H3C WA6622 Access Point Installation Guide-6W100

HomeSupportWirelessWA6622 Access PointInstall & UpgradeInstallation GuidesH3C WA6622 Access Point Installation Guide-6W100
01-Text
Title Size Download
01-Text 684.56 KB

1 Preparing for installation

Safety recommendations

WARNING

WARNING!

Only qualified personnel can install and remove the AP and its accessories. You must read all safety instructions carefully before working with the AP.

 

To avoid possible bodily injury and equipment damage, read the following safety recommendations before installing the AP. Note that the recommendations do not cover every possible hazardous condition.

·          Take adequate safety measures to avoid bodily injury and device damage.

·          Place the AP in a dry and flat location and take anti-slip measures.

·          Keep the AP clean and dust-free.

·          Do not place the AP in a moist area and avoid liquid intrusion.

·          Keep the AP and installation tools away from walkways.

Site preparation

Before installing the AP, examine the installation site and make sure the AP will operate in a favorable environment. Make sure the temperate and humidity at the installation site meet the requirements in Table1-1.

Table1-1 Temperature and humidity requirements

Item

Specification

Operating temperature

–10°C to +55°C (14°F to 131°F)

Storage temperature

–40°C to +70°C (–40°F to +158°F)

Operating humidity

5% RH to 95% RH, noncondensing

 

Installation accessories

Figure1-1 Accessories provided with the AP

 

Installation tools

When installing the AP, you might need the following tools. Prepare the installation tools yourself as required.

Figure1-2 Installation tools

 


2 Installing the AP

Installation flowchart

Figure2-1 Installation flowchart

 

Pre-installation tasks

Before installing the AP, perform the following tasks:

·          Connect the AP to a power source and the network. Examine the LEDs to verify that the AP is operating correctly. For information about AP LEDs, see "LEDs."

·          Record the MAC address and serial number at the rear of the AP for future use.

·          Make sure you have completed cabling at the installation site.

Determining the installation position

Determine the installation position by observing the following principles:

·          Few obstacles such as wall exist between the AP and clients.

·          The AP is far away from electronic devices (such as microwave oven) that might generate radio frequency (RF) noise.

·          The AP does not hinder people’s daily work and life.

·          The place is not water seeping, water soaking, or condensing.

Mounting the AP

The AP can be installed only indoors. You can mount the AP on a wall or a ceiling.

Mounting the AP on a wall

1.        Place the mounting bracket against the wall and mark the installation holes on the wall.

Figure2-2 Marking the installation holes on the wall

 

2.        Drill holes with a diameter of 6 mm (0.24 in) and a depth of 30 mm (1.18 in) at the marked locations, as shown in Figure2-3.

Figure2-3 Drilling holes in the wall

 

3.        Insert a screw anchor into each hole, and tap the screw anchor with a rubber hammer until it is all flush with the wall surface, as shown in Figure2-4.

Figure2-4 Hammering the screw anchor into the wall

 

4.        Insert the screws through the installation holes in the wall bracket into the holes in the wall. Fasten the screws to secure the mounting bracket to the wall.

Figure2-5 Attaching the mounting bracket to the wall

 

5.        Position the four pegs on the AP into the keyhole slots in the mounting bracket and then slide the AP down until it clicks into place, as shown in Figure2-6.

Figure2-6 Attaching the AP to the mounting bracket

 

Mounting the AP on a ceiling

CAUTION

CAUTION:

The ceiling for installing the AP must be less than 18 mm (0.71 in) in thickness, and can bear a load of 5 kg (11.02 lb). If you must install the AP on a ceiling not strong enough, use boards to reinforce the ceiling.

 

To mount the AP on a ceiling:

1.        Remove the ceiling tile.

2.        Place the mounting bracket against the ceiling tile and mark the installation holes on the ceiling tile.Drill three holes with a diameter of 6 mm (0.24 in) at the marked positions, as shown in Figure2-7.

Figure2-7 Drilling holes in the ceiling tile

 

3.        Thread the pan-head screws through the installation holes in the mounting bracket and into the holes in the ceiling tile. Fasten washers and nuts at the other side of the ceiling to secure the mounting bracket to the ceiling, as shown in Figure2-8.

Figure2-8 Attaching the mounting bracket to the ceiling

 

4.        Position the four pegs on the AP into the keyhole slots in the mounting bracket and slide the AP until it clicks into place, as shown in Figure2-9.

Figure2-9 Attaching the AP to the mounting bracket

 

5.        Verify that the AP is securely installed to prevent it from falling off.

Connecting the AP to a power source

IMPORTANT

IMPORTANT:

The cable cover is not required in the following conditions:

·      Shielded network cables are used to connect Ethernet ports on the AP.

·      A power adapter with a straight connector is used to supply power to the AP.

 

You can supply power to the AP by using a local power source or through 802.3af/802.at PoE as required. Before powering the AP, make sure the power source (the local power source or the PSE) is reliably grounded.

Connecting a PoE power source

CAUTION

CAUTION:

The AP is to be connected only to PoE networks without routing to the outside plant.

 

To power the AP through PoE, use an Ethernet cable to connect an Ethernet port on a PoE switch to the 5GE/PoE+ port on the AP. After connecting all cables to the AP, attach the cable cover securely to the AP.

Figure2-10 Powering the AP through PoE

 

Connecting a local power source

You can use an AC/DC power adapter to connect the AP to a local power source. No power adapter is provided with the AP. Prepare one yourself as required. Table2-1 describes the power adapter specifications.

Table2-1 Power adapter specifications

Item

Specification

Input

100 VAC to 240 VAC

Output

+54 VDC  at 0.74 A

 

Figure2-11 Using a power adapter to connect the AP to a local power source

 

Check after power-on

Examine the LEDs on the AP after you power on it to verify that the AP is operating correctly. For more information about AP LEDs, see "LEDs."

Connecting the AP to the network

All AP settings are configured on the AC. To verify the network connectivity of the AP, execute the display wlan ap all command on the AC. If the AP status is R/M, the AP has been connected to the network.

<Sysname> display wlan ap all

Total number of APs: 1

Total number of connected APs: 1

Total number of connected manual APs: 1

Total number of connected auto APs: 0

Total number of connected common APs: 1

Total number of connected WTUs: 0

Total number of inside APs: 0

Maximum supported APs: 3072

Remaining APs: 3071

Total AP licenses: 128

Remaining AP licenses: 127

AP information

 State : I = Idle,       J  = Join,       JA = JoinAck,    IL = ImageLoad

         C = Config,     DC = DataCheck,  R  = Run   M = Master,  B = Backup

AP name        APID      State      Model             Serial ID

ap1             1          R          WA6622            219801A24H8192E00021


3 Appendix A Technical specifications

Table3-1 Technical specifications

Item

Specification

Dimensions (H × W × D) (without the mounting bracket)

45 × 215 × 215 mm (1.77 × 8.46 × 8.46 in)

Weight

940 g (33.16 oz)

Antenna (built-in)

·         2.4 G: gain of 3 dBi

·         5 G: gain of 5 dBi

System power consumption

·         ≤ 19.9 W (not supplying PoE power)

·         ≤ 35.5 W (supplying PoE power)

·         ≤ 12.93 W (Not supplying PoE power and with the radios operating in 1×1 MIMO mode)

Powering option

·         Local DC power source

·         802.3at PoE (the system power consumption ≤ 19.9 W)

·         802.3af PoE (the system power consumption ≤ 12.93 W)

Protocol

·         802.11b/g/a/n/ac/ax

·         802.3at/af

 


4 Appendix B Ports and LEDs

Ports

The AP provides the following ports:

·          One console port

·          One USB port

·          One GE port

·          One 5GE port

·          One power port

The AP also has a reset button and a security slot. The security slot is 7 × 3 mm (0.28 × 0.12 in) in size.

Figure4-1 Ports on the AP

(1) Reset button

(2) Console port

(3) USB port

(4) 10/100/1000M Ethernet copper port

(5) 100/1000/2500/5000M Ethernet copper port

(6) Power port

(7) Security slot

 

Table4-1 Port and button descriptions

Port

Standards and protocols

Description

Reset button

N/A

·         To reset the AP, press and hold the button for no more than 5 seconds.

·         To restore the factory default, press and hold the button for more than 5 seconds.

Console port

RS/EIA-232

Used for device configuration and management only.

USB port

USB 2.0

N/A

10/100/1000M Ethernet copper port (GE/PSE)

·         IEEE802.3

·         IEEE802.3u

·         IEEE802.3af

·         IEEE802.3at

Used for connecting a downlink device. It can also supply PoE power to the downlink device.

It is represented by interface number GE1/0/1 in the MAP file and gigabitethernet 1 for configuration on the AC.

100/1000/2500/5000M Ethernet copper port (5GE/PoE+)

·         IEEE802.3

·         IEEE802.3u

·         IEEE802.3af

·         IEEE802.3at

Used for connecting the AP to an uplink device for Internet or MAN access. It can also receive PoE+ power from the uplink device.

It is represented by interface number SGE1/0/1 in the MAP file and smartrate-ethernet 1 for configuration on the AC.

Power port (54 V)

N/A

Used for receiving +54 VDC power from the local power source.

 

LEDs

Table4-2 LED descriptions

LED

Status

Description

Off

No power is present or the LED has been turned off from the CLI.

Yellow

Steady on

The AP is initializing, or an initialization exception has occurred.

Flashing at 1 Hz

No radio cards have been detected.

Flashing at 2 Hz

The Ethernet interfaces are down and no mesh links are established.

Green

Steady on

The AP has registered to an AC, but does not have any associated clients.

Flashing at 0.5 Hz

The AP has started up but has not registered to any AC.

Flashing at 1 Hz

Only the 2.4G radio has associated clients.

Flashing at 2 Hz

The AP is upgrading the image.

Blue

Flashing at 1 Hz

Only the 5G radio has associated clients.

Alternating between green and blue at 1 Hz

Both the 2.4G and 5G radios have associated clients.

 

 

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become a Partner
  • Partner Resources
  • Partner Business Management
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网