Introduction

This document provides software patching examples that use ISSU install commands.

Prerequisites

The configuration examples in this document were created and verified in a lab environment, and all the devices were started with the factory default configuration. When you are working on a live network, make sure you understand the potential impact of every command on your network.

Example: Patching software

Network configuration

As shown in Figure 1, the two-chassis IRF fabric and the TFTP server can reach each other. The IRF members are running CMW710-SYSTEM-T0001016, and they have not been patched before.

Use the patch image file CMW710-SYSTEM-T0001016H04.bin to fix bugs without rebooting the members.

Figure 1 Network diagram

 

Applicable hardware and software versions

The following matrix shows the hardware and software versions to which this configuration example is applicable:

 

Hardware

Software version

S6520XE-HI switch series

Supported in Release 11xx

S5560X-EI switch series

Supported in Release 111x

S5500V2-EI switch series

Supported in Release 111x

MS4520V2-30F switch

Supported in Release 111x

S5560S-EI switch series

S5560S-SI switch series

Supported in Release 612x

S5130S-HI switch series

S5130S-EI switch series

S5130S-SI switch series

S5130S-LI switch series

Supported in Release 612x

S5120V2-SI switch series

S5120V2-LI switch series

Supported in Release 612x

S3100V3-EI switch series

S3100V3-SI switch series

Supported in Release 612x

S5110V2 switch series

Supported in Release 612x

S5110V2-SI switch series

Supported in Release 612x

S5000V3-EI switch series

Supported in Release 612x

S5000E-X switch series

Supported in Release 612x

WAS6000 switch series

Supported in Release 612x

E128C switch

E152C switch

E500C switch series

E500D switch series

Supported in Release 612x

MS4520V2 switch series (except the MS4520V2-30F switch)

Supported in Release 612x

MS4320V2 switch series

MS4300V2 switch series

MS4320 switch series

MS4200 switch series

Supported in Release 612x

WS5850-WiNet switch series

Supported in Release 612x

WS5820-WiNet switch series

WS5810-WiNet switch series

Supported in Release 612x

 

Restrictions and guidelines

When you patch software for a centralized IRF device, follow these restrictions and guidelines:

·     The first time you install patch images, you must start with the master. For subsequent patch installations, you must start with the subordinate members.

·     The patch image version must match the device model and Comware version. For example, to fix bugs in CMW710-SYSTEM-T0001016, you must use CMW710-SYSTEM-T0001016H04.bin.

Procedures

# Download the patch image file CMW710-SYSTEM-T0001016H04.bin from the TFTP server to the root directory of the flash memory on the master.

<Sysname> tftp 2.2.2.2 get CMW710-SYSTEM-T0001016H04.bin

Press CTRL+C to abort.

  % Total    % Received % Xferd  Average Speed   Time    Time     Time  Current

                                 Dload  Upload   Total   Spent    Left  Speed

100 25.2M    0 25.2M    0     0   210k      0 --:--:--  0:02:02 --:--:--  209k

# Activate the patch images on the master first and then on the subordinate member. This sequence is used because no patch images have been activated on the IRF fabric.

<Sysname> install activate patch flash:/CMW710-SYSTEM-T0001016H04.bin slot 1

This operation maybe take several minutes, please wait.............Done.

<Sysname> install activate patch flash:/CMW710-SYSTEM-T0001016H04.bin slot 2

This operation maybe take several minutes, please wait.............Done.

The patch images take effect immediately after they are activated.

# For the patch images to take effect after a reboot, commit the software changes.

<Sysname> install commit

Verifying the configuration

# Verify that the patch images have been activated successfully.

<Sysname> display install active

Active packages on slot 1:

  flash:/CMW710-BOOT-T0001016.bin

  flash:/CMW710-SYSTEM-T0001016.bin

  flash:/CMW710-SYSTEM-T0001016H04.bin

Active packages on slot 2:

  flash:/CMW710-BOOT-T0001016.bin

  flash:/CMW710-SYSTEM-T0001016.bin

  flash:/CMW710-SYSTEM-T0001016H04.bin

# Verify that the patch image file has been added to the main startup software image list so the images can take effect after a reboot.

<Sysname> display install committed

Committed packages on slot 1:

  flash:/CMW710-BOOT-T0001016.bin

  flash:/CMW710-SYSTEM-T0001016.bin

  flash:/CMW710-SYSTEM-T0001016H04.bin

Committed packages on slot 2:

  flash:/CMW710-BOOT-T0001016.bin

  flash:/CMW710-SYSTEM-T0001016.bin

  flash:/CMW710-SYSTEM-T0001016H04.bin

Configuration files

The system does not save the commands used in the configuration procedures to a configuration file.

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become a Partner
  • Partner Resources
  • Partner Business Management
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网