MSR36E-CMW910-R9141P16

Release time:2025-05-30
HomeSupportRoutersMSR3600 Series(Comware V9)Software DownloadMSR 3610E-X1[X1-DP]

H3C MSR1000_MSR26_MSR36_MSR56-CMW910-R9141P16 Release Notes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H3C_彩色.emf

 

Contents

Version information· 1

Version number· 1

Version history· 1

Hardware and software compatibility matrix· 2

Upgrading restrictions and guidelines· 5

Hardware feature updates· 5

CMW910-R9141P16· 5

CMW910-R9141P1504· 5

CMW910-R9141P1501· 5

CMW910-R9141P1202· 5

CMW910-R9141P07· 6

CMW910-R9119P17· 6

CMW910-R9119P16· 6

CMW910-R9119P15· 6

CMW910-R9119P12· 6

Software feature and command updates· 6

MIB updates· 6

Operation changes· 6

Restrictions and cautions· 7

Open problems and workarounds· 7

List of resolved problems· 7

Resolved problems in CMW910-R9141P16· 7

Resolved problems in CMW910-R9141P1504· 8

Resolved problems in CMW910-R9141P1501· 8

Resolved problems in CMW910-R9141P1202· 9

Resolved problems in CMW910-R9141P07· 11

Resolved problems in CMW910-R9119P17· 11

Resolved problems in CMW910-R9119P16· 13

Resolved problems in CMW910-R9119P15· 14

Resolved problems in CMW910-R9119P12· 16

Related documentation· 18

Documentation set 18

Obtaining documentation·· 18

Technical support 18

Appendix A Feature list 20

Hardware features· 20

Software features· 24

Appendix B Upgrading software· 28

Software types· 28

Upgrade methods· 29

Preparing for the upgrade· 29

Upgrading from the CLI 30

Saving the running configuration and verifying the storage space· 30

Downloading the image file to the router· 31

Specifying the startup image file· 32

Rebooting and completing the upgrade· 33

Upgrading from the BootWare menu·· 34

Accessing the BootWare menu·· 34

Using TFTP/FTP to upgrade software through an Ethernet port 36

Using XMODEM to upgrade software through the console port 38

Managing files from the BootWare menu·· 43

Displaying all files· 44

Changing the type of a system software image· 45

Deleting files· 45

Handling software upgrade failures· 46

Appendix C Handling console login password loss· 46

Disabling password recovery capability· 46

Handling console login password loss· 47

Examining the password recovery capability setting·· 48

Using the Skip Current System Configuration option·· 49

Using the Skip Authentication for Console Login option·· 50

Using the Restore to Factory Default Configuration option·· 51



This document describes the features, restrictions and guidelines, open problems, and workarounds for version R9141P16. Before you use this version in a live network, back up the configuration and test the version to avoid software upgrade affecting your live network. Use this document in conjunction with H3C MSR1000_MSR26_MSR36_MSR56-CMW910-R9141P16 Release Notes (Software Feature Changes) and the documents listed in "Related documentation."

Version information

Version number

H3C Comware Software, Version 9.1.063, Release 9141P16

Note: You can see the version number with the command display version in any view. Please see Note.

Version history

Table 1 Version history

Version number

Last version

Release date

Release type

Remarks

CMW910-R9141P16

CMW910-R9141P1504

2025-02-19

Release version

·     New feature.

·     Fixes bugs.

CMW910-R9141P1504

CMW910-R9141P1501

2025-01-03

Release version

·     New feature.

·     Modified feature.

·     Fixes bugs.

CMW910-R9141P1501

CMW910-R9141P1202

2024-11-14

Release version

·     New feature.

·     Modified feature.

·     Fixes bugs.

CMW710-R9119P17

CMW910-R9141P1202

CMW910-R9141P07

2024-08-21

Release version

Only support MSR5680-X3 series

·     New hardware feature

·        Bug fixed

CMW910-R9141P07

CMW910-E9141P06

2024-01-16

Release version

Only support MSR5680-X3 series

·        Bug fixed

CMW910-E9141P06

First release

2023-10-27

ESS version

Only support MSR5680-X3 series

·        First release

CMW710-R9119P17

CMW710-R9119P16

2023-08-22

Release version

·        Fixes bugs

CMW710-R9119P16

CMW710-R9119P15

2023-05-23

Release version

·        Fixes bugs

CMW710-R9119P15

CMW710-R9119P12

2023-02-23

Release version

·        Fixes bugs

CMW710-R9119P12

First release

2022-06-28

aRelease version

·        First release

 

Hardware and software compatibility matrix

 

CAUTION

CAUTION:

To avoid an upgrade failure, use Table 2 to verify the hardware and software compatibility before performing an upgrade.

 

Table 2 Hardware and software compatibility matrix

Item

Specifications

Product family

MSR1008

MSR2630E-X1

MSR3610E-X1/MSR3610E-X1-DP

MSR5680-X3MSU-400-G

MSR5680-X3MSU-100/MSU-200

Boot ROM version

MSR1008: 104 or higher

MSR2630E-X1/MSR3610E-X1/MSR3610E-X1-DP 1106 or higher

MSR5680-X3MSU-400-G):: 110 or higher

MSR5680-X3MSU-100/MSU-200):102 or higher

(Note: Perform the command display version command in any view to view the version information. Please see Note)

Host software

Hardware

software

MD5 Check Sum

MSR2630E-X1

MSR26E-CMW910-R9141P16.ipe

b34ae6250f2ce9266823a60e339b8d45

MSR3610E-X1/ MSR3610E-X1-DP

MSR36E-CMW910-R9141P16.ipe

a8fddc8434d65ed3a947c2ba18eff4e5

MSR1008

MSR1000-CMW910-R9141P16.ipe

57c5eb62cb60497b46d430e0edc72d49

 

MSR5680-X3MSU-100/MSU-200

MSR56X3MSU2XX-CMW910-R9141P16.ipe

343f17c795501d8e799f4bfbecc54f0f

 

MSR5680-X3MSU-400-G

MSR56X3MSU4XXG-CMW910-R9141P16.ipe

42b03b40406abac9bda0b710e4d04891

MC version

iMC FCAPS(E0709)

iMC AOM(E0706P01)

iMC ACLM (E0705P12)

iMC BIMS 7.3 (E0506H01)

iMC DM 7.3(E0705P12)

iMC EAD 7.3 (E0611P10)

iMC EIA 7.3 (E0611P13)

iMC EIA 7.3 (E0611P13)

iMC iCC 7.3(E0705P12)

iMC IVM 7.3 (E0506)

iMC MVM 7.3 (E0510)

iMC NTA 7.3 (E0707L06)

iMC PLAT 7.3 (E0705P12)

iMC QoSM 7.3 (E0505P01)

iMC SHM 7.3 (E0707L06)

UCenter E0707L06

iMC VLAN 7.3 (E0705P12)

iNode version

iNode PC 7.3 (E0585)

 

Please see the example below generated by the display version command:

<Sysname> display version     

H3C Comware Software, Version 9.1.063, Release 9141P16      ------- 注①                                                                         

Copyright (c) 2004-2024 New H3C Technologies Co., Ltd. All rights reserved.                                                        

H3C MSR1000 uptime is 0 weeks, 2 days, 17 hours, 53 minutes                                                                        

Last reboot reason : User reboot                                                                                                    

Boot image: flash:/msr1000-cmw910-boot-r9141p16.bin                                                                                

Boot image version: 9.1.041, Release 9141P16                                                                                        

  Compiled Aug 22 2022 14:00:00                                                                                                    

System image: flash:/msr1000-cmw910-system-r9141p16.bin                                                                             

System image version: 9.1.041, Release 9141P16                                                                                     

  Compiled Aug 22 2022 14:00:00                                                                                                     

                                                                                                                                   

Slot 0: RT-MSR1008 uptime is 0 week, 2 days, 17 hours, 53 minutes                                                                   

 Last reboot reason : User reboot                                                                                                  

 CPU ID: 5                                                                                                                          

 2G bytes DDR4 SDRAM Memory                                                                                                        

 2560M bytes Flash Memory                                                                                                           

 PCB              Version: Ver.B                                                                                                   

 CPLD             Version: 0.0                                                                                                      

 Basic   BootWare Version: 1.04                 ------- 注②                                                                                           

 Extend  BootWare Version: 1.04                                                                                                    

 [FIXED PORTS] CON              (Hardware)Ver.B,   (Driver)1.0,   (CPLD)0.0                                                        

 [FIXED PORTS] GE0/0/0          (Hardware)Ver.B,   (Driver)1.0,   (CPLD)0.0                                                        

 [FIXED PORTS] GE0/0/1          (Hardware)Ver.B,   (Driver)1.0,   (CPLD)0.0                                                        

 [FIXED PORTS] 10GSW            (Hardware)Ver.B,   (Driver)1.0,   (CPLD)0.0                                                        

 [FIXED PORTS] XSFP0/0/10       (Hardware)Ver.B,   (Driver)1.0,   (CPLD)0.0                                                        

 [FIXED PORTS] XSFP0/0/11       (Hardware)Ver.B,   (Driver)1.0,   (CPLD)0.0 

Table 3 MSR1008/MSR2630E-X1/MSR3610E-X1/MSR3610E-X1-DP and fit AP compatibility matrix

AP

File Name

Remarks

WA510H-WW

wa4300h.ipe

 

WA4320-H20

WA530-WW

WA530X-WW

WA5320

WA5320E

WA5320H

WA5320i

WA5320-SI

WA5320-TI

WA536-WW

WA538-WW

WA5530

WA5530-SI

wa5300.ipe

 

WA560-WW

WA5620

WA5620i-ACN

wa5600.ipe

 

WA6320

WA6320-C

WA6320-D

WA6320H

WA6320-SI

WA6322

WA6322H

WA6322H-LI

WA6330

WA6338

wa6300.ipe

 

WA6620

WA6620X

WA6622

WA6628

WA6630X

WA6638

WA6638i

wa6600.ipe

 

WA6528

wa6500.ipe

 

WA6320-HI

WA6320-SI-H20

WA6338-HI

wa6300a.ipe

 

WA6520

WA6520-HI

WA6522

WA6522H-HI

WA6530

WA6526E

wa6500a.ipe

 

 

Upgrading restrictions and guidelines

None

Hardware feature updates

CMW910-R9141P16

Add new hardware:

The MSR5680-X3 (MSU-400-G) router supports the RT-SSD-960G SSD module. For more information, see "Appendix A."

CMW910-R9141P1504

Add new hardware:

·         The MSR1008, MSR2630E-X1, and MSR3610E-X1 routers support the RTXL185-510-H3C 10Gbase-T fiber-to-copper converter.

CMW910-R9141P1501

Add new hardware:

SIC-2E1-G

CMW910-R9141P1202

Add new hardware:

RT-XMIM-1CPOS

RT-XMIM-4XP

CMW910-R9141P07

Add new hardware:

MSR5680-X3MSU-400-G

MSR5680-X3MSU-100/MSU-200

CMW910-R9119P17

None

CMW910-R9119P16

None

CMW910-R9119P15

None

CMW910-R9119P12

None

Software feature and command updates

For more information about the software feature and command update history, see H3C MSR1000_MSR26_MSR36_MSR56-CMW910-R9141P16 Release Notes (Software Feature Changes).

MIB updates

None.

Operation changes

None

Restrictions and cautions

·         R9119P14 and earlier versions do not support Web configuration. Do not configure features through Web. To use Web UI, upgrade the software version to R9135P04 or later as a best practice.

·         Do not insert or remove interface cards during an upgrade.

·         Do not insert or remove interface cards frequently during normal operation.

·         Before inserting or removing an interface card, make sure both MPUs are in normal state.

·         Cluster management (CM) ports are not supported in the current software version.

Open problems and workarounds

202501020290

·         Symptom: When a FlexE interface on an MSR5680-X3/MSR3610-G router is configured with a 1G/5G logical interface and receives a large amount of traffic for a long time, few packets are lost.

·         Condition: This symptom occurs if a FlexE interface on an H3C MSR5680-X3/MSR3610-G router is configured with a 1G/5G logical interface and receives a large amount of traffic for a long time.

·         Workaround: None. This problem will be fixed in later versions.

202412131333

·         Symptom: When multiple subinterfaces on a device have the same VRID configured, shutting down one subinterface causes connectivity issues for the other subinterfaces.

·         Condition: This symptom occurs if you configure multiple subinterfaces on a device with the same VRID and then shut down one of the subinterfaces.

·         Workaround: No impact on functionality. This problem will be fixed in later versions.

List of resolved problems

Resolved problems in CMW910-R9141P16

202411122074

·         Symptom: On an MSR5680-X3, traffic is assigned to different cores unexpectedly upon decapsulation in the single-flow scenario.

·         Condition: This symptom might occur if the MSR5680-X3 processes MPLS traffic.

202411110424

·         Symptom: When the MSR5680-X3 MSU400 device sends traffic through an extended SDWAN tunnel, traffic is assigned to different cores unexpectedly upon decapsulation in the single-flow scenario.

·         Condition: This symptom occurs if the MSR5680-X3 MSU400 device sends traffic through an extended SDWAN tunnel.

202502060406

·         Symptom: NetStream does not collect IP layer statistics on an interface after you execute the following commands in sequence: ip netstream mpls, ip netstream inbound (on the interface), and undo ip netstream mpls.

·         Condition: This symptom occurs if you execute the following commands in sequence: ip netstream mpls, ip netstream inbound (on the interface), and undo ip netstream mpls.

Resolved problems in CMW910-R9141P1504

202411090221

·         Symptom: On an MSR26E/MSR36E/MSR1008 router or MSU400 of an MSR5680-X3 router, an interface continuously forwards traffic for NetStream statistics collection. The statistics are cleared when a default clearance time is reached. However, the statistics are cleared again before the next default clearance time is reached..

·         Condition: This symptom occurs if an interface continuously forwards traffic for NetStream statistics collection on an MSR26E/MSR36E/MSR1008 router or MSU400 of an MSR5680-X3 router.

202411081588

·         Symptom: When you configure a time range and daylight saving time on the H3C MSR1008, MSR2630E-X1, MSR3610E-X1 device, the time range does not take effect after the daylight saving time takes effect.

·         Condition: This symptom might occur if you configure a time range on the H3C MSR1008, MSR2630E-X1, MSR3610E-X1 device, and then configure the daylight saving time.

Resolved problems in CMW910-R9141P1501

202410161612

·         Symptom: After the physical state of an SDWAN tunnel flaps on an H3C MSR1008/MSR2630E-X1/MSR3610E-X1/MSR5680-X3 router, the state will always be displayed as down on the controller.

·         Condition: This symptom occurs if the physical state of an SDWAN tunnel flaps on an H3C MSR1008/MSR2630E-X1/MSR3610E-X1/MSR5680-X3 router.

202309081092

·         Symptom: The output from the display version command on the H3C MSR2630E-X1/MSR3610E-X1 device displays the Flash Memory field incorrectly.

·         Condition: This symptom might occur if you execute the display version command on the H3C MSR2630E-X1/MSR3610E-X1 device.

202306270991

·         Symptom: The 10-GE interfaces on an H3C MSR1008/MSR2630E-X1/MSR3610E-X1 router cannot be configured to operate in Layer 2 (bridge) mode.

·         Condition: This symptom occurs if you configure 10-GE interfaces on an H3C MSR1008/MSR2630E-X1/MSR3610E-X1 router to operate in Layer 2 (bridge) mode.

202401181104

·         Symptom: The continuously increasing memory occupation causes the router to reboot in a scenario where the number of NetStream entries on the H3C MSR2630E-X1 or MSR3610E-X1 router exceeds the specification.

·         Condition: This symptom occurs in a scenario where the number of NetStream entries on the H3C MSR2630E-X1 or MSR3610E-X1 router exceeds the specification.

202403190961

·         Symptom: The MBUF memory increases after you enable NetStream on an interface of the H3C MSR2630E-X1 or MSR3610E-X1 router and the interface receives TCP packets with the FIN flag set to 1.

·         Condition: This symptom occurs after you enable NetStream on an interface of the H3C MSR2630E-X1 or MSR3610E-X1 router and the interface receives TCP packets with the FIN flag set to 1.

202403280214

·         Symptom: The inbound traffic rate on the H3C MSR5680-X3 device exceeds the upper limit of 1 Gbps on an interface on the XMIM-8GEE-R/XMIM-8GEF-R subcard. In addition, the interface is expected to forward the inbound traffic.

·         Condition: This symptom might occur if the inbound traffic rate on the H3C MSR5680-X3 device exceeds the upper limit of an interface on the XMIM-8GEE-R/XMIM-8GEF-R subcard that is expected to forward the inbound traffic.

202404200984

·         Symptom: After receiving responses from the DHCP server that contain both DHCP Option 3 and Option 121, H3C MSR2630E-X1 or MSR3610E-X1 generates static routes based only on Option 121. The device should use Option 3 to generate static routes.

·         Condition: This symptom occurs if H3C MSR2630E-X1 or MSR3610E-X1 acts as a DHCP client and receives responses from the DHCP server that contain both DHCP Option 3 and Option 121.

202407270619

·         Symptom: When an HMIC-CLP2 (XMIM-1CPOS subcard) on an H3C MSR5680-X3 connects to a MIC-CLP4L with severe TU12 negative pointer adjustments, MS_BIP(B2) errors will occur, resulting in CRC errors on some serial ports.

·         Condition: This symptom might occur if a card on an H3C MSR5680-X3 connects to a card with severe negative TU12 pointer adjustments.

Resolved problems in CMW910-R9141P1202

202406030654

·         Symptom: The shutdown serial interfaces automatically comes up after the following steps are performed:

a.     Start up the MSR5680-X3 device with MSU400 and MSU200 MPUs in primary/secondary mode starts up with the configuration.

b.    Split the serial ports on E1 cards and assign the split serial interfaces to MP-group interfaces.

c.     Shut down part of the serial interfaces.

d.    Perform a primary/secondary MPU switchover on the device.

·         Condition: This symptom might occur if the following steps are performed:

a.     Start up the MSR5680-X3 device with MSU400 and MSU200 MPUs in primary/secondary mode starts up with the configuration.

b.    Split the serial ports on E1 cards and assign the split serial interfaces to MP-group interfaces.

c.     Shut down part of the serial interfaces.

d.    Perform a primary/secondary MPU switchover on the device.

202405271826

·         Symptom: After an active/standby MPU switchover on the MSR5680-X3 router, the OSPF neighbor connected by the MP-Group link goes down and recovers.

·         Condition: This symptom might occur on the MSR5680-X3 router if the following conditions exist:

¡  HMIC-CLP2/XMIM-1CPOS is split into 31 serial ports with 29 bound to MP-Group and 13 of them active.

¡  The MP-Group link runs OSPF protocol, and an active/standby MPU switchover is triggered.

202405291570

·         Symptom: On MSR5680-X3 devices, you can split HMIC-CLP2/XMIM-1CPOS into 128 serial interfaces. Then, restoring the device to the 128 split-serial-interface configuration failed after the following steps are performed:

a.     Restore the device to the initial configuration.

b.    Perform a primary/secondary MPU switchover.

·         Condition: This symptom might occur if the following steps are performed on the MSR5680-X3 device:

a.     Split serial ports on HMIC-CLP2/XMIM-1CPOS cards into 128 serial interfaces.

b.    Restore the device to the initial configuration.

c.     Perform a primary/secondary MPU switchover on the device.

d.    Restoring the device to the previous 128 split-serial-interface configuration.

202407270619

·         Symptom: When the HMIC-CLP2/XMIM-1CPOS cards on the MSR5680-X3 device interoperate with the remote high-end MIC-CLP4L cards with severe TU-12 pointer negative justification, an MS_BIP(B2) error occurs occur, resulting in CRC errors on some serial interfaces.

·         Condition: This symptom might occur if the device interoperates with the remote cards with severe TU-12 pointer negative justification and the remote sends a large number of packets with TU-12 pointer negative justification.

Resolved problems in CMW910-R9141P07

202310170169

·         Symptom: Some log files in the Comware module are excessively large, causing high memory usage on the device.

·         Condition: This symptom occurs if some log files in the Comware module are excessively large.

202310251511

·         Symptom: The PPPoE, DHCP, and VRRP settings on an interface are lost or do not take effect after the device is reboot or a configuration rollback is performed.

·         Condition: This symptom might occur if you configure PPPoE, DHCP, and VRRP on an interface and then reboot the device or roll back to a configuration with PPPoE, DHCP, and VRRP settings.

202310181880

·         Symptom: CPU threshold alarms and LIPC alarms are generated or some subinterfaces cannot come up after an active/standby MPU switchover or a configuration rollback.

·         Condition: This symptom might occur if more than 1000 subinterfaces exist.

202311231391

·         Symptom: Outgoing packets are dropped on a POS card after an active/standby MPU switchover.

·         Condition: This symptom might occur if you have specified the oc-12-pos mode for the POS card and configured HDLC.

202311270097

·         Symptom: During device operation, the EMMC access failure might occur with a low probability. This causes abnormal device file management and prevents automatic recovery.

·         Condition: This symptom might occur if the device is operating.

Resolved problems in CMW910-R9119P17

202307030141

·         Symptom: The NetStream output packets are sent on the control core 0, which consumes a significant amount of CPU resources. Heavy traffic causes packet transmission failures for protocols like BGP due to CPU resource issues, leading to service flapping.

·         Condition: This symptom occurs if protocol flapping occurs during forwarding of a large number of packets.

202308070219

·         Symptom: If repeated attempts are made to log in to the device via Telnet with incorrect passwords, or if the device is attacked by similar operations, some memory files in the device might not be properly deleted. Prolonged operations or attacks can lead to insufficient memory in the device, causing a device reboot.

·         Condition: This symptom occurs if repeated attempts are made to log in to the device via Telnet with incorrect passwords, or if the device is attacked by similar operations.

202305310821

·         Symptom: Send a massive amount of traffic to the device to generate 10 million fast forwarding entries, which causes the memory usage to approach the minor memory threshold. After the fast forwarding entries age out, 30% of the memory is not released and is inaccessible.

·         Condition: This symptom occurs if the device receives a massive amount of traffic and generates a large number of fast forwarding entries, which occupy a large amount of memory.

202305300744

·         Symptom: Interface XGE 0/0/10 on an MSR3610E/MSR2630E router fails to come up after it is connected to a peer interface.

·         Condition: This symptom occurs with a low probability if you perform the following steps sequentially when connecting XGE 0/0/10 to a peer interface:

a.     Connect optical fibers to a transceiver module.

b.    Insert the transceiver module with optical fibers to XGE 0/0/10.

202305251947

·         Symptom: A combo interface on an MSR3610E/MSR2630E router fails to come up when the fiber port of the combo interface is active and a 100 Mbps transceiver module is inserted into the fiber port.

·         Condition: The symptom occurs if the fiber port of a combo interface on an MSR3610E/MSR2630E router is active and a 100 Mbps transceiver module is inserted into the fiber port.

202305221038

·         Symptom: On the Network > Port Management page of the Web interface, configure an interface to operate in half duplex mode and then configure it to operate in full duplex mode, and configure the interface to operate at 1 Gbps. In this case, the system prompts that the configuration fails to be deployed.

·         Condition: This symptom occurs if the following operations are performed on the Network > Port Management page of the Web interface:

a.          Configure an interface to operate in half duplex mode and then configure it to operate in full duplex mode.

b.         Configure the interface to operate at 1 Gbps.

202305191517

·         Symptom: The Output(Total) field value, which displays the number of outgoing packets on an interface, is displayed abnormally. The PPS value in the Last 30 seconds outputs field for an interface is abnormal. As a result, the interface bandwidth is exceeded and the bandwidth usage reaches 100%, and alarms are generated.

·         Condition: This symptom might occur if interface data reading actions are performed concurrently for many times, which will cause the driver to collect statistics incorrectly with a low probability.

202304230323

·         Symptom: On the Web interface, the per-IP TCP connection upper limit does not take effect.

·         Condition: This symptom occurs if you perform the following operations:

a.          On the Add Connection Limit Rule page, configure the per-IP connection upper limit and per-IP UDP connection upper limit, and click Apply.

b.         Click the edit icon for the rule, configure the per-IP TCP connection upper limit on the Modify Connection Limit Rule page, and click Apply.

c.          Click the edit icon for the rule, delete the per-IP UDP connection upper limit on the Modify Connection Limit Rule page, and click Apply.

202304131322

·         Symptom: For the MSR device, if you configure Track to monitor collaboration between static route and NQA, packet loss might occur in the NQA ICMP-echo operation.

·         Condition: This symptom might occur with a certain probability if you configure Track to monitor collaboration between static route and NQA for the MSR device.

202303151443

·         Symptom: A fiber port from the 6193X chip on an MSR router comes up and goes down frequently when only the RX of the port is connected with an optical fiber.

·         Condition: This symptom occurs if only the RX of a fiber port from the 6193X chip on a MSR router is connected with an optical fiber.

Resolved problems in CMW910-R9119P16

202302211003

·         Symptom: A device cannot ping a destination because the actual length of the ICMP echo requests is not the same as the length specified in the ping –s -r command.

·         Condition: This symptom occurs if the echo request length specified in the ping –s -r command is 200 with a fluctuation around 20.

202302201459

·         Symptom: On the Network > LAN Settings page of the Web interface for the MSR device, no prompt message appears when you switch an interface from a GE interface to a LAN interface.

·         Condition: This symptom might occur if you switch an interface from a GE interface to a LAN interface on the Network > LAN Settings page of the Web interface for the MSR device.

202302040295

·         Symptom: On the System Information page of the Web interface for the MSR device, the interface rate statistics graph does not display traffic statistics on interfaces.

·         Condition: This symptom might occur if you view traffic statistics on an interface on the corresponding rate statistics graph on the System Information page of the Web interface for the MSR device.

202212130756

·         Symptom: When you create an application group, and then upgrade the APR signature library, you cannot edit the application group after the upgrade. However, the system still displays that the application group is user-defined.

·         Condition: This symptom might occur if you create an application group, upgrade the APR signature library, and then edit the application group after the upgrade.

202211030757

·         Symptom: If you enable DHCP snooping both globally and for VLANs in different configuration orders, the effective rules issued to the driver are different. As a result, DHCP snooping malfunction occurs.

·         Condition: This symptom might occur if DHCP snooping is enabled both globally and for VLANs.

202304030297

·         Symptom: When BGP uses a peer address range (non-unicast addresses) to establish peer relationships, it cannot correctly establish peer relationships with some of the addresses in the address range.

·         Condition: This symptom occurs if BGP uses a peer address range (non-unicast addresses) to establish peer relationships.

202304240520

·         Symptom: The overall forwarding efficiency degrades after the device receives a large number of packets to unknown destinations.

·         Condition: This symptom might occur after the device receives a large number of packets to unknown destinations.

Resolved problems in CMW910-R9119P15

202212280307

·         Symptom: PPPoE dialup is performed on a WAN interface. After an L2TP user comes online and pings the VT interface address, the LNS crashes and becomes unavailable.

·         Condition: This symptom occurs if the following operations are performed:

a.          PPPoE dialup is performed on a WAN interface.

b.         After an L2TP user comes online, the user pings the VT interface address.

202209030481

·         Symptom: The device prints Deadloop detected on cpu 0 core 1 repeatedly and fails to forward NAT traffic of the NAT session last established.

·         Condition: This symptom occurs if have configured a large number of NAT server mappings that meet the following conditions:

¡  Each NAT server mapping has the same public IP address and different public port numbers.

202206200185

·         Symptom: Fragmented SCTP data packets cannot be forwarded because the first fragmented SCTP data packet is dropped by ASPF.

·         Condition: This symptom occurs if fragmented SCTP data packets cannot be forwarded.

202206230754

·         Symptom: After a USB drive is removed, .the device mistakenly prompts the message The device does not exist when you save a .cfg file to the previous path for the removed USB drive.

·         Condition: This symptom might occur when you save a .cfg file to the previous path for a removed USB drive.

202206021368

·         Symptom: After an amount of traffic triggers MAC authentication, some MAC addresses are mistakenly added to the MAC address table as dynamically learned MAC addresses.

·         Condition: This symptom might occur when you view the MAC address table after an amount of traffic triggers MAC authentication.

202207040549

·         Symptom: The device is installed with a SIC-5G interface module and two SIM cards are present. When the primary SIM card has no signal or the dialup fails, the device fails to switch to the secondary SIM card.

·         Condition: This symptom might occur when two SIM cards are present and the primary SIM card has no signal or the dialup fails.

202206291452

·         Symptom: When the IPv6 single-stack automatic dialup mode is configured on a 5G interface, the 5G interface cannot automatically dial up to obtain an IPv6 address after the modem is rebooted. You must delete and then execute the ipv6 address cellular-alloc command again.

·         Condition: This symptom occurs if the IPv6 single-stack automatic dialup mode is configured on a 5G interface and the modem is rebooted.

202206291094

·         Symptom: IMC cannot sample flows based on the BGP AS number by using the NetStream component.

·         Condition: This symptom occurs if IMC samples flows based on the BGP AS number by using the NetStream component.

202206231138

·         Symptom: If the display interface brief command is executed when a large number of subinterfaces are configured, the command output is displayed slowly.

·         Condition: This symptom occurs if the display interface brief command is executed when a large number of subinterfaces are configured and you view the command output.

202206171668

·         Symptom: Delete the segment-routing ipv6 configuration, and then deploy the locator configuration. Additional anycast enable configuration is generated.

·         Condition: This symptom occurs when you delete the segment-routing ipv6 configuration, and then deploy the locator configuration.

202205231309

·         Symptom: When the device run OSPFv3 in some scenarios, the OSPFv3 process might failed to be deployed. After you use the follow command to display stack information for the process, the process will recover.

·         Condition: This symptom occurs if the following conditions exist:

a.          You use the vpn-instance command to create a VPN instance, and no OSPFv3 instances run on the VPN instance.

b.         You use the ip binding vpn-instance command associate an interface with the VPN instance.

You configure an IPv6 address for the interface by using the ipv6 address command.

You execute a minimum of one OSPFv3 pre-configuration command on the interface, but do not enable OSPFv3 on the interface.

c.          You perform one of the following tasks:

-      You use the undo ip binding vpn-instance command to unbind the VPN instance from the interfaces on the device.

When the device has only one interface associated with the VPN instance and you continue to unbind the interface from the VPN instance, this symptom might occur.

-      You delete the VPN instance directly.

202204131807

·         Symptom: The device has two ECMP routes to reach an IP address. The output interface of one route is a main interface and the output interface of the other route is a subinterface of the main interface. When you ping the IP address, the device sends the ICMP echo requests through the subinterface, but the source IP address of the requests is the IP address of the main interface.

·         Condition: This symptom occurs if the following conditions exist:

¡  The device has two ECMP routes to reach the pinged IP address.

¡  The output interface of one route is a main interface and the output interface of the other route is a subinterface of the main interface.

202206110680

·         Symptom: The ping communication over an IPsec tunnel fails on the SR6602-I/IE device.

·         Condition: This symptom occurs when the interface applied with an IPsec policy has a MTU greater than 2000, the IPsec uses the built-in hardware encryption card and GM encryption card, and the packet length is between 1931 to 1946 bytes.

Resolved problems in CMW910-R9119P12

202205190948

·         Symptom: In an EVPN L3VPN over SRv6 network, the device takes about half an hour before it can advertise EVPN private network routes to peers after L2VPN is enabled and then disabled on it.

·         Condition: This symptom occurs if the following operations are performed on the device in an EVPN L3VPN over SRv6 network:

a.          Enable L2VPN and then disable it.

b.         Re-advertise EVPN private network routes.

202205171465

·         Symptom: The console is stuck after the docker start -i comware command is executed in system view.

·         Condition: This symptom occurs if you execute the docker start -i comware command in system view.

202205131400

·         Symptom: The console is stuck after the packet-capture interface xx port x command is executed in user view.

·         Condition: This symptom occurs if you execute the packet-capture interface xx port x command in user view.

202205230921

·         Symptom: Enable webcache (with listening port 179), configure BGP, and then delete the webcache configuration. The BGP neighbor relationship cannot be established. This issue cannot be resolved by executing the reset bgp command. You must reconfigure BGP to resolve this issue.

·         Condition: This symptom occurs when you enable webcache (with listening port 179), configure BGP, and then delete the webcache configuration.

202205231503

·         Symptom: After you issue PBR settings on the Web interface, the PBR page gets stuck, and the system cannot display the issued PBR settings. You can restore the page by deleting all PBR settings at the back end.

·         Condition: This symptom occurs when you issue PBR settings on the Web interface.

202205191658

·         Symptom: When the device is low on memory, the OS kills the BGP process and the COMSH process. After the device memory restores to normal condition, the device does not restart those processes.

·         Condition: The device is low on memory.

202205240918

·         Symptom: In a multihomed EVPN VPWS site, a PE encapsulates incorrect private labels into packets, and traffic forwarding fails as a result.

·         Condition: This symptom occurs if IS-IS is reset and a PE sends traffic to remote PEs at a dualhomed site.

202204280573

·         Symptom: The nat server command does not take effect.

·         Condition: This symptom occurs if you specify the private port as dns when executing the nat server command.

202204140101

·         Symptom: In an EVPN VPWS over SRv6 network, the entries in user mode and kernel mode are inconsistent when multiple SRv6 TE ECMP tunnels exist.

·         Condition: This symptom occurs in an EVPN VPWS over SRv6 network if multiple SRv6 TE ECMP tunnels exist..

Related documentation

Documentation set

·         H3C MSR1000 Router Series Installation Quick Start

·         H3C MSR2630E-X1 Router Installation Quick Start

·         H3C MSR3610E-X1[-X1-DP] Router Installation Quick Start

·         H3C MSR3610E-X1[-X1-DP] Routers Installation Guide

·         H3C MSR3610E-X1[-X1-DP] Routers Hardware Information and Specifications

·         H3C MSR2630E-X1 Router Installation Guide

·         H3C MSR2630E-X1 Router Hardware Information and Specifications

·         H3C MSR1000 Router Series Installation Guide

·         H3C MSR1000 Router Series Hardware Information and Specifications

·         H3C MSR Router Series Interface Module Guide

·         H3C MSR1000[2600][3610] Routers Configuration Guides(V9)-R9119

·         H3C MSR1000[2600][3610] Routers Command Reference(V9)-R9119

·         H3C MSR5680-X3 Router Installation Guide

·         H3C MSR5680-X3 Router Hardware Information and Specifications

·         H3C MSR5680-X3 Router Installation Quick Start

·         H3C MSR Router Series Interface Module Guide

·         H3C MSR5680-X3 Router Command Reference

·         H3C MSR5680-X3 Router Configuration Guides

Obtaining documentation

Take the following steps to get related documents from the H3C website at www.h3c.com.

1.         Go to  https://www.h3c.com/

2.        Choose the desired product category and model.

Technical support

To obtain technical assistance, contact H3C by using one of the following methods:

·         Email:

[email protected] (countries and regions except Hong Kong, China)

[email protected] (Hong Kong, China)

·         Technical support hotline number. To obtain your local technical support hotline number, go to the H3C Service Hotlines website: https://www.h3c.com/en/Support/Online_Help/Service_Hotlines/

To access documentation, go to the H3C website at http://www.h3c.com/en/.


Appendix A Feature list

Hardware features

Table 1 MSR1008 routers Technical specifications

Item

Specifications

Console port

1

USB port

1

GE copper port

10, including two combo ports

GE fiber ports

2, combo ports

10 GE fiber port

2

Built-in 5G module

N/A

5G ANT ports

N/A

GNSS antenna port

N/A

Memory

2 GB DDR4

Flash

4 GB

Dimensions (H × W × D) (excluding rubber feet and mounting brackets)

43.6 × 266 × 161 mm (1.72 × 10.47 × 6.34 in)

Input voltage

100 to 240 VAC @ 50 to 60 Hz

Max power consumption

14.7 W

Operating temperature

0°C to 45°C (32°F to 113°F)

Operating humidity

5% RH to 95% RH, noncondensing

 

Table 2 MSR2630E-X1 routerTechnical specifications

Item

Specifications

Console port

1

GE copper ports

2 (combo interfaces) + 8

GE fiber ports

2 (combo interfaces)

10GE fiber ports

3

USB port

1

SIC slots

2

AC power receptacles

1

Memory

4 GB DDR4

Flash

4 GB EMMC

Dimensions (H × W × D) (excluding mounting brackets and rubber feet)

44.2 × 360 × 300 mm (1.74 × 14.17 × 11.81 in)

Rated AC voltage

100 VAC to 240 VAC @ 50 or 60 Hz

Maximum power consumption

39 W

Operating temperature

·        Operating: 0°C to 45°C (32°F to 113°F)

·        Storage: –40°C to +70°C (–40°F to +158°F)

Relative humidity (non-condensing)

5% RH to 95% RH, noncondensing

 

Table 3 MSR3610E-X1[-DP] routerTechnical specifications

Item

MSR3610E-X1

MSR3610E-X1-DP

Console port

1

1

GE copper ports

2 (combo interfaces) + 8

2 (combo interfaces) + 8

GE fiber ports

2 (combo interfaces)

2 (combo interfaces)

10GE fiber ports

3

3

USB port

1

1

SIC slots

4

4

AC power receptacles

1

2

Memory

4 GB DDR4

4 GB DDR4

Flash

4 GB EMMC

4 GB EMMC

Dimensions (H × W × D) (excluding mounting brackets and rubber feet)

44.2 × 440 × 320 mm (1.74 × 17.32 × 12.60 in)

44.2 × 440 × 320 mm (1.74 × 17.32 × 12.60 in)

Rated AC voltage

100 VAC to 240 VAC @ 50 or 60 Hz

100 VAC to 240 VAC @ 50 or 60 Hz

Maximum power consumption

45 W

45 W

Operating temperature

·        Operating: 0°C to 45°C (32°F to 113°F)

·        Storage: –40°C to +70°C (–40°F to +158°F)

·        Operating: 0°C to 45°C (32°F to 113°F)

·        Storage: –40°C to +70°C (–40°F to +158°F)

Relative humidity (non-condensing)

5% RH to 95% RH, noncondensing

5% RH to 95% RH, noncondensing

Table 4 MSR5680-X3 technical specifications

Item

Specification

Dimensions (H × W × D) (excluding rubber feet and mounting brackets)

175 × 440 × 330 mm (6.89 × 17.32 × 12.99 in)

Chassis weight (including mounting brackets and filler panels)

10.62 kg (23.41 lb)

Chassis weight (fully configured)

22.5 kg (49.60 lb)

Device weight

Weights of the chassis (including mounting brackets and filler panels), modules, power supplies, fan trays, and other removable components

System power consumption

Total power consumption of all modules and fan trays

Heat dissipation

Heat dissipation of the router per hour is 0.9 × (total power consumption of all modules and fan trays)/0.9 × 3.4121

MSU slots

2

XMIM interface module/SSD slots

8

Fan tray slots

2

Power supply slots

3

Operating temperature

0°C to 45°C (32°F to 113°F)

Operating humidity

5% RH to 95% RH, noncondensing

 

Table 5 M.2 SSD specifications

Model

Capacity

Interface type

Interface rate

RT-SSD-960G

960 GB

SATA

3 Gbps

 

Table 6 Interface modules available for the MSR1008/MSR2630E-X1/MSR3610E-X1/MSR3610E-X1-DP router

For compatibility between the router and interface modules, see the interface module guide for the router.

Item

Description

SIC

WAN interface modules:

·        SIC-1E1-F-V3-H3: 1-port fractional E1 interface SIC module

·        SIC-2E1-F-H3: 2-port fractional E1 interface SIC module

·        SIC-5G: 5G NR (NSA/SA/4G FDD/TDD LTE-A/3G WCDMA,Sub6,GNSS) SIC module

·        SIC-2E1-G2-Port Fractional E1 (E1-F)-RJ45 or Channelized E1 (CE1/PRI)-RJ45 Interface SIC Module

·        SIC-2SAE: 2-port Enhanced Sync/Async Serial SIC Module

·        SIC-4SAE: 4-port Enhanced Sync/Async Serial SIC Module

·        SIC-8AS-H3: 8-Port Asynchronous Serial Interface SIC Module

·        SIC-16AS-H3: 16-Port Asynchronous Serial Interface SIC Module

·        SIC-2E1-F-H3: 2-Port Fractional E1 Interface SIC Module

·        SIC-1E1-F-V3-H3: 1-Port Fractional E1 Interface SIC Module

·        SIC-5G:5G(5G NR/NSA/SA/4G FDD/TDD LTE-A/3G WCDMA,Sub6,GNSS)SIC Module

·        SIC-M2-SATA:M.2 Riser(1 SATA 3.0) SIC Module

 

Table 7 MSR5680-X3MSU-400-G route Module List

For hardware compatibility with the interface modules, see H3C MSR Router Series Interface Module Guide.

Item

Specification

MSU

·        H3C MSU-400-G Main-control and Service-processing Unit (10*10GE(SFP+),8*GE(RJ45)) - MSU-400-G

XMIM

·        8-Port 100/1000BASE-T-RJ45 L3 Interface XMIM Module - XMIM-8GEE-R

·        8-Port 100/1000BASE-X-SFP L3 Interface XMIM Module - XMIM-8GEF-R

·        4-Port 10GBASE-R-SFP+ L3 Interface XMIM Module - XMIM-4XP

·        8-Port Fractional E1 (E1-F)-RJ45 or Channelized E1 (CE1/PRI)-RJ45 Interface XMIM Module - XMIM-8E1

·        4-Port Fractional E1 (E1-F)-RJ45 or Channelized E1 (CE1/PRI)-RJ45 Interface XMIM Module - XMIM-4E1

·        2-Port Fractional E1 (E1-F)-RJ45 or Channelized E1 (CE1/PRI)-RJ45 Interface XMIM Module - XMIM-2E1

·        2-Port OC-3c/STM-1c-SFP or 1-Port OC-12c/STM-4c-SFP Interface XMIM Module - XMIM-2POS

·        1-Port OC-3c/STM-1c-SFP or 1-Port OC-12c/STM-4c-SFP Interface XMIM Module - XMIM-1POS

·        1-Port OC-3/STM-1 Channelized POS Optical Interface XMIM Module - XMIM-1CPOS

Table 8 MSR5680-X3MSU-100/MSU-200 route Module List

For hardware compatibility with the interface modules, see H3C MSR Router Series Interface Module Guide.

Item

Specification

MSU

·        H3C MSU-100 Main-control and Service-processing Unit - MSU-100

·        H3C MSU-200 Main-control and Service-processing Unit - MSU-200

SIC

·        5G NR (NSA/SA/4G FDD/TDD LTE-A/3G WCDMA,Sub6,GNSS) SIC Module - SIC-5G

XMIM

·        8-Port 100/1000BASE-T-RJ45 L3 Interface XMIM Module - XMIM-8GEE-R

·        8-Port 100/1000BASE-X-SFP L3 Interface XMIM Module - XMIM-8GEF-R

·        8-Port Fractional E1 (E1-F)-RJ45 or Channelized E1 (CE1/PRI)-RJ45 Interface XMIM Module - XMIM-8E1

·        4-Port Fractional E1 (E1-F)-RJ45 or Channelized E1 (CE1/PRI)-RJ45 Interface XMIM Module - XMIM-4E1

·        2-Port Fractional E1 (E1-F)-RJ45 or Channelized E1 (CE1/PRI)-RJ45 Interface XMIM Module - XMIM-2E1

·        2-Port OC-3c/STM-1c-SFP or 1-Port OC-12c/STM-4c-SFP Interface XMIM Module - XMIM-2POS

·        1-Port OC-3c/STM-1c-SFP or 1-Port OC-12c/STM-4c-SFP Interface XMIM Module - XMIM-1POS

·        1-Port OC-3/STM-1 Channelized POS Optical Interface XMIM Module - XMIM-1CPOS

 

Software features

Table 1 MSR Series routers software features

Category

Features

Layer 2 protocols

·     ARP: Dynamic ARP, static ARP, proxy ARP, and gratuitous ARP

·     ARP snooping

·     ARP detection

·     Ethernet and subinterface VLAN

·     Link Aggregation Control Protocol (LACP)

·     QinQ termination

·     Layer 2 Ethernet interface, VLAN interface

·     STP/RSTP/MSTP

·     MAC address management

·     Link Aggregation Control Protocol (LACP)

·     802.1Q

·     Switch port mirroring

·     Broadcast storm suppression

·     QinQ

·     Loopback detection

·     Priority mapping

·     LLDP

WAN access

·     PPP, MP

·     HDLC, HDLC bundle

·     DDR

·     PPPoE client

·     4G LTE

·     5G

·     ISDN

IP services

·     TCP, UDP, IP option, and IP unnumbered

·     Policy-based routing

IP routing

·     Static routing (supporting both IPv4 and IPv6)

·     Dynamic routing protocols: RIPv1/v2, OSPFv2, BGP, and IS-IS

·     Route recursion

·     Routing policy (supporting both IPv4 and IPv6)

·     Equal-cost multi-path (ECMP) (supporting both IPv4 and IPv6)

·     Unequal-cost multi-path (UCMP) (bandwidth-based load balancing, supporting both IPv4 and IPv6)

·     BGP-LS

·     BGP flowspec

IPv4 multicast

·     IGMPv1/v2/v3

·     IGMP snooping

·     PIM-DM, PIM-SM, PIM-SSM, and bidirectional PIM (supporting both IPv4 and IPv6)

·     MSDP

·     NGMVPN

·     MBGP

·     Multicast static route

·     Multicast neighbor tracking

IP applications

·     DHCP server, DHCP relay, and DHCP client

·     DHCPv4 snooping

·     DHCPv6 snooping

·     DNS client, static DNS, DNS proxy, and DDNS

·     NTP server and client

·     Telnet server and client

·     TFTP client

·     FTP server and client

·     UDP helper

·     Wide Area Application Services (WAAS)

·     Web caching

IPv6

·     Basic functions: IPv6 ND, IPv6 PMTU, dual-stack forwarding, IPv6 unicast policy-based routing forwarding, IPv6 ACL, DHCPv6 server, and DHCPv6 proxy

·     IPv6 tunneling technologies: Manual IPv6 tunnel, IPv6-over-IPv4, GRE tunnel, automatic IPv4-compatible IPv6 tunnel, 6to4 tunnel, ISATAP tunnel, 6PE, and 6RD

·     6VPE (IPv6 MPLS L3VPN)

·     IPv6 static routing

·     Dynamic routing protocols: RIPng, OSPFv3, IS-ISv6, and BGP4+

·     IPv6 multicast protocols: MLDv1/v2, MLD snooping, PIM6-DM, PIM6-SM, PIM6-SSM, and bidirectional PIM

·     NAT-PT/NAT64

·     NPTv6

·     SRv6

QoS

·     Traffic classification based on port, IP address, IP priority, DSCP priority, TCP/UDP port number, protocol type, and so on

·     Priority marking

·     Traffic policing: CAR rate limiting and configurable granularity

·     Rate limiting based on source or destination addresses (supporting network segment rate limiting)

·     GTS

·     Various queuing algorithms: FIFO, PQ, CQ, WFQ, CBQ, RTPQ, and SP

·     Congestion avoidance algorithms: Tail-Drop, WRED, and RED

·     LR rate limiting

·     QoS policy nesting

·     Other QoS technologies: MPLS QoS, MP QoS, LFI, and QoS policy propagation on BGP (QPPB)

·     Routing interface channelization and aggregate interface channelization

Security

·     Access control list (ACL)

·     Time range-based ACL

·     Packet filtering firewall

·     TCP attack prevention

·     uRPF

·     Hierarchical user management and password protection

·     Authentication, authorization, and accounting (AAA) services

·     Local authentication

·     RADIUS

·     TACACS

·     PPPoE server

·     Portal authentication (supporting collaboration with EAD and portal fail-permit)

·     MAC address authentication

·     802.1x

·     Support port security

·     IP source guard

·     PKI certificate

·     SSH 1.5 and SSH 2.0

·     RSA

·     IPsec, IPsec in multi-VPN instance scenarios, and IKE

·     Password control

·     Auto Discovery VPN (ADVPN)

·     GDVPN

·     ASPF

·     Object group

·     Attack detection and prevention

In-depth security

·     APR

·     IPS

·     Predefined and custom applications

·     Offline and online manual upgrade of signature libraries, signature library rollback

IP services

·     NAT, NAT in multi-VPN instance scenarios, NAT 444, and NAT logging

·     NAT server load sharing

·     Connection limit

·     GRE tunnel

·     L2TP tunnel

·     NetStream support for exporting data in v5/v8/v9 format and collecting IPv4/IPv6/MPLS packet statistics

·     Web caching

WLAN

·     WLAN AC

MPLS

·     L3VPN: Inter-AS MPLS VPN (Option1/2/3), nested MPLS VPN, Hierarchy of PE (HoPE), dual-homed CEs, MCE, multi-role host, and so on

·     L2VPN: Martini, Kompella, CCC, and SVC methods

·     VPLS/H-VPLS

·     MPLS TE and RSVP TE

·     Multicast VPN

·     MPLS SR

·     CBTS

SDN features

·        EVPN

·        Telemetry

·        Intelligent path selection

·        Automated initial deployment

·        Cloud management tunnel

·        SRv6

VXLAN

·     VXLAN

High availability

·     Virtual Router Redundancy Protocol (VRRP)/VRRPv3

·     VRRP Extended (VRRPE)

·     MPLS TE Fast ReRoute (FRR)

·     IP FRR: static routing, policy routing, RIP, IS-IS, and OSPF

·     VPN FRR

·     IGP fast route convergence

·     BFD: Static route, RIP, OSPF, ISIS, BGP, VRRP, TE FRR, and IPv6

·     GR: OSPF, BGP, IS-IS, and LDP

·     Software hot patches

·     MPLS OAM

·     Hot swapping slots

·     Hot swapping of interface modules

Management and maintenance

·        Configuration through the CLI

·        Configuration through the console port

·        Configuration and remote maintenance through an Ethernet port using Telnet

·        Login through SSH

·        Login through FTP

·        Role-based access control (RBAC)

·        Configuration and management via SNMP (SNMPv1/v2c/v3)

·        RMON (groups 1, 2, 3, and 9 through the MIB)

·        Local port mirroring

·        System logs

·        Alarms at different severity levels

·        Ping and tracert

·        Network quality analyzer (NQA) (supporting collaboration with VRRP, policy routing, and static routing)

·        TWAMP-light

·        NETCONF

·        Embedded Automation Architecture (EAA)

·        Fan status detection, maintenance, and alarm

·        Power status detection, maintenance, and alarm

·        Environmental temperature change detection and alarm

File system

·     FAT/EXT4 file system

·     External disk slots

·     Support for USB external storage devices

·     Support for the dual image feature

·     Support of external disks for HARDWARE RAID (RAID0,1)

Loading and upgrading

·     Loading and upgrading through XModem

·     Loading and upgrading through FTP and TFTP

SRv6

·     L2VPN over SRv6 TE policy/BE

·     L3VPN over SRv6 TE policy/BE

·     EVPN L2VPN over SRv6 TE policy/BE

·     EVPN L3VPN over SRv6 TE policy/BE

·     Public IP over SRv6 TE policy/BE

·     SRv6 OAM

·     SRv6 TI-LFA FRR

·     Collaboration between SRv6 TE policy and SBFD

·     BGP-LS for SRv6

·     CBTS based on five-tuple in SRv6

·     Color, tunnel policy, and DSCP-based traffic steering in SRv6 TE policy scenarios

iFIT

·     iFIT detection in L3VPN over SRv6 TE policy/BE scenarios

·     iFIT detection in EVPN L3VPN over SRv6 TE policy/BE scenarios

·     iFIT detection in public IP over SRv6 TE policy/BE scenarios

Appendix B Upgrading software

This section describes how to upgrade system software while the router is operating normally or when the router cannot correctly start up.

Software types

The following software types are available:

·         Boot ROM image—A .bin file that comprises a basic section and an extended section. The basic section is the minimum code that bootstraps the system. The extended section enables hardware initialization and provides system management menus. You can use these menus to load application software and the startup configuration file or manage files when the device cannot correctly start up.

·         Comware image—Includes the following image subcategories:

¡  Boot image—A .bin file that contains the Linux operating system kernel. It provides process management, memory management, file system management, and the emergency shell.

¡  System image—A .bin file that contains the minimum feature modules required for device operation and some basic features, including device management, interface management, configuration management, and routing. To have advanced features, you must purchase feature packages.

¡  Feature package—Includes a set of advanced software features. Users purchase feature packages as needed.

¡  Patch packages—Irregularly released packages for fixing bugs without rebooting the device. A patch package does not add new features or functions.

Comware software images that have been loaded are called "current software images." Comware images specified to load at the next startup are called "startup software images."

Boot ROM image, boot image, and system image are required for the system to work. These images might be released separately or as a whole in one .ipe package file. If an .ipe file is used, the system automatically decompresses the file, loads the .bin boot and system images and sets them as startup software images.

Upgrade methods

You can upgrade system software by using one of the following methods:

 

Upgrade method

Remarks

Upgrading from the CLI

You must reboot the router to complete the upgrade.

This method can interrupt ongoing network services.

Upgrading from the BootWare menu

Use this method when the router cannot correctly start up.

 

Preparing for the upgrade

Before you upgrade system software, complete the following tasks:

·         Set up the upgrade environment as shown in Table 10.

·         Configure routes to make sure that the router and the file server can reach each other.

·         Run a TFTP or FTP server on the file server.

·         Log in to the CLI of the router through the console port.

·         Copy the upgrade file to the file server and correctly set the working directory on the TFTP or FTP server.

·         Make sure the upgrade has minimal impact on the network services. During the upgrade, the router cannot provide any services.

 

IMPORTANT

IMPORTANT:

In the BootWare menu, if you choose to download files over Ethernet, the Ethernet port must be M-GE0 on an SR6602-I or SR6602-IE router.

 

Table 9 Storage media

Model

Storage medium

Path

Router Types

MSR1008

Flash

flash:/

Centralized devices

MSR2630E-X1

Flash

flash:/

Centralized devices

MSR3610E-X1

Flash

flash:/

Centralized devices

MSR3610E-X1-DP

Flash

flash:/

Centralized devices

MSR5680-X3

Flash

flash:/

distributed devices

 

Figure 1 Set up the upgrade environment

 

Upgrading from the CLI

You can use the TFTP or FTP commands on the router to access the TFTP or FTP server to back up or download files.

Saving the running configuration and verifying the storage space

1.         Save the running configuration.

<Sysname> save

The current configuration will be written to the device. Are you sure? [Y/N]:y

Please input the file name(*.cfg)[flash:/startup.cfg]

(To leave the existing filename unchanged, press the enter key):

Validating file. Please wait...

Saved the current configuration to mainboard device successfully.

<Sysname>

2.        Identify the system software image and configuration file names and verify that the sda0 has sufficient space for the new system software image.

<Sysname> dir

Directory of sda0: (VFAT)

   0 -rw-           0 Sep 18 2020 15:35:36   1

   1 drw-           - Aug 06 2020 17:37:32   core

   2 -rw-          60 Aug 03 2020 17:53:42   database.dhcp

   3 -rw-     5815756 Aug 21 2020 16:19:12   diag.tar.gz

   4 -rw-     5814047 Aug 18 2020 17:36:20   diag_SR6602-I_20200818-173359.tar.g

z

   5 -rw-     5814117 Aug 18 2020 17:42:30   diag_SR6602-I_20200818-174021.tar.g

z

   6 drw-           - Jul 15 2020 15:14:12   diagfile

   7 -rw-        2429 Sep 21 2020 16:48:35   ifindex.dat

   8 drw-           - Sep 07 2020 10:50:04   license

   9 drw-           - Jul 15 2020 16:30:00   logfile

  10 drw-           - Jul 15 2020 16:37:20   pki

  11 drw-           - Jul 15 2020 15:14:12   seclog

  12 -rw-   208731136 Sep 07 2020 10:50:10   msr1000-cmw910-boot-r9112p12.bin

  13 -rw-   175310848 Sep 07 2020 10:50:10   msr1000-cmw910-system-r9112p12.bin

  14 -rw-    47334400 Sep 07 2020 10:50:10   msr1000-cmw910-virtualization-r9112p12

.bin

  15 -rw-   431384576 Sep 04 2020 16:21:54   msr1000.ipe

  16 -rw-       20373 Sep 21 2020 16:48:36   startup.cfg

  17 -rw-      447126 Sep 21 2020 16:48:36   startup.mdb

  18 drw-           - Jul 15 2020 15:15:52   third-party

  19 drw-           - Sep 07 2020 10:50:16   versionInfo

 

3139576 KB total (2266716 KB free)     <Sysname>

Downloading the image file to the router

Using TFTP

Download the system software image file to the sda0 on the router.

<Sysname> tftp 172.32.108.50 get msr1000.ipe

Press CTRL+C to abort.

  % Total    % Received % Xferd  Average Speed   Time    Time     Time  Current

                                 Dload  Upload   Total   Spent    Left  Speed

100  127M  100  127M    0     0   719k      0  0:03:02  0:03:02 --:--:--  638k

Writing file...Done.

<Sysname>

Using FTP

1.         From FTP client view, download the system software image file to the CF card on the router.

<Sysname> ftp 172.32.108.50

Press CTRL+C to abort.

Connected to 172.32.108.50 (172.32.108.50).

220 3Com 3CDaemon FTP Server Version 2.0

User (172.32.108.50:(none)): 1

331 User name ok, need password

Password:

230 User logged in

Remote system type is UNIX.

Using binary mode to transfer files.

ftp> get msr1000.ipe

msr1000.ipe already exists. Overwrite it? [Y/N]:y

local: /mnt/slot1#flash:/msr1000.ipe remote: msr1000.ipe

227 Entering passive mode (172,32,108,50,196,58)

125 Using existing data connection

....................................................................................................................................

226 Closing data connection; File transfer successful.

139764736 bytes received in 14.655 seconds (9.10 Mbytes/s)

ftp>

2.        Return to user view.

[ftp] quit

221 Service closing control connection

 

<Sysname>

Specifying the startup image file

1.         Specify the msr1000.ipe file as the main image file at the next reboot.

<Sysname> boot-loader file flash:/msr1000.ipe all main

Verifying the file flash:/msr1000.ipe on slot 0....Done.

H3C MSR1000 images in IPE:

  msr1000-cmw910-boot-r9112p12.bin

  msr1000-cmw910-system-r9112p12.bin

This command will set the main startup software images. Continue? [Y/N]:y

Add images to slot 1.

File flash:/msr1000-cmw910-boot-r9112p12.bin already exists on slot 0.

File flash:/msr1000-cmw910-system-r9112p12.bin already exists on slot 0.

Overwrite the existing files? [Y/N]:y

Decompressing file flash:/msr1000-cmw910-boot-r9112p12.bin to flash:/flash:/msr1000-cmw910-boot-r9112p12.bin...Done.

Decompressing file msr1000-cmw910-system-r9112p12.bin to flash:/msr1000-cmw910-system-r9112p12.bin...Done.

Verifying the file flash:/msr1000-cmw910-boot-r9112p12.bin on slot 0...Done.

Verifying the file msr1000-cmw910-system-r9112p12.bin on slot 0....Done.

The images that have passed all examinations will be used as the main startup software images at the next reboot on slot 0.

Decompression completed.

Do you want to delete flash:/msr1000.ipe now? [Y/N]:y

<Sysname>

2.        Verify that the file has been loaded.

<Sysname> display boot-loader

Software images on slot 0:

Current software images:

  flash:/msr1000-cmw910-boot-r9112p12.bin

  flash:/msr1000-cmw910-system-r9112p12.bin

  flash:/msr1000-cmw910-virtualization-r9112p12.bin

Main startup software images:

  flash:/msr1000-cmw910-boot-r9112p12.bin

  flash:/msr1000-cmw910-system-r9112p12.bin

  flash:/msr1000-cmw910-virtualization-r9112p12.bin

Backup startup software images:

  None

<Sysname>

Rebooting and completing the upgrade

1.         Reboot the router.

<Sysname> reboot

Start to check configuration with next startup configuration file, please wait.........DONE!

This command will reboot the device. Continue? [Y/N]:y

Now rebooting, please wait...

<Sysname>

System is starting...

2.        After the reboot is complete, verify that the system software image is correct.

<Sysname> display version

H3C Comware Software, Version 9.0.001, Release 9112P06

Copyright (c) 2004-2021 New H3C Technologies Co., Ltd. All rights reserved.

H3C SR6602 uptime is 0 weeks, 0 days, 0 hours, 0 minutes

Last reboot reason : User reboot

Boot image: flash:/msr1000-cmw910-boot-r9112p12.bin

Boot image version: 9.0.001, Release 9112P06

  Compiled Sep 21 2020 14:00:00

System image: flash:/msr1000-cmw910-system-r9112p12.bin

System image version: 9.0.001, Release 9112P06

  Compiled Sep 21 2020 14:00:00

Feature image(s) list:

  flash:/msr1000-cmw910-virtualization-r9112p12.bin, version: 9.0.001

    Compiled Sep 21 2020 14:00:00

 

Slot 0: RT-SR6602-IE uptime is 0 week, 0 day, 0 hour, 0 minute

 Last reboot reason : User reboot

 CPU ID: 2

 128G bytes DDR4 SDRAM Memory

 32M bytes Flash Memory

 PCB              Version: B

 FPGA             Version: 2.12

 Basic      CPLD  Version: 1.0

 Extend     CPLD  Version: 1.0

 Basic   BootWare Version: 1.14

 Extend  BootWare Version: 1.14

 [FIXED PORTS] CON              (Hardware)Ver.B,   (Driver)1.0,   (CPLD)1.0

 [FIXED PORTS] MGE              (Hardware)Ver.B,   (Driver)1.0,   (CPLD)1.0

 [FIXED PORTS] 6XGE             (Hardware)Ver.B,   (Driver)1.0,   (CPLD)1.0

 [FIXED PORTS] 14XGSW           (Hardware)Ver.B,   (Driver)1.0,   (CPLD)1.0

 [FIXED PORTS] 12GSW            (Hardware)Ver.B,   (Driver)1.0,   (CPLD)1.0

 

Slot 1: RT-FIP-30 uptime is 0 week, 0 day, 0 hour, 0 minute

 Last reboot reason : User reboot

 PCB              Version: A

 FPGA             Version: 3.12

 CPLD             Version: 1.0

 [FIXED PORTS] 4XGE             (Hardware)Ver.A,   (Driver)1.0,   (CPLD)1.0

 [FIXED PORTS] 16XGE            (Hardware)Ver.A,   (Driver)1.0,   (CPLD)1.0

Upgrading from the BootWare menu

You can use the following methods to upgrade software from the BootWare menu:

·         Using TFTP/FTP to upgrade software through an Ethernet port

·         Using XMODEM to upgrade software through the console port

Accessing the BootWare menu

1.         Power on the router , and you can see the following information:

System is starting...

Booting Normal Extend BootWare

The Extend BootWare is self-decompressing....Done.

 

****************************************************************************   

*                                                                          *   

*                   H3C MSR1000 BootWare, Version 1.03                     *   

*                                                                          *   

**************************************************************************** Copyright (c) 2004-2021 New H3C Technologies Co., Ltd.

 

Compiled Date       : Apr 22 2021

CPU ID              : 0x1

Memory Type         : DDR3 SDRAM

Memory Size         : 1024MB

Flash Size          : 2MB

Nand Flash size     : 256MB

CPLD Version        : 2.0

PCB Version         : 3.0

 

 

BootWare Validating...

Press Ctrl+B to access EXTENDED-BOOTWARE MENU...

2.        Press Ctrl + B to access the BootWare menu.

Password recovery capability is enabled.

Note: The current operating device is sda0

Enter < Storage Device Operation > to select device.

 

===========================<EXTEND-BOOTWARE MENU>===========================

|<1> Boot System                                                           |

|<2> Enter Serial SubMenu                                                  |

|<3> Enter Ethernet SubMenu                                                |

|<4> File Control                                                          |

|<5> Restore to Factory Default Configuration                              |

|<6> Skip Current System Configuration                                     |

|<7> BootWare Operation Menu                                               |

|<8> Skip authentication for console login                                 |

|<9> Storage Device Operation                                              |

|<0> Reboot                                                                |

============================================================================

Ctrl+Z: Access EXTENDED ASSISTANT MENU

Ctrl+F: Format File System

Enter your choice(0-9):

Table 10 BootWare menu options

Item

Description

<1> Boot System

Boot the system software image.

<2> Enter Serial SubMenu

Access the Serial submenu (see Table 13 ) for upgrading system software through the console port or changing the serial port settings.

<3> Enter Ethernet SubMenu

Access the Ethernet submenu (see Table 11) for upgrading system software through an Ethernet port or changing Ethernet settings.

<4> File Control

Access the File Control submenu (see Table 14) to retrieve and manage the files stored on the router.

<5> Restore to Factory Default Configuration

Delete the next-startup configuration files and load the factory-default configuration.

<6> Skip Current System Configuration

Start the router with the factory default configuration. This is a one-time operation and does not take effect at the next reboot. You use this option when you forget the console login password.

<7> BootWare Operation Menu

Access the BootWare Operation menu for backing up, restoring, or upgrading BootWare. When you upgrade the system software image, BootWare is automatically upgraded. H3C does not recommend upgrading BootWare separately. This document does not cover using the BootWare Operation menu.

<8> Skip authentication for console login

Clear all the authentication schemes on the console port.

<9> Storage Device Operation

Access the Storage Device Operation menu to manage storage devices. Using this option is beyond this chapter.

<0> Reboot

Restart the router.

 

Using TFTP/FTP to upgrade software through an Ethernet port

1.         Enter 3 in the BootWare menu to access the Ethernet submenu.

===============================<File CONTROL>===============================

|Note:the operating device is flash                                        |

|<1> Download Image Program To SDRAM And Run                               |

|<2> Update Main Image File                                                |

|<3> Update Backup Image File                                              |

|<4> Download Files(*.*)                                                   |

|<5> Modify Ethernet Parameter                                     |

|<0> Exit To Main Menu                                                      |

============================================================================

Enter your choice(0-4):

Table 11 Ethernet submenu options

Item

Description

<1> Download Application Program To SDRAM And Run

Download a system software image to the SDRAM and run the image.

<2> Update Main Image File

Upgrade the main system software image.

<3> Update Backup Image File

Upgrade the backup system software image.

<4> Download Files(*.*)

Download a system software image to the Flash or CF card.

<5> Modify Ethernet Parameter

Modify network settings.

<0> Exit To Main Menu

Return to the BootWare menu.

 

2.        Enter 5 to configure the network settings.

=========================<ETHERNET PARAMETER SET>=========================

|Note:       '.' = Clear field.                                            |

|            '-' = Go to previous field.                                   |

|          Ctrl+D = Quit.                                                  |

==========================================================================

Protocol (FTP or TFTP) :ftp

Load File Name         :msr1000.ipe

                       :

Target File Name       :msr1000.ipe

                       :

Server IP Address      :192.168.1.1

Local IP Address       :192.168.1.100

Subnet Mask            :255.255.255.0

Gateway IP Address     :0.0.0.0

FTP User Name          :user001

FTP User Password      :********

Table 12 Network parameter fields and shortcut keys

Field

Description

'.' = Clear field

Press a dot (.) and then Enter to clear the setting for a field.

'-' = Go to previous field

Press a hyphen (-) and then Enter to return to the previous field.

Ctrl+D = Quit

Press Ctrl + D to exit the Ethernet Parameter Set menu.

Protocol (FTP or TFTP)

Set the file transfer protocol to FTP or TFTP.

Load File Name

Set the name of the file to be downloaded.

Target File Name

Set a file name for saving the file on the router. By default, the target file name is the same as the source file name.

Server IP Address

Set the IP address of the FTP or TFTP server. If a mask must be set, use a colon (:) to separate the mask length from the IP address. For example, 192.168.80.10:24.

Local IP Address

Set the IP address of the router.

Subnet Mask

Subnet Mask of the local IP address.

Gateway IP Address

Set a gateway IP address if the router is on a different network than the server.

FTP User Name

Set the username for accessing the FTP server. This username must be the same as configured on the FTP server. This field is not available for TFTP.

FTP User Password

Set the password for accessing the FTP server. This password must be the same as configured on the FTP server. This field is not available for TFTP.

 

3.        Select an option in the Ethernet submenu to upgrade a system software image. For example, enter 2 to upgrade the main system software image.

Loading.....................................................................

............................................................................

............................................................................

.........................................Done.

37691392 bytes downloaded!

The file already exists,will you overwrite it? [Y/N]Y

Image file msr1000-cmw910-boot-r9112p12.bin is self-decompressing...

Saving file flash:/msr1000-cmw910-boot-r9112p12.bin.bin .................

Done.

Image file msr1000-cmw910-system-r9112p12.bin is self-decompressing...

Saving file flash:/msr1000-cmw910-system-r9112p12.bin.bin .................

............................................................................

...........................Done.

 

==========================<Enter Ethernet SubMenu>==========================

|Note:the operating device is sda0                                         |

|<1> Download Image Program To SDRAM And Run                               |

|<2> Update Main Image File                                                |

|<3> Update Backup Image File                                              |

|<4> Download Files(*.*)                                                   |

|<5> Modify Ethernet Parameter                                             |

|<0> Exit To Main Menu                                                     |

|<Ensure The Parameter Be Modified Before Downloading!>                    |

============================================================================

Enter your choice(0-5):

4.        Enter 0 to return to the BootWare menu

===========================<EXTEND-BOOTWARE MENU>===========================

|<1> Boot System                                                           |

|<2> Enter Serial SubMenu                                                  |

|<3> Enter Ethernet SubMenu                                                |

|<4> File Control                                                          |

|<5> Modify BootWare Password                                              |

|<6> Skip Current System Configuration                                     |

|<7> BootWare Operation Menu                                               |

|<8> Skip authentication for console login                                 |

|<9> Storage Device Operation                                              |

|<0> Reboot                                                                |

============================================================================

Enter your choice(0-9):

5.        1 to boot the system.

Loading the main image files...

Loading file flash:/msr1000-cmw910-system-e0901p01.bin..........................

Done.

Loading file flash:/msr1000-cmw910-boot-e0901p01.bin..............Done.

 

Image file flash:/msr1000-cmw910-boot-e0901p01.bin is self-decompressing.........

.....Done.

System image is starting...

Line aux0 is available.

 

 

Press ENTER to get started.

Using XMODEM to upgrade software through the console port

1.         Enter 2 in the BootWare menu to access the Serial submenu.

===========================<Enter Serial SubMenu>===========================

|Note:the operating device is sda0                                         |

|<1> Download Image Program To SDRAM And Run                               |

|<2> Update Main Image File                                                |

|<3> Update Backup Image File                                              |

|<4> Download Files(*.*)                                                   |

|<5> Modify Serial Interface Parameter                                     |

|<0> Exit To Main Menu                                                     |

============================================================================

Enter your choice(0-4):

Table 13 Serial submenu options

Item

Description

<1> Download Application Program To SDRAM And Run

Download an application to SDRAM through the serial port and run the program.

<2> Update Main Image File

Upgrade the main system software image.

<3> Update Backup Image File

Upgrade the backup system software image.

<4>Download Files(*.*)

Download a system software image to the Flash or CF card.

<5> Modify Serial Interface Parameter

Modify serial port parameters

<0> Exit To Main Menu

Return to the BootWare menu.

 

2.        Enter 5 Select an appropriate baud rate for the console port. For example, enter 5 to select 115200 bps.

===============================<BAUDRATE SET>===============================

|Note:'*'indicates the current baudrate                                    |

|     Change The HyperTerminal's Baudrate Accordingly                      |

|---------------------------<Baudrate Available>---------------------------|

|<1> 9600(Default)*                                                        |

|<2> 19200                                                                 |

|<3> 38400                                                                 |

|<4> 57600                                                                 |

|<5> 115200                                                                |

|<0> Exit                                                                  |

============================================================================

Enter your choice(0-5):

The following messages appear:

Baudrate has been changed to 115200 bps.

Please change the terminal's baudrate to 115200 bps, press ENTER when ready.

 

 

NOTE:

Typically the size of a .bin file is over 10 MB. Even at 115200 bps, the download takes about 30 minutes.

 

3.        Select Call > Disconnect in the HyperTerminal window to disconnect the terminal from the router.

Figure 2 Disconnect the terminal connection

 

 

NOTE:

If the baud rate of the console port is 9600 bps, jump to step 9.

 

4.        Select File > Properties, and in the Properties dialog box, click Configure.

Figure 3 Properties dialog box

 

5.        Select 115200 from the Bits per second list and click OK.

Figure 4 Modify the baud rate

 

6.        Select Call > Call to reestablish the connection.

Figure 5 Reestablish the connection

 

7.        Press Enter.

The following menu appears:

The current baudrate is 115200 bps

 

===============================<BAUDRATE SET>===============================

|Note:'*'indicates the current baudrate                                    |

|     Change The HyperTerminal's Baudrate Accordingly                      |

|---------------------------<Baudrate Available>---------------------------|

|<1> 9600(Default)                                                         |

|<2> 19200                                                                 |

|<3> 38400                                                                 |

|<4> 57600                                                                 |

|<5> 115200*                                                               |

|<0> Exit                                                                  |

============================================================================

Enter your choice(0-5):

8.        Enter 0 to return to the Serial submenu.

===========================<Enter Serial SubMenu>===========================

|Note:the operating device is sda0                                         |

|<1> Download Image Program To SDRAM And Run                               |

|<2> Update Main Image File                                                |

|<3> Update Backup Image File                                              |                                                        |<4> Download Files(*.*)                                                   |

|<5> Modify Serial Interface Parameter                                     |

|<0> Exit To Main Menu                                                     |

============================================================================

Enter your choice(0-4):

9.        Select an option from options 2 to 3 to upgrade a system software image. For example, enter 2 to upgrade the main system software image.

Please Start To Transfer File, Press <Ctrl+C> To Exit.

Waiting ...CCCCC

10.      Select Transfer > Send File in the HyperTerminal window.

Figure 6 Transfer menu

 

11.       In the dialog box that appears, click Browse to select the source file, and select Xmodem from the Protocol list.

Figure 7 File transmission dialog box

 

12.      Click Send. The following dialog box appears:

Figure 8 File transfer progress

 

13.      When the Serial submenu appears after the file transfer is complete, enter 0 at the prompt to return to the BootWare menu.

Download successfully!

37691392 bytes downloaded!

Input the File Name:main.bin

Updating File flash:/main.bin..............................................

.....................................................Done!

 

===========================<Enter Serial SubMenu>===========================

|Note:the operating device is sda0                                         |

|<1> Download Image Program To SDRAM And Run                               |

|<2> Update Main Image File                                                |

|<3> Update Backup Image File                                              |                                                        |<4> Download Files(*.*)                                                   |

|<5> Modify Serial Interface Parameter                                     |

|<0> Exit To Main Menu                                                     |

============================================================================

Enter your choice(0-4):

14.      Enter 1 in the BootWare menu to boot the system.

15.      If you are using a download rate other than 9600 bps, change the baud rate of the terminal to 9600 bps. If the baud rate has been set to 9600 bps, skip this step.

Managing files from the BootWare menu

To change the type of a system software image, retrieve files, or delete files, enter 4 in the BootWare menu.

The File Control submenu appears:

==============================<File CONTROL>==============================

|Note:the operating device is sda0                                       |

|<1> Display All File(s)                                                 |

|<2> Set Image File type                                                 |

|<3> Set Bin File type                                                   |

|<4> Set Configuration File type                                         |

|<5> Delete File                                                         |

|<6> Copy File                                                           |

|<0> Exit To Main Menu                                                   |

==========================================================================

Enter your choice(0-6):

Table 14 File Control submenu options

Item

Description

<1> Display All File

Display all files.

<2> Set Image File type

Change the type of a system software image (.ipe).

<3> Set Bin File type

Change the type of a system software image (.bin).

<4> Set Configuration File type

Change the type of a configuration file.

<5> Delete File

Delete files.

<6> Copy File

Copy File

<0> Exit To Main Menu

Return to the BootWare menu.

 

Displaying all files

To display all files, enter 1 in the File Control submenu:

Display all file(s) in sda0:

 'M' = MAIN      'B' = BACKUP      'N/A' = NOT ASSIGNED

============================================================================

|NO. Size(B)   Time                 Type   Name                            |

|1   37691392  May/16/2021 07:09:16 N/A    flash:/msr1000.ipe               |

|2   25992     May/16/2021 12:18:00 N/A    flash:/startup.mdb               |

|3   1632      May/16/2021 12:18:00 M      flash:/startup.cfg               |

|4   84        May/16/2021 12:17:59 N/A    flash:/ifindex.dat               |

|5   11029     May/16/2021 13:31:16 N/A    flash:/logfile/logfile1.log      |

|6   17        May/16/2021 07:47:24 N/A    flash:/.pathfile                 |

|7   1006592   May/16/2021 07:44:16 M      flash:/msr1000-cmw910-data-r9112p12.bin|

|8   815       May/16/2021 12:03:14 N/A    flash:/license/DeviceID.did           |

|9   1180672   May/16/2021 07:44:15 M      flash:/msr1000-cmw910-voice-r9112p12. bin|

|10  10240     May/16/2021 07:44:15 M      flash:/msr1000-cmw910-security-r9112p12.bin|

|11  24067072  May/16/2021 07:44:10 M      flash:/msr1000-cmw910-system-r9112p12.bin  |

|12  11418624  May/16/2021 07:44:05 M      flash:/msr1000-cmw910-boot-r9112p12.bin   |

============================================================================

Changing the type of a system software image

System software image file attributes include main (M), and backup (B). You can store only one main image, and one backup image on the router. A system software image can have any combination of the M, and B attributes. If the file attribute you are assigning has been assigned to an image, the assignment removes the attribute from that image. The image is marked as N/A if it has only that attribute.

To change the type of a system software image:

1.         Enter 2 in the File Control submenu.

'M' = MAIN      'B' = BACKUP      'N/A' = NOT ASSIGNED

============================================================================

|NO. Size(B)   Time                 Type   Name                            |

|1   37691392  May/16/2021 07:09:16 N/A    flash:/msr1000.ipe               |

|0   Exit                                                                  |

============================================================================

Enter file No:1

2.        Enter the number of the file you are working with, and press Enter.

Modify the file attribute:

==========================================================================

|<1> +Main                                                               |

|<2> +Backup                                                             |

|<0> Exit                                                                |

==========================================================================

Enter your choice(0-2):

3.        Enter a number in the range of 1 to 4 to add or delete a file attribute for the file.

Set the file attribute success!

Deleting files

When storage space is insufficient, you can delete obsolete files to free up storage space.

To delete files:

1.         Enter 5 in the File Control submenu.

Deleting the file in sda0:

 'M' = MAIN      'B' = BACKUP      'N/A' = NOT ASSIGNED

============================================================================

|NO. Size(B)   Time                 Type   Name                            |

|NO. Size(B)   Time                 Type   Name                            |

|1   37691392  May/16/2021 07:09:16 N/A    flash:/msr1000.ipe               |

|2   25992     May/16/2021 12:18:00 N/A    flash:/startup.mdb               |

|3   1632      May/16/2021 12:18:00 M      flash:/startup.cfg               |

|4   84        May/16/2021 12:17:59 N/A    flash:/ifindex.dat               |

|5   11029     May/16/2021 13:31:16 N/A    flash:/logfile/logfile1.log      |

|6   17        May/16/2021 07:47:24 N/A    flash:/.pathfile                 |

|7   1006592   May/16/2021 07:44:16 M      flash:/msr1000-cmw910-data-r9112p12.bin|

|8   815       May/16/2021 12:03:14 N/A    flash:/license/DeviceID.did      |

|9   1180672   May/16/2021 07:44:15 M      flash:/msr1000-cmw910-voice-r9112p12. bin|

|10  10240     May/16/2021 07:44:15 M      flash:/msr1000-cmw910-security-r9112p12.bin|

|11  24067072  May/16/2021 07:44:10 M      flash:/msr1000-cmw910-system-r9112p12.bin|

|12  11418624  May/16/2021 07:44:05 M      flash:/msr1000-cmw910-boot-r9112p12.bin|

0   Exit

Enter file No.:

2.        Enter the number of the file to delete.

3.        When the following prompt appears, enter Y.

The file you selected is flash:/msr1000-cmw910-security-r9112p12.bin,Delete it?

[Y/N]Y

Deleting...Done.

Handling software upgrade failures

If a software upgrade fails, the system runs the old software version. To handle a software failure:

1.         Check the physical ports for a loose or incorrect connection.

2.        If you are using the console port for file transfer, check the HyperTerminal settings (including the baud rate and data bits) for any wrong setting.

3.        Check the file transfer settings:

¡  If XMODEM is used, you must set the same baud rate for the terminal as for the console port.

¡  If TFTP is used, you must enter the same server IP addresses, file name, and working directory as set on the TFTP server.

¡  If FTP is used, you must enter the same FTP server IP address, source file name, working directory, and FTP username and password as set on the FTP server.

4.        Check the FTP or TFTP server for any incorrect setting.

5.        Check that the storage device has sufficient space for the upgrade file.

6.        If the message “Something is wrong with the file” appears, check the file for file corruption.

Appendix C Handling console login password loss

Disabling password recovery capability

Password recovery capability controls console user access to the device configuration and SDRAM from BootWare menus.

If password recovery capability is enabled, a console user can access the device configuration without authentication to configure new passwords.

If password recovery capability is disabled, console users must restore the factory-default configuration before they can configure new passwords. Restoring the factory-default configuration deletes the next-startup configuration files.

To enhance system security, disable password recovery capability.

错误!未找到引用源。 summarizes options whose availability varies with the password recovery capability setting.

Table 15 BootWare options and password recovery capability compatibility matrix

BootWare menu option

Password recovery enabled

Password recovery disabled

Tasks that can be performed

Download Image Program To SDRAM And Run

Yes

No

Load and run Comware software images in SDRAM.

Skip Authentication for Console Login

Yes

No

Enable console login without authentication.

Skip Current System Configuration

Yes

No

Load the factory-default configuration without deleting the next-startup configuration files.

Restore to Factory Default Configuration

No

Yes

Delete the next-startup configuration files and load the factory-default configuration.

 

To disable password recovery capability:

 

Step

Command

Remarks

1.       Enter system view.

system-view

N/A

2.       Disable password recovery capability.

undo password-recovery enable

By default, password recovery capability is enabled.

 

When password recovery capability is disabled, you cannot downgrade the device software to a version that does not support the capability through the BootWare menus. You can do so at the CLI, but the BootWare menu password configured becomes effective again.

Handling console login password loss

 

CAUTION

CAUTION:

Handling console login password loss causes service outage.

 

The method for handling console login password loss depends on the password recovery capability setting (see 错误!未找到引用源。).

Figure 9 Handling console login password loss

 

Examining the password recovery capability setting

7.        Reboot the router.

System is starting...

Press Ctrl+D to access BASIC-BOOTWARE MENU...

Press Ctrl+T to start heavy memory test

Booting Normal Extended BootWare........

The Extended BootWare is self-decompressing....Done.

****************************************************************************   

*                                                                          *   

*                   H3C MSR1000 BootWare, Version 1.03                     *   

*                                                                          *   

****************************************************************************

Copyright (c) 2004-2021 New H3C Technologies Co., Ltd.

 

Compiled Date       : May 13 2021

CPU ID              : 0x2

Memory Type         : DDR3 SDRAM

Memory Size         : 2048MB

BootWare Size       : 1024KB

Flash Size          : 8MB

cfa0 Size           : 247MB

CPLD Version        : 2.0

PCB Version         : 2.0

 

 

BootWare Validating...

Press Ctrl+B to access EXTENDED-BOOTWARE MENU...

8.        Press Ctrl + B within three seconds after the "Press Ctrl+B to access EXTENDED-BOOTWARE MENU..." prompt message appears.

9.        Read the password recovery capability setting information displayed before the EXTEND-BOOTWARE menu.

Password recovery capability is enabled.

Note: The current operating device is sda0

Enter < Storage Device Operation > to select device.

 

===========================<EXTEND-BOOTWARE MENU>===========================

|<1> Boot System                                                            |

|<2> Enter Serial SubMenu                                                   |

|<3> Enter Ethernet SubMenu                                                 |

|<4> File Control                                                           |

|<5> Restore to Factory Default Configuration                               |

|<6> Skip Current System Configuration                                      |

|<7> BootWare Operation Menu                                                |

|<8> Skip Authentication for Console Login                                  |

|<9> Storage Device Operation                                               |

|<0> Reboot                                                                 |

============================================================================

Ctrl+Z: Access EXTEND ASSISTANT MENU

Ctrl+F: Format File System

Enter your choice(0-9):

Using the Skip Current System Configuration option

10.      Reboot the router to access the EXTEND-BOOTWARE menu, and then enter 6.

The current mode is password recovery.

Note: The current operating device is sda0

Enter < Storage Device Operation > to select device.

 

===========================<EXTEND-BOOTWARE MENU>===========================

|<1> Boot System                                                            |

|<2> Enter Serial SubMenu                                                   |

|<3> Enter Ethernet SubMenu                                                 |

|<4> File Control                                                           |

|<5> Restore to Factory Default Configuration                               |

|<6> Skip Current System Configuration                                      |

|<7> BootWare Operation Menu                                                |

|<8> Skip Authentication for Console Login                                  |

|<9> Storage Device Operation                                               |

|<0> Reboot                                                                 |

============================================================================

Ctrl+Z: Access EXTEND ASSISTANT MENU

Ctrl+F: Format File System

Enter your choice(0-9): 6

After the configuration skipping flag is set successfully, the following message appears:

Flag Set Success.

11.       When the EXTEND-BOOTWARE menu appears again, enter 1 to reboot the router.

The router starts up with the factory-default configuration without deleting the next-startup configuration files.

12.      To use the configuration in a next-startup configuration file, load the file in system view.

<H3C> system-view

[H3C] configuration replace file flash:/startup.cfg

Current configuration will be lost, save current configuration? [Y/N]:n

Info: Now replacing the current configuration. Please wait...

Info: Succeeded in replacing current configuration with the file startup.cfg.

13.      Configure a new console login authentication mode and a new console login password.

In the following example, the console login authentication mode is password and the authentication password is 123456. For security purposes, the password is always saved in ciphertext, whether you specify the simple or cipher keyword for the set authentication password command.

<H3C> system-view

[H3C] line console 0

[H3C-line-console0] authentication-mode password

[H3C-line-console0] set authentication password simple 123456

Use the line console 0 command on an Msr1000 router. The console port and the Console port are the same physical port.

14.      To make the settings take effect after a reboot, save the running configuration to the next-startup configuration file.

[H3C-line-console0] save

Using the Skip Authentication for Console Login option

15.      Reboot the router to access the EXTEND-BOOTWARE menu, and then enter 8.

The current mode is password recovery.

Note: The current operating device is sda0

Enter < Storage Device Operation > to select device.

 

===========================<EXTEND-BOOTWARE MENU>===========================

|<1> Boot System                                                            |

|<2> Enter Serial SubMenu                                                   |

|<3> Enter Ethernet SubMenu                                                 |

|<4> File Control                                                           |

|<5> Restore to Factory Default Configuration                               |

|<6> Skip Current System Configuration                                      |

|<7> BootWare Operation Menu                                                |

|<8> Skip Authentication for Console Login                                  |

|<9> Storage Device Operation                                               |

|<0> Reboot                                                                 |

============================================================================

Ctrl+Z: Access EXTEND ASSISTANT MENU

Ctrl+F: Format File System

Enter your choice(0-9): 8

The router deletes the console login authentication configuration commands from the main next-startup configuration file. After the operation is completed, the following message appears:

Clear Image Password Success!

16.      When the EXTEND-BOOTWARE menu appears again, enter 1 to reboot the router.

The router starts up with the main next-startup configuration file.

17.      Configure a console login authentication mode and a new console login password. See

"Configure a new console login authentication mode and a new console login password.."

18.      To make the setting take effect after a reboot, save the running configuration to the next-startup configuration file.

[H3C-line-console0] save

Using the Restore to Factory Default Configuration option

 

CAUTION

CAUTION:

Using the Restore to Factory Default Configuration option deletes both the main and backup next-configuration files.

 

19.      Reboot the router to access the EXTEND-BOOTWARE menu, and enter 5.

The current mode is no password recovery.

Note: The current operating device is sda0

Enter < Storage Device Operation > to select device.

 

===========================<EXTEND-BOOTWARE MENU>===========================

|<1> Boot System                                                            |

|<2> Enter Serial SubMenu                                                   |

|<3> Enter Ethernet SubMenu                                                 |

|<4> File Control                                                           |

|<5> Restore to Factory Default Configuration                               |

|<6> Skip Current System Configuration                                      |

|<7> BootWare Operation Menu                                                |

|<8> Skip Authentication for Console Login                                  |

|<9> Storage Device Operation                                               |

|<0> Reboot                                                                 |

============================================================================

Ctrl+Z: Access EXTEND ASSISTANT MENU

Ctrl+F: Format File System

Enter your choice(0-9): 5

20.      At the prompt for confirmation, enter Y.

The router deletes its main and backup next-startup configuration files and restores the factory-default configuration.

The current mode is no password recovery. The configuration files will be

deleted, and the system will start up with factory defaults, Are you sure to

 continue?[Y/N]Y

Setting...Done.

21.      When the EXTEND-BOOTWARE menu appears again, enter 1 to reboot the router.

The router starts up with the factory-default configuration.

22.      Configure a new console login authentication mode and a new console login password. See

"Configure a new console login authentication mode and a new console login password.."

23.      To make the settings take effect after a reboot, save the running configuration to the next-startup configuration file.

[H3C] save

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Intelligent Storage
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
  • Technical Blogs
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us