Configuring EVB

Overview

Edge Virtual Bridging (EVB) allows virtual machines (VMs) on a physical server to obtain bridge relay services through a common bridge port. It enables coordinated configuration and management of bridge services for VMs.

EVB requires a license to run on your device. For information about obtaining a license, see Fundamentals Configuration Guide.

Data center virtualization includes network virtualization, storage virtualization, and server virtualization. Server virtualization uses specific virtualization software such as VMware to create VMs on a single physical server. Each VM operates independently and has its own operating system, applications, and virtual hardware environments as shown in Figure 1.

Figure 1 Server virtualization

 

VMs on a physical server communicate with each other or with the outside network through a Virtual Ethernet Bridge (VEB). VEBs are implemented through software or hardware such as NICs. Both implementation methods have the following limitations:

·           Lack of traffic monitoring capabilities such as packets statistics, traffic mirroring, and NetStream.

·           Lack of network policy enforcement capabilities, such as QoS.

·           Lack of management scalability, especially in unified deployment of the internal server network and the external network.

EVB solves these limitations. It uses a physical switch (called EVB bridge) to switch traffic for VMs on a directly connected physical server (called EVB station). EVB implements traffic monitoring, network policy enforcement, and unified network deployment and management for VMs.

Basic concepts

Figure 2 shows the components on the EVB station and EVB bridge.

Figure 2 EVB architecture

 

·           Edge RelayAn ER transfers packets between one URP and one or more DRPs. An ER has one or more DRPs and one URP. Both URP and DRPs are called ER ports. An EVB station can have multiple ERs.

·           S-channel—A point-to-point S-VLAN established between a Port-mapping S-VLAN component in an EVB station and a Port-mapping S-VLAN component in an EVB bridge. An S-channel corresponds to the URP of an ER. On an EVB bridge, the end point of an S-channel is known as an S-channel interface. An S-channel is identified by the S-VLAN Identifier (SVID) and the S-channel Identifier (SCID), and the two values together are called an (SCID, SVID) pair.

·           Virtual Station Interface—A VSI is a port on a VM that directly connects to the DRP of an ER. A VSI is associated with a logical entity called VSI instance, which is identified by the VSI Instance Identifier (VSIID). A VSI is associated with a virtual interface called VSI interface on the EVB bridge port to implement VM traffic management and policy configuration. A VSI interface can be considered as a subinterface of an S-channel.

·           Reflective Relay—A RR is an operation mode in which a received frame on a port that supports this function can be forwarded out of the same port. The EVB bridge uses this mode to forward traffic among VMs on an EVB station, as shown in Figure 2.

EVB working mechanism

An EVB station and an EVB bridge go through the following steps to implement VM traffic management:

1.      Use the S-channel Discovery and Configuration Protocol (CDCP) to establish an S-channel.

CDCP is used to configure S-channels between stations and bridges. When a station creates or deletes an S-channel, CDCP sends a CDCP TLV in an LLDP packet that is addressed using the Nearest non-TPMR Bridge address to the bridge. The bridge creates or deletes the S-channel.

2.      Exchange EVB TLVs through LLDP to negotiate EVB capabilities for the S-channel, such as RR, ECP parameters, and VDP parameters.

3.      Use the VSI Discovery and Configuration Protocol (VDP) to associate the VSIs of VMs with the bridge port.

The bridge uses the VSI interfaces to manage traffic for VMs.

VDP manages the association between a VSI and a station-facing bridge port (SBP) on a bridge. VDP uses the Edge Control Protocol (ECP) to carry VDP TLVs. A VDP TLV comprises the VSIID, VSI type, and VSI version.

When a station creates a VM, it sends a VDP pre-associate, pre-associate with resource reservation, or associate packet to the bridge. The bridge sends the request to a VSI manager. The VSI manager notifies the bridge to create a VSI interface and apply policies.

When a station shuts down a VM, it sends a VDP de-associate packet to the bridge. The bridge sends the request to the VSI manager. The VSI manager notifies the bridge to delete the VSI interface.

Protocols and standards

·           IEEE P802.1Qbg/D2.2, Draft Standard for Local and Metropolitan Area Networks—MAC Bridges and Virtual Bridged Local Area Networks - Amendment XX: Edge Virtual Bridging

EVB configuration task list

This document only describes EVB bridge configuration. For information about EVB station configuration, see the station manual.

 

Tasks at a glance

Enabling EVB

Configuring LLDP

(Optional.) Specifying a default VSI manager

(Optional.) Configuring VDP negotiation parameters

(Optional.) Configuring an S-channel:

·          Creating an S-channel

·          Configuring an S-channel interface or S-channel aggregate interface

·          Configuring the RR mode for an S-channel

·          Configuring MAC address learning for an S-channel

(Optional.) Configuring a VSI interface or VSI aggregate interface:

·          Creating a VSI interface or VSI aggregate interface

·          Configuring VSI filters

·          Activating a VSI interface or VSI aggregate interface

 

Enabling EVB

Perform this task to enable EVB on an interface that directly connects to a station. After that, you must configure the interface to operate in trunk mode. Otherwise, EVB does not work because VSI filter configuration (see "Configuring VSI filters") does not take effect.

After EVB is enabled on an interface, the device cannot perform Layer 3 forwarding to the data received on the interface.

A default S-channel is created on an interface after EVB is enabled on the interface. Both SCID and SVID are 1. After an S-channel is created, an S-channel interface or S-channel aggregate interface is created and operates in access mode.

Do not enable both EVB and VLAN mapping, both EVB and TRILL, or both EVB and QinQ on the same interface.

Do not assign interfaces enabled with EVB and not configured with the trill evb-support command to the same VLAN as interfaces enabled with TRILL. For more information about TRILL, see TRILL Configuration Guide. For more information about the trill evb-support command, see TRILL Command Reference.

To enable EVB:

 

Step

Command

Remarks

1.      Enter system view.

system-view

N/A

2.      Enter Layer 2 Ethernet interface view or Layer 2 aggregate interface view.

interface interface-type interface-number

N/A

3.      Enable EVB.

evb enable

By default, EVB is disabled on an interface.

 

Configuring LLDP

EVB uses LLDP to transmit CDCP TLVs, and CDCP TLVs are carried by the LLDP packet that is addressed using the Nearest non-TPMR Bridge address, so you must configure LLDP.

For detailed information about the lldp global enable, lldp enable and lldp agent nearest-nontpmr admin-status commands, see Layer 2—LAN Switching Command Reference.

To configure LLDP:

 

Step

Command

Remarks

1.      Enter system view.

system-view

N/A

2.      Enable LLDP globally.

lldp global enable

By default, LLDP is disabled globally.

3.      Enter Layer 2 Ethernet interface view or Layer 2 aggregate interface view.

interface interface-type interface-number

N/A

4.      Enable LLDP on the interface

lldp enable

By default, LLDP is enabled on an interface.

5.      Configure the Nearest non-TPMR Bridge agent for LLDP to operate in TxRx mode.

lldp agent nearest-nontpmr admin-status txrx

The default mode is disable.

 

Specifying a default VSI manager

When the bridge receives a VDP packet (except for a De-Associate packet) from a station, it contacts the VSI manager specified in the VDP packet to get VSI interface resources and policies.

The VSI manager ID TLV in a VDP packet carries the VSI manager's IP address. If the value for the TLV is 0, the VDP packet does not contain a VSI manager's IP address, so the bridge communicates with the specified default VSI manager.

To specify a default VSI manager:

 

Step

Command

Remarks

1.      Enter system view.

system-view

N/A

2.      Specify a default VSI manager.

evb default-manager { { ip ip-address | ipv6 ipv6-address | name name } [ port port-number ] | local-server }

By default, no default VSI manager is specified.

 

Configuring VDP negotiation parameters

After a station sends a VDP request other than a De-Associate request to the bridge, the bridge requests the VSI interface resources and policies from the VSI manager. If the bridge receives no response from the VSI manager before the VDP response-wait-delay time expires, the VDP negotiation fails. The VDP response-wait-delay time on the EVB bridge is calculated as:

VDP response-wait-delay time (seconds) = 2VDP resource-wait-delay × 105.

The value of the VDP resource wait-delay exponent is the larger of the values proposed by the station and bridge through EVB TLV.

When a Pre-Associate, Pre-Associate with Resource Reservation, or Associate request from a station is successfully handled, the VSI manager notifies the bridge to create a VSI interface for the corresponding VM. Then the bridge starts a "VDP keepalive timer" for the VSI interface. If the bridge receives no keepalive from the station before the timer expires, it releases resources reserved for the association. The VDP keepalive time is calculated as:

VDP keepalive time (seconds) = 1.5 × [ 2VDP keepalive + (2 × ECP maximum retransmission time + 1) × 2ECP retransmission ] × 105.

The value assigned to the VDP keepalive exponent, the ECP maximum retransmission time, and the ECP retransmission exponent are the larger of the values proposed for each by the station and bridge through EVB TLV.

To configure VDP negotiation parameters:

 

Step

Command

Remarks

1.      Enter system view.

system-view

N/A

2.      Enter Layer 2 Ethernet interface view or Layer 2 aggregate interface view.

interface interface-type interface-number

N/A

3.      Configure the VDP resource-wait-delay timer exponent.

evb vdp timer resource-wait-delay exponent value

The default is 20.

4.      Configure the VDP keepalive timer exponent.

evb vdp timer keepalive exponent value

The default is 20.

 

Configuring an S-channel

Creating an S-channel

An S-channel is automatically created by CDCP, and the system automatically saves the configuration in the configuration file on the bridge. You can also manually create an S-channel by performing this task. If an (SCID, SVID) pair for an S-channel is created both automatically and manually, the one automatically created takes precedence.

After an S-channel is created, an S-channel interface or S-channel aggregate interface is generated. Removing an S-channel also removes the S-channel interface or S-channel aggregate interface. A manually created S-channel interface or S-channel aggregate interface operates in access mode. An S-channel interface or S-channel aggregate interface that is automatically created through CDCP operates in trunk mode.

An S-channel interface is associated with the S-channel that is created on a Layer 2 Ethernet interface. An S-channel aggregate interface is associated with the S-channel that is created on a Layer 2 aggregate interface.

The device checks C-VLAN tagged frames (frames taking the original VLAN tags) entering an S-channel for their C-VLAN tags. If the C-VLAN does not belong to the VLANs that the S-channel and the port where the S-channel is created permit, the device cannot transmit the frames. Therefore, you must specify the C-VLAN range for the frames that an S-channel can transmit before you assign the S-channel and the port where the S-channel is created to these C-VLANs. For more information about assigning ports to a VLAN, see Layer 2—LAN Switching Configuration Guide.

When you create an S-channel, follow these guidelines:

·           Create an S-channel on an interface with EVB enabled. Otherwise, an error message appears.

·           After EVB is enabled on an interface, a default S-channel (with both SCID and SVID as 1) is automatically created.

·           When you manually create an S-channel, do not use the SCID or SVID being used by any other S-channel. Otherwise, an error message appears.

·           To manually create or remove S-channel, disable CDCP that automatically performs these operations.

To create an S-channel:

 

Step

Command

Remarks

1.      Enter system view.

system-view

N/A

2.      Enter Layer 2 Ethernet interface view or Layer 2 aggregate interface view.

interface interface-type interface-number

N/A

3.      Create an S-channel.

evb s-channel channel-id service-vlan svlan-id

By default, only an automatically created default S-channel (with both SCID and SVID as 1) exists on an interface with EVB enabled.

 

Configuring an S-channel interface or S-channel aggregate interface

To configure an S-channel interface or S-channel aggregate interface:

 

Step

Command

Remarks

1.      Enter system view.

system-view

N/A

2.      Enter S-channel interface or S-channel aggregate interface view.

interface { s-channel | schannel-aggregation } interface-number:channel-id

N/A

3.      (Optional.) Configure the expected bandwidth of the interface.

bandwidth bandwidth-value

By default, the expected bandwidth of an S-channel interface or S-channel aggregate interface is the default maximum bandwidth of the physical port to which the interface belongs.

4.      (Optional.) Restore the default settings for the interface.

default

N/A

5.      (Optional.) Configure a description for the interface.

description text

The default description information is "interface name Interface."

6.      Bring up the interface.

undo shutdown

By default, the S-channel interface or S-channel aggregate interface is up.

 

Configuring the RR mode for an S-channel

EVB TLVs exchanged through LLDP allow an EVB station and EVB bridge to negotiate the use of reflective relay. When the EVB station requests the use of the RR mode and the EVB bridge supports the RR mode, the bridge performs the following tasks:

·           Automatically enables the RR mode for the S-channel.

·           Saves the configuration in the configuration file on the bridge.

You can also manually enable the RR mode for an S-channel by performing this task.

To configure the RR mode for an S-channel:

 

Step

Command

Remarks

1.      Enter system view.

system-view

N/A

2.      Enter S-channel interface view or S-channel aggregate interface view.

interface { s-channel | schannel-aggregation } interface-number:channel-id

N/A

3.      Enable the RR mode for the S-channel.

evb reflective-relay

By default, the RR mode is disabled for an S-channel.

 

Configuring MAC address learning for an S-channel

You can manually disable the MAC address learning function for an S-channel by performing this task.

To disable MAC address learning for an S-channel:

 

Step

Command

Remarks

1.      Enter system view.

system-view

N/A

2.      Enter S-channel interface view or S-channel aggregate interface view.

interface { s-channel | schannel-aggregation } interface-number:channel-id

N/A

3.      Disable MAC address learning for the S-channel.

evb mac-learning forbidden

By default, the MAC address learning function is enabled for an S-channel.

IMPORTANT IMPORTANT:

·          For an S-channel with the RR mode disabled, do not disable its MAC address learning function. Otherwise, the bridge might fail to forward traffic for VMs on the EVB station.

·          After you disable the MAC address learning function for an S-channel, the bridge will discard packets with an unknown source MAC address.

 

Configuring a VSI interface or VSI aggregate interface

Creating a VSI interface or VSI aggregate interface

A VSI interface is created on an S-channel interface through this task, and it is a subinterface of the S-channel interface. A VSI aggregate interface is created on an S-channel aggregate interface, and it is a subinterface of the S-channel aggregate interface. Removing an S-channel also removes all its VSI interfaces and VSI aggregate interfaces.

VSI interfaces or VSI aggregate interfaces are typically created by a VSI manager. You can create a VSI interface or VSI aggregate interface, or modify its Pre-Associate and Associate properties through this task.

To create a VSI interface or VSI aggregate interface:

 

Step

Command

Remarks

1.      Enter system view.

system-view

N/A

2.      Enter S-channel interface view or S-channel aggregate interface view.

interface { s-channel | schannel-aggregation } interface-number:channel-id

N/A

3.      Create a VSI interface or VSI aggregate interface.

evb vsi vsi-local-id { association | pre-association }

By default, no VSI interface or VSI aggregate interface exists on an S-channel.

 

Configuring VSI filters

The EVB bridge uses a VSI filter to identify VSI traffic for a VM. Filters are usually assigned by a VSI manager. You can manually create or remove VSI filters through this task.

A VSI filter contains a set of VID values, MAC addresses, and group ID values. EVB supports the following filter info formats:

·           VLAN ID

·           VLAN ID + MAC

·           Group ID + VLAN ID

·           Group ID + VLAN ID + MAC

When you configure VSI filters on a VSI interface, follow these guidelines:

·           Before you configure a VSI filter on a VSI interface, make sure the S-channel interface to which the VSI interface belongs operates in trunk mode. Otherwise, the VSI filter configuration fails.

·           After you configure a VSI filter on a VSI interface, an S-channel interface automatically permits the VLAN that is configured in the VSI filter for the subordinate VSI interface. The same rule takes effect on Layer 2 interfaces associated with S-channels.

·           When you delete a VSI filter that contains information about a VLAN on a VSI interface, the other VSI filters on all VSI interfaces of an S-channel interface might not contain the VLAN. If they do not, the S-channel interface automatically denies traffic from the VLAN that is configured on the VSI filter. The same rule takes effect on Layer 2 interfaces associated with S-channels.

·           When a filter configured on a VSI contains information about a VLAN, you must not configure the filter on the same VSI interface again or on other VSI interfaces of the S-channel interface. If you do, an error message appears.

·           If the VSI filter is a set of VID values, and the MAC address learning function for the corresponding S-channel is disabled, traffic for the VSI cannot be forwarded.

·           Activate a VSI interface after configuring a VSI filter, and deactivate a VSI interface before removing a VSI filter.

When you configure VSI filters on a VSI aggregate interface, follow these guidelines:

·           Before you configure a VSI filter on a VSI aggregate interface, make sure the S-channel aggregate interface to which the VSI aggregate interface belongs operates in trunk mode. Otherwise, the VSI filter configuration fails.

·           After you configure a VSI filter on a VSI aggregate interface, an S-channel aggregate interface automatically permits the VLAN that is configured in the VSI filter for the subordinate VSI aggregate interface. The same rule takes effect on Layer 2 aggregate interfaces associated with S-channels.

·           When you delete a VSI filter that contains information about a VLAN on a VSI aggregate interface, the other VSI filters on all VSI aggregate interfaces of an S-channel aggregate interface might not contain the VLAN. If they do not, the S-channel aggregate interface automatically denies traffic from the VLAN that is configured on the VSI filter. The same rule takes effect on Layer 2 aggregate interfaces associated with S-channels.

·           When a filter configured on a VSI aggregate interface contains information about a VLAN, you must not configure the filter on the same VSI aggregate interface again or on other VSI aggregate interfaces of the S-channel aggregate interface. If you do, an error message appears.

·           Activate a VSI aggregate interface after configuring a VSI filter, and deactivate a VSI aggregate interface before removing a VSI filter.

To configure a VSI filter:

 

Step

Command

Remarks

1.      Enter system view.

system-view

N/A

2.      Enter VSI interface view or VSI aggregate interface view.

interface { s-channel | schannel-aggregation } interface-number:channel-id.vsi-local-id

N/A

3.      Configure a VSI filter.

evb vsi filter [ group group-id ] vlan vlan-id [ mac mac-address ]

By default, no VSI filter is configured.

 

Activating a VSI interface or VSI aggregate interface

Settings such as traffic monitoring (see ACL and QoS Configuration Guide) on a VSI interface or VSI aggregate interface take effect only after the VSI interface or VSI aggregate interface is activated. When a VSI interface or VSI aggregate interface is not activated, only configure filters on the VSI interface or VSI aggregate interface.

Activate a VSI interface or VSI aggregate interface after configuring a VSI filter, and deactivate a VSI interface or VSI aggregate interface before removing a VSI filter.

To activate a VSI interface or VSI aggregate interface:

 

Step

Command

Remarks

1.      Enter system view.

system-view

N/A

2.      Enter VSI interface view or VSI aggregate interface view.

interface { s-channel | schannel-aggregation } interface-number:channel-id.vsi-local-id

N/A

3.      (Optional.) Configure the expected bandwidth of the VSI interface or VSI aggregate interface.

bandwidth bandwidth-value

By default, the expected bandwidth of a VSI interface or VSI aggregate interface is the default maximum bandwidth of the physical port to which the VSI interface or VSI aggregate interface belongs.

4.      (Optional.) Restore the default settings for the VSI interface or VSI aggregate interface.

default

N/A

5.      (Optional.) Configure a description for the VSI interface or VSI aggregate interface.

description text

The default description information is "interface name Interface."

6.      Activate the VSI interface or VSI aggregate interface.

evb vsi active

By default, no VSI interface or VSI aggregate interface is activated.

 

Displaying and maintaining EVB

Execute display commands in any view and the reset command in user view.

 

Task

Command

Display CDCP negotiation information.

display evb cdcp [ interface interface-type interface-number ]

Display S-channel EVB TLV negotiation information.

display evb evb-tlv [ interface interface-type { interface-number | interface-number:channel-id } ]

Display S-channel information.

display evb s-channel [ interface interface-type interface-number ]

Display EVB summary.

display evb summary

Display VSI interface information.

display evb vsi [ verbose ] [ interface interface-type { interface-number | interface-number:channel-id | interface-number:channel-id.vsi-local-id } ]

Display information about an S-channel interface, S-channel aggregate interface, VSI interface, or a VSI aggregate interface.

·          display interface [ s-channel | schannel-aggregation ] [ brief [ down ] ]

·          display interface [ { s-channel | schannel-aggregation } [ interface-number:channel-id | interface-number:channel-id.vsi-local-id ] ] [ brief [ description ] ]

Clear statistics for an S-channel interface, S-channel aggregate interface, VSI interface, or a VSI aggregate interface.

reset counters interface [ { s-channel | schannel-aggregation } [ interface-number:channel-id | interface-number:channel-id.vsi-local-id ] ]

 

EVB configuration example

Network requirements

As shown in Figure 3, the Layer 2 network of a data center comprises two switches that form an IRF fabric, four EVB bridges, and four EVB stations. They communicate within VLAN 100.

Create VM 1 with a MAC address of 0050-5684-21C7 on EVB station 1, and set VM1 as the FTP server with a CIR of 2048 kbps and a PIR of 4096 kbps. Only the R&D center is allowed to access the network.

Figure 3 Network diagram

 

Configuration procedure

This section only contains EVB settings.

1.      Configure the EVB bridge:

# Create VLAN 100 on EVB bridge 1.

<EVB_bridge1> system-view

[EVB_bridge1] vlan 100

[EVB_bridge1-vlan100] quit

# Enable EVB on Ten-GigabitEthernet 1/0/1 that connects to EVB station 1, and configure Ten-GigabitEthernet 1/0/1 to operate in trunk mode.

[EVB_bridge1] interface ten-gigabitethernet 1/0/1

[EVB_bridge1-Ten-GigabitEthernet1/0/1] evb enable

[EVB_bridge1-Ten-GigabitEthernet1/0/1] port link-type trunk

[EVB_bridge1-Ten-GigabitEthernet1/0/1] quit

# Enable LLDP on EVB bridge 1 globally. Enable LLDP on Ten-GigabitEthernet 1/0/1, and configure the Nearest non-TPMR Bridge agent for LLDP to operate in TxRx mode.

[EVB_bridge1] lldp global enable

[EVB_bridge1] interface ten-gigabitethernet 1/0/1

[EVB_bridge1-Ten-GigabitEthernet1/0/1] lldp enable

[EVB_bridge1-Ten-GigabitEthernet1/0/1] lldp agent nearest-nontpmr admin-status txrx

[EVB_bridge1-Ten-GigabitEthernet1/0/1] quit

# Specify the IP address and port number for the default VSI manager on EVB bridge 1.

[EVB_bridge1] evb default-manager ip 192.168.1.1 port 8080

Configure other EVB bridges in the same way. (Details not shown.)

2.      Configure the EVB station:

Configure the EVB station on the VMM. For more information about configuring VMs through the VMM, see the VMM manual. (Details not shown.)

3.      Configure the NMS:

Use VAN Connection Manager of IMC on the NMS to configure network resources.

The IMC VCM 5.2 (E0401L01) version is used in this section.

Figure 4 VAN Connection Manager

 

To configure the NMS, log in to IMC, click the Resource tab, and select VAN Connection Manager from the navigation tree (see Figure 4), and perform the following steps:

a.    Add an EVB bridge (Edge Switch):

Select Edge Switch from the navigation tree, click Add on the page that appears, select the four devices in the IP address range of 192.168.1.11 through 192.168.1.14 from IP View, and click OK.

EVB bridge 1, EVB bridge 2, EVB bridge 3, and EVB bridge 4 are displayed in the Edge Switch List page, as shown in Figure 5.

Figure 5 Edge Switch List page

 

b.    Add an FTP network:

Select Network from the navigation tree, click Add on the page that appears, enter For FTP for Name, 100 for VLAN ID, and 10 for Max. Connections, and click OK.

The network name For FTP is displayed in the Network List page, as shown in Figure 6.

Figure 6 Network List page

 

c.    Define the VSI type of VM 1:

i      Select VSI Type from the navigation tree. The VSI Type List page appears.

ii     Click Add.

iii    On the page that appears, do the following:

-       Enter VM1 VSI for Name.

-       Select For FTP from the Network list, and select the Bandwidth Control and VM Access Control options.

-       Enter 172.16.1.0 for Client IP and 0.0.0.255 for Wildcard Mask.

-       Select BOTH from the Filtering Direction list.

-       Enter 2048 for CIR (kbps) and 4096 for PIR (kbps).

iv    Click Save and Release.

The VSI type VM1 VSI is displayed in the VSI Type List page, as shown in Figure 7.

Figure 7 VSI Type List page

 

d.    Bind the VSI type VM1 VSI to the vNIC of VM 1 to define the connection:

i      Select Connection from the navigation tree. The Connection List page appears.

ii     Click Add.

iii    On the page that appears, do the following:

-       Enter VM1CON for Name.

-       Click Select on the right side of the page, select the VM1 option from the popup window, and then click OK (the MAC address 0050-5684-21c7 of VM 1 is displayed in the vNIC field).

-       Select For FTP from the Network list, VM1 VSI from VSI Type, and VM1 VSI (V1) from VSI Type Version.

iv    Click OK.

The connection VM1CON is displayed in the Connection List page, as shown in Figure 8.

Figure 8 Connection List page

 

4.      Verify the configuration:

After VM 1 starts, the VAN Connection Manager service component of IMC deploys the VSI type VM1 VSI on EVB bridge 1. Only the R&D center can use the FTP service on VM 1.

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become a Partner
  • Partner Resources
  • Partner Business Management
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网