Title | Size | Downloads |
---|---|---|
H3C NSQ1TGX4EA0 LPU Card Manual-6PW105-book.pdf | 871.95 KB |
- Table of Contents
- Related Documents
-
1 Card view
Figure 1 NSQ1TGX4EA0 LPU
2 Specifications
Figure 2 Front panel of the NSQ1TGX4EA0 LPU
(1) 10GBASE-R-XFP 10-GE port |
(2) Interface status LED |
(3) Ejector lever |
(4) Captive screw |
Table 1 Card specifications
Item |
Specification |
Dimensions (H × W × D) |
40 × 399 × 352 mm (1.57 × 15.71 × 13.86 in) |
Power consumption |
53 W to 80 W |
Weight |
2.93 kg (6.46 lb) |
Hot swapping |
Supported |
Connector type |
LC |
Interfaces |
4 10GBASE-R-XFP 10-GE ports |
Interface transmission rate |
10 Gbps |
Ambient temperature |
· Operating: 0°C to 45°C (32°F to 113°F) · Storage: –40°C to +70°C (–40°F to +158°F) |
Ambient humidity |
· Operating: 10%RH to 95%RH, noncondensing · Storage: 5%RH to 95%RH, noncondensing |
Compatible device models and slots |
· M9006 gateway (slot 2 to slot 5) · M9010 gateway (slot 0 to slot 3 and slot 6 to slot 9) · M9014 gateway (slot 0 to slot 5 and slot 8 to slot 13) · T9006 IPS (slot 2 to slot 5) · T9010 IPS (slot 0 to slot 3 and slot 6 to slot 9) · T9014 IPS (slot 0 to slot 5 and slot 8 to slot 13) |
|
NOTE: 10GBASE-R-XFP 10-GE ports can operate only in 10G forced full-duplex mode. |
For supported XFP modules, see the following table.
Table 2 Specifications of XFP modules
XFP module |
Central wavelength |
Connector type |
Cable specifications |
Maximum transmission distance |
XFP-SX-MM850 |
850 nm |
LC |
50/125 μm multi-mode optical fiber |
300 m (984 ft) |
XFP-LX-SM1310 |
1310 nm |
LC |
9/125 μm single-mode optical fiber |
10 km (6 miles) |
XFP-LH40-SM1550 |
1550 nm |
LC |
9/125 μm single-mode optical fiber |
40 km (25 miles) |
XFP-LH80-SM1550 |
1550 nm |
LC |
9/125 μm single-mode optical fiber |
80 km (50 miles) |
3 LEDs
The NSQ1TGX4EA0 LPU provides LEDs to show the operating status of the interfaces.
Table 3 LED description
XFP port LED status (LINK) |
XFP port LED status (ACT) |
Description |
On |
Flashing |
A link is present on the XFP port, and the XFP port is sending or receiving data. |
On |
Off |
A link is present on the XFP port, but the XFP port is not sending or receiving data. |
Off |
Off |
No link is present on the XFP port. |
4 Installing and removing the NSQ1TGX4EA0 LPU
|
CAUTION: · Wear a well-grounded ESD-preventive wrist before you install or remove the LPU. · Do not touch the surface-mounted components directly with your hands when you install or remove the LPU. |
4.1 Installing the NSQ1TGX4EA0 LPU
1. Face the front panel of the device.
2. Identify the slot to install the LPU, and remove the filler panel from the slot.
This manual uses slot 3 as an example.
3. Place the LPU horizontally with the surface-mounted components facing up. Pull outward the ejector levers and gently push the LPU in along the slot guide rails until the LPU is in close contact with the backplane. (See callout 1 in Figure 3 .)
4. Push the ejector levers inward. (See callout 2 in Figure 3 .)
5. Tighten the captive screws with a Phillips screwdriver to secure the LPU in the slot. (See callout 3 in Figure 3 .)
Figure 3 Installing an NSQ1TGX4EA0 LPU
(1) Gently push the LPU in along the slot guide rails until the LPU is in close contact with the backplane. |
|
(2) Push the ejector levers inward. |
(3) Tighten the captive screws with a Phillips screwdriver. |
4.2 Removing the NSQ1TGX4EA0 LPU
1. Use a Phillips screwdriver to loosen the captive screws at both sides of the LPU until all pressure is released.
2. Pull the ejector levers at both sides of the LPU outward, and pull the LPU along the guide rails until it completely comes out of the backplane.
3. Place the LPU on an anti-static workbench with the surface-mounted components up, or put it in an anti-static bag.
4. If no new LPU is to be installed, install a filler panel to prevent dust and ensure good ventilation in the device.
5 Obtaining documentation
To access the most up-to-date H3C product documentation on the H3C website at www.h3c.com.hk:
1. Go to http://www.h3c.com.hk/Technical_Documents.
2. Choose the desired product category and model.