Ethernet interface commands

Common Ethernet interface commands

broadcast-suppression

Use broadcast-suppression to enable broadcast suppression and set the broadcast suppression threshold.

Use undo broadcast-suppression to disable broadcast suppression.

Syntax

broadcast-suppression pps max-pps

undo broadcast-suppression

Default

Ethernet interfaces do not suppress broadcast traffic.

Views

Layer 2 Ethernet interface view

Predefined user roles

network-admin

Parameters

pps max-pps: Specifies the maximum number of broadcast packets that the interface can forward per second. The value range for the max-pps argument (in pps) is 0 to 1.4881 × the interface bandwidth.

Usage guidelines

The broadcast storm suppression features limits the size of broadcast traffic to a threshold on an interface. When the broadcast traffic on the interface exceeds this threshold, the system drops packets until the traffic drops below this threshold.

The configured suppression threshold value in pps might be converted into a multiple of a step supported by the chip. As a result, the effective suppression threshold might be different from the configured one. To determine the suppression threshold that takes effect, see the prompts on the device.

Examples

# Set the broadcast suppression threshold to 12000 pps on GigabitEthernet 0/0/1.

<Sysname> system-view

[Sysname] interface gigabitethernet 0/0/1

[Sysname-GigabitEthernet0/0/1] broadcast-suppression pps 12000

Related commands

multicast-suppression

unicast-suppression

display ethernet statistics

Use display ethernet statistics to display the Ethernet module statistics.

Syntax

display ethernet statistics slot slot-number

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

slot slot-number: Specifies a card by its slot number.

Examples

# Display the Ethernet module statistics for the specified slot.

<Sysname> display ethernet statistics slot 0

ETH receive packet statistics:

    Totalnum        : 10447          ETHIINum     : 4459

    SNAPNum         : 0              RAWNum       : 0

    LLCNum          : 0              UnknownNum   : 0

    ForwardNum      : 4459           ARP          : 0

    MPLS            : 0              ISIS         : 0

    ISIS2           : 0              IP           : 0

    IPV6            : 0

ETH receive error statistics:

    NullPoint       : 0              ErrIfindex   : 0

    ErrIfcb         : 0              IfShut       : 0

    ErrAnalyse      : 5988           ErrSrcMAC    : 5988

    ErrHdrLen       : 0

 

ETH send packet statistics:

    L3OutNum        : 211            VLANOutNum   : 0

    FastOutNum      : 155            L2OutNum     : 0

ETH send error statistics:

    MbufRelayNum    : 0              NullMbuf     : 0

    ErrAdjFwd       : 0              ErrPrepend   : 0

    ErrHdrLen       : 0              ErrPad       : 0

    ErrQoSTrs       : 0              ErrVLANTrs   : 0

    ErrEncap        : 0              ErrTagVLAN   : 0

    IfShut          : 0              IfErr        : 0

Table 1 Output description

Field

Description

ETH receive packet statistics

Statistics about the Ethernet packets received by the Ethernet module:

·     Totalnum—Total number of received packets.

·     ETHIINum—Number of packets encapsulated by using Ethernet II.

·     SNAPNum—Number of packets encapsulated by using SNAP.

·     RAWNum—Number of packets encapsulated by using RAW.

·     ISISNum—Number of packets encapsulated by using ISIS.

·     LLCNum—Number of packets encapsulated by using LLC.

·     UnknownNum—Number of packets encapsulated by using unknown methods.

·     ForwardNum—Number of packets forwarded at Layer 2 or sent to the CPU.

·     ARP—Number of ARP packets. ‌

·     MPLS—Number of MPLS packets.

·     ISIS—Number of IS-IS packets.

·     ISIS2—Number of large 802.3/802.2 frames encapsulated by using IS-IS.

·     IP—Number of IP packets.

·     IPv6—Number of IPv6 packets.

ETH receive error statistics

Statistics about the error Ethernet packets in the inbound direction on the Ethernet module. Errors might be included in packets or occur during the receiving process. The items include:

·     NullPoint—Number of packets that include null pointers.

·     ErrIfindex—Number of packets that include incorrect interface indexes.

·     ErrIfcb—Number of packets that include incorrect interface control blocks.

·     IfShut—Number of packets that are being received when the interface is shut down.

·     ErrAnalyse—Number of packets that include packet parsing errors.

·     ErrSrcMAC—Number of packets that include incorrect source MAC addresses.

·     ErrHdrLen—Number of packets that include header length errors.

ETH send packet statistics

Statistics about the Ethernet packets sent by the Ethernet module:

·     L3OutNum—Number of packets sent out of Layer 3 Ethernet interfaces.

·     VLANOutNum—Number of packets sent out of VLAN interfaces.

·     FastOutNum—Number of packets fast forwarded.

·     L2OutNum—Number of packets sent out of Layer 2 Ethernet interfaces.

ETH send error statistics

Statistics about the error Ethernet packets in the outbound direction on the Ethernet module:

·     MbufRelayNum—Number of packets transparently sent.

·     NullMbuf—Number of packets with null pointers.

·     ErrAdjFwd—Number of packets with adjacency table errors.

·     ErrPrepend—Number of packets with extension errors.

·     ErrHdrLen—Number of packets with header length errors.

·     ErrPad—Number of packets with padding errors.

·     ErrQoSTrs—Number of packets that failed to be sent by QoS.

·     ErrVLANTrs—Number of packets that failed to be sent in VLANs.

·     ErrEncap—Number of packets that failed to be sent due to link header encapsulation failures.

·     ErrTagVLAN—Number of packets that failed to be sent due to VLAN tag encapsulation failures.

·     IfShut—Number of packets that are being sent when the interface is shut down.

·     IfErr—Number of packets with incorrect outgoing interfaces.

Related commands

reset ethernet statistics

display interface

Use display interface to display interface information.

Syntax

display interface [ interface-type [ interface-number | interface-number.subnumber ] ] [ brief [ description | down ] ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

interface-type: Specifies an interface type.

interface-number: Specifies an interface number.

interface-number.subnumber: Specifies a subinterface number. The interface-number argument is an interface number. The subnumber argument is the number of a subinterface created under the interface. The value range for the subnumber argument is 1 to 4094.

brief: Displays brief interface information. If you do not specify this keyword, the command displays detailed interface information.

description: Displays complete interface descriptions. If you do not specify this keyword, the command displays only the first 27 characters of each interface description.

down: Displays information about interfaces in down state and the causes. If you do not specify this keyword, the command displays information about interfaces in all states.

Usage guidelines

If you do not specify an interface type, this command displays information about all interfaces.

If you specify an interface type but do not specify an interface number, this command displays information about all interfaces of the specified type.

Examples

# Display information about Layer 3 interface GigabitEthernet 0/0/1.

<Sysname> display interface gigabitethernet 0/0/1

GigabitEthernet0/0/1

Current state: Administratively DOWN

Line protocol state: DOWN

Description: GigabitEthernet0/0/1 Interface

Bandwidth: 1000000 kbps

Maximum transmission unit: 1500

Allow jumbo frames to pass

Broadcast max-ratio: 100%

Unknown-multicast max-ratio: 100%

Unicast max-ratio: 100%

Internet protocol processing: Disabled

IP packet frame type: Ethernet II, hardware address: 3822-d666-bd0c

IPv6 packet frame type: Ethernet II, hardware address: 3822-d666-bd0c

Media type is twisted pair, port hardware type is 1000_BASE_T

Port priority: 2

Unknown-speed mode, unknown-duplex mode

Link speed type is autonegotiation, link duplex type is autonegotiation

Flow-control is not enabled

Maximum frame length: 9216

Output queue - Urgent queuing: Size/Length/Discards 0/1024/0

Output queue - Protocol queuing: Size/Length/Discards 0/500/0

Output queue - FIFO queuing: Size/Length/Discards 0/75/0

Last link flapping: 6 hours 39 minutes 28 seconds

Last clearing of counters: Never

Current system time:2019-01-08 14:50:06

Last time when physical state changed to up:2019-01-08 14:49:45

Last time when physical state changed to down:2019-01-08 14:49:45

 Peak input rate: 0 bytes/sec, at 2013-07-07 16:07:11

 Peak output rate: 0 bytes/sec, at 2013-07-07 16:07:11

 Last 300 seconds input:  0 packets/sec 0 bytes/sec  0%

 Last 300 seconds output: 0 packets/sec 0 bytes/sec  0%

 Input  (total): 0 packets, 0 bytes

          0 unicasts, 0 broadcasts, 0 multicasts, - pauses

 Input  (normal): 0 packets, 0 bytes

          0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses

 Input: 0 input errors, 0 runts, 0 giants, 0 throttles

          0 CRC, 0 frame, 0 overruns, - aborts

          - ignored, - parity errors

 Output  (total): 0 packets, 0 bytes

          0 unicasts, 0 broadcasts, 0 multicasts, - pauses

 Output  (normal): 0 packets, 0 bytes

          0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses

 Output: 0 output errors, - underruns, - buffer failures

          0 aborts, 0 deferred, 0 collisions, 0 late collisions

          - lost carrier, - no carrier

# Display detailed information about Layer 2 interface GigabitEthernet 0/0/1.

<Sysname> display interface gigabitethernet 0/0/1

GigabitEthernet0/0/1

Current state: DOWN

Line protocol state: DOWN

IP packet frame type: Ethernet II, hardware address: 000c-2963-b767

Description: GigabitEthernet0/0/1 Interface

Bandwidth: 100000 kbps

Loopback is not set

Media type is twisted pair, port hardware type is 1000_BASE_T_AN_SFP

Unknown-speed mode, unknown-duplex mode

Link speed type is autonegotiation, link duplex type is autonegotiation

Flow-control is not enabled

Maximum frame length: 9216

Allow jumbo frame to pass

Broadcast max-ratio: 100%

Unknown-multicast max-ratio: 100%

Unicast max-ratio: 100%

PVID: 1

MDI type: Automdix

Port link-type: Access

 Tagged VLANs:   None

 UnTagged VLANs: 1

Port priority: 2

Last link flapping: 6 hours 39 minutes 25 seconds

Last clearing of counters:  14:34:09 Tue 11/01/2011

Current system time:2019-01-08 14:50:06

Last time when physical state changed to up:2019-01-08 14:49:45

Last time when physical state changed to down:2019-01-08 14:49:45

 Peak input rate: 0 bytes/sec, at 2013-07-17 22:06:19

 Peak output rate: 0 bytes/sec, at 2013-07-17 22:06:19

 Last 300 seconds input:  0 packets/sec 0 bytes/sec -%

 Last 300 seconds output:  0 packets/sec 0 bytes/sec -%

 Input (total):  0 packets, 0 bytes

          0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses

 Input (normal):  0 packets, 0 bytes

          0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses

 Input:  0 input errors, 0 runts, 0 giants, 0 throttles

          0 CRC, 0 frame, 0 overruns, 0 aborts

          0 ignored, 0 parity errors

 Output (total): 0 packets, 0 bytes

          0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses

 Output (normal): 0 packets, 0 bytes

          0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses

 Output: 0 output errors, 0 underruns, 0 buffer failures

          0 aborts, 0 deferred, 0 collisions, 0 late collisions

          0 lost carrier, 0 no carrier

Table 2 Command output

Field

Description

Current state

Physical link state of the interface:

·     Administratively DOWN—The interface has been shut down by using the shutdown command.

·     DOWN—The interface is administratively up, but its physical state is down (possibly because no physical link exists or the link has failed).

·     DOWN ( Link-Aggregation interface down )—The aggregate interface to which the interface belongs has been shut down by using the shutdown command.

·     DOWN ( Tunnel-Bundle administratively down )—The tunnel bundle interface to which the interface belongs has been shut down by using the shutdown command.

·     Link-Flap DOWN—The interface has been shut down by the link flapping protection feature.

·     OFP DOWN—The interface has been shut down by OpenFlow.

·     STP DOWN—The interface has been shut down by the BPDU guard feature.

·     DOWN (No MEC license)—The interface has been shut down because the device does not have an MEC license.

·     UP—The interface is both administratively and physically up.

Line protocol state

Data link layer state of the interface. The state is determined through automatic parameter negotiation at the data link layer.

·     UP—The data link layer protocol is up.

·     UP (spoofing)—The data link layer protocol is up, but the link is an on-demand link or does not exist. This attribute is typical of null interfaces and loopback interfaces.

·     DOWN—The data link layer protocol is down.

·     DOWN (protocols)—The data link layer has been shut down by protocols included in the parentheses. Available protocols include:

¡     DLDP—Shuts down the data link layer when it detects that the link is unidirectional.

¡     LAGG—Shuts down the data link layer when it detects that the aggregate interface does not have Selected ports.

¡     BFD—Shuts down the data link layer when it detects a link failure.

Bandwidth

Expected bandwidth of the interface.

Maximum transmission unit

MTU of the interface.

Internet protocol processing

IP packet processing capability of the interface when the interface is not assigned an IP address:

·     Disabled—The interface cannot process IP packets.

·     Enabled—The interface can process IP packets.

Internet address: ip-address/mask-length (Type)

IP address of the interface and type of the address in parentheses.

Possible IP address types include:

·     Primary—Manually configured primary IP address.

·     Sub—Manually configured secondary IP address. If the interface has both primary and secondary IP addresses, the primary IP address is displayed. If the interface has only secondary IP addresses, the lowest secondary IP address is displayed.

·     DHCP-allocated—DHCP allocated IP address. For more information, see DHCP client configuration in Layer 3IP Services Configuration Guide.

·     BOOTP-allocatedBOOTP allocated IP address. For more information, see BOOTP client configuration in Layer 3IP Services Configuration Guide.

·     PPP-negotiated—IP address assigned by a PPP server during PPP negotiation. For more information, see PPP configuration in Layer 2WAN Access Configuration Guide.

·     Unnumbered—IP address borrowed from another interface.

·     MTunnel—IP address of the multicast tunnel interface (MTI), which is the same as the IP address of the MVPN source interface. For more information, see multicast VPN configuration in Multicast Configuration Guide.

IP packet frame type

IPv4 packet framing format.

hardware address

MAC address of the interface.

IPv6 packet frame type

IPv6 packet framing format.

Port priority

Port priority of the interface.

Loopback is set internal

An internal loopback test is running on the interface. This field depends on your configuration.

Loopback is set external

An external loopback test is running on the interface. This field depends on your configuration.

Loopback is not set

No loopback test is running on the interface. This field depends on your configuration.

10Mbps-speed mode

The interface is operating at 10 Mbps. This field depends on your configuration and the link parameter negotiation result.

100Mbps-speed mode

The interface is operating at 100 Mbps. This field depends on your configuration and the link parameter negotiation result.

1000Mbps-speed mode

The interface is operating at 1000 Mbps. This field depends on your configuration and the link parameter negotiation result.

10Gbps-speed mode

The interface is operating at 10 Gbps. This field depends on your configuration and the link parameter negotiation result.

Unknown-speed mode

The speed of the interface is unknown because the speed negotiation fails or the interface is physically disconnected.

full-duplex mode

The interface is operating in full duplex mode. This field depends on your configuration and the link parameter negotiation result.

unknown-duplex mode

The duplex mode of the interface is unknown because the duplex mode negotiation fails or the interface is physically disconnected.

Link speed type is autonegotiation

The interface is configured with the speed auto command.

Link speed type is force link

The interface is manually configured with a speed (for example, 1000 Mbps) by using the speed command.

link duplex type is autonegotiation

The interface is configured with the duplex auto command.

link duplex type is force link

The interface is manually configured with a duplex mode (for example, full) by using the duplex command.

Maximum frame length

Maximum length of Ethernet frames allowed to pass through the interface.

Allow jumbo frame to pass

The interface allows jumbo frames to pass through.

Broadcast max-

Broadcast storm suppression threshold in ratio, pps, or kbps. 

Multicast max-

Multicast storm suppression threshold in ratio, pps, or kbps.

Unicast max-

Unknown unicast storm suppression threshold in ratio, pps, or kbps.

PVID

Port VLAN ID (PVID) of the interface.

MDI type

MDIX mode of the interface:

·     automdix.

·     mdi.

·     mdix.

Port link-type

Link type of the interface:

·     access.

·     trunk.

·     hybrid.

Tagged VLANs

VLANs for which the interface sends packets without removing VLAN tags.

Untagged VLANs

VLANs for which the interface sends packets after removing VLAN tags.

VLAN Passing

VLANs whose packets can be forwarded by the port. The VLANs must have been created.

VLAN permitted

VLANs whose packets are permitted by the port.

Trunk port encapsulation

Encapsulation protocol type for the trunk port.

Last link flapping

The amount of time that has elapsed since the most recent physical state change of the interface. This field displays Never if the interface has been physically down since device startup.

Last clearing of counters

Time when the reset counters interface command was last used to clear the interface statistics. This field displays Never if the reset counters interface command has never been used on the interface since device startup.

Current system time

Current system date and time, which is displayed in the YYYY-MM-DD hh:mm:ss format by default.

If the time zone is configured, this field is in the YYYY-MM-DD hh:mm:ss zone-name±hh:mm:ss format, where the zone-name argument is the local time zone name.

Last time when physical state changed to up

Last date and time when the physical state of the interface changed to up, which is displayed in the YYYY-MM-DD hh:mm:ss format by default.

If the time zone is configured, this field is in the YYYY-MM-DD hh:mm:ss zone-name±hh:mm:ss format, where the zone-name argument is the local time zone name.

If the physical state of the interface has never changed to up, this field displays a hyphen (-).

Last time when physical state changed to down

Last date and time when the physical state of the interface changed to down, which is displayed in the YYYY-MM-DD hh:mm:ss format by default.

If the time zone is configured, this field is in the YYYY-MM-DD hh:mm:ss zone-name±hh:mm:ss format, where the zone-name argument is the local time zone name.

If the physical state of the interface has never changed to down, this field displays a hyphen (-).

Last 300 seconds input:  0 packets/sec 0 bytes/sec 0%

Last 300 seconds output:  0 packets/sec 0 bytes/sec 0%

Average inbound or outbound traffic rate (in pps and Bps) in the last 300 seconds, and the ratio of the actual rate to the interface bandwidth.

A hyphen (-) indicates that the statistical item is not supported.

Input(total):  0 packets, 0 bytes

          0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses

The two fields on the first line represent the inbound traffic statistics (in packets and bytes) for the interface. All inbound normal packets, abnormal packets, and normal pause frames were counted.

The four fields on the second line represent:

·     Number of inbound unicast packets.

·     Number of inbound broadcasts.

·     Number of inbound multicasts.

·     Number of inbound pause frames.

A hyphen (-) indicates that the statistical item is not supported.

Input(normal):  0 packets, 0 bytes

          0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses

The two fields on the first line represent the inbound normal traffic and pause frame statistics (in packets and bytes) for the interface.

The four fields on the second line represent:

·     Number of inbound normal unicast packets.

·     Number of inbound normal broadcasts.

·     Number of inbound normal multicasts.

·     Number of inbound normal pause frames.

A hyphen (-) indicates that the statistical item is not supported.

input errors

Statistics of incoming error packets.

runts

Number of inbound frames meeting the following conditions:

·     Shorter than 64 bytes.

·     In correct format.

·     Containing valid CRCs.

giants

Number of inbound giants. Giants refer to frames larger than the maximum frame length supported on the interface.

For an Ethernet interface that does not permit jumbo frames, the maximum frame length is as follows:

·     1518 bytes (without VLAN tags).

·     1522 bytes (with VLAN tags).

For an Ethernet interface that permits jumbo frames, the maximum Ethernet frame length is set when you configure jumbo frame support on the interface.

throttles

Number of inbound frames that had a non-integer number of bytes.

CRC

Total number of inbound frames that had a normal length, but contained CRC errors.

frame

Total number of inbound frames that contained CRC errors and a non-integer number of bytes.

overruns

Number of packets dropped because the input rate of the port exceeded the queuing capability.

aborts

Total number of illegal inbound packets:

·     Fragment frames—CRC error frames shorter than 64 bytes. The length (in bytes) can be an integral or non-integral value.

·     Jabber frames—CRC error frames greater than the maximum frame length supported on the Ethernet interface (with an integral or non-integral length).

¡     For an Ethernet interface that does not permit jumbo frames, the maximum frame length is 1518 bytes (without VLAN tags) or 1522 bytes (with VLAN tags).

¡     For an Ethernet interface that permits jumbo frames, the maximum Ethernet frame length is set when you configure jumbo frame support on the interface.

·     Symbol error frames—Frames that contained a minimum of one undefined symbol.

·     Unknown operation code frames—Non-pause MAC control frames.

·     Length error frames—Frames whose 802.3 length fields did not match the actual frame length (46 to 1500 bytes).

ignored

Number of inbound frames dropped because the receiving buffer of the port ran low.

parity errors

Total number of frames with parity errors.

Output(total): 0 packets, 0 bytes

          0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses

The two fields on the first line represent the outbound traffic statistics (in packets and bytes) for the interface. All outbound normal packets, abnormal packets, and normal pause frames were counted.

The four fields on the second line represent:

·     Number of outbound unicast packets.

·     Number of outbound broadcasts.

·     Number of outbound multicasts.

·     Number of outbound pause frames.

A hyphen (-) indicates that the statistical item is not supported.

Output(normal): 0 packets, 0 bytes

          0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses

The two fields on the first line represent the outbound normal traffic and pause frame statistics (in packets and bytes) for the interface.

The four fields on the second line represent:

·     Number of outbound normal unicast packets.

·     Number of outbound normal broadcasts.

·     Number of outbound normal multicasts.

·     Number of outbound normal pause frames.

A hyphen (-) indicates that the statistical item is not supported.

output errors

Number of outbound packets with errors.

underruns

Number of packets dropped because the output rate of the interface exceeded the output queuing capability. This is a low-probability hardware anomaly.

buffer failures

Number of packets dropped because the transmitting buffer of the interface ran low.

aborts

Number of packets that failed to be transmitted, for example, because of Ethernet collisions.

deferred

Number of frames that the interface deferred to transmit because of detected collisions.

collisions

Number of frames that the interface stopped transmitting because Ethernet collisions were detected during transmission.

late collisions

Number of frames that the interface deferred to transmit after transmitting their first 512 bits because of detected collisions.

Peak input rate

Peak rate of inbound traffic in Bps, and the time when the peak inbound traffic rate occurred.

Peak output rate

Peak rate of outbound traffic in Bps, and the time when the peak outbound traffic rate occurred.

# Display brief information about all interfaces.

<Sysname> display interface brief

Brief information on interfaces in route mode:

Link: ADM - administratively down; Stby - standby

Protocol: (s) – spoofing

 

Interface            Link Protocol Primary IP      Description

GE0/0/1              DOWN DOWN     --

Loop0                UP   UP(s)    2.2.2.9

NULL0                UP   UP(s)    --

Vlan1                UP   DOWN     --

Vlan999              UP   UP       192.168.1.42

 

Brief information on interfaces in bridge mode:

Link: ADM - administratively down; Stby - standby

Speed: (a) - auto

Duplex: (a)/A - auto; H - half; F - full

Type: A - access; T - trunk; H - hybrid

Interface            Link Speed   Duplex Type PVID Description

GE0/0/2              DOWN auto    A      A    1

GE0/0/3              UP   auto    F(a)   A    1    aaaaaaaaaaaaaaaaaaaaaaaaaaa

# Display brief information about GigabitEthernet 0/0/3, including the complete description of the interface.

<Sysname> display interface gigabitethernet 0/0/3 brief description

Brief information on interfaces in bridge mode:

Link: ADM - administratively down; Stby - standby

Speed: (a) - auto

Duplex: (a)/A - auto; H - half; F - full

Type: A - access; T - trunk; H - hybrid

Interface            Link Speed   Duplex Type PVID Description

GE0/0/3              UP   auto    F(a)   A    1    aaaaaaaaaaaaaaaaaaaaaaaaaaaaa

aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa

# Display information about interfaces in DOWN state and the causes.

<Sysname> display interface brief down

Brief information on interfaces in route mode:

Link: ADM - administratively down; Stby - standby

Interface            Link Cause

GE0/0/1              DOWN Not connected

Vlan2                DOWN Not connected

 

Brief information on interfaces in bridge mode:

Link: ADM - administratively down; Stby - standby

Interface            Link Cause

GE0/0/2              DOWN Not connected

Table 3 Command output

Field

Description

Brief information on interfaces in route mode:

Brief information about Layer 3 interfaces.

Interface

Interface name.

Link

Physical link state of the interface:

·     UP—The interface is physically up.

·     DOWN—The interface is physically down.

·     ADM—The interface has been shut down by using the shutdown command. To restore the physical state of the interface, use the undo shutdown command.

·     Stby—The interface is a backup interface in standby state. To see the primary interface, use the display interface-backup state command.

Protocol

Data link layer protocol state of the interface:

·     UP—The data link layer protocol of the interface is up.

·     DOWN—The data link layer protocol of the interface is down.

·     UP(s)—The data link layer protocol of the interface is up, but the link is an on-demand link or does not exist. The (s) attribute represents the spoofing flag. This value is typical of null interfaces and loopback interfaces.

Primary IP

Primary IP address of the interface. This field displays two hyphens (--) if the interface does not have an IP address.

Description

Description of the interface.

Brief information of interfaces in bridge mode:

Brief information about Layer 2 interfaces.

Type: A - access; T - trunk; H – hybrid

Link type options for interfaces.

Speed

Speed of the interface, in bps.

This field displays the (a) flag next to the speed if the speed is automatically negotiated.

This field displays auto if the interface is configured to autonegotiate its speed but the autonegotiation has not started.

Duplex

Duplex mode of the interface:

·     A—Autonegotiation. The interface is configured to autonegotiate its duplex mode but the autonegotiation has not started.

·     F—Full duplex.

·     F(a)—Autonegotiated full duplex.

Type

Link type of the interface:

·     A—Access.

·     H—Hybrid.

·     T—Trunk.

PVID

Port VLAN ID.

Cause

Cause for the physical link state of an interface to be DOWN:

·     Administratively—The interface has been manually shut down by using the shutdown command. To restore the physical state of the interface, use the undo shutdown command.

·     DOWN ( Link-Aggregation interface down )—The interface is a member port of an aggregate interface, and the aggregate interface is down.

·     DOWN (Loopback detection down)—The loopback detection module has detected loops.

·     Not connected—No physical connection exists (possibly because the network cable is disconnected or faulty).

·     STP DOWN—The interface has been shut down by the BPDU guard feature.

·     Port Security Disabled—The interface has been shut down by the intrusion detection mechanism because the interface received illegal packets.

·     OFP DOWN—The interface has been shut down by OpenFlow.

·     Standby—The interface is a backup interface in standby state.

Related commands

reset counters interface

display link-flap protection

Use display link-flap protection to display information about link flapping protection on an interface.

Syntax

display link-flap protection [ interface interface-type [ interface-number ] ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

interface-type: Specifies an interface type. If you do not specify an interface type, the command displays information about link flapping protection on all interfaces.

interface-number: Specifies an interface number. If you do not specify an interface number, the command displays information about link flapping protection on all interfaces of the specified type.

Examples

# Display information about link flapping protection on an interface.

<Sysname> display link-flap protection

Link-flap protection: Enabled

Interface            Link-flap  Status  Interval  Threshold

GE0/0/1              Enabled    Down    10        5

GE0/0/2              Disabled   N/A     --        --

Table 4 Command output

Field

Description

Link-flap protection

Status of link flapping protection on all interfaces:

·     Enabled—Link flapping protection is enabled on all interfaces.

·     Disabled—Link flapping protection is disabled on all interfaces.

Link-flap

Status of link flapping protection on an interface:

·     Enabled—Link flapping protection is enabled on an interface.

·     Disabled—Link flapping protection is disabled on an interface.

·     Unconfig—Link flapping protection is not configured on an interface.

Status

Status of an interface:

·     Down—The interface has been shut down by the link flapping protection feature.

·     N/A—The interface status is not affected by the link flapping protection feature.

Interval

Link flapping detection interval for an interface.

Threshold

Link flapping detection threshold for an interface.

Related commands

link-flap protect enable

port link-flap protect enable

duplex

Use duplex to set the duplex mode for an Ethernet interface.

Use undo duplex to restore the default.

Syntax

duplex { auto | full }

undo duplex

Default

Ethernet interfaces operate in autonegotiation mode.

Views

Ethernet interface view

Predefined user roles

network-admin

Parameters

auto: Configures the interface to autonegotiate the duplex mode with the peer.

full: Configures the interface to operate in full duplex mode. In this mode, the interface can receive and transmit packets simultaneously.

Examples

# Configure GigabitEthernet 0/0/1 to operate in full duplex mode.

<Sysname> system-view

[Sysname] interface gigabitethernet 0/0/1

[Sysname-GigabitEthernet0/0/1] duplex full

flow-control

Use flow-control to enable TxRx-mode generic flow control on an Ethernet interface.

Use undo flow-control to disable TxRx-mode generic flow control on the Ethernet interface.

Syntax

flow-control

undo flow-control

Default

TxRx-mode generic flow control is disabled on an Ethernet interface.

Views

Ethernet interface view

Predefined user roles

network-admin

Usage guidelines

With TxRx-mode generic flow control configured, an interface can both send and receive flow control frames:

·     When congested, the interface sends a flow control frame to its peer.

·     Upon receiving a flow control frame from the peer, the interface suspends sending packets.

To implement flow control on a link, enable generic flow control at both ends of the link.

Examples

# Enable TxRx-mode generic flow control on GigabitEthernet 0/0/1.

<Sysname> system-view

[Sysname] interface gigabitethernet 0/0/1

[Sysname-GigabitEthernet0/0/1] flow-control

flow-interval

Use flow-interval to set the statistics polling interval.

Use undo flow-interval to restore the default.

Syntax

flow-interval interval

undo flow-interval

Default

The statistics polling interval is 300 seconds.

Views

System view

Predefined user roles

network-admin

Parameters

interval: Sets the statistics polling interval in seconds. The interval is in the range of 5 to 300 and must be a multiple of 5.

Examples

# Set the statistics polling interval to 100 seconds.

<Sysname> system-view

[Sysname] flow-interval 100

ifmonitor crc-error

Use ifmonitor crc-error to configure global CRC error packet alarm parameters.

Use undo ifmonitor crc-error to restore the default.

Syntax

ifmonitor crc-error slot slot-number high-threshold high-value low-threshold low-value interval interval [ shutdown ]

undo ifmonitor crc-error slot slot-number

Default

The upper threshold is 1000, the lower threshold is 100, and the statistics collection and comparison interval is 10 seconds for CRC error packet alarms.

Views

System view

Predefined user roles

network-admin

Parameters

high-threshold high-value: Specifies the upper threshold for CRC error packet alarms, in the range of 1 to 4294967295 packets.

low-threshold low-value: Specifies the lower threshold for CRC error packet alarms, in the range of 1 to 4294967295 packets.

interval interval: Specifies the statistics collection and comparison interval for CRC error packets, in the range of 1 to 65535 seconds.

shutdown: Shuts down an interface when the number of incoming CRC error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of incoming CRC error packets exceeds the upper threshold on the interface.

slot slot-number: Specifies a card by its slot number.

Usage guidelines

With the CRC error packet alarm function enabled, when the number of incoming CRC error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of incoming CRC error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.

You can configure the CRC error packet alarm parameters in system view and interface view.

·     The configuration in system view takes effect on all interfaces. The configuration in interface view takes effect only on the current interface.

·     For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.

When you execute this command multiple times, the most recent configuration takes effect.

Examples

# Set the upper threshold to 5000, lower threshold to 400, and statistics collection and comparison interval to 6 seconds for CRC error packet alarms.

<Sysname> system-view

[Sysname] ifmonitor crc-error slot 0 high-threshold 5000 low-threshold 400 interval 6

Related commands

snmp-agent trap enable ifmonitor

ifmonitor input-error

Use ifmonitor input-error to configure global input error packet alarm parameters.

Use undo ifmonitor input-error to restore the default.

Syntax

ifmonitor input-error slot slot-number high-threshold high-value low-threshold low-value interval interval [ shutdown ]

undo ifmonitor input-error slot slot-number

Default

The upper threshold is 1000, the lower threshold is 100, and the statistics collection and comparison interval is 10 seconds for input error packet alarms.

Views

System view

Predefined user roles

network-admin

Parameters

high-threshold high-value: Specifies the upper threshold for input error packet alarms, in the range of 1 to 4294967295 packets.

low-threshold low-value: Specifies the lower threshold for input error packet alarms, in the range of 1 to 4294967295 packets.

interval interval: Specifies the statistics collection and comparison interval for input error packets, in the range of 1 to 65535 seconds.

shutdown: Shuts down an interface when the number of input error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of input error packets exceeds the upper threshold on the interface.

slot slot-number: Specifies a card by its slot number.

Usage guidelines

With the input error packet alarm function enabled, when the number of input error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of input error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.

You can configure the input error packet alarm parameters in system view and interface view.

·     The configuration in system view takes effect on all interfaces. The configuration in interface view takes effect only on the current interface.

·     For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.

When you execute this command multiple times, the most recent configuration takes effect.

Examples

# Set the upper threshold to 5000, lower threshold to 400, and statistics collection and comparison interval to 6 seconds for input error packet alarms.

<Sysname> system-view

[Sysname] ifmonitor input-error slot 0 high-threshold 5000 low-threshold 400 interval 6

Related commands

snmp-agent trap enable ifmonitor

ifmonitor input-usage

Use ifmonitor input-usage to configure global input bandwidth usage alarm parameters.

Use undo ifmonitor input-usage to restore the default.

Syntax

ifmonitor input-usage slot slot-number high-threshold high-value low-threshold low-value

undo ifmonitor input-usage slot slot-number

Default

The upper threshold is 90, and the lower threshold is 80.

Views

System view

Predefined user roles

network-admin

Parameters

high-threshold high-value: Specifies the upper threshold for input bandwidth usage alarms, in the range of 1 to 100.

low-threshold low-value: Specifies the lower threshold for input bandwidth usage alarms, in the range of 1 to 100.

slot slot-number: Specifies a card by its slot number.

Usage guidelines

With the input bandwidth usage alarm function enabled, when the input bandwidth usage on an interface in normal state within the most recent statistics polling interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the input bandwidth usage on an interface in the alarm state within the most recent statistics polling interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.

You can use the flow-interval command to set the statistics polling interval.

The configuration in system view takes effect on all interfaces.

For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the input bandwidth usage alarm function.

When you execute this command multiple times, the most recent configuration takes effect.

Examples

# Set the upper threshold to 95 and lower threshold to 80 for input bandwidth usage alarms.

<Sysname> system-view

[Sysname] ifmonitor input-usage slot 0 high-threshold 95 low-threshold 80

Related commands

flow-interval

snmp-agent trap enable ifmonitor

ifmonitor output-error

Use ifmonitor output-error to configure global output error packet alarm parameters.

Use undo ifmonitor output-error to restore the default.

Syntax

ifmonitor output-error slot slot-number high-threshold high-value low-threshold low-value interval interval [ shutdown ]

undo ifmonitor output-error slot slot-number

Default

The upper threshold is 1000, the lower threshold is 100, and the statistics collection and comparison interval is 10 seconds for output error packet alarms.

Views

System view

Predefined user roles

network-admin

Parameters

high-threshold high-value: Specifies the upper threshold for output error packet alarms, in the range of 1 to 4294967295 packets.

low-threshold low-value: Specifies the lower threshold for output error packet alarms, in the range of 1 to 4294967295 packets.

interval interval: Specifies the statistics collection and comparison interval for output error packets, in the range of 1 to 65535 seconds.

shutdown: Shuts down an interface when the number of output error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of output error packets exceeds the upper threshold on the interface.

slot slot-number: Specifies a card by its slot number.

Usage guidelines

With the output error packet alarm function enabled, when the number of output error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of output error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.

You can configure the output error packet alarm parameters in system view and interface view.

·     The configuration in system view takes effect on all interfaces. The configuration in interface view takes effect only on the current interface.

·     For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.

When you execute this command multiple times, the most recent configuration takes effect.

Examples

# Set the upper threshold to 5000, lower threshold to 400, and statistics collection and comparison interval to 6 seconds for output error packet alarms.

<Sysname> system-view

[Sysname] ifmonitor output-error slot 0 high-threshold 5000 low-threshold 400 interval 6

Related commands

snmp-agent trap enable ifmonitor

ifmonitor output-usage

Use ifmonitor output-usage to configure global output bandwidth usage alarm parameters.

Use undo ifmonitor output-usage to restore the default.

Syntax

ifmonitor output-usage slot slot-number high-threshold high-value low-threshold low-value

undo ifmonitor output-usage slot slot-number

Default

The upper threshold is 90, and the lower threshold is 80.

Views

System view

Predefined user roles

network-admin

Parameters

high-threshold high-value: Specifies the upper threshold for output bandwidth usage alarms, in the range of 1 to 100.

low-threshold low-value: Specifies the lower threshold for output bandwidth usage alarms, in the range of 1 to 100.

slot slot-number: Specifies a card by its slot number.

Usage guidelines

With the output bandwidth usage alarm function enabled, when the output bandwidth usage on an interface in normal state within the most recent statistics polling interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the output bandwidth usage on an interface in the alarm state within the most recent statistics polling interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.

You can use the flow-interval command to set the statistics polling interval.

The configuration in system view takes effect on all interfaces.

For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the output bandwidth usage alarm function.

When you execute this command multiple times, the most recent configuration takes effect.

Examples

# Set the upper threshold to 80 and lower threshold to 60 for output bandwidth usage alarms.

<Sysname> system-view

[Sysname] ifmonitor output-usage slot 0 high-threshold 80 low-threshold 60

Related commands

flow-interval

snmp-agent trap enable ifmonitor

ifmonitor rx-pause

Use ifmonitor rx-pause to configure global received pause frame alarm parameters.

Use undo ifmonitor rx-pause to restore the default.

Syntax

ifmonitor rx-pause  slot slot-number high-threshold high-value low-threshold low-value interval interval

undo ifmonitor rx-pause slot slot-number

Default

The upper threshold is 500, the lower threshold is 100, and the statistics collection and comparison interval is 10 seconds for received pause frame alarms.

Views

System view

Predefined user roles

network-admin

Parameters

high-threshold high-value: Specifies the upper threshold for received pause frame alarms, in the range of 1 to 4294967295 packets.

low-threshold low-value: Specifies the lower threshold for received pause frame alarms, in the range of 1 to 4294967295 packets.

interval interval: Specifies the statistics collection and comparison interval for received pause frames, in the range of 1 to 65535 seconds.

slot slot-number: Specifies a card by its slot number.

Usage guidelines

With the received pause frame alarm function enabled, when the number of received pause frames on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of received pause frames on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.

You can configure the received pause frame alarm parameters in system view and interface view.

·     The configuration in system view takes effect on all interfaces. The configuration in interface view takes effect only on the current interface.

·     For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.

For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the received pause frame alarm function.

When you execute this command multiple times, the most recent configuration takes effect.

Examples

# Set the upper threshold to 30, lower threshold to 20, and statistics collection and comparison interval to 4 seconds for received pause frame alarms.

<Sysname> system-view

[Sysname] ifmonitor rx-pause slot 0 high-threshold 30 low-threshold 20 interval 4

Related commands

snmp-agent trap enable ifmonitor

ifmonitor sdh-b1-error

Use ifmonitor sdh-b1-error to configure global SDH-B1 error packet alarm parameters.

Use undo ifmonitor sdh-b1-error to restore the default.

Syntax

ifmonitor sdh-b1-error slot slot-number high-threshold high-value low-threshold low-value interval interval [ shutdown ]

undo ifmonitor sdh-b1-error slot slot-number

Default

The upper threshold is 1000, the lower threshold is 100, and the statistics collection and comparison interval is 10 seconds for SDH-B1 error packet alarms.

Views

System view

Predefined user roles

network-admin

Parameters

high-threshold high-value: Specifies the upper threshold for SDH-B1 error packet alarms, in the range of 1 to 4294967295 packets.

low-threshold low-value: Specifies the lower threshold for SDH-B1 error packet alarms, in the range of 1 to 4294967295 packets.

interval interval: Specifies the statistics collection and comparison interval for SDH-B1 error packets, in the range of 1 to 65535 seconds.

shutdown: Shuts down an interface when the number of incoming SDH-B1 error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of incoming SDH-B1 error packets exceeds the upper threshold on the interface.

slot slot-number: Specifies a card by its slot number.

Usage guidelines

With the SDH-B1 error packet alarm function enabled, when the number of incoming SDH-B1 error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of incoming SDH-B1 error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.

You can configure the SDH-B1 error packet alarm parameters in system view and interface view.

·     The configuration in system view takes effect on all interfaces. The configuration in interface view takes effect only on the current interface.

·     For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.

For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the SDH-B1 error packet alarm function.

When you execute this command multiple times, the most recent configuration takes effect.

Examples

# Set the upper threshold to 65, lower threshold to 25, and statistics collection and comparison interval to 20 seconds for SDH-B1 error packet alarms.

<Sysname> system-view

[Sysname] ifmonitor sdh-b1-error slot 0 high-threshold 65 low-threshold 25 interval 20

Related commands

snmp-agent trap enable ifmonitor

ifmonitor sdh-b2-error

Use ifmonitor sdh-b2-error to configure global SDH-B2 error packet alarm parameters.

Use undo ifmonitor sdh-b2-error to restore the default.

Syntax

ifmonitor sdh-b2-error slot slot-number high-threshold high-value low-threshold low-value interval interval [ shutdown ]

undo ifmonitor sdh-b2-error slot slot-number

Default

The upper threshold is 1000, the lower threshold is 100, and the statistics collection and comparison interval is 10 seconds for SDH-B2 error packet alarms.

Views

System view

Predefined user roles

network-admin

Parameters

high-threshold high-value: Specifies the upper threshold for SDH-B2 error packet alarms, in the range of 1 to 4294967295 packets.

low-threshold low-value: Specifies the lower threshold for SDH-B2 error packet alarms, in the range of 1 to 4294967295 packets.

interval interval: Specifies the statistics collection and comparison interval for SDH-B2 error packets, in the range of 1 to 65535 seconds.

shutdown: Shuts down an interface when the number of incoming SDH-B2 error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of incoming SDH-B2 error packets exceeds the upper threshold on the interface.

slot slot-number: Specifies a card by its slot number.

Usage guidelines

With the SDH-B2 error packet alarm function enabled, when the number of incoming SDH-B2 error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of incoming SDH-B2 error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.

You can configure the SDH-B2 error packet alarm parameters in system view and interface view.

·     The configuration in system view takes effect on all interfaces. The configuration in interface view takes effect only on the current interface.

·     For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.

For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the SDH-B2 error packet alarm function.

When you execute this command multiple times, the most recent configuration takes effect.

Examples

# Set the upper threshold to 6, lower threshold to 5, and statistics collection and comparison interval to 2 seconds for SDH-B2 error packet alarms.

<Sysname> system-view

[Sysname] ifmonitor sdh-b2-error slot 0 high-threshold 6 low-threshold 5 interval 2

Related commands

snmp-agent trap enable ifmonitor

ifmonitor sdh-error

Use ifmonitor sdh-error to configure global SDH error packet alarm parameters.

Use undo ifmonitor sdh-error to restore the default.

Syntax

ifmonitor sdh-error slot slot-number high-threshold high-value low-threshold low-value interval interval [ shutdown ]

undo ifmonitor sdh-error slot slot-number

Default

The upper threshold is 1000, the lower threshold is 100, and the statistics collection and comparison interval is 10 seconds for SDH error packet alarms.

Views

System view

Predefined user roles

network-admin

Parameters

high-threshold high-value: Specifies the upper threshold for SDH error packet alarms, in the range of 1 to 4294967295 packets.

low-threshold low-value: Specifies the lower threshold for SDH error packet alarms, in the range of 1 to 4294967295 packets.

interval interval: Specifies the statistics collection and comparison interval for SDH error packets, in the range of 1 to 65535 seconds.

shutdown: Shuts down an interface when the number of incoming SDH error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of incoming SDH error packets exceeds the upper threshold on the interface.

slot slot-number: Specifies a card by its slot number.

Usage guidelines

With the SDH error packet alarm function enabled, when the number of incoming SDH error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of incoming SDH error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.

You can configure the SDH error packet alarm parameters in system view and interface view.

·     The configuration in system view takes effect on all interfaces. The configuration in interface view takes effect only on the current interface.

·     For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.

For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the SDH error packet alarm function.

When you execute this command multiple times, the most recent configuration takes effect.

Examples

# Set the upper threshold to 35, lower threshold to 20, and statistics collection and comparison interval to 8 seconds for SDH error packet alarms.

<Sysname> system-view

[Sysname] ifmonitor sdh-error slot 0 high-threshold 35 low-threshold 20 interval 8

Related commands

snmp-agent trap enable ifmonitor

ifmonitor tx-pause

Use ifmonitor tx-pause to configure global sent pause frame alarm parameters.

Use undo ifmonitor tx-pause to restore the default.

Syntax

ifmonitor tx-pause slot slot-number high-threshold high-value low-threshold low-value interval interval

undo ifmonitor tx-pause slot slot-number

Default

The upper threshold is 500, the lower threshold is 100, and the statistics collection and comparison interval is 10 seconds for sent pause frame alarms.

Views

System view

Predefined user roles

network-admin

Parameters

high-threshold high-value: Specifies the upper threshold for sent pause frame alarms, in the range of 1 to 4294967295 packets.

low-threshold low-value: Specifies the lower threshold for sent pause frame alarms, in the range of 1 to 4294967295 packets.

interval interval: Specifies the statistics collection and comparison interval for sent pause frames, in the range of 1 to 65535 seconds.

slot slot-number: Specifies a card by its slot number.

Usage guidelines

With the sent pause frame alarm function enabled, when the number of sent pause frames on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of sent pause frames on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.

You can configure the sent pause frame alarm parameters in system view and interface view.

·     The configuration in system view takes effect on all interfaces. The configuration in interface view takes effect only on the current interface.

·     For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.

For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the sent pause frame alarm function.

When you execute this command multiple times, the most recent configuration takes effect.

Examples

# Set the upper threshold to 20, lower threshold to 10, and statistics collection and comparison interval to 5 seconds for sent pause frame alarms.

<Sysname> system-view

[Sysname] ifmonitor tx-pause slot 0 high-threshold 20 low-threshold 10 interval 5

Related commands

snmp-agent trap enable ifmonitor

interface

Use interface to enter interface view, create a subinterface and enter its view, or enter the view of an existing subinterface.

Syntax

interface interface-type { interface-number | interface-number.subnumber }

Views

System view

Predefined user roles

network-admin

Parameters

interface-type: Specifies an interface type.

interface-number: Specifies an interface number.

interface-number.subnumber: Specifies a subinterface number. The interface-number argument is an interface number. The subnumber argument is the number of a subinterface created under the interface. The value range for the subnumber argument is 1 to 4094.

Examples

# Enter the view of GigabitEthernet 0/0/1.

<Sysname> system-view

[Sysname] interface gigabitethernet 0/0/1

[Sysname-GigabitEthernet0/0/1]

# Create Ethernet subinterface GigabitEthernet 0/0/1.1 and enter its view.

<Sysname> system-view

[Sysname] interface gigabitethernet 0/0/1.1

[Sysname-GigabitEthernet0/0/1.1]

jumboframe enable

Use jumboframe enable to allow jumbo frames within the specified length to pass through.

Use undo jumboframe enable to prevent jumbo frames from passing through.

Use undo jumboframe enable size to restore the default.

Syntax

jumboframe enable [ size ]

undo jumboframe enable [ size ]

Default

In Layer 2 mode, an Ethernet interface allows jumbo frames within 1536 bytes to pass through. In Layer 3 mode, an Ethernet interface allows jumbo frames within 10240 bytes to pass through.

Views

Layer 2 Ethernet interface view

Layer 3 Ethernet interface view

Predefined user roles

network-admin

Parameters

size: Sets the maximum length (in bytes) of Ethernet frames that are allowed to pass through.

·     In Layer 2 mode, the value is fixed at 1536.

·     In Layer 3 mode, the value range is 1522 to 10240.

Usage guidelines

If you execute this command multiple times, the most recent configuration takes effect.

Examples

# Allow jumbo frames to pass through GigabitEthernet 0/0/1.

<Sysname> system-view

[Sysname] interface gigabitethernet 0/0/1

[Sysname-GigabitEthernet0/0/1] jumboframe enable

link-flap protect enable

Use link-flap protect enable to enable link flapping protection globally.

Use undo link-flap protect enable to disable link flapping protection globally.

Syntax

link-flap protect enable [ batch [ interval interval | threshold threshold ] * ]

undo link-flap protect enable [ batch [ interval | threshold ] ]

Default

Link flapping protection is disabled globally.

Views

System view

Predefined user roles

network-admin

Parameters

batch: Enables link flapping protection both globally and on all interfaces, and sets the default link flapping detection interval and link flapping detection threshold. If you do not specify this keyword, this command enables link flapping protection only globally.

interval interval: Specifies the link flapping detection interval in seconds. The value range for this argument is 10 to 60. The default value for this argument is 10.

threshold threshold: Specifies the link flapping detection threshold in the range of 5 to 10. The default value for this argument is 5.

Usage guidelines

Link flapping on any interface changes network topology and increases the system overhead. For example, in an active/standby link scenario, when the interface status on the active link changes between UP and DOWN, traffic switches between active and standby links. To solve this problem, execute this command.

With link flapping protection enabled on an interface, when the interface goes down, the system enables link flapping detection on the interface. During the link flapping detection interval, if the number of detected flaps reaches or exceeds the link flapping detection threshold, the system shuts down the interface.

Link flapping protection takes effect only when it is enabled in both the system view and interface view.

Any of the following operations can enable link flapping protection:

·     Execute the link-flap protect enable batch command in system view, and do not configure  link flapping protection on interfaces.

·     Execute the link-flap protect enable batch command in system view, and execute the port link-flap protect enable command in interface view.

·     Execute the link-flap protect enable command in system view, and execute the port link-flap protect enable command in interface view.

The undo link-flap protect enable command works different depending on the keywords specified as follows:

·     If the batch keyword is not specified, this command disables link flapping protection globally.

·     If the batch keyword is specified but the interval or threshold keyword is not specified, this command restores the default for the interval and threshold keywords.

·     If the interval or threshold keyword is specified, this command restores the default for the interval or threshold keyword.

Examples

# Enable link flapping protection on all interfaces.

<Sysname> system-view

[Sysname] link-flap protect enable

Related commands

port link-flap protect enable

loopback

CAUTION

CAUTION:

After you enable loopback testing on an Ethernet interface, the interface does not forward data traffic.

Use loopback to enable loopback testing on an Ethernet interface.

Use undo loopback to disable loopback testing on an Ethernet interface.

Syntax

loopback internal

undo loopback

Default

Loopback testing is disabled on an Ethernet interface.

Views

Ethernet interface view

Predefined user roles

network-admin

Parameters

internal: Enables internal loopback testing on the Ethernet interface.

Usage guidelines

After you enable loopback testing on an Ethernet interface, the Ethernet interface switches to full duplex mode. After you disable loopback testing, the Ethernet interface restores to its duplex setting.

The shutdown and loopback commands are mutually exclusive.

Examples

# Enable internal loopback testing on GigabitEthernet 0/0/1.

<Sysname> system-view

[Sysname] interface gigabitethernet 0/0/1

[Sysname-GigabitEthernet0/0/1] loopback internal

multicast-suppression

Use multicast-suppression to enable multicast storm suppression and set the multicast storm suppression threshold.

Use undo multicast-suppression to disable multicast storm suppression.

Syntax

multicast-suppression pps max-pps

undo multicast-suppression

Default

Ethernet interfaces do not suppress multicast traffic.

Views

Layer 2 Ethernet interface view

Predefined user roles

network-admin

Parameters

pps max-pps: Specifies the maximum number of multicast packets that the interface can forward per second. The value range for the max-pps argument (in pps) is 0 to 1.4881 × the interface bandwidth.

Usage guidelines

The multicast storm suppression feature limits the size of multicast traffic to a threshold on an interface. When the multicast traffic on the interface exceeds this threshold, the system drops packets until the traffic drops below this threshold.

The configured suppression threshold value in pps might be converted into a multiple of a step supported by the chip. As a result, the effective suppression threshold might be different from the configured one. To determine the suppression threshold that takes effect, see the prompts on the device.

Examples

# Set the multicast storm suppression threshold to 12000 pps on GigabitEthernet 0/0/1.

<Sysname> system-view

[Sysname] interface gigabitethernet 0/0/1

[Sysname-GigabitEthernet0/0/1] multicast-suppression pps 12000

Related commands

broadcast-suppression

unicast-suppression

 

 

port ifmonitor crc-error

Use port ifmonitor crc-error to configure CRC error packet alarm parameters for an interface.

Use undo port ifmonitor crc-error to restore the default.

Syntax

port ifmonitor crc-error [ ratio ] high-threshold high-value low-threshold low-value interval interval [ shutdown ]

undo port ifmonitor crc-error

Default

An interface uses the global CRC error packet alarm parameters.

Views

Ethernet interface view

Predefined user roles

network-admin

Parameters

ratio: Specifies the alarm thresholds in percentage. If you do not specify this keyword, you configure the alarm thresholds in absolute value.

high-threshold high-value: Specifies the upper threshold for CRC error packet alarms. If you specify the ratio keyword, the value range is 1 to 100. If you do not specify the ratio keyword, the value range is 1 to 4294967295 packets.

low-threshold low-value: Specifies the lower threshold for CRC error packet alarms. If you specify the ratio keyword, the value range is 1 to 100. If you do not specify the ratio keyword, the value range is 1 to 4294967295 packets.

interval interval: Specifies the statistics collection and comparison interval for CRC error packets, in the range of 1 to 65535 seconds.

shutdown: Shuts down an interface when the number of incoming CRC error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of incoming CRC error packets exceeds the upper threshold on the interface.

Usage guidelines

With the CRC error packet alarm function enabled, when the number of incoming CRC error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of incoming CRC error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.

You can configure the CRC error packet alarm parameters in system view and interface view.

·     The configuration in system view takes effect on all interfaces. The configuration in interface view takes effect only on the current interface.

·     For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.

When you execute this command multiple times, the most recent configuration takes effect.

Examples

# Set the upper threshold to 5000, lower threshold to 400, and statistics collection and comparison interval to 6 seconds for CRC error packet alarms on GigabitEthernet 1/0/1.

<Sysname> system-view

[Sysname] interface gigabitethernet 1/0/1

[Sysname-GigabitEthernet1/0/1] port ifmonitor crc-error high-threshold 5000 low-threshold 400 interval 6

Related commands

snmp-agent trap enable ifmonitor

port ifmonitor input-error

Use port ifmonitor input-error to configure input error packet alarm parameters for an interface.

Use undo port ifmonitor input-error to restore the default.

Syntax

port ifmonitor input-error high-threshold high-value low-threshold low-value interval interval [ shutdown ]

undo port ifmonitor input-error

Default

An interface uses the global input error packet alarm parameters.

Views

Ethernet interface view

Predefined user roles

network-admin

Parameters

high-threshold high-value: Specifies the upper threshold for input error packet alarms, in the range of 1 to 4294967295 packets.

low-threshold low-value: Specifies the lower threshold for input error packet alarms, in the range of 1 to 4294967295 packets.

interval interval: Specifies the statistics collection and comparison interval for input error packets, in the range of 1 to 65535 seconds.

shutdown: Shuts down an interface when the number of input error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of input error packets exceeds the upper threshold on the interface.

Usage guidelines

With the input error packet alarm function enabled, when the number of input error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of input error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.

You can configure the input error packet alarm parameters in system view and interface view.

·     The configuration in system view takes effect on all interfaces. The configuration in interface view takes effect only on the current interface.

·     For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.

When you execute this command multiple times, the most recent configuration takes effect.

Examples

# Set the upper threshold to 5000, lower threshold to 400, and statistics collection and comparison interval to 6 seconds for input error packet alarms on GigabitEthernet 1/0/1.

<Sysname> system-view

[Sysname] interface gigabitethernet 1/0/1

[Sysname-GigabitEthernet1/0/1] port ifmonitor input-error high-threshold 5000 low-threshold 400 interval 6

Related commands

snmp-agent trap enable ifmonitor

port ifmonitor output-error

Use port ifmonitor output-error to configure output error packet alarm parameters for an interface.

Use undo port ifmonitor output-error to restore the default.

Syntax

port ifmonitor output-error high-threshold high-value low-threshold low-value interval interval [ shutdown ]

undo port ifmonitor output-error

Default

An interface uses the global output error packet alarm parameters.

Views

Ethernet interface view

Predefined user roles

network-admin

Parameters

high-threshold high-value: Specifies the upper threshold for output error packet alarms, in the range of 1 to 4294967295 packets.

low-threshold low-value: Specifies the lower threshold for output error packet alarms, in the range of 1 to 4294967295 packets.

interval interval: Specifies the statistics collection and comparison interval for output error packets, in the range of 1 to 65535 seconds.

shutdown: Shuts down an interface when the number of output error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of output error packets exceeds the upper threshold on the interface.

Usage guidelines

With the output error packet alarm function enabled, when the number of output error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of output error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.

You can configure the output error packet alarm parameters in system view and interface view.

·     The configuration in system view takes effect on all interfaces. The configuration in interface view takes effect only on the current interface.

·     For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.

When you execute this command multiple times, the most recent configuration takes effect.

Examples

# Set the upper threshold to 5000, lower threshold to 400, and statistics collection and comparison interval to 6 seconds for output error packet alarms on GigabitEthernet 1/0/1.

<Sysname> system-view

[Sysname] interface gigabitethernet 1/0/1

[Sysname-GigabitEthernet1/0/1] port ifmonitor output-error high-threshold 5000 low-threshold 400 interval 6

Related commands

snmp-agent trap enable ifmonitor

port ifmonitor rx-pause

Use port ifmonitor rx-pause to configure received pause frame alarm parameters for an interface.

Use undo port ifmonitor rx-pause to restore the default.

Syntax

port ifmonitor rx-pause high-threshold high-value low-threshold low-value interval interval

undo port ifmonitor rx-pause

Default

An interface uses the global received pause frame alarm parameters.

Views

Ethernet interface view

Predefined user roles

network-admin

Parameters

high-threshold high-value: Specifies the upper threshold for received pause frame alarms, in the range of 1 to 4294967295.

low-threshold low-value: Specifies the lower threshold for received pause frame alarms, in the range of 1 to 4294967295.

interval interval: Specifies the statistics collection and comparison interval for received pause frame packets, in the range of 1 to 65535 seconds.

Usage guidelines

With the received pause frame alarm function enabled, when the number of received pause frame packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of received pause frame packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.

You can configure the received pause frame alarm parameters in system view and interface view.

·     The configuration in system view takes effect on all interfaces. The configuration in interface view takes effect only on the current interface.

·     For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.

For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the received pause frame alarm function.

When you execute this command multiple times, the most recent configuration takes effect.

Examples

# Set the upper threshold to 90, lower threshold to 50, and statistics collection and comparison interval to 5 seconds for received pause frame alarms on GigabitEthernet 0/0/1.

<Sysname> system-view

[Sysname] interface gigabitethernet 0/0/1

[Sysname-GigabitEthernet0/0/1] port ifmonitor rx-pause high-threshold 90 low-threshold 50 interval 5

Related commands

snmp-agent trap enable ifmonitor

port ifmonitor sdh-b1-error

Use port ifmonitor sdh-b1-error to configure SDH-B1 error packet alarm parameters for an interface.

Use undo port ifmonitor sdh-b1-error to restore the default.

Syntax

port ifmonitor sdh-b1-error high-threshold high-value low-threshold low-value interval interval [ shutdown ]

undo port ifmonitor sdh-b1-error

Default

An interface uses the global SDH-B1 error packet alarm parameters.

Views

Ethernet interface view

Predefined user roles

network-admin

Parameters

high-threshold high-value: Specifies the upper threshold for SDH-B1 error packet alarms, in the range of 1 to 4294967295 packets.

low-threshold low-value: Specifies the lower threshold for SDH-B1 error packet alarms, in the range of 1 to 4294967295 packets.

interval interval: Specifies the statistics collection and comparison interval for SDH-B1 error packets, in the range of 1 to 65535 seconds.

shutdown: Shuts down an interface when the number of incoming SDH-B1 error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of incoming SDH-B1 error packets exceeds the upper threshold on the interface.

Usage guidelines

With the SDH-B1 error packet alarm function enabled, when the number of incoming SDH-B1 error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of incoming SDH-B1 error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.

You can configure the SDH-B1 error packet alarm parameters in system view and interface view.

·     The configuration in system view takes effect on all interfaces. The configuration in interface view takes effect only on the current interface.

·     For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.

For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the SDH-B1 error packet alarm function.

When you execute this command multiple times, the most recent configuration takes effect.

Examples

# Set the upper threshold to 20, lower threshold to 10, and statistics collection and comparison interval to 10 seconds for SDH-B1 error packet alarms on GigabitEthernet 0/0/1.

<Sysname> system-view

[Sysname] interface gigabitethernet 0/0/1

[Sysname-GigabitEthernet0/0/1] port ifmonitor sdh-b1-error high-threshold 20 low-threshold 10 interval 10

Related commands

snmp-agent trap enable ifmonitor

port ifmonitor sdh-b2-error

Use port ifmonitor sdh-b2-error to configure SDH-B2 error packet alarm parameters for an interface.

Use undo port ifmonitor sdh-b2-error to restore the default.

Syntax

port ifmonitor sdh-b2-error high-threshold high-value low-threshold low-value interval interval [ shutdown ]

undo port ifmonitor sdh-b2-error

Default

An interface uses the global SDH-B2 error packet alarm parameters.

Views

Ethernet interface view

Predefined user roles

network-admin

Parameters

high-threshold high-value: Specifies the upper threshold for SDH-B2 error packet alarms, in the range of 1 to 4294967295 packets.

low-threshold low-value: Specifies the lower threshold for SDH-B2 error packet alarms, in the range of 1 to 4294967295 packets.

interval interval: Specifies the statistics collection and comparison interval for SDH-B2 error packets, in the range of 1 to 65535 seconds.

shutdown: Shuts down an interface when the number of incoming SDH-B2 error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of incoming SDH-B2 error packets exceeds the upper threshold on the interface.

Usage guidelines

With the SDH-B2 error packet alarm function enabled, when the number of incoming SDH-B2 error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of incoming SDH-B2 error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.

You can configure the SDH-B2 error packet alarm parameters in system view and interface view.

·     The configuration in system view takes effect on all interfaces. The configuration in interface view takes effect only on the current interface.

·     For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.

For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the SDH-B2 error packet alarm function.

When you execute this command multiple times, the most recent configuration takes effect.

Examples

# Set the upper threshold to 10, lower threshold to 8, and statistics collection and comparison interval to 3 seconds for SDH-B2 error packet alarms on GigabitEthernet 0/0/1.

<Sysname> system-view

[Sysname] interface gigabitethernet 0/0/1

[Sysname-GigabitEthernet0/0/1] port ifmonitor sdh-b2-error high-threshold 10 low-threshold 8 interval 3

Related commands

snmp-agent trap enable ifmonitor

port ifmonitor sdh-error

Use port ifmonitor sdh-error to configure SDH error packet alarm parameters for an interface.

Use undo port ifmonitor sdh-error to restore the default.

Syntax

port ifmonitor sdh-error high-threshold high-value low-threshold low-value interval interval [ shutdown ]

undo port ifmonitor sdh-error

Default

An interface uses the global SDH error packet alarm parameters.

Views

Ethernet interface view

Predefined user roles

network-admin

Parameters

high-threshold high-value: Specifies the upper threshold for SDH error packet alarms, in the range of 1 to 4294967295 packets.

low-threshold low-value: Specifies the lower threshold for SDH error packet alarms, in the range of 1 to 4294967295 packets.

interval interval: Specifies the statistics collection and comparison interval for SDH error packets, in the range of 1 to 65535 seconds.

shutdown: Shuts down an interface when the number of incoming SDH error packets on the interface exceeds the upper threshold. Then, the interface stops forwarding all packets. To recover the interface, execute the undo shutdown command on the interface. If you do not specify this keyword, an upper threshold exceeding alarm is generated and the interface enters the alarm state when the number of incoming SDH error packets exceeds the upper threshold on the interface.

Usage guidelines

With the SDH error packet alarm function enabled, when the number of incoming SDH error packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of incoming SDH error packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.

You can configure the SDH error packet alarm parameters in system view and interface view.

·     The configuration in system view takes effect on all interfaces. The configuration in interface view takes effect only on the current interface.

·     For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.

For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the SDH error packet alarm function.

When you execute this command multiple times, the most recent configuration takes effect.

Examples

# Set the upper threshold to 50, lower threshold to 30, and statistics collection and comparison interval to 10 seconds for SDH error packet alarms on GigabitEthernet 0/0/1.

<Sysname> system-view

[Sysname] interface gigabitethernet 0/0/1

[Sysname-GigabitEthernet0/0/1] port ifmonitor sdh-error high-threshold 50 low-threshold 30 interval 10

Related commands

snmp-agent trap enable ifmonitor

port ifmonitor tx-pause

Use port ifmonitor tx-pause to configure sent pause frame alarm parameters for an interface.

Use undo port ifmonitor tx-pause to restore the default.

Syntax

port ifmonitor tx-pause high-threshold high-value low-threshold low-value interval interval

undo port ifmonitor tx-pause

Default

An interface uses the global sent pause frame alarm parameters.

Views

Ethernet interface view

Predefined user roles

network-admin

Parameters

high-threshold high-value: Specifies the upper threshold for sent pause frame alarms, in the range of 1 to 4294967295.

low-threshold low-value: Specifies the lower threshold for sent pause frame alarms, in the range of 1 to 4294967295.

interval interval: Specifies the statistics collection and comparison interval for sent pause frame packets, in the range of 1 to 65535 seconds.

Usage guidelines

With the sent pause frame alarm function enabled, when the number of sent pause frame packets on an interface in normal state within the specified interval exceeds the upper threshold, the interface generates an upper threshold exceeding alarm and enters the alarm state. When the number of sent pause frame packets on an interface in the alarm state within the specified interval drops below the lower threshold, the interface generates a recovery alarm and restores to the normal state.

You can configure the sent pause frame alarm parameters in system view and interface view.

·     The configuration in system view takes effect on all interfaces. The configuration in interface view takes effect only on the current interface.

·     For an interface, the configuration in interface view takes priority, and the configuration in system view is used only when no configuration is made in interface view.

For this command to take effect, you must use the snmp-agent trap enable ifmonitor command to enable the sent pause frame alarm function.

When you execute this command multiple times, the most recent configuration takes effect.

Examples

# Set the upper threshold to 50, lower threshold to 40, and statistics collection and comparison interval to 8 seconds for sent pause frame alarms on GigabitEthernet 0/0/1.

<Sysname> system-view

[Sysname] interface gigabitethernet 0/0/1

[Sysname-GigabitEthernet0/0/1] port ifmonitor tx-pause high-threshold 50 low-threshold 40 interval 8

Related commands

snmp-agent trap enable ifmonitor

 

port link-flap protect

Use port link-flap protect to configure link flapping protection on an interface.

Use undo port link-flap protect to restore the default.

Syntax

port link-flap protect { disable | enable [ interval interval | threshold threshold ] * }

undo port link-flap protect { disable | enable [ interval | threshold ] }

Default

Link flapping protection is not configured on an interface, and the global link flapping protection configuration applies on the interface.

Views

Ethernet interface view

Predefined user roles

network-admin

Parameters

disable: Disables link flapping protection on the interface.

enable: Enables link flapping protection on the interface.

interval interval: Specifies the link flapping detection interval in seconds. The value range for this argument is 10 to 60. The default value for this argument is 10.

threshold threshold: Specifies the link flapping detection threshold in the range of 5 to 10. The default value for this argument is 5.

Usage guidelines

Link flapping protection takes effect only when it is enabled in both the system view and interface view.

Any of the following operations can enable link flapping protection:

·     Execute the link-flap protect enable batch command in system view, and do not configure  link flapping protection on interfaces.

·     Execute the link-flap protect enable batch command in system view, and execute the port link-flap protect enable command in interface view.

·     Execute the link-flap protect enable command in system view, and execute the port link-flap protect enable command in interface view.

If the interval or threshold keyword is not specified when you execute the port link-flap protect enable command, the command uses the default settings for the interval and threshold keywords.

The undo port link-flap protect command works different depending on the keywords specified as follows:

·     If the disable or enable keyword is not specified, this command restores the default for the link flapping protection function on the interface.

·     If the interval or threshold keyword is specified, this command restores the default for the interval or threshold keyword.

With link flapping protection enabled on an interface, when the interface goes down, the system enables link flapping detection on the interface. During the link flapping detection interval, if the number of detected flaps reaches or exceeds the link flapping detection threshold, the system shuts down the interface.

To bring up an interface that has been shut down by link flapping protection, execute the undo shutdown command.

Examples

# Enable link flapping protection on an interface. Set the link flapping detection interval to 10 seconds, and set the link flapping detection threshold to 5.

<Sysname> system-view

[Sysname] interface gigabitethernet 0/0/1

[Sysname-GigabitEthernet 0/0/1] port link-flap protect enable interval 10 threshold 5

Related commands

link-flap protect enable

port link-mode

Use port link-mode to change the link mode of an Ethernet interface.

Use undo port link-mode to restore the default.

Syntax

port link-mode { bridge | route }

undo port link-mode

Default

The link mode of an Ethernet interface varies by interface card model.

Views

Ethernet interface view

Predefined user roles

network-admin

Parameters

bridge: Specifies the Layer 2 mode.

route: Specifies the Layer 3 mode.

Usage guidelines

CAUTION

CAUTION:

Changing the link mode of an Ethernet interface also restores all commands (except shutdown and combo enable) on the Ethernet interface to their defaults in the new link mode.

 

Interfaces operate differently depending on the hardware structure of interface cards. For a device:

·     Some Ethernet interfaces can operate only as Layer 2 Ethernet interfaces (in bridge mode).

·     Some Ethernet interfaces can operate only as Layer 3 Ethernet interfaces (in route mode).

·     Some Ethernet interfaces can operate either as Layer 2 or Layer 3 Ethernet interfaces. You can use this command to set the link mode to bridge or route for these Ethernet interfaces.

Examples

# Configure GigabitEthernet 0/0/1 to operate in Layer 2 mode.

<Sysname> system-view

[Sysname] interface gigabitethernet 0/0/1

[Sysname-GigabitEthernet0/0/1] port link-mode bridge

reset ethernet statistics

Use reset ethernet statistics to clear the Ethernet module statistics.

Syntax

reset ethernet statistics [ slot slot-number ]

Views

User view

Predefined user roles

network-admin

Parameters

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command clears statistics for all cards.  

Examples

# Clear the Ethernet module statistics.

<Sysname> reset ethernet statistics

Related commands

display ethernet statistics

snmp-agent trap enable ifmonitor

Use snmp-agent trap enable ifmonitor to enable interface alarm functions.

Use undo snmp-agent trap enable ifmonitor to disable interface alarm functions.

Syntax

snmp-agent trap enable ifmonitor [ crc-error | input-error | input-usage | output-error | output-usage | rx-pause | sdh-b1-error | sdh-b2-error | sdh-error | tx-pause ] *

undo snmp-agent trap enable ifmonitor [ crc-error | input-error | input-usage | output-error | output-usage | rx-pause | sdh-b1-error | sdh-b2-error | sdh-error | tx-pause ] *

Default

Interface alarm functions are enabled.

Views

System view

Predefined user roles

network-admin

Parameters

crc-error: Enables the CRC error packet alarm function for interfaces.

input-error: Enables the input error packet alarm function for interfaces.

input-usage: Enables the input bandwidth usage alarm function for interfaces.

output-error: Enables the output error packet alarm function for interfaces.

output-usage: Enables the output bandwidth usage alarm function for interfaces.

rx-pause: Enables the received pause frame alarm function for interfaces.

sdh-b1-error: Enables the SDH-B1 error packet alarm function for interfaces.

sdh-b2-error: Enables the SDH-B2 error packet alarm function for interfaces.

sdh-error: Enables the SDH error packet alarm function for interfaces.

tx-pause: Enables the sent pause frame alarm function for interfaces.

Examples

# Enable the CRC error packet alarm function for interfaces.

<Sysname> system-view

[Sysname] snmp-agent trap enable ifmonitor crc-error

speed

Use speed to set the speed of an Ethernet interface.

Use undo speed to restore the default.

Syntax

speed { 10 | 100 | 1000 | 10000 | auto }

undo speed

Default

The speed of an Ethernet interface is autonegotiated.

Views

Ethernet interface view

Predefined user roles

network-admin

Parameters

10: Sets the interface speed to 10 Mbps.

100: Sets the interface speed to 100 Mbps.

1000: Sets the interface speed to 1000 Mbps.

10000: Sets the interface speed to 10000 Mbps.

auto: Enables the interface to negotiate a speed with its peer.

Usage guidelines

For an Ethernet copper port, use the speed command to set its speed to match the speed of the peer interface. Support of copper ports for keywords of this command varies by copper port type. For more information, use the speed ? command in interface view. If the system does not prompt that operation failed when you configure a speed for a copper port, the copper port supports this speed. Otherwise, the copper port does not support this speed.

For a fiber port, use the speed command to set its speed to match the rate of a transceiver module. Support of fiber ports for keywords of this command varies by fiber port type. For more information, use the speed ? command in interface view. If the system does not prompt that operation failed when you configure a speed for a fiber port, the fiber port supports this speed. Otherwise, the fiber port does not support this speed.

Additionally, you must select a speed for a fiber port according to the transceiver module installed to ensure that the transceiver module can be used properly. If the transceiver module installed in a fiber port does not support the speed for the fiber port, the transceiver module cannot be used. For example, if the transceiver module installed in an SFP+ fiber port is an SFP GE transceiver module and the speed 10000 command is executed on the fiber port, the transceiver module cannot be used.

Examples

# Configure GigabitEthernet 0/0/1 to autonegotiate the speed.

<Sysname> system-view

[Sysname] interface gigabitethernet 0/0/1

[Sysname-GigabitEthernet0/0/1] speed auto

sub-interface rate-statistic

Use sub-interface rate-statistic to enable rate statistics collection for the subinterfaces of an Ethernet interface.

Use undo sub-interface rate-statistic to disable rate statistics collection for the subinterfaces of an Ethernet interface.

Syntax

sub-interface rate-statistic

undo sub-interface rate-statistic

Default

The system does not collect rate statistics for the subinterfaces of an Ethernet interface.

Views

Layer 3 Ethernet interface view

Predefined user roles

network-admin

Usage guidelines

This command is resource intensive. When you use this command, make sure you fully understand its impact on system performance.

Examples

# Enable rate statistics collection for the subinterfaces of GigabitEthernet 0/0/1.

<Sysname> system-view

[Sysname] interface gigabitethernet 0/0/1

[Sysname-GigabitEthernet0/0/1] sub-interface rate-statistic

This configuration may make a negative effect on the performance. Are you sure to continue? [Y/N]:y

unicast-suppression

Use unicast-suppression to enable unknown unicast storm suppression and set the unknown unicast storm suppression threshold.

Use undo unicast-suppression to disable unknown unicast storm suppression.

Syntax

unicast-suppression pps max-pps

undo unicast-suppression

Default

Ethernet interfaces do not suppress unknown unicast traffic.

Views

Layer 2 Ethernet interface view

Predefined user roles

network-admin

Parameters

pps max-pps: Specifies the maximum number of unknown unicast packets that the interface can forward per second. The value range for the max-pps argument (in pps) is 0 to 1.4881 × the interface bandwidth.

Usage guidelines

The unknown unicast storm suppression feature limits the size of unknown unicast traffic to a threshold on an interface. When the unknown unicast traffic on the interface exceeds this threshold, the system discards packets until the unknown unicast traffic drops below this threshold.

The configured suppression threshold value in pps might be converted into a multiple of a step supported by the chip. As a result, the effective suppression threshold might be different from the configured one. To determine the suppression threshold that takes effect, see the prompts on the device.

Examples

# Set the unknown unicast storm suppression threshold to 12000 pps on GigabitEthernet 0/0/1.

<Sysname> system-view

[Sysname] interface gigabitethernet 0/0/1

[Sysname-GigabitEthernet0/0/1] unicast-suppression pps 12000

Related commands

broadcast-suppression

multicast-suppression

Layer 2 Ethernet interface commands

mdix-mode

IMPORTANT

IMPORTANT:

Fiber ports do not support this command.

Use mdix-mode to configure the Medium Dependent Interface Cross-Over (MDIX) mode of an Ethernet interface.

Use undo mdix-mode to restore the default.

Syntax

mdix-mode { automdix | mdi| mdix }

undo mdix-mode

Default

Ethernet interfaces operate in automdix mode.

Views

Layer 2 Ethernet interface view

Predefined user roles

network-admin

Parameters

automdix: Specifies that the interface negotiates pin roles with its peer.

mdi: Specifies that pins 1 and 2 are transmit pins and pins 3 and 6 are receive pins.

mdix: Specifies that pins 1 and 2 are receive pins and pins 3 and 6 are transmit pins.

Examples

# Configure GigabitEthernet 0/0/1 to operate in automdix mode.

<Sysname> system-view

[Sysname] interface gigabitethernet 0/0/1

[Sysname-GigabitEthernet0/0/1] mdix-mode automdix

Layer 3 Ethernet interface or subinterface commands

mac-address

Use mac-address to set the MAC address of an Ethernet interface.

Use undo mac-address to restore the default.

Syntax

mac-address mac-address

undo mac-address

Default

No MAC address is configured for an Ethernet interface.

Views

Layer 3 Ethernet interface view

Predefined user roles

network-admin

Parameters

mac-address: Specifies a MAC address in the format of H-H-H.

Usage guidelines

When you set a MAC address, make sure the following requirements are met:

·     The MAC address must have the same highest 36 bits as the base MAC address.

·     The MAC address must be no lower than the base MAC address plus 160 (decimal).

For more information about base MAC address, see MAC address table in Layer 2—LAN Switching Configuration Guide.

Examples

# Set the MAC address of GigabitEthernet 0/0/1 to 0001-0001-0001.

<Sysname> system-view

[Sysname] interface gigabitethernet 0/0/1

[Sysname-GigabitEthernet0/0/1] mac-address 1-1-1

mtu

Use mtu to set the MTU for an Ethernet interface or subinterface.

Use undo mtu to restore the default.

Syntax

mtu size

undo mtu

Default

The MTU of an Ethernet interface or subinterface is 1500 bytes.

Views

Layer 3 Ethernet interface view

Layer 3 Ethernet subinterface view

Predefined user roles

network-admin

Parameters

size: Sets the MTU in bytes. The value range for this argument is 46 to 9600.

Usage guidelines

A smaller MTU size results in more fragments. When you set the MTU for an interface, consider QoS queue lengths, for example, consider that the default FIFO queue length is 75. To prevent a too small MTU from causing packet drops in QoS queuing, you can perform one of the following configurations:

·     Tune the MTU with the mtu command.

·     Tune QoS queue lengths with the qos fifo queue-length command.

For more information about the qos fifo queue-length command, see ACL and QoS Command Reference.

Examples

# Set the MTU to 1430 bytes for GigabitEthernet 0/0/1.

<Sysname> system-view

[Sysname] interface gigabitethernet 0/0/1

[Sysname-GigabitEthernet0/0/1] mtu 1430

# Set the MTU to 1430 bytes for GigabitEthernet 0/0/1.1.

<Sysname> system-view

[Sysname] interface gigabitethernet 0/0/1.1

[Sysname-GigabitEthernet0/0/1.1] mtu 1430

traffic-statistic enable

Use traffic-statistic enable to enable packet statistics collection for a Layer 3 Ethernet subinterface.

Use undo traffic-statistic enable to disable packet statistics collection for a Layer 3 Ethernet subinterface.

Syntax

traffic-statistic enable

undo traffic-statistic enable

Default

Packet statistics collection is disabled for a Layer 3 Ethernet subinterface.

Views

Layer 3 Ethernet subinterface view

Predefined user roles

network-admin

Usage guidelines

This command is resource intensive. The system becomes busy and the CPU usage increases when you enable this feature on a large number of Ethernet subinterfaces or set a shorter interval by using the flow-interval command.

You can use the display interface or display counters command to display the subinterface packet statistics.

Examples

# Enable packet statistics collection for GigabitEthernet 0/0/1.1.

<Sysname> system-view

[Sysname] interface gigabitethernet 0/0/1.1

[Sysname-GigabitEthernet0/0/1.1] traffic-statistic enable

Related commands

display counters

display interface

flow-interval

 

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become a Partner
  • Partner Resources
  • Partner Business Management
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网