists (possibly because the network cable is disconnected or faulty). · Storm-Constrain—The storm control feature has detected that unknown unicast traffic, multicast traffic, or broadcast traffic exceeded the upper threshold. · STP DOWN—The interface has been shut down by the BPDU guard feature. |
reset counters interface
display interface link-info
Use display interface link-info to display the status and packet statistics of interfaces.
Syntax
display interface link-info [ main ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
main: Specifies all interfaces except subinterfaces. If you do not specify this keyword, this command displays status and packet statistics of all interfaces.
Examples
# Display status and statistics of all interfaces.
<Sysname> display interface link-info
Link: ADM - administratively down; Stby - standby
Protocol: (s) - spoofing
Interface Link Protocol InUsage OutUsage InErrs OutErrs
XGE1/0/1 UP UP 10.09% 0% 0 0
NULL0 UP UP(s) 0% 0% 0 0
Overflow: More than 7 digits.
--: Not supported.
Table 6 Command output
Field |
Description |
Link: ADM - administratively down; Stby - standby |
Physical link state of the interface: · ADM—The interface has been shut down by using the shutdown command. To restore the physical state of the interface, use the undo shutdown command. · Stby—The interface is a backup interface in standby state. |
Protocol: (s) – spoofing |
The data link layer protocol of the interface is up, but the link is an on-demand link or does not exist. The (s) attribute represents the spoofing flag. This value is typical of null interfaces, loopback interfaces, and InLoopback interfaces. |
Interface |
Abbreviated interface name. |
Link |
Physical link state of the interface: · UP—The interface is physically up. · DOWN—The interface is physically down. · ADM—The interface has been shut down by using the shutdown command. To restore the physical state of the interface, use the undo shutdown command. |
Protocol |
Data link layer protocol state of the interface: · UP—The data link layer protocol of the interface is up. · DOWN—The data link layer protocol of the interface is down. · UP(s)—The data link layer protocol of the interface is up, but the link is an on-demand link or does not exist. The (s) attribute represents the spoofing flag. This value is typical of null interfaces, loopback interfaces, and InLoopback interfaces. |
InUsage |
Inbound bandwidth usage within the most recent statistics polling interval. It is calculated by this formula: Average inbound speed of the interface within the most recent statistics polling interval/interface bandwidth. When the usage is smaller than 0.01%, 0.01% is displayed. To set the statistics polling interval, use the flow-interval command. |
OutUsage |
Outbound bandwidth usage within the most recent statistics polling interval. It is calculated by this formula: Average outbound speed of the interface within the most recent statistics polling interval/interface bandwidth. When the usage is smaller than 0.01%, 0.01% is displayed. To set the statistics polling interval, use the flow-interval command. |
InErrs |
Number of error packets received. |
OutErrs |
Number of error packets sent. |
Overflow: More than 7 digits. |
The data length of a statistical item value is greater than 7 decimal digits. |
--: Not supported. |
A hyphen (-) indicates that the corresponding statistical item is not supported. |
Related commands
flow-interval
display interface main
Use display interface main to display operating status and information of all interfaces except subinterfaces.
Syntax
display interface [ interface-type ] [ brief [ description | down ] ] main
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
interface-type: Specifies an interface type. If you do not specify this argument, the command displays information about interfaces of all types.
brief: Displays brief interface information. If you do not specify this keyword, the command displays detailed interface information.
description: Displays complete interface descriptions. If you do not specify this keyword, the command displays only the first 27 characters of each interface description.
down: Displays information about interfaces in down state and the causes. If you do not specify this keyword, the command displays information about interfaces in all states.
Examples
# Display operating status and information of all interfaces except subinterfaces.
<Sysname> display interface main
Ten-GigabitEthernet1/0/1
Current state: Administratively DOWN
Line protocol state: DOWN
IP packet frame type: Ethernet II, hardware address: 4005-6538-0100
Description: Ten-GigabitEthernet1/0/1 Interface
Bandwidth: 1000000 kbps
Loopback is not set
Unknown-speed mode, unknown-duplex mode
Link speed type is autonegotiation, link duplex type is autonegotiation
Flow-control is not enabled
Maximum frame length: 9216
Allow jumbo frames to pass
Broadcast max-ratio: 100%
Multicast max-ratio: 100%
Unicast max-ratio: 100%
PVID: 1
MDI type: Automdix
Port link-type: Access
Tagged VLANs: None
Untagged VLANs: 1
Port priority: 2
Last link flapping: Never
Last clearing of counters: Never
Current system time:2018-04-11 10:20:24
Last time when physical state changed to up:-
Last time when physical state changed to down:2018-04-11 09:11:09
Peak input rate: 0 bytes/sec, at 00-00-00 00:00:00
Peak output rate: 0 bytes/sec, at 00-00-00 00:00:00
Last 300 seconds input: 0 packets/sec 0 bytes/sec 0 bits/sec 0.00%
Last 300 seconds output: 0 packets/sec 0 bytes/sec 0 bits/sec 0.00%
Input (total): 0 packets, 0 bytes
0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses
Input (normal): 0 packets, 0 bytes
0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses
Input: 0 input errors, 0 runts, 0 giants, 0 throttles
0 CRC, 0 frame, 0 overruns, 0 aborts
0 ignored, 0 parity errors
Output (total): 0 packets, 0 bytes
0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses
Output (normal): 0 packets, 0 bytes
0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses
Output: 0 output errors, 0 underruns, 0 buffer failures
0 aborts, 0 deferred, 0 collisions, 0 late collisions
0 lost carrier, 0 no carrier
Ten-GigabitEthernet1/0/2
Current state: Administratively DOWN
Line protocol state: DOWN
Description: Ten-GigabitEthernet1/0/2 Interface
Bandwidth: 1000000 kbps
Flow-control is not enabled
Maximum transmission unit: 1500
Allow jumbo frames to pass
Broadcast max-ratio: 100%
Multicast max-ratio: 100%
Unicast max-ratio: 100%
Internet protocol processing: Disabled
IP packet frame type: Ethernet II, hardware address: 4005-6538-0107
IPv6 packet frame type: Ethernet II, hardware address: 4005-6538-0107
Output queue - Urgent queuing: Size/Length/Discards 0/100/0
Output queue - Protocol queuing: Size/Length/Discards 0/500/0
Output queue - FIFO queuing: Size/Length/Discards 0/75/0
Last link flapping: Never
Last clearing of counters: Never
Current system time:2018-04-11 10:20:24
Last time when physical state changed to up:-
Last time when physical state changed to down:2018-04-11 09:33:52
Peak input rate: 0 bytes/sec, at 00-00-00 00:00:00
Peak output rate: 0 bytes/sec, at 00-00-00 00:00:00
Last 300 seconds input: 0 packets/sec 0 bytes/sec 0 bits/sec 0.00%
Last 300 seconds output: 0 packets/sec 0 bytes/sec 0 bits/sec 0.00%
Input (total): 0 packets, 0 bytes
0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses
Input (normal): 0 packets, 0 bytes
0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses
Input: 0 input errors, 0 runts, 0 giants, 0 throttles
0 CRC, 0 frame, 0 overruns, 0 aborts
0 ignored, 0 parity errors
Output (total): 0 packets, 0 bytes
0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses
Output (normal): 0 packets, 0 bytes
0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses
Output: 0 output errors, 0 underruns, 0 buffer failures
0 aborts, 0 deferred, 0 collisions, 0 late collisions
0 lost carrier, 0 no carrier
# Display brief information of all interfaces except subinterfaces.
<Sysname> display interface brief main
Brief information on interfaces in route mode:
Link: ADM - administratively down; Stby - standby
Protocol: (s) – spoofing
Interface Link Protocol Primary IP Description
XGE1/0/1 DOWN DOWN --
Loop0 UP UP(s) 2.2.2.9
NULL0 UP UP(s) --
Vlan1 UP DOWN --
Vlan999 UP UP 192.168.1.42
Brief information on interfaces in bridge mode:
Link: ADM - administratively down; Stby - standby
Speed: (a) - auto
Duplex: (a)/A - auto; H - half; F - full
Type: A - access; T - trunk; H - hybrid
Interface Link Speed Duplex Type PVID Description
XGE1/0/2 DOWN auto A A 1
# Display brief information about all interfaces, including the complete interface descriptions.
<Sysname> display interface brief description main
Brief information on interfaces in bridge mode:
Link: ADM - administratively down; Stby - standby
Speed: (a) - auto
Duplex: (a)/A - auto; H - half; F - full
Type: A - access; T - trunk; H - hybrid
Interface Link Speed Duplex Type PVID Description
XGE1/0/3 UP auto F(a) A 1 aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
# Display information about interfaces in DOWN state and the causes.
<Sysname> display interface brief down main
Brief information on interfaces in route mode:
Link: ADM - administratively down; Stby - standby
Interface Link Cause
XGE1/0/1 DOWN Not connected
Vlan2 DOWN Not connected
Brief information on interfaces in bridge mode:
Link: ADM - administratively down; Stby - standby
Interface Link Cause
XGE1/0/2 DOWN Not connected
For description on the display interface main command output, see Table 4 and Table 5.
display interface split-capable
Use display interface split-capable to display interfaces capable of being split.
Syntax
display interface split-capable [ slot slot-number ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
slot slot-number: Specifies a card by its slot number, which is fixed at 1.
Examples
# Display interfaces capable of being split.
<Sysname> display interface split-capable
slot 1:
100-GE interfaces capable of being split into multiple 10-GE or 25-GE interfaces
:
HundredGigE1/0/25 HundredGigE1/0/26 HundredGigE1/0/27
HundredGigE1/0/28 HundredGigE1/0/29 HundredGigE1/0/30
40-GE interfaces capable of being split into four 10-GE interfaces:
display packet-drop
Use display packet-drop to display information about packets dropped on an interface.
Syntax
display packet-drop { interface [ interface-type [ interface-number ] ] | summary }
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
interface-type: Specifies an interface type. If you do not specify an interface type, this command displays information about dropped packets on all interfaces on the device.
interface-number: Specifies an interface number. If you do not specify an interface number, this command displays information about dropped packets on all interfaces of the specified type.
summary: Displays the summary of dropped packets on all interfaces.
Examples
# Display information about dropped packets on Ten-GigabitEthernet 1/0/1.
<Sysname> display packet-drop interface ten-gigabitethernet 1/0/1
Ten-GigabitEthernet1/0/1:
Packets dropped due to full GBP or insufficient bandwidth: 301
Packets dropped due to Fast Filter Processor (FFP): 261
Packets dropped due to STP non-forwarding state: 321
Packets dropped due to rate-limit: 143
Packets dropped due to broadcast-suppression: 301
Packets dropped due to unicast-suppression: 215
Packets dropped due to multicast-suppression: 241
Packets dropped due to Tx packet aging: 246
# Display the summary of dropped packets on all interfaces.
<Sysname> display packet-drop summary
All interfaces:
Packets dropped due to full GBP or insufficient bandwidth: 301
Packets dropped due to Fast Filter Processor (FFP): 261
Packets dropped due to STP non-forwarding state: 321
Packets dropped due to rate-limit: 143
Packets dropped due to broadcast-suppression: 301
Packets dropped due to unicast-suppression: 215
Packets dropped due to multicast-suppression: 241
Packets dropped due to Tx packet aging: 246
Table 7 Command output
Field |
Description |
Packets dropped due to full GBP or insufficient bandwidth |
Packets that are dropped because the buffer is used up or the bandwidth is insufficient. |
Packets dropped due to Fast Filter Processor (FFP) |
Packets that are filtered out. |
Packets dropped due to STP non-forwarding state |
Packets that are dropped because STP is in the non-forwarding state. |
Packets dropped due to rate-limit |
Packets that are dropped due to the rate limit set on the device. |
Packets dropped due to broadcast-suppression |
Packets that are dropped due to broadcast suppression. |
Packets dropped due to unicast-suppression |
Packets that are dropped due to unknown unicast suppression. |
Packets dropped due to multicast-suppression |
Packets that are dropped due to multicast suppression. |
Packets dropped due to Tx packet aging |
Outbound packets that are timed out. |
display priority-flow-control
Use display priority-flow-control to display priority-based flow control (PFC) information on an interface.
Syntax
display priority-flow-control interface [ interface-type [ interface-number ] ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
interface-type: Specifies an interface type.
interface-number: Specifies an interface number.
Usage guidelines
If you do not specify an interface type, this command displays PFC information for all Ethernet interfaces.
If you specify an interface type but do not specify an interface number, this command displays PFC information for all interfaces of the specified type.
If you specify an interface type and an interface number, this command displays PFC information for the specified interface.
Examples
# Display the PFC information for all Ethernet interfaces.
Conf -- Configured mode Ne -- Negotiated mode P -- Priority
Interface Conf Ne Dot1pList P Recv Sent
XGE1/0/1 Off Off
Table 8 Command output
Field |
Description |
Conf -- Configured mode |
Locally configured PFC status. |
Ne -- Negotiated mode |
Negotiated PFC status. |
P -- Priority |
802.1p priority value for which PFC is enabled. |
Interface |
Abbreviated name of the interface. |
Conf |
Locally configured PFC status: · Auto—The interface is configured to autonegotiate the PFC status with the remote end. · Off—PFC is disabled for the interface. · On—PFC is enabled for the interface. |
Ne |
Negotiated PFC status: · Off—PFC is disabled. · On—PFC is enabled. |
Dot1pList |
802.1p priorities that are enabled with PFC. 802.1p priority values 0 through 7 are available. |
P |
An 802.1p priority is displayed only when the 802.1p priority is enabled with PFC and the interface has received or sent packets with the 802.1p priority. |
Recv |
Number of received PFC pause frames. |
Sent |
Number of sent PFC pause frames. |
Related commands
priority-flow-control
priority-flow-control no-drop dot1p
duplex
Use duplex to set the duplex mode for an Ethernet interface.
Use undo duplex to restore the default.
Syntax
duplex { auto | full | half }
undo duplex
Default
Ethernet interfaces autonegotiate the duplex mode.
Views
Ethernet interface view
Predefined user roles
network-admin
Parameters
auto: Configures the interface to autonegotiate the duplex mode with the peer.
full: Configures the interface to operate in full duplex mode. In this mode, the interface can receive and transmit packets simultaneously.
half: Configures the interface to operate in half duplex mode. In this mode, the interface can only receive or transmit packets at a given time. This keyword is supported only on management Ethernet interfaces.
Examples
# Configure Ten-GigabitEthernet 1/0/1 to operate in full duplex mode.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] duplex full
flow-control
Use flow-control to enable TxRx-mode generic flow control on an Ethernet interface.
Use undo flow-control to disable TxRx-mode generic flow control on the Ethernet interface.
Syntax
flow-control
undo flow-control
Default
TxRx-mode generic flow control is disabled on an Ethernet interface.
Views
Ethernet interface view
Predefined user roles
network-admin
Usage guidelines
With TxRx-mode generic flow control configured, an interface can both send and receive flow control frames:
· When congested, the interface sends a flow control frame to its peer.
· Upon receiving a flow control frame from the peer, the interface suspends sending packets.
To implement flow control on a link, enable generic flow control at both ends of the link.
This command and the priority-flow-control no-drop dot1p command are mutually exclusive.
Examples
# Enable TxRx-mode generic flow control on Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] flow-control
flow-control receive enable
Use flow-control receive enable to enable Rx-mode generic flow control on an Ethernet port.
Use undo flow-control to disable Rx-mode generic flow control on an Ethernet port.
Syntax
flow-control receive enable
undo flow-control
Default
Rx-mode generic flow control is disabled on Ethernet interfaces.
Views
Ethernet interface view
Predefined user roles
network-admin
Usage guidelines
With Rx-mode flow control enabled, an interface can receive but cannot send flow control frames.
· When the interface receives a flow control frame from its peer, it suspends sending packets to the peer.
· When traffic congestion occurs on the interface, it cannot send flow control frames to the peer.
To handle unidirectional traffic congestion on a link, configure the flow-control receive enable command at one end, and the flow-control command at the other. To enable both ends of the link to handle traffic congestion, configure the flow-control command at both ends.
This command is mutually exclusive with the priority-flow-control or priority-flow-control no-drop dot1p command.
Examples
# Enable Rx-mode generic flow control on Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-ten-gigabitethernet 1/0/1] flow-control receive enable
flow-control
flow-interval
Use flow-interval to set the statistics polling interval.
Use undo flow-interval to restore the default.
Syntax
flow-interval interval
undo flow-interval
Default
The statistics polling interval is 300 seconds.
Views
System view
Ethernet interface view
Predefined user roles
network-admin
Parameters
interval: Sets the statistics polling interval in seconds. In system view, the interval is in the range of 5 to 300 and must be a multiple of 5. In Ethernet interface view, the interval is in the range of 1 to 300 and must be a multiple of 1.
Usage guidelines
The statistics polling interval configured in system view takes effect on all Ethernet interfaces.
The statistics polling interval configured in Ethernet interface view takes effect only on the current interface.
The statistics polling interval configured in Ethernet interface view takes precedence over the statistics polling interval configured in system view. The interval configured in system view takes effect on an Ethernet interface only when no interval is configured or the default interval is configured for the Ethernet interface.
As a best practice, use the default value for the flow-interval command in system view. A short static polling interval in system view might decrease the system performance and result in inaccurate statistics.
You can use the display interface command to view the statistics only after two consecutive statistics polling intervals. The statistics are displayed by the Last interval second input and Last interval second input fields in the display interface command output.
Examples
# Set the statistics polling interval to 100 seconds on Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] flow-interval 100
Related commands
display interface
ifmonitor crc-error
Use ifmonitor crc-error to configure global CRC error packet alarm parameters.
Use undo ifmonitor crc-error to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
ifmonitor crc-error slot slot-number high-threshold high-value low-threshold low-value interval interval [ shutdown ]
undo ifmonitor crc-error slot slot-number
Default
The upper threshold is 1000, the lower threshold is 100, and the statistics collection and comparison interval is 10 seconds for CRC error packet alarms.
Views
System view
Predefined user roles
network-admin
Parameters
high-threshold high-value: Specifies the upper threshold for CRC error packet alarms, in the range of 1 to 4294967295 packets.
low-threshold low-value: Specifies the lower threshold for CRC error packet alarms, in the range of 1 to 4294967295 packets.
interval interval: Specifies the statistics collection and comparison interval for CRC error packets, in the range of 1 to 65535 seconds.
shutdown: Shuts down an interface when the number of incoming CRC error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of incoming CRC error packets exceeds the upper threshold on the interface.
slot slot-number: Specifies a card by its slot number.
Usage guidelines
With the CRC error packet alarm function enabled, when the number of incoming CRC error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of incoming CRC error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can configure the CRC error packet alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 5000, lower threshold to 400, and statistics collection and comparison interval to 6 seconds for CRC error packet alarms.
<Sysname> system-view
[Sysname] ifmonitor crc-error slot 1 high-threshold 5000 low-threshold 400 interval 6
Related commands
snmp-agent trap enable ifmonitor
ifmonitor giant
Use ifmonitor giant to configure global giant packet alarm parameters.
Use undo ifmonitor giant to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
ifmonitor giant slot slot-number high-threshold high-value low-threshold low-value interval interval [ shutdown ]
undo ifmonitor giant slot slot-number
Default
The upper threshold is 1000, the lower threshold is 100, and the statistics collection and comparison interval is 10 seconds for giant packet alarms.
Views
System view
Predefined user roles
network-admin
Parameters
high-threshold high-value: Specifies the upper threshold for giant packet alarms, in the range of 1 to 4294967295 packets.
low-threshold low-value: Specifies the lower threshold for giant packet alarms, in the range of 1 to 4294967295 packets.
interval interval: Specifies the statistics collection and comparison interval for giant packets, in the range of 1 to 65535 seconds.
shutdown: Shuts down an interface when the number of incoming giant packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface.
slot slot-number: Specifies a card by its slot number.
Usage guidelines
With the giant packet alarm function enabled, when the number of incoming giant packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of incoming giant packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can configure the giant packet alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 5, lower threshold to 4, and statistics collection and comparison interval to 6 seconds for giant packet alarms.
<Sysname> system-view
[Sysname] ifmonitor giant slot 1 high-threshold 5 low-threshold 4 interval 6
Related commands
port ifmonitor giant
snmp-agent trap enable ifmonitor
ifmonitor input-error
Use ifmonitor input-error to configure global input error packet alarm parameters.
Use undo ifmonitor input-error to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
ifmonitor input-error slot slot-number high-threshold high-value low-threshold low-value interval interval [ shutdown ]
undo ifmonitor input-error slot slot-number
Default
The upper threshold is 1000, the lower threshold is 100, and the statistics collection and comparison interval is 10 seconds for input error packet alarms.
Views
System view
Predefined user roles
network-admin
Parameters
high-threshold high-value: Specifies the upper threshold for input error packet alarms, in the range of 1 to 4294967295 packets.
low-threshold low-value: Specifies the lower threshold for input error packet alarms, in the range of 1 to 4294967295 packets.
interval interval: Specifies the statistics collection and comparison interval for input error packets, in the range of 1 to 65535 seconds.
shutdown: Shuts down an interface when the number of input error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of input error packets exceeds the upper threshold on the interface.
slot slot-number: Specifies a card by its slot number.
Usage guidelines
With the input error packet alarm function enabled, when the number of input error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of input error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can configure the input error packet alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 5000, lower threshold to 400, and statistics collection and comparison interval to 6 seconds for input error packet alarms.
<Sysname> system-view
[Sysname] ifmonitor input-error slot 1 high-threshold 5000 low-threshold 400 interval 6
Related commands
snmp-agent trap enable ifmonitor
ifmonitor input-usage
Use ifmonitor input-usage to configure global input bandwidth usage alarm parameters.
Use undo ifmonitor input-usage to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
ifmonitor input-usage slot slot-number high-threshold high-value low-threshold low-value
undo ifmonitor input-usage slot slot-number
Default
The upper threshold is 90, and the lower threshold is 80.
Views
System view
Predefined user roles
network-admin
Parameters
high-threshold high-value: Specifies the upper threshold for input bandwidth usage alarms, in the range of 1 to 100.
low-threshold low-value: Specifies the lower threshold for input bandwidth usage alarms, in the range of 1 to 100.
slot slot-number: Specifies a card by its slot number.
Usage guidelines
With the input bandwidth usage alarm function enabled, when the input bandwidth usage on an interface in normal state within the most recent statistics polling interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the input bandwidth usage on an interface in the alarm state within the most recent statistics polling interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can use the flow-interval command to set the statistics polling interval.
You can configure the input bandwidth usage alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the input bandwidth usage alarm function.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 95 and lower threshold to 80 for input bandwidth usage alarms.
<Sysname> system-view
[Sysname] ifmonitor input-usage slot 1 high-threshold 95 low-threshold 80
Related commands
flow-interval
snmp-agent trap enable ifmonitor
ifmonitor output-error
Use ifmonitor output-error to configure global output error packet alarm parameters.
Use undo ifmonitor output-error to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
ifmonitor output-error slot slot-number high-threshold high-value low-threshold low-value interval interval [ shutdown ]
undo ifmonitor output-error slot slot-number
Default
The upper threshold is 1000, the lower threshold is 100, and the statistics collection and comparison interval is 10 seconds for output error packet alarms.
Views
System view
Predefined user roles
network-admin
Parameters
high-threshold high-value: Specifies the upper threshold for output error packet alarms, in the range of 1 to 4294967295 packets.
low-threshold low-value: Specifies the lower threshold for output error packet alarms, in the range of 1 to 4294967295 packets.
interval interval: Specifies the statistics collection and comparison interval for output error packets, in the range of 1 to 65535 seconds.
shutdown: Shuts down an interface when the number of output error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of output error packets exceeds the upper threshold on the interface.
slot slot-number: Specifies a card by its slot number.
Usage guidelines
With the output error packet alarm function enabled, when the number of output error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of output error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can configure the output error packet alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 5000, lower threshold to 400, and statistics collection and comparison interval to 6 seconds for output error packet alarms.
<Sysname> system-view
[Sysname] ifmonitor output-error slot 1 high-threshold 5000 low-threshold 400 interval 6
Related commands
snmp-agent trap enable ifmonitor
ifmonitor output-usage
Use ifmonitor output-usage to configure global output bandwidth usage alarm parameters.
Use undo ifmonitor output-usage to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
ifmonitor output-usage slot slot-number high-threshold high-value low-threshold low-value
undo ifmonitor output-usage slot slot-number
Default
The upper threshold is 90, and the lower threshold is 80.
Views
System view
Predefined user roles
network-admin
Parameters
high-threshold high-value: Specifies the upper threshold for output bandwidth usage alarms, in the range of 1 to 100.
low-threshold low-value: Specifies the lower threshold for output bandwidth usage alarms, in the range of 1 to 100.
slot slot-number: Specifies a card by its slot number.
Usage guidelines
With the output bandwidth usage alarm function enabled, when the output bandwidth usage on an interface in normal state within the most recent statistics polling interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the output bandwidth usage on an interface in the alarm state within the most recent statistics polling interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can use the flow-interval command to set the statistics polling interval.
You can configure the output bandwidth usage alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the output bandwidth usage alarm function.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 80 and lower threshold to 60 for output bandwidth usage alarms.
<Sysname> system-view
[Sysname] ifmonitor output-usage slot 1 high-threshold 80 low-threshold 60
Related commands
flow-interval
snmp-agent trap enable ifmonitor
ifmonitor runt
Use ifmonitor runt to configure global runt packet alarm parameters.
Use undo ifmonitor runt to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
ifmonitor runt slot slot-number high-threshold high-value low-threshold low-value interval interval [ shutdown ]
undo ifmonitor runt slot slot-number
Default
The upper threshold is 1000, the lower threshold is 100, and the statistics collection and comparison interval is 10 seconds for runt packet alarms.
Views
System view
Predefined user roles
network-admin
Parameters
high-threshold high-value: Specifies the upper threshold for runt packet alarms, in the range of 1 to 4294967295 packets.
low-threshold low-value: Specifies the lower threshold for runt packet alarms, in the range of 1 to 4294967295 packets.
interval interval: Specifies the statistics collection and comparison interval for runt packets, in the range of 1 to 65535 seconds.
shutdown: Shuts down an interface when the number of incoming runt packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface.
slot slot-number: Specifies a card by its slot number.
Usage guidelines
With the runt packet alarm function enabled, when the number of incoming runt packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of incoming runt packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can configure the runt packet alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 5, lower threshold to 4, and statistics collection and comparison interval to 6 seconds for runt packet alarms.
<Sysname> system-view
[Sysname] ifmonitor runt slot 1 high-threshold 5 low-threshold 4 interval 6
Related commands
port ifmonitor runt
snmp-agent trap enable ifmonitor
ifmonitor rx-pause
Use ifmonitor rx-pause to configure global received pause frame alarm parameters.
Use undo ifmonitor rx-pause to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
ifmonitor rx-pause slot slot-number high-threshold high-value low-threshold low-value interval interval
undo ifmonitor rx-pause slot slot-number
Default
The upper threshold is 500, the lower threshold is 100, and the statistics collection and comparison interval is 10 seconds for received pause frame alarms.
Views
System view
Predefined user roles
network-admin
Parameters
high-threshold high-value: Specifies the upper threshold for received pause frame alarms, in the range of 1 to 4294967295 packets.
low-threshold low-value: Specifies the lower threshold for received pause frame alarms, in the range of 1 to 4294967295 packets.
interval interval: Specifies the statistics collection and comparison interval for received pause frames, in the range of 1 to 65535 seconds.
slot slot-number: Specifies a card by its slot number.
Usage guidelines
With the received pause frame alarm function enabled, when the number of received pause frames on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of received pause frames on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can configure the received pause frame alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the received pause frame alarm function.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 30, lower threshold to 20, and statistics collection and comparison interval to 4 seconds for received pause frame alarms.
<Sysname> system-view
[Sysname] ifmonitor rx-pause slot 1 high-threshold 30 low-threshold 20 interval 4
Related commands
snmp-agent trap enable ifmonitor
ifmonitor sdh-b1-error
Use ifmonitor sdh-b1-error to configure global SDH-B1 error packet alarm parameters.
Use undo ifmonitor sdh-b1-error to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
ifmonitor sdh-b1-error slot slot-number high-threshold high-value low-threshold low-value interval interval [ shutdown ]
undo ifmonitor sdh-b1-error slot slot-number
Default
The upper threshold is 1000, the lower threshold is 100, and the statistics collection and comparison interval is 10 seconds for SDH-B1 error packet alarms.
Views
System view
Predefined user roles
network-admin
Parameters
high-threshold high-value: Specifies the upper threshold for SDH-B1 error packet alarms, in the range of 1 to 4294967295 packets.
low-threshold low-value: Specifies the lower threshold for SDH-B1 error packet alarms, in the range of 1 to 4294967295 packets.
interval interval: Specifies the statistics collection and comparison interval for SDH-B1 error packets, in the range of 1 to 65535 seconds.
shutdown: Shuts down an interface when the number of incoming SDH-B1 error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of incoming SDH-B1 error packets exceeds the upper threshold on the interface.
slot slot-number: Specifies a card by its slot number.
Usage guidelines
With the SDH-B1 error packet alarm function enabled, when the number of incoming SDH-B1 error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of incoming SDH-B1 error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can configure the SDH-B1 error packet alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the SDH-B1 error packet alarm function.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 65, lower threshold to 25, and statistics collection and comparison interval to 20 seconds for SDH-B1 error packet alarms.
<Sysname> system-view
[Sysname] ifmonitor sdh-b1-error slot 1 high-threshold 65 low-threshold 25 interval 20
Related commands
snmp-agent trap enable ifmonitor
ifmonitor sdh-b2-error
Use ifmonitor sdh-b2-error to configure global SDH-B2 error packet alarm parameters.
Use undo ifmonitor sdh-b2-error to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
ifmonitor sdh-b2-error slot slot-number high-threshold high-value low-threshold low-value interval interval [ shutdown ]
undo ifmonitor sdh-b2-error slot slot-number
Default
The upper threshold is 1000, the lower threshold is 100, and the statistics collection and comparison interval is 10 seconds for SDH-B2 error packet alarms.
Views
System view
Predefined user roles
network-admin
Parameters
high-threshold high-value: Specifies the upper threshold for SDH-B2 error packet alarms, in the range of 1 to 4294967295 packets.
low-threshold low-value: Specifies the lower threshold for SDH-B2 error packet alarms, in the range of 1 to 4294967295 packets.
interval interval: Specifies the statistics collection and comparison interval for SDH-B2 error packets, in the range of 1 to 65535 seconds.
shutdown: Shuts down an interface when the number of incoming SDH-B2 error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of incoming SDH-B2 error packets exceeds the upper threshold on the interface.
slot slot-number: Specifies a card by its slot number.
Usage guidelines
With the SDH-B2 error packet alarm function enabled, when the number of incoming SDH-B2 error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of incoming SDH-B2 error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can configure the SDH-B2 error packet alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the SDH-B2 error packet alarm function.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 6, lower threshold to 5, and statistics collection and comparison interval to 2 seconds for SDH-B2 error packet alarms.
<Sysname> system-view
[Sysname] ifmonitor sdh-b2-error slot 1 high-threshold 6 low-threshold 5 interval 2
Related commands
snmp-agent trap enable ifmonitor
ifmonitor sdh-error
Use ifmonitor sdh-error to configure global SDH error packet alarm parameters.
Use undo ifmonitor sdh-error to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
ifmonitor sdh-error slot slot-number high-threshold high-value low-threshold low-value interval interval [ shutdown ]
undo ifmonitor sdh-error slot slot-number
Default
The upper threshold is 1000, the lower threshold is 100, and the statistics collection and comparison interval is 10 seconds for SDH error packet alarms.
Views
System view
Predefined user roles
network-admin
Parameters
high-threshold high-value: Specifies the upper threshold for SDH error packet alarms, in the range of 1 to 4294967295 packets.
low-threshold low-value: Specifies the lower threshold for SDH error packet alarms, in the range of 1 to 4294967295 packets.
interval interval: Specifies the statistics collection and comparison interval for SDH error packets, in the range of 1 to 65535 seconds.
shutdown: Shuts down an interface when the number of incoming SDH error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of incoming SDH error packets exceeds the upper threshold on the interface.
slot slot-number: Specifies a card by its slot number.
Usage guidelines
With the SDH error packet alarm function enabled, when the number of incoming SDH error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of incoming SDH error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can configure the SDH error packet alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the SDH error packet alarm function.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 35, lower threshold to 20, and statistics collection and comparison interval to 8 seconds for SDH error packet alarms.
<Sysname> system-view
[Sysname] ifmonitor sdh-error slot 1 high-threshold 35 low-threshold 20 interval 8
Related commands
snmp-agent trap enable ifmonitor
ifmonitor tx-pause
Use ifmonitor tx-pause to configure global sent pause frame alarm parameters.
Use undo ifmonitor tx-pause to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
ifmonitor tx-pause slot slot-number high-threshold high-value low-threshold low-value interval interval
undo ifmonitor tx-pause slot slot-number
Default
The upper threshold is 500, the lower threshold is 100, and the statistics collection and comparison interval is 10 seconds for sent pause frame alarms.
Views
System view
Predefined user roles
network-admin
Parameters
high-threshold high-value: Specifies the upper threshold for sent pause frame alarms, in the range of 1 to 4294967295 packets.
low-threshold low-value: Specifies the lower threshold for sent pause frame alarms, in the range of 1 to 4294967295 packets.
interval interval: Specifies the statistics collection and comparison interval for sent pause frames, in the range of 1 to 65535 seconds.
slot slot-number: Specifies a card by its slot number.
Usage guidelines
With the sent pause frame alarm function enabled, when the number of sent pause frames on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of sent pause frames on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can configure the sent pause frame alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the sent pause frame alarm function.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 20, lower threshold to 10, and statistics collection and comparison interval to 5 seconds for sent pause frame alarms.
<Sysname> system-view
[Sysname] ifmonitor tx-pause slot 1 high-threshold 20 low-threshold 10 interval 5
Related commands
snmp-agent trap enable ifmonitor
interface
Use interface to enter interface view, create a subinterface and enter its view, or enter the view of an existing subinterface.
Syntax
interface interface-type { interface-number | interface-number.subnumber }
Views
System view
Predefined user roles
network-admin
Parameters
interface-type: Specifies an interface type.
interface-number: Specifies an interface number.
interface-number.subnumber: Specifies a subinterface number. The interface-number argument is an interface number. The subnumber argument is the number of a subinterface created under the interface. The value range for the subnumber argument is 1 to 4094.
Usage guidelines
After creating a Layer 3 Ethernet subinterface on a device operating in enhanced Layer 2 mode, for the subinterface to forward traffic, you must use the vlan-type dot1q vid vlan-id command to configure VLAN termination on it. Make sure the value for the vlan-id argument is the same as the subinterface number. For more information about system operating mode, see device management in Fundamentals Configuration Guide.
Examples
# Enter the view of Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1]
# Create Ethernet subinterface Ten-GigabitEthernet 1/0/1.1 and enter its view.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1.1
[Sysname-Ten-GigabitEthernet1/0/1.1]
Related commands
vlan-type dot1q vid (Layer 2—LAN Switching Command Reference)
jumboframe enable
Use jumboframe enable to allow jumbo frames within the specified length to pass through.
Use undo jumboframe enable to prevent jumbo frames from passing through.
Use undo jumboframe enable size to restore the default.
Syntax
jumboframe enable [ size ]
undo jumboframe enable [ size ]
Default
The device allows jumbo frames within 12288 bytes to pass through.
Views
Layer 2 Ethernet interface view
Layer 3 Ethernet interface view
Predefined user roles
network-admin
Parameters
size: Sets the maximum length (in bytes) of Ethernet frames that are allowed to pass through. The value range for this argument is 1536 to 12288.
Usage guidelines
If you execute this command multiple times, the most recent configuration takes effect.
Examples
# Allow jumbo frames to pass through Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] jumboframe enable
link-delay
Use link-delay to set the physical state change suppression interval on an Ethernet interface.
Use undo link-delay to restore the default.
Syntax
link-delay { down | up } [ msec ] delay-time
undo link-delay { down | up }
Default
Physical state change suppression is not configured.
Views
Ethernet interface view
Predefined user roles
network-admin
Parameters
down: Suppresses link-down events.
up: Suppresses link-up events.
msec: Enables the physical state change suppression interval to be accurate to milliseconds. If you do not specify this keyword, the suppression interval is accurate to seconds.
delay-time: Sets the physical state change suppression interval on the Ethernet interface. A value of 0 means that physical state changes are immediately reported to the CPU and are not suppressed.
· If you do not specify the msec keyword, the value is in seconds and the value range is 0 to 30.
· If you specify the msec keyword, the value range is 0 to 10000 milliseconds, and the value must be a multiple of 10.
Usage guidelines
You can configure this feature to suppress only link-down events, only link-up events, or both. If an event of the specified type still exists when the suppression interval expires, the system reports the event.
When you configure this feature, follow these guidelines:
· To suppress link-down events, configure the link-delay down command.
· To suppress link-up events, configure the link-delay up command.
On an interface, you can configure different suppression intervals for link-up and link-down events. If you execute the link-delay command multiple times on an interface, the following rules apply:
· You can configure the suppression intervals for link-up and link-down events separately.
· If you configure the suppression interval multiple times for link-up or link-down events, the most recent configuration takes effect.
Do not execute this command on an interface with RRPP, spanning tree protocols, or Smart Link enabled.
Examples
# Set the link-down event suppression interval to 8 seconds on Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] link-delay down 8
# Set the link-up event suppression interval to 800 milliseconds on Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] link-delay up msec 800
linkdown trap enable shutdown
Use linkdown trap enable shutdown to enable the function of generating LinkDown notifications upon interface shutdown.
Use undo linkdown trap enable shutdown to disable the function of generating LinkDown notifications upon interface shutdown.
Syntax
linkdown trap enable shutdown
undo linkdown trap enable shutdown
Default
The function of generating LinkDown notifications upon interface shutdown is enabled.
Views
System view
Predefined user roles
network-admin
Usage guidelines
With the snmp-agent trap enable standard linkdown command executed in system view and the enable snmp trap updown command executed in interface view, the device sends a LinkUp notification when an interface comes up and sends a LinkDown notification when an interface goes down. Because an interface might go down for various reasons, you can use this command to enable or disable the function of generating LinkDown notifications when an interface is shut down and enters the ADM state.
The generated notifications are sent to the SNMP module, and the SNMP module can output the notifications to an NMS.
Examples
# Disable the function of generating LinkDown notifications upon interface shutdown.
<Sysname> system-view
[Sysname] undo linkdown trap enable shutdown
Related commands
enable snmp trap updown (Network Management and Monitoring Command Reference)
snmp-agent trap enable standard (Network Management and Monitoring Command Reference)
loopback
CAUTION: After you enable loopback testing on an Ethernet interface, the interface does not forward data traffic. |
Use loopback to enable loopback testing on an Ethernet interface.
Use undo loopback to disable loopback testing on an Ethernet interface.
Syntax
loopback { external | internal }
undo loopback
Default
Loopback testing is disabled on an Ethernet interface.
Views
Ethernet interface view
Predefined user roles
network-admin
Parameters
external: Enables external loopback testing on the Ethernet interface.
internal: Enables internal loopback testing on the Ethernet interface.
Usage guidelines
After you enable loopback testing on an Ethernet interface, the Ethernet interface switches to full duplex mode. After you disable loopback testing, the Ethernet interface restores to its duplex setting.
The shutdown, port up-mode, and loopback commands are mutually exclusive.
Examples
# Enable internal loopback testing on Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] loopback internal
multicast-suppression
Use multicast-suppression to enable multicast storm suppression and set the multicast storm suppression threshold.
Use undo multicast-suppression to disable multicast storm suppression.
Syntax
multicast-suppression { ratio | pps max-pps | kbps max-kbps }
undo multicast-suppression
Default
Ethernet interfaces do not suppress multicast traffic.
Views
Ethernet interface view
Predefined user roles
network-admin
Parameters
ratio: Sets the multicast suppression threshold as a percentage of the interface bandwidth. The value range for this argument (in percentage) is 0 to 100. A smaller value means that less multicast traffic is allowed to pass through.
pps max-pps: Specifies the maximum number of multicast packets that the interface can forward per second. The value range for the max-pps argument (in pps) is 0 to 1.4881 × the interface bandwidth.
kbps max-kbps: Specifies the maximum number of kilobits of multicast traffic that the Ethernet interface can forward per second. The value range for this argument (in kbps) is 0 to the interface bandwidth.
Usage guidelines
The multicast storm suppression feature limits the size of multicast traffic to a threshold on an interface. When the multicast traffic on the interface exceeds this threshold, the system drops packets until the traffic drops below this threshold.
Both the storm-constrain command and the multicast-suppression command can suppress multicast storms on a port. The multicast-suppression command uses the chip to physically suppress multicast traffic. It has less influence on the device performance than the storm-constrain command, which uses software to suppress multicast traffic.
For the traffic suppression result to be determined, do not configure both the storm-constrain multicast command and the multicast-suppression command on an interface.
When you configure the suppression threshold in kbps, the actual suppression threshold might be different from the configured one as follows:
· If the configured value is smaller than 64, the value of 64 takes effect.
· If the configured value is greater than 64 but not an integer multiple of 64, the integer multiple of 64 that is greater than and closest to the configured value takes effect.
For the suppression threshold that takes effect, see the prompt on the device.
Examples
# Set the multicast storm suppression threshold to 10000 kbps on Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] multicast-suppression kbps 10000
The actual value is 10048 on port Ten-GigabitEthernet1/0/1 currently.
The output shows that the value that takes effect is 10048 kbps (157 times of 64), because the chip only supports step 64.
Related commands
broadcast-suppression
unicast-suppression
port fec mode
Use port fec mode to set the forward error correction (FEC) mode of an interface.
Use undo port fec mode to restore the default.
Syntax
port fec mode { auto | none | rs-fec }
undo port fec mode
Default
The FEC mode of an interface is autonegotiated.
Views
100-GE interface view
Predefined user roles
network-admin
Parameters
auto: Specifies the FEC autonegotiation mode.
none: Performs no FEC.
rs-fec: Specifies the RS-FEC mode.
Usage guidelines
The FEC feature corrects packet errors to improve transmission quality. It attaches correction information to a packet at the sending end, and corrects error codes generated during transmission at the receiving end based on the correction information. You can set the FEC mode as needed.
Make sure you set the same FEC mode for both interfaces of a link.
Examples
# Set the FEC mode of HundredGigE 1/0/1 to autonegotiation.
<Sysname> system-view
[Sysname] interface hundredgige 1/0/1
[Sysname-HundredGigE1/0/1] port fec mode auto
port ifmonitor crc-error
Use port ifmonitor crc-error to configure CRC error packet alarm parameters for an interface.
Use undo port ifmonitor crc-error to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
port ifmonitor crc-error [ ratio ] high-threshold high-value low-threshold low-value interval interval [ shutdown ]
undo port ifmonitor crc-error
Default
An interface uses the global CRC error packet alarm parameters.
Views
Ethernet interface view
Predefined user roles
network-admin
context-admin
Parameters
ratio: Specifies the alarm thresholds in percentage. If you do not specify this keyword, you configure the alarm thresholds in absolute value.
high-threshold high-value: Specifies the upper threshold for CRC error packet alarms. If you specify the ratio keyword, the value range is 1 to 100. If you do not specify the ratio keyword, the value range is 1 to 4294967295 packets.
low-threshold low-value: Specifies the lower threshold for CRC error packet alarms. If you specify the ratio keyword, the value range is 1 to 100. If you do not specify the ratio keyword, the value range is 1 to 4294967295 packets.
interval interval: Specifies the statistics collection and comparison interval for CRC error packets, in the range of 1 to 65535 seconds.
shutdown: Shuts down an interface when the number of incoming CRC error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of incoming CRC error packets exceeds the upper threshold on the interface.
Usage guidelines
With the CRC error packet alarm function enabled, when the number of incoming CRC error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of incoming CRC error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can configure the CRC error packet alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 5000, lower threshold to 400, and statistics collection and comparison interval to 6 seconds for CRC error packet alarms on HundredGigE 1/0/1.
<Sysname> system-view
[Sysname] interface hundredgige 1/0/1
[Sysname-HundredGigE1/0/1] port ifmonitor crc-error high-threshold 5000 low-threshold 400 interval 6
Related commands
snmp-agent trap enable ifmonitor
port ifmonitor giant
Use port ifmonitor giant to configure giant packet alarm parameters for an interface.
Use undo port ifmonitor giant to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
port ifmonitor giant high-threshold high-value low-threshold low-value interval interval [ shutdown ]
undo port ifmonitor giant
Default
An interface uses the global giant packet alarm parameters.
Views
Ethernet interface view
Predefined user roles
network-admin
context-admin
Parameters
high-threshold high-value: Specifies the upper threshold for giant packet alarms, in the range of 1 to 4294967295.
low-threshold low-value: Specifies the lower threshold for giant packet alarms, in the range of 1 to 4294967295.
interval interval: Specifies the statistics collection and comparison interval for giant packets, in the range of 1 to 65535 seconds.
shutdown: Shuts down an interface when the number of incoming giant packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface.
Usage guidelines
With the giant packet alarm function enabled, when the number of incoming giant packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of incoming giant packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can configure the giant packet alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 5, lower threshold to 4, and statistics collection and comparison interval to 6 seconds for giant packet alarms on HundredGigE 1/0/1.
<Sysname> system-view
[Sysname] interface hundredgige 1/0/1
[Sysname-HundredGigE1/0/1] port ifmonitor giant high-threshold 5 low-threshold 4 interval 6
Related commands
ifmonitor giant
snmp-agent trap enable ifmonitor
port ifmonitor input-error
Use port ifmonitor input-error to configure input error packet alarm parameters for an interface.
Use undo port ifmonitor input-error to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
port ifmonitor input-error high-threshold high-value low-threshold low-value interval interval [ shutdown ]
undo port ifmonitor input-error
Default
An interface uses the global input error packet alarm parameters.
Views
Ethernet interface view
Predefined user roles
network-admin
context-admin
Parameters
high-threshold high-value: Specifies the upper threshold for input error packet alarms, in the range of 1 to 4294967295 packets.
low-threshold low-value: Specifies the lower threshold for input error packet alarms, in the range of 1 to 4294967295 packets.
interval interval: Specifies the statistics collection and comparison interval for input error packets, in the range of 1 to 65535 seconds.
shutdown: Shuts down an interface when the number of input error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of input error packets exceeds the upper threshold on the interface.
Usage guidelines
With the input error packet alarm function enabled, when the number of input error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of input error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can configure the input error packet alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 5000, lower threshold to 400, and statistics collection and comparison interval to 6 seconds for input error packet alarms on HundredGigE 1/0/1.
<Sysname> system-view
[Sysname] interface hundredgige 1/0/1
[Sysname-HundredGigE1/0/1] port ifmonitor input-error high-threshold 5000 low-threshold 400 interval 6
Related commands
snmp-agent trap enable ifmonitor
port ifmonitor input-usage
Use port ifmonitor input-usage to configure input bandwidth usage alarm parameters.
Use undo port ifmonitor input-usage to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
port ifmonitor input-usage high-threshold high-value low-threshold low-value
undo port ifmonitor input-usage
Default
An interface uses the global input bandwidth usage alarm parameters.
Views
Ethernet interface view
Predefined user roles
network-admin
context-admin
Parameters
high-threshold high-value: Specifies the upper threshold for input bandwidth usage alarms, in the range of 1 to 100.
low-threshold low-value: Specifies the lower threshold for input bandwidth usage alarms, in the range of 1 to 100.
Usage guidelines
With the input bandwidth usage alarm function enabled, when the input bandwidth usage on an interface in normal state within the most recent statistics polling interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the input bandwidth usage on an interface in the alarm state within the most recent statistics polling interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can use the flow-interval command to set the statistics polling interval.
You can configure the input bandwidth usage alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the input bandwidth usage alarm function.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 80 and lower threshold to 60 for input bandwidth usage alarms on HundredGigE 1/0/1.
<Sysname> system-view
[Sysname] interface hundredgige 1/0/1
[Sysname-HundredGigE1/0/1] port ifmonitor input-usage high-threshold 80 low-threshold 60
Related commands
flow-interval
snmp-agent trap enable ifmonitor
port ifmonitor output-error
Use port ifmonitor output-error to configure output error packet alarm parameters for an interface.
Use undo port ifmonitor output-error to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
port ifmonitor output-error high-threshold high-value low-threshold low-value interval interval [ shutdown ]
undo port ifmonitor output-error
Default
An interface uses the global output error packet alarm parameters.
Views
Ethernet interface view
Predefined user roles
network-admin
context-admin
Parameters
high-threshold high-value: Specifies the upper threshold for output error packet alarms, in the range of 1 to 4294967295 packets.
low-threshold low-value: Specifies the lower threshold for output error packet alarms, in the range of 1 to 4294967295 packets.
interval interval: Specifies the statistics collection and comparison interval for output error packets, in the range of 1 to 65535 seconds.
shutdown: Shuts down an interface when the number of output error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of output error packets exceeds the upper threshold on the interface.
Usage guidelines
With the output error packet alarm function enabled, when the number of output error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of output error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can configure the output error packet alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 5000, lower threshold to 400, and statistics collection and comparison interval to 6 seconds for output error packet alarms on HundredGigE 1/0/1.
<Sysname> system-view
[Sysname] interface hundredgige 1/0/1
[Sysname-HundredGigE1/0/1] port ifmonitor output-error high-threshold 5000 low-threshold 400 interval 6
Related commands
snmp-agent trap enable ifmonitor
port ifmonitor output-usage
Use port ifmonitor output-usage to configure output bandwidth usage alarm parameters.
Use undo port ifmonitor output-usage to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
port ifmonitor output-usage high-threshold high-value low-threshold low-value
undo port ifmonitor output-usage
Default
An interface uses the global output bandwidth usage alarm parameters.
Views
Ethernet interface view
Predefined user roles
network-admin
context-admin
Parameters
high-threshold high-value: Specifies the upper threshold for output bandwidth usage alarms, in the range of 1 to 100.
low-threshold low-value: Specifies the lower threshold for output bandwidth usage alarms, in the range of 1 to 100.
Usage guidelines
With the output bandwidth usage alarm function enabled, when the output bandwidth usage on an interface in normal state within the most recent statistics polling interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the output bandwidth usage on an interface in the alarm state within the most recent statistics polling interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can use the flow-interval command to set the statistics polling interval.
You can configure the output bandwidth usage alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the output bandwidth usage alarm function.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 9 and lower threshold to 7 for output bandwidth usage alarms on HundredGigE 1/0/1.
<Sysname> system-view
[Sysname] interface hundredgige 1/0/1
[Sysname-HundredGigE1/0/1] port ifmonitor output-usage high-threshold 9 low-threshold 7
Related commands
flow-interval
snmp-agent trap enable ifmonitor
port ifmonitor runt
Use port ifmonitor runt to configure runt packet alarm parameters for an interface.
Use undo port ifmonitor runt to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
port ifmonitor runt high-threshold high-value low-threshold low-value interval interval [ shutdown ]
undo port ifmonitor runt
Default
An interface uses the global runt packet alarm parameters.
Views
Ethernet interface view
Predefined user roles
network-admin
context-admin
Parameters
high-threshold high-value: Specifies the upper threshold for runt packet alarms, in the range of 1 to 4294967295.
low-threshold low-value: Specifies the lower threshold for runt packet alarms, in the range of 1 to 4294967295.
interval interval: Specifies the statistics collection and comparison interval for runt packets, in the range of 1 to 65535 seconds.
shutdown: Shuts down an interface when the number of incoming runt packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface.
Usage guidelines
With the runt packet alarm function enabled, when the number of incoming runt packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of incoming runt packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can configure the runt packet alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 5, lower threshold to 4, and statistics collection and comparison interval to 6 seconds for runt packet alarms on HundredGigE 1/0/1.
<Sysname> system-view
[Sysname] interface hundredgige 1/0/1
[Sysname-HundredGigE1/0/1] port ifmonitor runt high-threshold 5 low-threshold 4 interval 6
Related commands
ifmonitor runt
snmp-agent trap enable ifmonitor
port ifmonitor rx-pause
Use port ifmonitor rx-pause to configure received pause frame alarm parameters for an interface.
Use undo port ifmonitor rx-pause to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
port ifmonitor rx-pause high-threshold high-value low-threshold low-value interval interval
undo port ifmonitor rx-pause
Default
An interface uses the global received pause frame alarm parameters.
Views
Ethernet interface view
Predefined user roles
network-admin
context-admin
Parameters
high-threshold high-value: Specifies the upper threshold for received pause frame alarms, in the range of 1 to 4294967295.
low-threshold low-value: Specifies the lower threshold for received pause frame alarms, in the range of 1 to 4294967295.
interval interval: Specifies the statistics collection and comparison interval for received pause frame packets, in the range of 1 to 65535 seconds.
Usage guidelines
With the received pause frame alarm function enabled, when the number of received pause frame packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of received pause frame packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can configure the received pause frame alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the received pause frame alarm function.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 90, lower threshold to 50, and statistics collection and comparison interval to 5 seconds for received pause frame alarms on HundredGigE 1/0/1.
<Sysname> system-view
[Sysname] interface hundredgige 1/0/1
[Sysname-HundredGigE1/0/1] port ifmonitor rx-pause high-threshold 90 low-threshold 50 interval 5
Related commands
snmp-agent trap enable ifmonitor
port ifmonitor sdh-b1-error
Use port ifmonitor sdh-b1-error to configure SDH-B1 error packet alarm parameters for an interface.
Use undo port ifmonitor sdh-b1-error to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
port ifmonitor sdh-b1-error high-threshold high-value low-threshold low-value interval interval [ shutdown ]
undo port ifmonitor sdh-b1-error
Default
An interface uses the global SDH-B1 error packet alarm parameters.
Views
Ethernet interface view
Predefined user roles
network-admin
context-admin
Parameters
high-threshold high-value: Specifies the upper threshold for SDH-B1 error packet alarms, in the range of 1 to 4294967295 packets.
low-threshold low-value: Specifies the lower threshold for SDH-B1 error packet alarms, in the range of 1 to 4294967295 packets.
interval interval: Specifies the statistics collection and comparison interval for SDH-B1 error packets, in the range of 1 to 65535 seconds.
shutdown: Shuts down an interface when the number of incoming SDH-B1 error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of incoming SDH-B1 error packets exceeds the upper threshold on the interface.
Usage guidelines
With the SDH-B1 error packet alarm function enabled, when the number of incoming SDH-B1 error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of incoming SDH-B1 error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can configure the SDH-B1 error packet alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the SDH-B1 error packet alarm function.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 20, lower threshold to 10, and statistics collection and comparison interval to 10 seconds for SDH-B1 error packet alarms on HundredGigE 1/0/1.
<Sysname> system-view
[Sysname] interface hundredgige 1/0/1
[Sysname-HundredGigE1/0/1] port ifmonitor sdh-b1-error high-threshold 20 low-threshold 10 interval 10
Related commands
snmp-agent trap enable ifmonitor
port ifmonitor sdh-b2-error
Use port ifmonitor sdh-b2-error to configure SDH-B2 error packet alarm parameters for an interface.
Use undo port ifmonitor sdh-b2-error to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
port ifmonitor sdh-b2-error high-threshold high-value low-threshold low-value interval interval [ shutdown ]
undo port ifmonitor sdh-b2-error
Default
An interface uses the global SDH-B2 error packet alarm parameters.
Views
Ethernet interface view
Predefined user roles
network-admin
context-admin
Parameters
high-threshold high-value: Specifies the upper threshold for SDH-B2 error packet alarms, in the range of 1 to 4294967295 packets.
low-threshold low-value: Specifies the lower threshold for SDH-B2 error packet alarms, in the range of 1 to 4294967295 packets.
interval interval: Specifies the statistics collection and comparison interval for SDH-B2 error packets, in the range of 1 to 65535 seconds.
shutdown: Shuts down an interface when the number of incoming SDH-B2 error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of incoming SDH-B2 error packets exceeds the upper threshold on the interface.
Usage guidelines
With the SDH-B2 error packet alarm function enabled, when the number of incoming SDH-B2 error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of incoming SDH-B2 error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can configure the SDH-B2 error packet alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the SDH-B2 error packet alarm function.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 10, lower threshold to 8, and statistics collection and comparison interval to 3 seconds for SDH-B2 error packet alarms on HundredGigE 1/0/1.
<Sysname> system-view
[Sysname] interface hundredgige 1/0/1
[Sysname-HundredGigE1/0/1] port ifmonitor sdh-b2-error high-threshold 10 low-threshold 8 interval 3
Related commands
snmp-agent trap enable ifmonitor
port ifmonitor sdh-error
Use port ifmonitor sdh-error to configure SDH error packet alarm parameters for an interface.
Use undo port ifmonitor sdh-error to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
port ifmonitor sdh-error high-threshold high-value low-threshold low-value interval interval [ shutdown ]
undo port ifmonitor sdh-error
Default
An interface uses the global SDH error packet alarm parameters.
Views
Ethernet interface view
Predefined user roles
network-admin
context-admin
Parameters
high-threshold high-value: Specifies the upper threshold for SDH error packet alarms, in the range of 1 to 4294967295 packets.
low-threshold low-value: Specifies the lower threshold for SDH error packet alarms, in the range of 1 to 4294967295 packets.
interval interval: Specifies the statistics collection and comparison interval for SDH error packets, in the range of 1 to 65535 seconds.
shutdown: Shuts down an interface when the number of incoming SDH error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of incoming SDH error packets exceeds the upper threshold on the interface.
Usage guidelines
With the SDH error packet alarm function enabled, when the number of incoming SDH error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of incoming SDH error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can configure the SDH error packet alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the SDH error packet alarm function.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 50, lower threshold to 30, and statistics collection and comparison interval to 10 seconds for SDH error packet alarms on HundredGigE 1/0/1.
<Sysname> system-view
[Sysname] interface hundredgige 1/0/1
[Sysname-HundredGigE1/0/1] port ifmonitor sdh-error high-threshold 50 low-threshold 30 interval 10
Related commands
snmp-agent trap enable ifmonitor
port ifmonitor tx-pause
Use port ifmonitor tx-pause to configure sent pause frame alarm parameters for an interface.
Use undo port ifmonitor tx-pause to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
port ifmonitor tx-pause high-threshold high-value low-threshold low-value interval interval
undo port ifmonitor tx-pause
Default
An interface uses the global sent pause frame alarm parameters.
Views
Ethernet interface view
Predefined user roles
network-admin
context-admin
Parameters
high-threshold high-value: Specifies the upper threshold for sent pause frame alarms, in the range of 1 to 4294967295.
low-threshold low-value: Specifies the lower threshold for sent pause frame alarms, in the range of 1 to 4294967295.
interval interval: Specifies the statistics collection and comparison interval for sent pause frame packets, in the range of 1 to 65535 seconds.
Usage guidelines
With the sent pause frame alarm function enabled, when the number of sent pause frame packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of sent pause frame packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.
You can configure the sent pause frame alarm parameters in system view and interface view.
· The configuration in system view takes effect on all interfaces of the specified slot. The configuration in interface view takes effect only on the current interface.
· For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.
For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the sent pause frame alarm function.
When you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the upper threshold to 50, lower threshold to 40, and statistics collection and comparison interval to 8 seconds for sent pause frame alarms on HundredGigE 1/0/1.
<Sysname> system-view
[Sysname] interface hundredgige 1/0/1
[Sysname-HundredGigE1/0/1] port ifmonitor tx-pause high-threshold 50 low-threshold 40 interval 8
Related commands
snmp-agent trap enable ifmonitor
port link-mode
Use port link-mode to change the link mode of an Ethernet interface.
Use undo port link-mode to restore the default.
Syntax
port link-mode { bridge | route }
undo port link-mode
Default
An Ethernet interface operates in Layer 2 mode.
Views
Ethernet interface view
Predefined user roles
network-admin
Parameters
bridge: Specifies the Layer 2 mode.
route: Specifies the Layer 3 mode.
Usage guidelines
CAUTION: Changing the link mode of an Ethernet interface also restores all commands (except shutdown) on the Ethernet interface to their defaults in the new link mode. |
Ethernet interfaces can operate either as Layer 2 or Layer 3 Ethernet interfaces. You can use this command to set the link mode to bridge or route for these Ethernet interfaces.
Before switching the link mode or executing the default command for an Ethernet interface, first delete all settings of the interface to ensure successful link mode switchover.
Examples
# Configure Ten-GigabitEthernet 1/0/1 to operate in Layer 2 mode.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] port link-mode bridge
Related commands
default
priority-flow-control (Ethernet interface view)
Use priority-flow-control to enable PFC in auto mode or forcibly.
Use undo priority-flow-control to disable PFC.
Syntax
priority-flow-control { auto | enable }
undo priority-flow-control
Default
PFC is disabled on Ethernet interfaces.
Views
Ethernet interface view
Predefined user roles
network-admin
Parameters
auto: Specifies PFC in auto mode. In this mode, the local end automatically negotiates the PFC status with its peer.
enable: Forcibly enables PFC.
Usage guidelines
The local device notifies the remote end to stop sending packets carrying the specified 802.1p priority if all of the following conditions exist:
· Both the local end and the remote end have PFC enabled.
· Both the local end and the remote end have the priority-flow-control no-drop dot1p command configured.
· The specified 802.1p priority is in the 802.1p priority list specified by the dot1p-list argument.
· The local end receives packets carrying the specified 802.1p priority, and the received packets cause congestion.
When congestion is eliminated, the local end notifies the remote end to continue to send packets carrying the specified 802.1p priority. In this way, the local device can forward packets carrying 802.1p priorities in the specified 802.1p priority list without packet drops.
You can configure PFC in both system view and Ethernet interface view. If you configure PFC in system view, PFC is issued to all interfaces. If you configure PFC in system view and Ethernet interface view multiple times, the most recent configuration takes effect.
Examples
# Enable PFC on Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] priority-flow-control enable
Related commands
display priority-flow-control
priority-flow-control (system view)
priority-flow-control no-drop dot1p
priority-flow-control (system view)
Use priority-flow-control to enable PFC on all Ethernet interfaces.
Use undo priority-flow-control to disable PFC on all Ethernet interfaces.
Syntax
priority-flow-control { auto | enable }
undo priority-flow-control
Default
PFC is disabled on Ethernet interfaces.
Views
System view
Predefined user roles
network-admin
Parameters
auto: Specifies PFC in auto mode. In this mode, the local end automatically negotiates the PFC status with the remote end.
enable: Forcibly enables PFC.
Usage guidelines
The local device notifies the remote end to stop sending packets carrying the specified 802.1p priority if all of the following conditions exist:
· Both the local end and the remote end have PFC enabled.
· Both the local end and the remote end have the priority-flow-control no-drop dot1p command configured.
· The specified 802.1p priority is in the 802.1p priority list specified by the dot1p-list argument.
· The local end receives packets carrying the specified 802.1p priority, and the received packets cause congestion.
When congestion is eliminated, the local end notifies the remote end to continue to send packets carrying the specified 802.1p priority. In this way, the local device can forward packets carrying 802.1p priorities in the specified 802.1p priority list without packet drops.
You can configure PFC in both system view and Ethernet interface view. If you configure PFC in system view, PFC is issued to all interfaces. If you configure PFC in system view and Ethernet interface view multiple times, the most recent configuration takes effect.
Examples
# Enable PFC on all Ethernet interfaces.
<Sysname> system-view
[Sysname] priority-flow-control enable
Related commands
display priority-flow-control
priority-flow-control (Ethernet interface view)
priority-flow-control no-drop dot1p
priority-flow-control deadlock auto-recover action
Use priority-flow-control deadlock auto-recover action to configure the action to take on packets during the delay timer period for PFC deadlock detection recovery.
Use undo priority-flow-control deadlock auto-recover action to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
priority-flow-control deadlock auto-recover action { discard | forwarding }
undo priority-flow-control deadlock auto-recover action
Default
The device forwards received data packets.
Views
System view
Predefined user roles
network-admin
Parameters
discard: Drops the received data packets.
forwarding: Forwards the received data packets.
Usage guidelines
This command cannot be executed when the device is in PFC deadlock status.
Examples
# Configure the device to drop received data packets during the delay timer period for PFC deadlock detection automatic recovery.
<Sysname> system-view
[Sysname] priority-flow-control deadlock auto-recover action discard
Related commands
priority-flow-control deadlock cos
priority-flow-control deadlock enable
priority-flow-control deadlock auto-recover cos
Use priority-flow-control deadlock auto-recover cos to configure the delay timer for PFC deadlock detection automatic recovery.
Use undo priority-flow-control deadlock auto-recover cos to delete the delay timer for PFC deadlock detection automatic recovery.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
priority-flow-control deadlock auto-recover slot slot-number cos cos-value delay delay-interval
undo priority-flow-control deadlock auto-recover slot slot-number cos [ cos-value ]
Default
The delay timer for PFC deadlock detection automatic recovery is not configured.
Views
System view
Predefined user roles
network-admin
Parameters
cos cos-value: Specifies the CoS value of packets, in the range of 0 to 7. Different CoS values correspond to different 802.1p priority values. To see the CoS-to-802.1p mapping, execute the display qos map-table dot1p-lp command.
delay delay-time: Specifies the delay timer for PFC deadlock detection automatic recovery, in the range of 0 to 15.
slot slot-number: Specifies a card by its slot number, which is fixed at 1.
Usage guidelines
PFC deadlock detection periodically detects whether deadlock occurs to packets carrying the specified CoS value. If the device enters the PFC deadlock state and PFC deadlock detection is recovered in automatic mode, the device automatically recovers PFC deadlock detection after the delay timer expires. The delay timer is determined by this command and the PFC deadlock detection timer precision.
This command takes effect only in automatic recovery mode. This command cannot be executed when the device is in PFC deadlock status.
The specified CoS value must be within the 802.1p priority values configured by using the priority-flow-control no-drop dot1p command.
You can set the same delay timer for different CoS values.
If you execute this command multiple times for the same CoS value, the most recent configuration takes effect.
Examples
# Set the delay timer for PFC deadlock detection automatic recovery to 5 for packets carrying CoS value 7.
<Sysname> system-view
[Sysname] priority-flow-control deadlock auto-recover slot 1 cos 7 delay 5
Related commands
display qos map-table dot1p-lp (ACL and QoS Command Reference)
priority-flow-control deadlock precision
priority-flow-control no-drop dot1p
priority-flow-control deadlock cos
Use priority-flow-control deadlock cos to set the PFC deadlock detection interval for the specified CoS value.
Use undo priority-flow-control deadlock cos to delete the PFC deadlock detection interval for the specified CoS value or all CoS values.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
priority-flow-control deadlock slot slot-number cos cos-value interval interval
undo priority-flow-control deadlock slot slot-number cos [ cos-value ]
Default
The PFC deadlock detection interval for a CoS value is not set.
Views
System view
Predefined user roles
network-admin
Parameters
cos cos-value: Specifies the CoS value of packets, in the range of 0 to 7.
interval interval: Specifies the PFC deadlock detection interval in the range of 1 to 15.
slot slot-number: Specifies a card by its slot number, which is fixed at 1.
Usage guidelines
The PFC deadlock detection feature periodically detects whether deadlock occurs to packets that carry the specified CoS value. To obtain the length of time for the detection interval, multiply the detection interval by the precision of the PFC deadlock detection timer.
The specified CoS value must be within the 802.1p priority list specified by using the priority-flow-control no-drop dot1p command. To view the 802.1p priority for each CoS value, execute the display qos map-table dot1p-lp command.
You can set the same detection interval for different CoS values.
If you execute this command for the same CoS value multiple times, the most recent configuration takes effect.
This command cannot be executed when the device is in PFC deadlock status.
Examples
# Set the PFC deadlock detection interval to 5 for packets carrying CoS value 7 on slot 1.
<Sysname> system-view
[Sysname] priority-flow-control deadlock slot 1 cos 7 interval 5
Related commands
display qos map-table dot1p-lp (ACL and QoS Command Reference)
priority-flow-control deadlock precision
priority-flow-control no-drop dot1p
priority-flow-control deadlock enable
Use priority-flow-control deadlock enable to enable PFC deadlock detection on an interface.
Use undo priority-flow-control deadlock enable to disable PFC deadlock detection on an interface.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
priority-flow-control deadlock enable
undo priority-flow-control deadlock enable
Default
PFC deadlock detection is disabled on an interface.
Views
Ethernet interface view
Predefined user roles
network-admin
Usage guidelines
The device enters the PFC deadlock state if the following conditions exist on an interface:
· PFC for 802.1p priorities is enabled by using the priority-flow-control and priority-flow-control no-drop dot1p commands.
· Packets carrying the specified 802.1p priority are transmitted in a loop.
· No packets in the data buffer can be forwarded.
This command enables periodically detecting whether the device is in PFC deadlock state.
This command cannot be executed when the device is in PFC deadlock status.
Examples
# Enable PFC deadlock detection on Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] priority-flow-control deadlock enable
Related commands
priority-flow-control
priority-flow-control deadlock cos
priority-flow-control no-drop dot1p
priority-flow-control deadlock precision
Use priority-flow-control deadlock precision to set the precision for the PFC deadlock detection timer.
Use undo priority-flow-control deadlock precision to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
priority-flow-control deadlock slot slot-number precision { high | low | normal }
undo priority-flow-control deadlock slot slot-number precision
Default
The PFC deadlock detection timer uses normal precision.
Views
System view
Predefined user roles
network-admin
Parameters
high: Specifies the high precision for the PFC deadlock detection timer, which represents one second.
low: Specifies the low precision for the PFC deadlock detection timer, which represents three seconds.
normal: Specifies the normal precision for the PFC deadlock detection timer, which represents two seconds.
slot slot-number: Specifies a card by its slot number, which is fixed at 1.
Usage guidelines
Use this command to adjust the precision for the PFC deadlock detection timer and change the PFC deadlock detection interval.
If you execute this command multiple times, the most recent configuration takes effect.
This command cannot be executed when the device is in PFC deadlock status.
Examples
# Set the high precision for the PFC deadlock detection timer on slot 1.
<Sysname> system-view
[Sysname] priority-flow-control deadlock slot 1 precision high
priority-flow-control deadlock recover
Use priority-flow-control deadlock recover to recover PFC deadlock detection on an interface.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
priority-flow-control deadlock recover
Views
Ethernet interface view
Predefined user roles
network-admin
Usage guidelines
Before executing this command, you must use the priority-flow-control deadlock recover-mode command to set the recovery mode for PFC deadlock detection.
The device can automatically release the deadlock state, but both the PFC deadlock detection and PFC features are disabled on the interface at the same time. To manually recover PFC deadlock detection on the interface, execute this command after setting the manual recovery mode for PFC deadlock detection on the interface. The PFC feature is also enabled again when you execute this command.
This command cannot be executed when the device is in PFC deadlock status.
Examples
# Recover PFC deadlock detection on Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] priority-flow-control deadlock recover
Related commands
priority-flow-control deadlock recover-mode
priority-flow-control deadlock recover-mode
Use priority-flow-control deadlock recover-mode to set the recovery mode for PFC deadlock detection on an interface.
Use undo priority-flow-control deadlock recover-mode to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
priority-flow-control deadlock recover-mode { auto | manual }
undo priority-flow-control deadlock recover-mode
Default
PFC deadlock detection recovers in automatic mode on an interface.
Views
Ethernet interface view
Predefined user roles
network-admin
Parameters
auto: Specifies the automatic recovery mode.
manual: Specifies the manual recovery mode.
Usage guidelines
When the PFC deadlock state is detected and PFC deadlock detection is recovered in automatic mode, the device automatically releases the deadlock state and recovers PFC and PFC deadlock detection after the delay timer expires. Within the delay timer period, the device disables PFC and PFC deadlock detection on the interface, so that packets can be forwarded properly. PFC deadlock detection can be recovered in automatic or manual mode on the interface. Recovering this feature enables the PFC feature again at the same time. Use the automatic recovery mode when no serious failures occur.
When a packet loop cannot be resolved and the device enters the PFC deadlock state frequently, manually recover PFC deadlock detection on the interface as follows:
1. Perform troubleshooting and set the manual recovery mode for PFC deadlock detection.
2. Execute the priority-flow-control deadlock recover command to recover the PFC deadlock detection and PFC features.
This command cannot be executed when the device is in PFC deadlock status.
Examples
# Set the manual recovery mode for PFC deadlock detection on Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] priority-flow-control deadlock recover-mode manual
Related commands
priority-flow-control deadlock recover
priority-flow-control deadlock threshold
Use priority-flow-control deadlock threshold to configure the upper threshold for PFC deadlock times within the specified period.
Use undo priority-flow-control deadlock threshold to restore the default.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
priority-flow-control deadlock threshold slot slot-number cos cos-value period period count count
undo priority-flow-control deadlock threshold slot slot-number cos [ cos-value ]
Default
The upper threshold for PFC deadlock times within the specified period is not configured.
Views
System view
Predefined user roles
network-admin
Parameters
cos cos-value: Specifies the CoS value of packets, in the range of 0 to 7. Different CoS values correspond to different 802.1p priority values. To see the CoS-to-802.1p mapping, execute the display qos map-table dot1p-lp command.
period period: Specifies the period for detecting PFC deadlock times, in the range of 1 to 60 seconds.
count count: Specifies the upper threshold for PFC deadlock times within the specified period, in the range of 1 to 500.
slot slot-number: Specifies a card by its slot number.
Usage guidelines
With this command configured, when the PFC deadlock times within the specified period exceed the upper threshold on an interface, the device disables PFC for all 802.1p priority values on the interface. To recover the PFC feature on the interface in this case, execute the undo priority-flow-control deadlock threshold command.
The detection period specified in this command must be longer than the PFC deadlock detection interval configured by using the priority-flow-control deadlock cos command, so that you can determine whether the device frequently enters the PFC deadlock state.
This command cannot be executed when the device is in PFC deadlock status.
The specified CoS value must be within the 802.1p priority values configured by using the priority-flow-control no-drop dot1p command.
You can set the same detection period for different CoS values.
If you execute this command multiple times for the same CoS value, the most recent configuration takes effect.
Examples
# Set the upper threshold for PFC deadlock times to 100 within the period of 5 seconds.
<Sysname> system-view
[Sysname] priority-flow-control deadlock threshold slot 1 cos 7 period 5 count 100
Related commands
priority-flow-control deadlock cos
priority-flow-control no-drop dot1p
priority-flow-control early-warning inpps
Use priority-flow-control early-warning inpps to configure the early warning threshold for incoming PFC packets.
Use undo priority-flow-control early-warning inpps to delete the early warning threshold for incoming PFC packets.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
priority-flow-control early-warning dot1p dot1p-list inpps pps-value
undo priority-flow-control early-warning [ dot1p dot1p-list ] inpps
Default
No early warning threshold is configured for incoming PFC packets.
Views
Ethernet interface view
Predefined user roles
network-admin
Parameters
dot1p-list: Specifies an 802.1p priority (or dot1p priority) list to identify flows that are subject to PFC (for example: 1,3-5). A hyphen (-) connects two numeric values, which together indicate a continuous value range. Different values or value ranges are separated with commas (,). You can configure up to 16 characters for this argument.
inpps pps-value: Specifies the number of PFC frames that an interface can receive in pps. The value range for this argument is 1 to 159783010.
Usage guidelines
You can configure the early warning threshold for incoming or outgoing PFC packets of an interface as needed. The early warning threshold notifies a situation where the PFC packet transmission rate is still within a normal range but needs attention.
When the rate of PFC packets that an interface sends or receives reaches the early warning threshold, the system generates traps and logs to notify the user. According to the traps and logs, the user can discover some exceptions in the network, for example:
· The NIC of the peer device fails and continuously sends PFC packets at a high speed. In this case, you can set the early warning threshold for incoming PFC packets.
· The device fails and continuously sends PFC frames. In this case, you can set the early warning threshold for outgoing PFC packets.
To monitor bidirectional PFC packets, you can set the early warning thresholds for incoming packets and outgoing packets separately.
The number of PFC pause frames that an interface receives is counted and the early warning threshold configuration takes effect only when PFC is enabled.
If you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the early warning threshold to 80 pps for incoming PFC packets with 802.1p priority value 7 on Ten-GigabitEthernet 1/0/1.
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] priority-flow-control early-warning dot1p 7 inpps 80
priority-flow-control early-warning outpps
Use priority-flow-control early-warning outpps to configure the early warning threshold for outgoing PFC packets.
Use undo priority-flow-control early-warning outpps to delete the early warning threshold for outgoing PFC packets.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
priority-flow-control early-warning dot1p dot1p-list outpps pps-value
undo priority-flow-control early-warning [ dot1p dot1p-list ] outpps
Default
No early warning threshold is configured for outgoing PFC packets.
Views
Ethernet interface view
Predefined user roles
network-admin
Parameters
dot1p-list: Specifies an 802.1p priority (or dot1p priority) list to identify flows that are subject to PFC (for example: 1,3-5). A hyphen (-) connects two numeric values, which together indicate a continuous value range. Different values or value ranges are separated with commas (,). You can configure up to 16 characters for this argument.
outpps pps-value: Specifies the number of PFC frames that an interface can send in pps. The value range for this argument is 1 to 159783010.
Usage guidelines
You can configure the early warning threshold for incoming or outgoing PFC packets of an interface as needed. The early warning threshold notifies a situation where the PFC packet transmission rate is still within a normal range but needs attention.
When the rate of PFC packets that an interface sends or receives reaches the early warning threshold, the system generates traps and logs to notify the user. According to the traps and logs, the user can discover some exceptions in the network, for example:
· The NIC of the peer device fails and continuously sends PFC packets at a high speed. In this case, you can set the early warning threshold for incoming PFC packets.
· The device fails and continuously sends PFC frames. In this case, you can set the early warning threshold for outgoing PFC packets.
To monitor bidirectional PFC packets, you can set the early warning thresholds for incoming packets and outgoing packets separately.
The number of PFC pause frames that an interface sends is counted and the early warning threshold configuration takes effect only when PFC is enabled.
If you execute this command multiple times, the most recent configuration takes effect.
Examples
# Set the early warning threshold to 50 pps for outgoing PFC packets with 802.1p priority value 1 on Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] priority-flow-control early-warning dot1p 1 outpps 50
priority-flow-control no-drop dot1p (Ethernet interface view)
Use priority-flow-control no-drop dot1p to enable PFC for 802.1p priorities.
Use undo priority-flow-control no-drop dot1p to disable PFC for the specified 802.1p priority.
Syntax
priority-flow-control no-drop dot1p dot1p-list
undo priority-flow-control no-drop dot1p
Default
PFC is disabled for all 802.1p priorities.
Views
Ethernet interface view
Predefined user roles
network-admin
Parameters
dot1p-list: Specifies an 802.1p priority (or dot1p priority) list to identify flows that are subject to PFC (for example: 1,3-5). A hyphen (-) connects two numeric values, which together indicate a continuous value range. Different values or value ranges are separated with commas (,). You can configure up to 16 characters for this argument.
Usage guidelines
The local device notifies the remote end to stop sending packets carrying the specified 802.1p priority if all of the following conditions exist:
· Both the local end and the remote end have PFC enabled.
· Both the local end and the remote end have the priority-flow-control no-drop dot1p command configured.
· The specified 802.1p priority is in the 802.1p priority list specified by the dot1p-list argument.
· The local end receives packets carrying the specified 802.1p priority, and the received packets cause congestion.
When congestion is eliminated, the local end notifies the remote end to continue to send packets carrying the specified 802.1p priority. In this way, the local device can forward packets carrying 802.1p priorities in the specified 802.1p priority list without packet drops. For more information about the 802.1p priority, see ACL and QoS Configuration Guide.
This command is mutually exclusive with the flow-control or flow-control receive enable command.
You can configure PFC in both system view and Ethernet interface view. If you configure PFC in system view, PFC is issued to all interfaces. If you configure PFC in system view and Ethernet interface view multiple times, the most recent configuration takes effect.
Examples
# Enable PFC in auto mode on Ten-GigabitEthernet 1/0/1, and enable PFC for 802.1p priority 5.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] priority-flow-control auto
[Sysname-Ten-GigabitEthernet1/0/1] priority-flow-control no-drop dot1p 5
Related commands
display priority-flow-control
flow-control
flow-control receive enable
priority-flow-control
priority-flow-control no-drop dot1p (system view)
priority-flow-control no-drop dot1p (system view)
Use priority-flow-control no-drop dot1p to enable PFC for 802.1p priorities on all Ethernet interfaces.
Use undo priority-flow-control no-drop dot1p to disable PFC for 802.1p priorities on all Ethernet interfaces.
Syntax
priority-flow-control no-drop dot1p dot1p-list
undo priority-flow-control no-drop dot1p
Default
PFC is disabled for all 802.1p priorities on all Ethernet interfaces.
Views
System view
Predefined user roles
network-admin
Parameters
dot1p-list: Specifies an 802.1p priority (or dot1p priority) list to identify flows that are subject to PFC (for example: 1,3-5). A hyphen (-) connects two numeric values, which together indicate a continuous value range. Different values or value ranges are separated with commas (,). You can configure up to 16 characters for this argument.
Usage guidelines
The local device notifies the remote end to stop sending packets carrying the specified 802.1p priority if all of the following conditions exist:
· Both the local end and the remote end have PFC enabled.
· Both the local end and the remote end have the priority-flow-control no-drop dot1p command configured.
· The specified 802.1p priority is in the 802.1p priority list specified by the dot1p-list argument.
· The local end receives packets carrying the specified 802.1p priority, and the received packets cause congestion.
When congestion is eliminated, the local end notifies the remote end to continue to send packets carrying the specified 802.1p priority. In this way, the local device can forward packets carrying 802.1p priorities in the specified 802.1p priority list without packet drops. For more information about the 802.1p priority, see ACL and QoS Configuration Guide.
You can configure PFC in both system view and Ethernet interface view. If you configure PFC in system view, PFC is issued to all interfaces. If you configure PFC in system view and Ethernet interface view multiple times, the most recent configuration takes effect.
Examples
# Enable PFC for 802.1p priority 5 globally.
<Sysname> system-view
[Sysname] priority-flow-control no-drop dot1p 5
Related commands
display priority-flow-control
priority-flow-control
priority-flow-control no-drop dot1p (Ethernet interface view)
reset counters interface
Use reset counters interface to clear the interface statistics.
Syntax
reset counters interface [ interface-type [ interface-number | interface-number.subnumber ] ]
Views
User view
Predefined user roles
network-admin
Parameters
interface-type: Specifies an interface type.
interface-number: Specifies an interface number.
interface-number.subnumber: Specifies a subinterface number. The interface-number argument is an interface number. The subnumber argument is the number of a subinterface created under the interface. The value range for the subnumber argument is 1 to 4094.
Usage guidelines
Use this command to clear history statistics if you want to collect traffic statistics for a specific time period.
If you do not specify an interface type, this command clears statistics for all interfaces.
If you specify an interface type but do not specify an interface number, this command clears statistics for all interfaces of the specified type.
Examples
# Clear the statistics for Ten-GigabitEthernet 1/0/1.
<Sysname> reset counters interface ten-gigabitethernet 1/0/1
Related commands
display counters interface
display counters rate interface
display interface
reset ethernet statistics
Use reset ethernet statistics to clear the Ethernet module statistics.
Syntax
reset ethernet statistics [ slot slot-number ]
Views
User view
Predefined user roles
network-admin
Parameters
slot slot-number: Specifies the slot number of the device, which is fixed at 1.
Examples
# Clear the Ethernet module statistics for the specified slot.
<Sysname> reset ethernet statistics slot 1
Related commands
display ethernet statistics
reset packet-drop interface
Use reset packet-drop interface to clear the dropped packet statistics for an interface.
Syntax
reset packet-drop interface [ interface-type [ interface-number ] ]
Views
User view
Predefined user roles
network-admin
Parameters
interface-type: Specify an interface type. If you do not specify an interface type, this command clears dropped packet statistics for all interfaces on the device.
interface-number: Specify an interface number. If you do not specify this argument, the command clears dropped packet statistics for all interfaces of the specified type.
Examples
# Clear dropped packet statistics for Ten-GigabitEthernet 1/0/1.
<Sysname> reset packet-drop interface ten-gigabitethernet 1/0/1
# Clear dropped packet statistics for all interfaces.
<Sysname> reset packet-drop interface
Related commands
display packet-drop
shutdown
Use shutdown to shut down an Ethernet interface or subinterface.
Use undo shutdown to bring up an Ethernet interface or subinterface.
Syntax
shutdown
undo shutdown
Default
An Ethernet interface or subinterface is down.
Views
Ethernet interface view
Ethernet subinterface view
Predefined user roles
network-admin
Usage guidelines
CAUTION: Executing the shutdown command on an interface will disconnect the link of the interface and interrupt communication. Use this command with caution. |
Some interface configurations might require an interface restart before taking effect.
The shutdown, port up-mode, and loopback commands are mutually exclusive.
Examples
# Shut down and then bring up Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] shutdown
[Sysname-Ten-GigabitEthernet1/0/1] undo shutdown
# Shut down and then bring up Ten-GigabitEthernet 1/0/1.1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1.1
[Sysname-Ten-GigabitEthernet1/0/1.1] shutdown
[Sysname-Ten-GigabitEthernet1/0/1.1] undo shutdown
snmp-agent trap enable ifmonitor
Use snmp-agent trap enable ifmonitor to enable interface alarm functions.
Use undo snmp-agent trap enable ifmonitor to disable interface alarm functions.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
snmp-agent trap enable ifmonitor [ crc-error | giant | input-error | input-usage | output-error | output-usage | runt | rx-pause | sdh-b1-error | sdh-b2-error | sdh-error | tx-pause ] *
undo snmp-agent trap enable ifmonitor [ crc-error | input-error | input-usage | output-error | output-usage | rx-pause | sdh-b1-error | sdh-b2-error | sdh-error | tx-pause ] *
Default
Interface alarm functions are enabled.
Views
System view
Predefined user roles
network-admin
Parameters
crc-error: Enables the CRC error packet alarm function for interfaces.
giant: Enables the giant packet alarm function for interfaces.
input-error: Enables the input error packet alarm function for interfaces.
input-usage: Enables the input bandwidth usage alarm function for interfaces.
output-error: Enables the output error packet alarm function for interfaces.
output-usage: Enables the output bandwidth usage alarm function for interfaces.
runt: Enables the runt packet alarm function for interfaces.
rx-pause: Enables the received pause frame alarm function for interfaces.
sdh-b1-error: Enables the SDH-B1 error packet alarm function for interfaces.
sdh-b2-error: Enables the SDH-B2 error packet alarm function for interfaces.
sdh-error: Enables the SDH error packet alarm function for interfaces.
tx-pause: Enables the sent pause frame alarm function for interfaces.
Examples
# Enable the CRC error packet alarm function for interfaces.
<Sysname> system-view
[Sysname] snmp-agent trap enable ifmonitor crc-error
speed
Use speed to set the speed of an Ethernet interface.
Use undo speed to restore the default.
Syntax
speed { 10 | 100 | 1000 | 10000 | 40000 | 100000 | auto }
undo speed
Default
The speed of an Ethernet interface is autonegotiated.
Views
Ethernet interface view
Predefined user roles
network-admin
Parameters
10: Sets the interface speed to 10 Mbps.
100: Sets the interface speed to 100 Mbps.
1000: Sets the interface speed to 1000 Mbps.
10000: Sets the interface speed to 10000 Mbps.
40000: Sets the interface speed to 40000 Mbps.
100000: Sets the interface speed to 100000 Mbps.
auto: Enables the interface to negotiate a speed with its peer.
Usage guidelines
On an S6890-44HF switch, 10-GE interfaces numbered 37 through 40 do not support 1-Gbps transceiver modules.
For an Ethernet copper port, use the speed command to set its speed to match the speed of the peer interface. Support of copper ports for keywords of this command varies by copper port type. For more information, use the speed ? command in interface view. If the system does not prompt that operation failed when you configure a speed for a copper port, the copper port supports this speed. Otherwise, the copper port does not support this speed.
For a fiber port, use the speed command to set its speed to match the rate of a transceiver module. Support of fiber ports for keywords of this command varies by fiber port type. For more information, use the speed ? command in interface view. If the system does not prompt that operation failed when you configure a speed for a fiber port, the fiber port supports this speed. Otherwise, the fiber port does not support this speed.
Additionally, you must select a speed for a fiber port according to the transceiver module installed to ensure that the transceiver module can be used properly. If the transceiver module installed in a fiber port does not support the speed for the fiber port, the transceiver module cannot be used. For example, the transceiver module cannot be used if either of the following conditions exists:
· The transceiver module installed in an SFP+ fiber port is an SFP GE transceiver module and the speed 10000 command is executed on the fiber port.
· The transceiver module installed in an SFP+ fiber port is a 10-GE transceiver module and the speed 1000 command is executed on the fiber port.
Examples
# Configure Ten-GigabitEthernet 1/0/1 to autonegotiate the speed.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] speed auto
unicast-suppression
Use unicast-suppression to enable unknown unicast storm suppression and set the unknown unicast storm suppression threshold.
Use undo unicast-suppression to disable unknown unicast storm suppression.
Syntax
unicast-suppression { ratio | pps max-pps | kbps max-kbps }
undo unicast-suppression
Default
Ethernet interfaces do not suppress unknown unicast traffic.
Views
Ethernet interface view
Predefined user roles
network-admin
Parameters
ratio: Sets the unknown unicast suppression threshold as a percentage of the interface bandwidth. The value range for this argument (in percentage) is 0 to 100. A smaller value means that less unknown unicast traffic is allowed to pass through.
pps max-pps: Specifies the maximum number of unknown unicast packets that the interface can forward per second. The value range for the max-pps argument (in pps) is 0 to 1.4881 × the interface bandwidth.
kbps max-kbps: Specifies the maximum number of kilobits of unknown unicast traffic that the Ethernet interface can forward per second. The value range for this argument (in kbps) is 0 to the interface bandwidth.
Usage guidelines
The unknown unicast storm suppression feature limits the size of unknown unicast traffic to a threshold on an interface. When the unknown unicast traffic on the interface exceeds this threshold, the system discards packets until the unknown unicast traffic drops below this threshold.
Both the storm-constrain command and the unicast-suppression command can suppress unknown unicast storms on a port. The unicast-suppression command uses the chip to physically suppress unknown unicast traffic. It has less influence on the device performance than the storm-constrain command, which uses software to suppress unknown unicast traffic.
For the unknown unicast traffic suppression result to be determined, do not configure both the storm-constrain unicast command and the unicast-suppression command on an interface.
When you configure the suppression threshold in kbps, the actual suppression threshold might be different from the configured one as follows:
· If the configured value is smaller than 64, the value of 64 takes effect.
· If the configured value is greater than 64 but not an integer multiple of 64, the integer multiple of 64 that is greater than and closest to the configured value takes effect.
For the suppression threshold that takes effect, see the prompt on the device.
Examples
# Set the unknown unicast storm suppression threshold to 10000 kbps on Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] unicast-suppression kbps 10000
The actual value is 10048 on port Ten-GigabitEthernet1/0/1 currently.
The output shows that the value that takes effect is 10048 kbps (157 times of 64), because the chip only supports step 64.
Related commands
broadcast-suppression
multicast-suppression
using hundredgige
Use using hundredgige to combine 10-GE breakout interfaces split from a 100-GE interface into a 100-GE interface.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
using hundredgige
Default
The 10-GE breakout interfaces are not combined and operate as single interfaces.
Views
10-GE breakout interface view
Predefined user roles
network-admin
Usage guidelines
If you need higher bandwidth on a single interface, you can combine four 10-GE breakout interfaces split from a 100-GE interface into a 100-GE interface. To do so, execute this command on any of these 10-GE breakout interfaces.
After you execute this command, execute the display interface brief command to view the combined interfaces.
Examples
# Combine Ten-GigabitEthernet 1/0/1:1 through Ten-GigabitEthernet 1/0/1:10 into a 100-GE interface.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1:1
[Sysname-Ten-GigabitEthernet1/0/1:1]using hundredgige
The interfaces Ten-GigabitEthernet1/0/1:1 through Ten-GigabitEthernet1/0/1:10 will be deleted. Continue? [Y/N]:y
Related commands
using tengige
using tengige
Use using tengige to split a high bandwidth interface into multiple 10-GE breakout interfaces.
|
NOTE: This command is supported only in R3608 and later. |
Syntax
using tengige
Default
A high bandwidth interface is not split and operates as a single interface.
Views
100-GE interface view
Predefined user roles
network-admin
Usage guidelines
To improve port density, reduce costs, and improve network flexibility, you can split a high bandwidth interface into multiple 10-GE breakout interfaces. For example, split a 100-GE interface HundredGigE 1/0/1 installed with a split-capable 40-GE transceiver module or cable into four 10-GE breakout interfaces Ten-GigabitEthernet 1/0/1:1 through Ten-GigabitEthernet 1/0/1:4.
The 10-GE breakout interfaces support the same configuration and attributes as common 10-GE interfaces, except that they are numbered in a different way.
After you execute this command, execute the display interface brief command to view the breakout interfaces.
Before a 100-GE interface on an S6890 switch is split, it supports eight queues numbered 0 through 7. After such a 100-GE interface is split, each breakout interface supports two queues and does not support PFC-related features.
Examples
# Split HundredGigE 1/0/1 into four 10-GE breakout interfaces.
<Sysname> system-view
[Sysname] interface hundredgige 1/0/1
[Sysname-HundredGigE1/0/1] using tengige
The interface HundredGigE1/0/1 will be deleted. Continue? [Y/N]:y
Related commands
using hundredgige
Layer 2 Ethernet interface commands
display storm-constrain
Use display storm-constrain to display storm control settings and statistics.
Syntax
display storm-constrain [ broadcast | multicast | unicast ] [ interface interface-type interface-number ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
broadcast: Displays broadcast storm control settings and statistics.
multicast: Displays multicast storm control settings and statistics.
unicast: Displays unknown unicast storm control settings and statistics.
interface interface-type interface-number: Specifies an interface by its type and number. If you do not specify this option, the command displays storm control settings and statistics for all storm control-enabled interfaces.
Usage guidelines
If you do not specify any keywords, this command displays all storm control settings on all storm control-enabled interfaces.
Examples
# Display the storm control settings on all storm control-enabled ports.
<Sysname> display storm-constrain
Abbreviation: BC - broadcast; MC - multicast; UC - unicast
FW - forwarding
Flow Statistic Interval: 5 (in seconds)
Port Type Lower Upper Unit CtrlMode Status Trap Log StateChanges
--------------------------------------------------------------------------------
XGE1/0/1 MC 100 200 kbps shutdown shutdown off on 10
Table 9 Command output
Field |
Description |
Flow Statistic Interval |
Traffic polling interval (in seconds) of the storm control module. |
Port |
Abbreviated interface name. |
Type |
Type of traffic subjected to storm control: · BC—Broadcast packets. · MC—Multicast packets. · UC—Unknown unicast packets. |
Lower |
Lower storm control threshold, in pps, kbps, or percentage. |
Upper |
Upper storm control threshold, in pps, kbps, or percentage. |
Unit |
Storm control threshold unit: · pps. · kbps. · percentage. |
CtrlMode |
Action (block or shutdown) taken on the interface when the upper threshold is reached. N/A indicates that no action is configured. |
Status |
Packet forwarding status: · FW—The port is forwarding traffic correctly. · shutdown—The port has been shut down. · block—The port drops the type of traffic. |
Trap |
Status of the storm control threshold event trap switch: · on—The port sends threshold event traps. · off—The port does not send threshold event traps. |
Log |
Status of the storm control threshold event log switch: · on—The port sends threshold event log messages. · off—The port does not send threshold event log messages. |
StateChanges |
Number of forwarding state changes of the interface. When the StateChanges field reaches 65535, it resets automatically. |
port up-mode
Use port up-mode to forcibly bring up a fiber Ethernet port.
Use undo port up-mode to restore the default.
Syntax
port up-mode
undo port up-mode
Default
A fiber Ethernet port is not forcibly brought up. The physical state of a fiber port depends on the physical state of the fibers.
Views
Ethernet interface view
Predefined user roles
network-admin
Usage guidelines
This command forcibly brings up a fiber Ethernet port and enables the port to forward packets unidirectionally over a single link. In this way, transmission links are well utilized.
The shutdown, port up-mode, and loopback commands are mutually exclusive.
Examples
# Forcibly bring up fiber port Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] port up-mode
storm-constrain
Use storm-constrain to enable storm control and set thresholds for broadcast, multicast, or unknown unicast packets on an Ethernet interface.
Use undo storm-constrain to disable storm control for broadcast, multicast, unknown unicast, or all types of traffic.
Syntax
storm-constrain { broadcast | multicast | unicast } { pps | kbps | ratio } upperlimit lowerlimit
undo storm-constrain { all | broadcast | multicast | unicast }
Default
Traffic storm control is disabled.
Views
Layer 2 Ethernet interface view
Predefined user roles
network-admin
Parameters
all: Disables storm control for all types of traffic: broadcast, multicast, and unknown unicast.
broadcast: Enables or disables broadcast storm control.
multicast: Enables or disables multicast storm control.
unicast: Enables or disables unknown unicast storm control.
pps: Sets storm control thresholds in pps.
kbps: Sets storm control thresholds in kbps.
ratio: Sets storm control thresholds as a percentage of the transmission capacity of the interface.
upperlimit: Sets the upper threshold, in pps, kbps, or percentage.
· If you specify the pps keyword, the value range for the upperlimit argument is 1 to 1.4881 × the interface bandwidth.
· If you specify the kbps keyword, the value range for the upperlimit argument is 1 to the interface bandwidth.
· If you specify the ratio keyword, the value range for the upperlimit argument is 1 to 100.
lowerlimit: Sets the lower threshold, in pps, kbps, or percentage.
· If you specify the pps keyword, the value range for the lowerlimit argument is 1 to 1.4881 × the interface bandwidth.
· If you specify the kbps keyword, the value range for the lowerlimit argument is 1 to the interface bandwidth.
· If you specify the ratio keyword, the value range for the lowerlimit argument is 1 to 100.
Usage guidelines
After you configure storm control for a type of traffic, the device collects the statistics for the type of traffic at the interval configured by using the storm-constrain interval command. When the type of traffic exceeds its upper threshold, the interface takes an action configured by using the storm-constrain control command.
The storm-constrain, broadcast-suppression, multicast-suppression, and unicast-suppression commands can suppress storms on an interface. The broadcast-suppression, multicast-suppression, and unicast-suppression commands use the chip to physically suppress traffic. They have less influence on the device performance than the storm-constrain command, which uses software to suppress traffic.
For the traffic suppression result to be determined, do not configure both storm control and storm suppression for the same type of traffic.
When configuring this command, make sure upperlimit is greater than lowerlimit.
Examples
# Enable unknown unicast storm control on Ten-GigabitEthernet 1/0/1 and set the upper and lower thresholds to 200 pps and 150 pps, respectively.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] storm-constrain unicast pps 200 150
# Enable broadcast storm control on Ten-GigabitEthernet 1/0/2, and set the upper and lower thresholds to 2000 kbps and 1500 kbps, respectively.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/2
[Sysname-Ten-GigabitEthernet1/0/2] storm-constrain broadcast kbps 2000 1500
# Enable multicast storm control on Ten-GigabitEthernet 1/0/3, and set the upper and lower thresholds to 80% and 15%, respectively.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/3
[Sysname-Ten-GigabitEthernet1/0/3] storm-constrain multicast ratio 80 15
Related commands
storm-constrain control
storm-constrain interval
storm-constrain control
Use storm-constrain control to set the action to take on an Ethernet interface when a type of traffic (unknown unicast, multicast, or broadcast) exceeds the upper storm control threshold.
Use undo storm-constrain control to restore the default.
Syntax
storm-constrain control { block | shutdown }
undo storm-constrain control
Default
No action is taken on an Ethernet interface when a type of traffic exceeds the upper storm control threshold.
Views
Layer 2 Ethernet interface view
Predefined user roles
network-admin
Parameters
block: Blocks this type of traffic and forwards other types of traffic. Even though the interface does not forward the blocked traffic, it still counts the traffic. When the blocked traffic drops below the lower threshold, the port begins to forward the traffic.
shutdown: Goes down automatically. The interface goes down automatically and stops forwarding any traffic. When the blocked traffic drops below the lower threshold, the interface does not forward the traffic. To bring up the interface, use the undo shutdown command or disable storm control on the interface.
Examples
# Configure Ten-GigabitEthernet 1/0/1 to block a specific type of traffic when the type of traffic exceeds the upper storm control threshold.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] storm-constrain control block
Related commands
storm-constrain
storm-constrain control
storm-constrain enable log
Use storm-constrain enable log to enable an Ethernet interface to output log messages when it detects storm control threshold events.
Use undo storm-constrain enable log to disable an Ethernet interface from outputting log messages for storm control threshold events.
Syntax
storm-constrain enable log
undo storm-constrain enable log
Default
An Ethernet interface outputs log messages when monitored traffic exceeds the upper threshold or drops below the lower threshold from a value above the upper threshold.
Views
Layer 2 Ethernet interface view
Predefined user roles
network-admin
Examples
# Enable Ten-GigabitEthernet 1/0/1 to output log messages when it detects storm control threshold events.
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] storm-constrain enable log
storm-constrain enable trap
Use storm-constrain enable trap to enable an Ethernet interface to send storm control threshold event traps.
Use undo storm-constrain enable trap to disable an Ethernet interface from sending storm control threshold event traps.
Syntax
storm-constrain enable trap
undo storm-constrain enable trap
Default
An interface sends out storm control threshold event traps when monitored traffic exceeds the upper threshold or drops below the lower threshold from a value above the upper threshold.
Views
Layer 2 Ethernet interface view
Predefined user roles
network-admin
Examples
# Enable Ten-GigabitEthernet 1/0/1 to send traps when it detects storm control threshold events.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] storm-constrain enable trap
storm-constrain interval
Use storm-constrain interval to set the traffic polling interval of the storm control module.
Use undo storm-constrain interval to restore the default.
Syntax
storm-constrain interval interval
undo storm-constrain interval
Default
The storm control module polls traffic statistics every 10 seconds.
Views
System view
Predefined user roles
network-admin
Parameters
interval: Sets the traffic polling interval of the storm control module. The value range is 1 to 300 seconds. To ensure network stability, as a best practice, do not use a traffic polling interval shorter than 10 seconds.
Usage guidelines
The traffic polling interval set by using the storm-constrain interval command is specific to storm control. To set the statistics polling interval of an interface, use the flow-interval command.
Examples
# Set the traffic statistics polling interval of the storm control module to 60 seconds.
<Sysname> system-view
[Sysname] storm-constrain interval 60
Related commands
storm-constrain
storm-constrain control
Layer 3 Ethernet interface or subinterface commands
mac-address
Use mac-address to set the MAC address of an Ethernet interface.
Use undo mac-address to restore the default.
Syntax
mac-address mac-address
undo mac-address
Default
No MAC address is set for an Ethernet interface.
Views
Ethernet interface view
Predefined user roles
network-admin
Parameters
mac-address: Specifies a MAC address in the format of H-H-H.
Usage guidelines
Do not set a VRRP-reserved MAC address for a Layer 3 Ethernet subinterface.
Examples
# Set the MAC address of Ten-GigabitEthernet 1/0/1 to 0001-0001-0001.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] mac-address 1-1-1
mtu
Use mtu to set the MTU for an Ethernet interface or subinterface.
Use undo mtu to restore the default.
Syntax
mtu size [ spread ]
undo mtu [ spread ]
Default
The MTU of an Ethernet interface or subinterface is 1500 bytes.
Views
Layer 3 Ethernet interface view
Layer 3 Ethernet subinterface view
Predefined user roles
network-admin
Parameters
size: Sets the MTU in the range of 46 to 9008 bytes.
spread: Batch modifies the MTU for the subinterfaces of a main interface. Subinterfaces do not support this keyword.
Usage guidelines
The MTU setting for an interface takes effect only on packets sent by the CPU. Set a proper MTU to try to avoid packet fragmentation. If an interface has both the mtu and ip mtu commands executed, the ip mtu command rather than the mtu command takes effect on IPv4 packets sent by the interface. For more information about the ip mtu command, see IP performance optimization commands in Layer 3—IP Services Command Reference.
The mtu size command executed in main interface view takes effect only on the main interface. The mtu size command executed in subinterface view takes effect only on the subinterface.
The mtu size spread command executed in main interface view can modify the MTU for both the main interface and its subinterfaces. However, the MTU separately configured for a subinterface takes priority.
Examples
# Set the MTU to 1430 bytes for Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] mtu 1430
# Set the MTU to 1430 bytes for Ten-GigabitEthernet 1/0/1.1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1.1
[Sysname-Ten-GigabitEthernet1/0/1.1] mtu 1430
# Set the MTU to 1430 bytes for Ten-GigabitEthernet 1/0/1 and its subinterfaces.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] mtu 1430 spread
This operation may take a long time to modify the MTU of subinterfaces on this interface. Continue? [Y/N]:y
traffic-statistic enable
Use traffic-statistic enable to enable packet statistics collection for a Layer 3 Ethernet subinterface.
Use undo traffic-statistic enable to disable packet statistics collection for a Layer 3 Ethernet subinterface.
Syntax
traffic-statistic enable
undo traffic-statistic enable
Default
Packet statistics collection is disabled for a Layer 3 Ethernet subinterface.
Views
Layer 3 Ethernet subinterface view
Predefined user roles
network-admin
Usage guidelines
You can use the display interface or display counters command to display the subinterface traffic statistics. The Input and Output fields in the display interface command output display the Ethernet subinterface packet statistics.
Examples
# Enable packet statistics collection for Ten-GigabitEthernet1/0/1.1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1.1
[Sysname-Ten-GigabitEthernet1/0/1.1] traffic-statistic enable
Related commands
display counters
display interface