12端口10/100/1000Base-T + 4端口1000Base-X(SFP)千兆以太网业务板-LS81T12PE
1 单板标识
前面板右上角标有丝印LS81T12PE,用来标识该单板。
2 单板简介
此单板可以作为S7502交换机的交换路由板或业务板,也可以作为S7503/S7506/ S7506R交换机的业务板。
表-1 LS81T12PE属性
属性 | LS81T12PE |
交换容量 | 48Gbit/s |
包交换率 | 36Mpps |
MAC地址表 | 16K |
IP地址表 | 64K |
接口连接器类型 | RJ-45、LC |
对外接口 | l 12个10/100/1000Base-T千兆以太网端口 l 4个1000Base-X(SFP)千兆以太网接口 |
接口传输速率 | l 1000 Mbit/s全双工(光口) l 10/100/1000 Mbit/s半/全双工(电口) |
以太网端口可选用线缆及最大传输距离 | 5类双绞线,传输距离100m |
单板适用的主机类型 | l S7502交换机(交换路由板或业务板) l S7503、S7506和S7506R交换机(业务板) |
单板适用的主机软件版本 | Release 3000系列/Release 3100系列 |
可选用的SFP模块类型及其属性见下表。
表-2 SFP模块属性
SFP模块名称 | 中心波长 | 接口连接器类型 | 接口光纤规格 | 光纤最大传输距离 |
SFP-GE-SX-MM850-A | 850nm | LC | 50µm/125µm多模光纤 | 550m |
62.5µm/125µm多模光纤 | 275m | |||
SFP-GE-LX-SM1310-A | 1310nm | LC | 9µm/125µm单模光纤 | 10km |
SFP-GE-LH40-SM1310 | 40km | |||
SFP-GE-LH40-SM1550 | 1550nm | LC | 9µm/125µm单模光纤 | 40km |
SFP-GE-LH70-SM1550 | 70km | |||
SFP-GE-LH100-SM1550 | 100km | |||
SFP-GE-LH70-SM1470-CW | 1470nm | 70km | ||
SFP-GE-LH70-SM1490-CW | 1490nm | |||
SFP-GE-LH70-SM1510-CW | 1510nm | |||
SFP-GE-LH70-SM1530-CW | 1530nm | |||
SFP-GE-LH70-SM1550-CW | 1550nm | |||
SFP-GE-LH70-SM1570-CW | 1570nm | |||
SFP-GE-LH70-SM1590-CW | 1590nm | |||
SFP-GE-LH70-SM1610-CW | 1610nm | |||
SFP-GE-T | - | RJ-45 | - | 100m |
3 注意事项
l 如主机软件版本不匹配,可以联系该设备的销售商或集成商获取相应的主机软件版本。
l 单板安装说明及主机软件版本的升级方法请参见《H3C S7500系列以太网交换机 安装手册》和《H3C S7502以太网交换机 安装手册》相关章节。
l 单板种类或规格可能随产品版本的变更而改变,请从公司网站http://www.h3c.com.cn主页上的“文档中心”获取最新资料。
杭州华三通信技术有限公司
12-port 10/100/1000Base-T + 4-port 1000Base-X (SFP) Ethernet Card - LS81T12PE
1 Card Identifier
The silkscreen LS81T12PE is printed at the upper right corner of the front panel, and is used to identify the card.
2 Specifications
This card can serve as the switching and routing process unit (SRPU or LPU) of the S7502 switch or the Line Processing Unit (LPU) of the S7503/S7506/S7506R switch.
Table1 LS81T12PE specifications
Item | LS81T12PE |
Switching capacity | 48 Gbps |
Packet forwarding rate | 36 Mpps |
MAC address table | 16K |
IP address table | 64K |
Connector | RJ-45, LC |
Port | l 12 ´ 10/100/1000Base-T Ethernet ports l Four 1000Base-X (SFP) ports |
Interface transmission speed | 1000 Mbps full-duplex (optical) 10/100/1000 Mbps half-/full-duplex (electrical) |
Electrical interface cable and max transmission distance | Category-5 twisted pair with maximum transmission distance of 100 m (328 ft) |
Applied to | l S7502 Ethernet Switch (SRPU or LPU) l S7503/S7506/S7506R Ethernet Switch (LPU) |
Host software version | Release 3000 series/Release 3100 series |
For supported SFP modules, refer to the following table.
Table2 SFP module attribute
SFP module | Central wavelength | Connector | Matching cable | Maximum transmission distance |
SFP-GE-SX-MM850-A | 850 nm | LC | 50/125 µm multimode optical fiber cable | 550 m (1804 ft) |
62.5/125 µm multimode optical fiber cable | 275 m (902 ft) | |||
SFP-GE-LX-SM1310-A | 1310 nm | LC | 9/125 µm single mode optical fiber cable | 10 km (6 mi) |
SFP-GE-LH40-SM1310 | 40 km (about 25 mi) | |||
SFP-GE-LH40-SM1550 | 1550 nm | LC | 9/125 µm single mode optical fiber cable | 40 km (about 25 mi) |
SFP-GE-LH70-SM1550 | 70 km (43 mi) | |||
SFP-GE-LH100-SM1550 | 100 km (62 mi) | |||
SFP-GE-LH70-SM1470-CW | 1470 nm | LC | 9/125 µm single mode optical fiber cable | 70 km (43 mi) |
SFP-GE-LH70-SM1490-CW | 1490 nm | |||
SFP-GE-LH70-SM1510-CW | 1510 nm | |||
SFP-GE-LH70-SM1530-CW | 1530 nm | |||
SFP-GE-LH70-SM1550-CW | 1550 nm | |||
SFP-GE-LH70-SM1570-CW | 1570 nm | |||
SFP-GE-LH70-SM1590-CW | 1590 nm | |||
SFP-GE-LH70-SM1610-CW | 1610 nm | |||
SFP-GE-T | — | RJ-45 | — | 100 m (328 ft) |
3 Note
l If the host software version does not match the one applicable to the card, contact the vendor or the integrator for the right version.
l For the introduction of card installation and host software upgrade, see the related part in H3C S7500 Series Ethernet Switches Installation Manual and H3C S7502 Ethernet Switch Installation Manual.
l As board types or specifications might change with product versions, you may need to obtain the latest documents from Technical Support & Document link on H3C website http://www.h3c.com.
Hangzhou H3C Technologies Co., Ltd