H3C IT RACK Series Product Information for Ecodesign Requirements of (EU) 2019/424
Regulatory Reference: COMMISSION REGULATION (EU) 2019/424, implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to Ecodesign requirements for servers and online data storage products.
Product Type |
Server |
Manufacturer |
New H3C Technologies Co., Ltd |
Trade |
H3C |
Address |
466 Changhe Road, Binjiang, 310052 Hangzhou, PEOPLE'S REPUBLIC OF CHINA |
Product Model |
H3C UniServer R4900 G3 |
Year of Manufacture |
2017 |
Idle State Power (W) and Active state efficiency
The test for Idle State power and Active State Efficiency is based on ETSI EN 303 470 V1.1.1 (2019-03)- Environmental Engineering (EE); Energy Efficiency measurement methodology and metrics for servers.
Configuration |
Idle State Power (W) |
Active state efficiency |
Low-end performance configuration |
180.2 |
17.9 |
High-end performance configuration |
200.2 |
38.5 |
Note: SERT Active State Efficiency must be higher to pass to table 5 of the Regulation. SERT Idle State Power must be lower than the calculated limit to pass- described in Annex II 2.1 of the Regulation.
Components List for additional idle power allowances
System characteristics |
Quantity |
Additional Idle Power Allowances |
CPU Performance |
2 |
18.9 |
Additional PSU |
0 |
0 |
HDD or SSD |
3 |
15 |
Additional Memory (GB) |
764 |
137.52 |
Additional buffered DDR Channel |
16 |
64 |
Additional I/O devices |
0 |
0 |
Total additional idle power allowances |
/ |
235.42 |
Maximum Power (W)
Configuration |
Maximum Power |
Low-end performance configuration |
268.5 |
High-end performance configuration |
273.4 |
Operating Condition Class
|
Dry bulb temp °C |
Humidity range, non-condensing |
|
|
||
Operating Condition Class |
Allowable Range |
Recommended Range |
Allowable Range |
Recommended Range |
Max Dew Point (°C) |
Maximum rate of Change (°C/hr) |
A4 |
5-45 |
18-27 |
-12 °C DP and 8 % RH to 24 °C DP and 90 % RH |
-9 °C DP to 15 °C DP and 60 % RH |
24 |
5/20 |
Idle State Power at the higher boundary temperature of the declared operating condition class
Configuration |
Idle State Power |
Low-end performance configuration |
268.5 |
High-end performance configuration |
273.4 |
Secure data deletion functionality
Instruction on how to use |
Copy the script and run it in the OS |
Used Techniques |
All data covered in the whole disk |
Supported standards |
DoD 5220.22-M |
List of all model configurations
Computing |
2 ×2nd Generation Intel Xeon Scalable Processors (CLX&CLX-R) (Up to 28 cores and maximum 205 W power consumption) |
Memory |
24 × DDR4 DIMMs with maximum 3.0 TB Capacity (Up to 2933 MT/s data transfer rate and support of both RDIMM and LRDIMM) (Up to 12 Intel ® Optane™ DC Persistent Memory Module.(DCPMM) |
Storage |
Front 12LFF + rear 4LFF and 4SFF or front 25SFF + rear 2LFF and 4SFF(supports SAS/SATA HDD/SSD, front and inside NVMe drives, and up to 24 front NVMe drives) 480 GB SATA M.2 SSDs (Optional) SD cards |
GPU |
3 × dual-slot wide GPU modules or 8 × single-slot wide GPU modules |
Note: The configurations of server product family are end-user configurable / selectable, the detail can be found at http://www.h3c.com
The Concentration of Cobalt and Neodymium
Item |
Description |
Cobalt in battery |
Less than 5g |
Neodymium in HDD |
between 5 g and 25 g |
Disassembly Operations
Operation Type |
Description |
|
Data Storage Device |
Release buckle |
|
Memory |
Release buckle |
|
CPU |
Remove Screw |
|
Motherboard |
Remove Screw |
|
Expansion/Graphic Card |
Remove Screw |
|
PSU |
Release buckle |
|
Chassis |
Release buckle |
|
Batteries |
Release buckle |
|
Fastening technique type |
Quantity |
Required Tool |
Trox Screw |
26 |
Trox Screw Driver T15 |
Trox Screw |
13 |
Trox Screw Driver T10 |
Pan Head Screw |
3 |
Pan Head Screw Driver Medium |
Philps Screw |
4 |
Philps Screw Driver #2 |
Buckle |
60 |
/ |