H3C SecPath L5000-AD5X0-G Application Delivery Security Gateway Series
Hardware Information and Specifications
Copyright © 2025 New H3C Technologies Co., Ltd. All rights reserved.
No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of New H3C Technologies Co., Ltd.
Except for the trademarks of New H3C Technologies Co., Ltd., any trademarks that may be mentioned in this document are the property of their respective owners.
The information in this document is subject to change without notice.
1 Chassis views and technical specifications
L5000-AD520-G/L5000-AD540-G/L5000-AD560-G
Temperature and humidity requirements
2 FRUs and compatibility matrixes
High-density interface modules
High-density interface module compatibility matrixes
High-density interface module views
Power supply compatibility matrixes
Fan tray compatibility matrixes
Transceiver modules available for the high-density interface modules
Transceiver modules available for the GE fiber ports
Transceiver modules available for the 10GE fiber ports
Transceiver modules available for the 100GE fiber ports
1 Chassis views and technical specifications
Chassis views
IMPORTANT: · To install a USB drive on the L5000-AD520-G, L5000-AD540-G, or L5000-AD560-G, make sure the USB drive has a minimum of 32 GB storage space. · After you use the display device manuinfo command on the L5000-AD560-G to view its electrical label information, the output shows that each fan tray has two electrical labels. For example, fan tray 0 has the Fan 0 and Fan 1 electrical labels. · The actual marks on the chassis might be slightly different from those in the figures. |
|
NOTE: The default Web interface login information of the device is as follows: · Username—admin. · Password—admin. · IP address of the management Ethernet port—192.168.0.1/24. For detailed configuration, see the device nameplate. |
L5000-AD520-G/L5000-AD540-G/L5000-AD560-G
An L5000-AD520-G, L5000-AD540-G, or L5000-AD560-G provides the following ports and slots on the front panel:
· Four interface module slots.
· Two USB ports.
· One management Ethernet port.
· One console port.
· One reset button.
· Two drive slots.
Figure1-1 Front view
(1) Interface module slot SUBSLOT 4 |
(2) Interface module slot SUBSLOT 3 |
(3) Interface module slot SUBSLOT 2 |
(4) Interface module slot SUBSLOT 1 |
(5) LEDs |
(6) Drive slots |
(7) USB port |
(8) Management Ethernet port (MGMT) |
(9) Console port |
(10) RESET button (for device reboot only, and does not restore the factory default) |
Figure1-2 Rear view
(1) Power supply slot PWR0 |
(2) Power supply slot PWR1 |
(3) Fan tray slot |
(4) Interface module slot SUBSLOT 6 (not supported) |
(5) Interface module slot SUBSLOT 5 (not supported) |
(6) Grounding screw |
Technical specifications
Technical specifications
Table1-1 Technical specifications
Model |
Dimensions (H × W × D) |
Memory type and capacity |
Weight |
Static power consumption |
Dynamic power consumption |
L5000-AD520-G |
44.0 × 440 × 560 mm (1.73 × 17.32 × 22.05 in) |
32GB DDR4 |
7.5 kg (16.53 lb) |
32.83 W |
110.86 W |
L5000-AD540-G |
44.0 × 440 × 560 mm (1.73 × 17.32 × 22.05 in) |
64GB DDR4 |
7.5 kg (16.53 lb) |
32.83 W |
110.86 W |
L5000-AD560-G |
44.0 × 440 × 560 mm (1.73 × 17.32 × 22.05 in) |
64GB DDR4 |
7.8 kg (17.20 lb) |
79.66 W |
193.55 W |
Temperature and humidity requirements
Table1-2 Indoor environment requirements
Item |
Requirement |
Temperature |
· Operating: ¡ Without drives: 0°C to 45°C (32°F to 113°F) ¡ With drives: 5°C to 40°C (41°F to 104°F) · Storage: –40°C to +70°C (–40°F to +158°F) |
Humidity |
· Operating: ¡ Without drives: 5% RH to 95 RH, noncondensing ¡ With drives: 10% RH to 90 RH, noncondensing · Storage: 5% RH to 95 RH, noncondensing |
Cooling system
The device uses front-to-rear airflow for heat dissipation. Plan the installation site for the device based on its airflow direction for adequate ventilation. Make sure the following requirements are met:
· When you install the device in a standard 19-inch rack, follow these guidelines:
¡ Ensure a minimum clearance of 100 mm (3.94 in) around the air inlet and outlet vents of the chassis.
¡ Ensure a distance of 1U (44.45 mm, or 1.75 in) between the chassis and other devices.
· The installation site has a good cooling system.
2 FRUs and compatibility matrixes
Installation accessories
Table2-1 Installation accessories
Accessory |
Accessory name |
Applicable device models |
4-hole mounting bracket |
All models |
|
Rear mounting bracket (including an M4 shoulder screw) |
All models |
|
M6 rack screw |
All models |
|
Cage nut |
All models |
|
M4 mounting bracket screw |
All models |
|
Grounding cable |
All models |
High-density interface modules
CAUTION: · Only E9900P19 and later versions support high-density interface modules. · Do not hot swap high-density interface modules. |
High-density interface module compatibility matrixes
Table2-2 High-density interface module compatibility matrix
Device model |
Available high-density interface modules |
L5000-AD520-G/L5000-AD540-G |
NS-FPIM-CQG4TG16GT16AL |
L5000-AD560-G |
NS-FPIM-CQG4TG16GT16BL |
High-density interface module views
The NS-FPIM-CQG4TG16GT16AL and NS-FPIM-CQG4TG16GT16BL high-density interface modules are similar in appearance. This section uses the NS-FPIM-CQG4TG16GT16AL as an example.
A high-density interface module provides sixteen 10/100/1000BASE-T copper Ethernet ports, sixteen 10GBASE-R fiber Ethernet ports (including two HA ports), and four 100GBASE-R fiber Ethernet ports.
Figure2-1 Front view
(1) 10/100/1000BASE-T copper Ethernet ports |
(2) 10GBASE-R fiber Ethernet ports |
(3) 100GBASE-R fiber Ethernet ports |
(4) 10GBASE-R fiber Ethernet ports |
(5) HA ports (10GBASE-R fiber Ethernet ports) |
(6) 100GBASE-R fiber Ethernet ports |
(7) Captive screw |
(8) LED (SYS) |
|
NOTE: A high-density interface module occupies subslots 1 to 4. To install a high-density interface module, first remove the filler panels from the subslots. Then, loosen the three slide rail mounting screws and remove the three slide rails from the chassis. Finally, insert the high-density interface module and fasten the captive screws on it. |
Figure2-2 Chassis front view
(1) Slide rail mounting screws |
(2) Slide rails |
Table2-3 High-density interface module specifications
Item |
Specification |
Model |
· NS-FPIM-CQG4TG16GT16AL · NS-FPIM-CQG4TG16GT16BL |
Dimensions (H × W × D) |
40.0 × 356 × 224 mm (1.57 × 14.02 × 8.82 in) |
Weight |
1.65 kg (3.64 lb) |
Static power consumption |
58.65 W |
Maximum power consumption |
136.92 W |
Interface modules
Interface module views
NS-HPIM-TG4B
The NS-HPIM-TG4B interface module provides four 10GBASE-R-SFP+ fiber Ethernet ports.
Figure2-3 Front view
(1) Captive screw |
(2) 10GBASE-R SFP+ fiber Ethernet ports |
(3) LED (READY) |
Table2-4 NS-HPIM-TG4B specifications
Item |
Specification |
Model |
NS-HPIM-TG4B |
Dimensions (H × W × D) |
40 × 88 × 224 mm (1.57 × 3.46 × 8.82 in) |
Weight |
0.33 kg (0.73 lb) |
Static power consumption |
12.21 W |
Maximum power consumption |
18.45 W |
IMPORTANT: The 10GE fiber ports on the interface module do not support 1000 Mbps autosensing. |
NS-HPIM-GP8B
The NS-HPIM-GP8B interface module provides eight 1000BASE-X-SFP fiber Ethernet ports.
Figure2-4 Front view
(1) Captive screw |
(2) 1000BASE-X-SFP fiber Ethernet ports |
(3) LED (READY) |
Table2-5 NS-HPIM-GP8B specifications
Item |
Specification |
Model |
NS-HPIM-GP8B |
Dimensions (H × W × D) |
40 × 88 × 224 mm (1.57 × 3.46 × 8.82 in) |
Weight |
0.38 kg (0.84 lb) |
Static power consumption |
3.91 W |
Maximum power consumption |
15.59 W |
NS-HPIM-GT8B
The NS-HPIM-GT8B interface module provides eight 10/100/1000BASE-T copper Ethernet ports.
Figure2-5 Front view
(1) Captive screw |
(2) 10/100/1000BASE-T copper Ethernet ports |
(3) LED (READY) |
Table2-6 NS-HPIM-GT8B specifications
Item |
Specification |
Model |
NS-HPIM-GT8B |
Dimensions (H × W × D) |
40 × 88 × 224 mm (1.57 × 3.46 × 8.82 in) |
Weight |
0.43 kg (0.95 lb) |
Static power consumption |
5.77 W |
Maximum power consumption |
9.73 W |
Power supplies
The device comes with power supply slot PWR0 installed with a filler panel and power supply slot PWR1 empty.
You can install one power supply, or two power supplies in 1+1 redundancy for the device. To install two power supplies for the device, make sure they are the same model.
Power supply compatibility matrixes
Table2-7 Power supply compatibility matrix
Device model |
Available power supplies |
L5000-AD520-G/L5000-AD540-G |
· PSR250-12A1 · PSR450-12A1 · PSR450-12D · PSR450-12AHD |
L5000-AD560-G |
· PSR650B-12A1 · PSR650B-12D1 · PSR650B-12AHD-F |
Power supply views
PSR250-12A1 AC power supply
The PSR250-12A1 power supply with a product code of PSR250-12A1 provides a maximum output power of 250 W.
Figure2-6 Front view
(1) Latch |
(2) Status LED |
(3) Handle |
(4) Power input receptacle |
Table2-8 PSR250-12A1 AC power supply specifications
Item |
Specification |
Model |
PSR250-12A1 |
Rated input voltage |
100 VAC to 240 VAC @ 50 or 60 Hz |
Max input current |
5 A |
Max output power |
250 W |
PSR450-12A1 AC power supply
The PSR450-12A1 power supply provides a rated output power of 450 W.
Figure2-7 Front view
(1) Latch |
(2) Status LED |
(3) Handle |
(4) Power input receptacle |
Table2-9 PSR450-12A1 AC power supply specifications
Item |
Specification |
Model |
PSR450-12A1 |
Rated input voltage |
100 VAC to 240 VAC @ 50 or 60 Hz |
Max input current |
7 A |
Max output power |
450 W |
PSR650B-12A1 AC power supply
The PSR650B-12A1 power supply with a product code of PSR650B-12A1 provides a maximum output power of 650 W.
Figure2-8 Front view
(1) Latch |
(2) Handle |
(3) Power input receptacle |
Table2-10 PSR650B-12A1 AC power supply specifications
Item |
Specification |
Model |
PSR650B-12A1 |
Rated input voltage |
100 VAC to 240 VAC @ 50 or 60 Hz |
Max input current |
10 A to 5 A |
Max output power |
650 W |
PSR450-12D DC power supply
The PSR450-12D power supply provides a rated output power of 450 W.
Figure2-9 Front view
(1) Latch |
(2) Status LED |
(3) Handle |
(4) Power input receptacle |
Table2-11 PSR450-12D DC power supply specifications
Item |
Specification |
Model |
PSR450-12D |
Rated input voltage |
–48 VDC to –60 VDC |
Max input current |
15 A |
Max output power |
450 W |
PSR650B-12D1 DC power supply
The PSR650B-12D1 power supply with a product code of PSR650B-12D1 provides a maximum output power of 650 W.
Figure2-10 Front view
(1) Latch |
(2) Handle |
(3) Power input receptacle |
Table2-12 PSR650B-12D1 DC power supply specifications
Item |
Specification |
Model |
PSR650B-12D1 |
Rated input voltage |
–48 VDC to –60 VDC |
Max input current |
22 A to 12 A |
Max output power |
650 W |
PSR450-12AHD HVDC power supply
The PSR450-12AHD power supply provides a maximum output power of 450 W.
Figure2-11 PSR450-12AHD power supply view
(1) Latch |
(2) Status LED |
(3) Handle |
(4) Power input receptacle |
Table2-13 PSR450-12AHD HVDC power supply specifications
Item |
Specification |
Model |
PSR450-12AHD |
Rated input voltage |
· AC input: 100 VAC to 240 VAC @ 50 or 60 Hz · HVDC input: 240 VDC to 380 VDC |
Max input current |
· AC input: 7 A · HVDC input: 3.5 A |
Max output power |
450 W |
PSR650B-12AHD-F HVDC power supply
The PSR650B-12AHD-F power supply with a product code of PSR650B-12AHD-F provides a maximum output power of 650 W.
Figure2-12 PSR650B-12AHD-F HVDC power supply view
(1) Latch |
(2) Status LED |
(3) Power input receptacle |
(4) Handle |
Table2-14 PSR650B-12AHD-F HVDC power supply specifications
Item |
Specification |
Model |
PSR650B-12AHD-F |
Rated input voltage |
· AC input: 100 VAC to 240 VAC @ 50 or 60 Hz · HVDC input: 240 VDC to 380 VDC |
Max input current |
52.9 A (12 V) / 3 A (5 V) |
Max output power |
650 W |
Fan trays
Fan tray compatibility matrixes
Table2-15 Fan tray compatibility matrix
Device model |
Available fan trays |
L5000-AD520-G/L5000-AD540-G |
LSPM1FANSB-SN |
L5000-AD560-G |
FAN-40B-1-A |
Fan tray views
LSPM1FANSB-SN
The L5000-AD520-G or L5000-AD540-G provides four fan tray slots FAN0 to FAN3.
The LSPM1FANSB-SN fan tray is available for the L5000-AD520-G and L5000-AD540-G, which draws air from the port side to the power supply side.
Figure2-13 Fan tray view
(1) Handle |
(2) Alarm LED |
Table2-16 Fan tray specifications
Item |
Specification |
Dimensions (H × W × D), including the handles |
40.6 × 40.0 × 105 mm (1.60 × 1.57 × 4.13 in) |
Airflow direction |
Draws air from the port side to the power supply side |
Maximum air flow rate |
20 CFM (0.57 m3/min) |
Max power consumption |
9.8 W |
Operating voltage |
12 V |
FAN-40B-1-A
The L5000-AD560-G provides four fan tray slots FAN0 to FAN3.
The FAN-40B-1-A fan tray is available for the L5000-AD560-G, which draws air from the port side to the power supply side.
Figure2-14 Fan tray view
(1) Handle |
(2) Alarm LED |
Table2-17 Fan tray specifications
Item |
Specification |
Dimensions (H × W × D), excluding the handles |
40.6 × 40.0 × 117 mm (1.60 × 1.57 × 4.61 in) |
Airflow direction |
Draws air from the port side to the power supply side |
Maximum air flow rate |
26 CFM (0.74 m3/min) |
Max power consumption |
27.72 W |
Operating voltage |
12 V |
Drives
Drive specifications
Table2-18 Drive specifications
Drive model |
Dimensions (H × W × D) |
Weight |
Capacity |
Power consumption |
NS-SSD-480G-SATA-M.2 |
12.1 × 28 × 100 mm (0.48 × 1.10 × 3.94 in) |
0.05 kg (0.11 lb) |
480 GB |
4.5 W |
3 Ports
Chassis ports
Console port
Table3-1 Console port specifications
Item |
Specification |
Connector type |
RJ-45 |
Compliant standard |
RS-232 |
Transmission baud rate |
9600 bps (default) to 115200 bps |
Cable type |
Common asynchronous serial port cable |
Transmission distance |
≤ 15 m (49.21 ft) |
Supported services |
· Provides connection to an ASCII terminal. · Connects to the serial port on a local PC running a terminal emulation program. · Supports command line interface (CLI) |
Copper transceiver modules
Table3-2 GE SFP copper transceiver module specifications
Model |
Transmission distance |
Transmission rate |
Connector type |
SFP-GE-T |
100 m (328.08 ft) |
1250 Mbps |
RJ-45 |
SFP-GE-T-D |
100 m (328.08 ft) |
1250 Mbps |
RJ-45 |
Table3-3 SFP+ copper transceiver module specifications
Model |
Transmission distance |
Transmission rate |
Cable type |
Cable specifications |
Connector type |
SFP-10GE-T |
30 m (98.43 ft) |
10 Gbps |
STP |
Category 6e shielded twisted pair/category 7 twisted pair cable |
RJ-45 |
100 m (328.08 ft) |
1000/100 Mbps |
UTP/STP |
Category 5e twisted pair cable |
GE fiber port
Table3-4 GE fiber port specifications
Item |
Specification |
Connector type |
LC |
Transceiver module type |
SFP |
Compliant standard |
1000BASE-X |
Transmission baud rate |
1000 Mbps |
Operating mode |
Full-duplex |
Table3-5 GE SFP optical transceiver modules available for the 1000BASE-X SFP ports
GE SFP transceiver module |
Central wavelength (nm) |
Connector type |
Cable/Fiber type and diameter (µm) |
Max transmission distance |
SFP-GE-SX-MM850-A |
850 |
LC |
50/125, MMF |
0.55 km (0.34 miles) |
SFP-GE-SX-MM850-D |
850 |
LC |
50/125, MMF |
0.55 km (0.34 miles) |
SFP-GE-LX-SM1310-A |
1310 |
LC |
9/125, SMF |
10 km (6.21 miles) |
SFP-GE-LX-SM1310-D |
1310 |
LC |
9/125, SMF |
10 km (6.21 miles) |
SFP-GE-LH40-SM1310 |
1310 |
LC |
9/125, SMF |
40 km (24.86 miles) |
SFP-GE-LH40-SM1310-D |
1310 |
LC |
9/125, SMF |
40 km (24.86 miles) |
SFP-GE-LH40-SM1550 |
1550 |
LC |
9/125, SMF |
40 km (24.86 miles) |
SFP-GE-LH80-SM1550 |
1550 |
LC |
9/125, SMF |
80 km (49.71 miles) |
SFP-GE-LH80-SM1550-D |
1550 |
LC |
9/125, SMF |
80 km (49.71 miles) |
SFP-GE-LH100-SM1550 |
1550 |
LC |
9/125, SMF |
100 km (62.14 miles) |
10GE fiber port
Table3-6 10GE fiber port specifications
Item |
Specification |
Connector type |
LC |
Transceiver module type |
SFP+ |
Compliant standard |
10GBASE-R |
Transmission baud rate |
LAN PHY mode: 10.3125 Gbps |
Table3-7 10GE SFP+ transceiver modules available for the SFP+ fiber ports
10GE SFP+ transceiver module model |
Central wavelength (nm) |
Connector type |
Cable/Fiber type and diameter (µm) |
Max transmission distance |
SFP-XG-SX-MM850-A |
850 |
LC |
50/125, MMF |
400 m (1312.34 ft) |
62.5/125, MMF |
33 m (108.27 ft) |
|||
SFP-XG-SX-MM850-D |
850 |
LC |
50/125, MMF |
400 m (1312.34 ft) |
62.5/125, MMF |
33 m (108.27 ft) |
|||
SFP-XG-SX-MM850-E |
850 |
LC |
50/125, MMF |
400 m (1312.34 ft) |
62.5/125, MMF |
33 m (108.27 ft) |
|||
SFP-XG-LX-SM1310 |
1310 |
LC |
9/125, SMF |
10 km (6.21 miles) |
SFP-XG-LX-SM1310-D |
1310 |
LC |
9/125, SMF |
10 km (6.21 miles) |
SFP-XG-LX-SM1310-E |
1310 |
LC |
9/125, SMF |
10 km (6.21 miles) |
SFP-XG-LH40-SM1550 |
1550 |
LC |
9/125, SMF |
40 km (24.86 miles) |
SFP-XG-LH40-SM1550-D |
1550 |
LC |
9/125, SMF |
40 km (24.86 miles) |
SFP-XG-LH80-SM1550 |
1550 |
LC |
9/125, SMF |
80 km (49.71 miles) |
SFP-XG-LH80-SM1550-D |
1550 |
LC |
9/125, SMF |
80 km (49.71 miles) |
Transceiver modules available for the high-density interface modules
Copper transceiver modules
Table3-8 GE SFP copper transceiver module specifications
Model |
Transmission distance |
Transmission rate |
Connector type |
SFP-GE-T |
100 m (328.08 ft) |
1250 Mbps |
RJ-45 |
SFP-GE-T-D |
100 m (328.08 ft) |
1250 Mbps |
RJ-45 |
Transceiver modules available for the GE fiber ports
Table3-9 1000BASE-X SFP optical transceiver module specifications
Model |
Central wavelength (nm) |
Connector type |
Cable/Fiber type and diameter (µm) |
Max transmission distance |
SFP-GE-SX-MM850-A |
850 |
LC |
50/125, MMF |
0.55 km (0.34 miles) |
SFP-GE-SX-MM850-D |
850 |
LC |
50/125, MMF |
0.55 km (0.34 miles) |
SFP-GE-LX-SM1310-A |
1310 |
LC |
9/125, SMF |
10 km (6.21 miles) |
SFP-GE-LX-SM1310-D |
1310 |
LC |
9/125, SMF |
10 km (6.21 miles) |
SFP-GE-LH40-SM1310 |
1310 |
LC |
9/125, SMF |
40 km (24.86 miles) |
SFP-GE-LH40-SM1310-D |
1310 |
LC |
9/125, SMF |
40 km (24.86 miles) |
SFP-GE-LH40-SM1550 |
1550 |
LC |
9/125, SMF |
40 km (24.86 miles) |
SFP-GE-LH80-SM1550 |
1550 |
LC |
9/125, SMF |
80 km (49.71 miles) |
SFP-GE-LH100-SM1550 |
1550 |
LC |
9/125, SMF |
100 km (62.14 miles) |
Transceiver modules available for the 10GE fiber ports
Table3-10 SFP+ optical transceiver module specifications
Model |
Central wavelength (nm) |
Connector type |
Cable/Fiber type and diameter (µm) |
Max transmission distance |
SFP-XG-SX-MM850-A |
850 |
LC |
50/125, MMF |
400 m (1312.34 ft) |
62.5/125, MMF |
33 m (108.27 ft) |
|||
SFP-XG-SX-MM850-D |
850 |
LC |
50/125, MMF |
400 m (1312.34 ft) |
62.5/125, MMF |
33 m (108.27 ft) |
|||
SFP-XG-SX-MM850-E |
850 |
LC |
50/125, MMF |
400 m (1312.34 ft) |
62.5/125, MMF |
33 m (108.27 ft) |
|||
SFP-XG-LX-SM1310-D |
1310 |
LC |
9/125, SMF |
10 km (6.21 miles) |
SFP-XG-LX-SM1310-E |
1310 |
LC |
9/125, SMF |
10 km (6.21 miles) |
SFP-XG-LH40-SM1550 |
1550 |
LC |
9/125, SMF |
40 km (24.86 miles) |
SFP-XG-LH80-SM1550 |
1550 |
LC |
9/125, SMF |
80 km (49.71 miles) |
SFP-XG-LH80-SM1550-D |
1550 |
LC |
9/125, SMF |
80 km (49.71 miles) |
Transceiver modules available for the 100GE fiber ports
Table3-11 Specifications of QSFP28 optical transceiver modules with MPO connectors
Model |
Central wavelength (nm) |
Fiber mode and diameter (µm) |
Modal bandwidth (MHz*km) |
Transmission distance |
Transmission rate |
Optical parameters (dBm) |
|
Transmit power |
Receive power |
||||||
QSFP-100G-SR4-MM850 |
850 |
50/125, MMF |
2000 |
70 m (229.66 ft) |
100 Gbps |
–8.4 to +2.4 |
–10.3 to +2.4 |
4700 |
100 m (328.08 ft) |
||||||
QSFP-40G-SR4-MM850 |
850 |
50/125, MMF |
2000 |
100 m (328.08 ft) |
40 Gbps |
–7.6 to 0 |
–9.5 to +2.4 |
4700 |
150 m (492.13 ft) |
||||||
QSFP-40G-CSR4-MM850 |
850 |
50/125, MMF |
2000 |
300 m (984.25 ft) |
40 Gbps |
–7.6 to 0 |
–9.9 to +2.4 |
Table3-12 Specifications of QSFP28 optical transceiver modules with LC connectors
Model |
Central wavelength (nm) |
Fiber mode and diameter (µm) |
Modal bandwidth (MHz*km) |
Transmission distance |
Optical parameters (dBm) |
|
Transmit power |
Receive power |
|||||
QSFP-100G-LR4L-WDM1300 |
Four lanes: · 1271 · 1291 · 1311 · 1331 |
9/125, SMF |
N/A |
2 km (1.24 miles) |
–6.5 to +2.5 |
–11.5 to +2.5 |
QSFP-100G-LR4-WDM1300 |
Four lanes: · 1295.56 · 1300.05 · 1304.58 · 1309.14 |
9/125, SMF |
N/A |
10 km (6.21 miles) |
–4.3 to +4.5 |
–10.6 to +4.5 |
QSFP-100G-ER4-WDM1300 |
Four lanes: · 1295.56 · 1300.05 · 1304.58 · 1309.14 |
9/125, SMF |
N/A |
40 km (24.86 miles) |
–2.9 to +2.9 |
–20.9 to –3.5 |
QSFP-40G-BIDI-SR-MM850 |
Two lanes: · 850 · 900 |
50/125, MMF |
2000 |
100 m (328.08 ft) |
–4 to +5 |
–6 to +5 |
4700 |
150 m (492.13 ft) |
|||||
QSFP-40G-LR4L-WDM1300 |
Four lanes: · 1271 · 1291 · 1311 · 1331 |
9/125, SMF |
N/A |
2 km (1.24 miles) |
–10 to +2.3 |
–11.5 to +2.3 |
QSFP-40G-LR4-WDM1300 |
Four lanes: · 1271 · 1291 · 1311 · 1331 |
9/125, SMF |
N/A |
10 km (6.21 miles) |
–7 to +2.3 |
–13.7 to +2.3 |
4 LEDs
LED |
Mark |
Status |
Description |
System status LED |
SYS |
Off |
The system has failed (excluding the resetting period). |
Flashing at 0.5 Hz |
The system is operating correctly. |
||
Flashing at 4 Hz |
The system is starting or loading software. |
||
Steady on |
The system has failed. |
||
Power supply LED |
PWR |
Steady green |
The power supply is operating correctly. |
Off |
The power supply is not present or no power is present. |
||
HA LED |
HA |
Steady green |
The device is the primary device in a stateful failover system or cluster. |
Steady red |
The stateful failover system or cluster has failed. |
||
Flashing at 0.5 Hz |
The device is the secondary device in a stateful failover system or cluster. |
||
Off |
The device is not in a stateful failover system or cluster. |
||
Cloud LED |
CLOUD |
Steady green |
The device has been connected to the cloud management platform. |
Off |
The device has not been connected to the cloud management platform. |
||
Flashing at 4 Hz |
The device is connecting to the cloud management platform and data is being received and sent. |
||
Fan tray status LED |
FAN |
Steady green |
All fan trays are operating correctly. |
Steady red |
A fan tray has failed or less than four fan trays are present. |
||
Copper management Ethernet port LED |
MGMT |
Steady green |
A link is being established on the port. |
Flashing green |
The port is sending or receiving data. |
5 Installing the device
This document covers the views and specifications of the device and removable components, slots, interface numbering, and LEDs. For more information about the installation method and procedure, see the installation guide for the product.
The 1U device can be installed in a 19-inch rack by using front and rear mounting brackets.
You can attach the rear mounting brackets to the rack with the wide flange inside or outside the rack. Table5-1 shows the distance between the front and rear rack posts when you attach rear mounting brackets to the rack.
Table5-1 Distance between the front and rear rack posts
Distance between the front and rear rack posts |
Installation method |
531 to 696 mm (20.91 to 27.40 in) |
With the wide flange inside the rack |
373 to 538 mm (14.69 to 21.18 in) |
With the wide flange outside the rack |