H3C SR8800-X Routers 100G Ethernet Optical Interface Module Datasheet-5W103

HomeSupportRoutersH3C SR8800-X Router SeriesProduct LiteratureCard DatasheetsH3C SR8800-X Routers 100G Ethernet Optical Interface Module Datasheet-5W103
Download Book

 

H3C SR8800-X Router Series

100G Ethernet Optical Interface Module Datasheet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Copyright © 2015 to 2022 New H3C Technologies Co., Ltd. All rights reserved.

No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of New H3C Technologies Co., Ltd.

Except for the trademarks of New H3C Technologies Co., Ltd., any trademarks that may be mentioned in this document are the property of their respective owners.

The information in this document is subject to change without notice.



Overview

The following 100G Ethernet optical interface modules are available for the SR8800-X routers.

Table 1 100G Ethernet optical interface modules available for the routers

Module model

Description

SPC-CP1LAX

1-port 100GBASE Ethernet optical interface module (CFP, LC) (A Type), not supported on the SR8800-X-S routers

SPC-CP1LC

1-port 100GBASE Ethernet optical interface module (CFP, LC) (C Type), supported only on the SR8800-X-S routers

SPC-CP1LCX

1-port 100GBASE Ethernet optical interface module (CFP, LC) (C Type), not supported on the SR8800-X-S routers

SPC-CP2LA

2-port 100GBASE Ethernet optical interface module (CFP, LC) (A Type)

SPC-CP2LB

2-port 100GBASE Ethernet optical interface module (CFP, LC) (B Type)

 

 

NOTE:

For compatibility between 100G Ethernet optical interface modules and switching fabric modules, see Appendix B FRUs and compatibility matrixes in H3C SR8800-X Routers Installation Guide.

 

Key features

High-speed access rate

The interface modules use 100GE CFP transceiver modules to provide an access rate of 100 Gbps per port, meeting data rate requirements for data centers.

High performance and scalability

With high-speed CPUs, the interface modules greatly improve the service processing capability and provide independent OAM engine for link status monitoring.

Environment-friendly design

The interface modules are compliant with the Restriction of Hazardous Substances (RoHS) standard.

Hot swapping

The interface modules are hot swappable. Installing and removing such a module on an operating router does not affect ongoing services on other modules. The management system monitors the module in real time and implements automated configuration for the module to ensure service continuity.

Specifications

The figures in this section are for illustration only.

SPC-CP1LAX/SPC-CP1LC/SPC-CP1LCX

The SPC-CP1LAX, SPC-CP1LC, and SPC-CP1LCX have the same appearance. This section uses the SPC-CP1LCX as an example.

Figure 1 SPC-CP1LCX

SPC-CP1LCX副本.gif

 

Front panel

Figure 2 SPC-CP1LCX front panel

(1) 100GBASE-R-CFP fiber port

(2) CFP port status LED

 

Technical specifications

Item

Specifications

Dimensions (H × W × D)

40 × 399 × 352 mm (1.57 ×15.7 × 13.86 in)

Power consumption

·     SPC-CP1LAX: 103 W to 135 W

·     SPC-CP1LC: 85 W to 120 W

·     SPC-CP1LCX: 115 W to 173 W

Ports

1

Connector type

LC

Port speed

100 Gbps

Net weight

·     SPC-CP1LAX/SPC-CP1LCX: 3.5 kg (7.72 lb)

·     SPC-CP1LC: 3.4 kg (7.50 lb)

System software version

·     SPC-CP1LAX/SPC-CP1LCX: 7133 or later

·     SPC-CP1LC: 7140P51 or later

 

SPC-CP2LA/SPC-CP2LB

The SPC-CP2LA and SPC-CP2LB have the same appearance. This section uses the SPC-CP2LA as an example.

Figure 3 SPC-CP2LA

SPC-CP2LA副本.gif

 

Front panel

Figure 4 SPC-CP2LA front panel

(1) 100GBASE-R-CFP fiber ports (2 in total)

(2) CFP port status LED

 

Technical specifications

Item

Specifications

Dimensions (H × W × D)

40 × 399 ×352 mm (1.57 ×15.7 × 13.86 in)

Power consumption

·     SPC-CP2LA: 144 W to 197 W

·     SPC-CP2LB: 150 W to 197 W

Ports

2

Connector type

LC

Port speed

100 Gbps

Net weight

4.06 kg (8.95 lb)

System software version

7133 or later

 

 

NOTE:

·     The SR8803-X-S that is installed with an MPU SR07SRPUC1 and the SR8802-X-S do not support the SPC-CP2LA or SPC-CP2LB.

·     For the SR8810-X-S, you must install the SPC-CP2LA and SPC-CP2LB in slot 0, slot 4, or slot 7.

 

LEDs

Table 2 CFP port status LED description

Status

Description

Flashing

The port is receiving or transmitting data.

On

A link is present.

Off

No link is present.

 

Environment requirements

Make sure the ambient environment meets the following requirements:

·     Temperature and humidity requirements

Table 3 Temperature and humidity requirements

Item

Specifications

Operating temperature

0°C to 45°C (32°F to 113°F)

Storage temperature

–40°C to +70°C (–40°F to +158°F)

Operating humidity

10% RH to 95% RH, non-condensing

Storage humidity

5% RH to 95% RH, non-condensing

 

·     Dust protection requirements

Table 4 Dust concentration limits in the equipment room

Substance

Particle diameter

Concentration limit

Dust particles

≥ 0.5 µm

≤ 1.8 × 107 particles/m3

 

·     Corrosive gas protection requirements

Table 5 Corrosive gas concentration limits in the equipment room

Gas

Average concentration (mg/m3)

Maximum concentration (mg/m3)

SO2

0.3

1.0

H2S

0.1

0.5

Cl2

0.1

0.3

HCI

0.1

0.5

HF

0.01

0.03

NH3

1.0

3.0

O3

0.05

0.1

NOX

0.5

1.0

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Intelligent Storage
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
  • Technical Blogs
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网