Country / Region
H3C S10500X-G is a high-end Switch series designed for the core layer in intelligent Campuses and cloud computing Data Centers. Powered by the H3C COMWARE 7 network operating system, the S10500X-G offers a comprehensive set of features tailored to both campus and data center environments, providing a secure and flexible platform for diverse types of network traffic. Architecturally, the S10500X-G adopts an industry-leading orthogonal CLOS+ forwarding architecture, ensuring long-term networking capabilities, making S10500X-G capable of building a high-performance network for years to come. In terms of services, with PoE++ capability, EERN (Enhanced Ethernet Ring Network) technology, and a variety of GE/10GE/25GE/40GE/100GE/400GE cards, along with wireless AC module, S10500X-G provides complete solutions for a wide range of scenarios. To ensure the network operating continuity, the S10500X-G delivers carrier-level reliability, features redundant designs across key components including the Engine units (MPU), Switch Fabric units, fan trays, and power supply modules. Additionally, the S10500X-G embraces a Green and environmentally friendly design philosophy, with intelligent cooling system and reduced power consumption to promote energy efficiency.
The S10500X-G series includes several different chassis models, S10506X-G, S10508X-G and S10512X-G, with different port density and performance to fit different network scales.
The following contents are complex, and it is recommended to browse on PC.
Enter c.h3c.com.cn on the PC browser and operate according to the page to synchronize to the PC and continue browsing.
Continue by mobile
S10500X-G incorporates the following advanced designs:
CLOS+ architecture and non-backplane design: Data center level forwarding architecture, separates the forwarding plane and control plane completely and high level of bandwidth scalability, building a non-blocking campus network.
Orthogonal interconnection of switching fabric modules and service card modules eliminates circuit on the backplane and thus significantly reduces signal attenuation and data transmit latency.
Compact chassis design, smaller, lighter, take S10506X-G for instance, hosts 6 line-card slots in 10U high-performance CLOS+ switch, which can also fit in a regular 600mm depth rack cabinet, greatly saving rack cabinet space.
With Data center-level forwarding architecture, non-backplane Orthogonal CLOS+, providing slot bandwidth up to 3.1Tbps (bidirectional) on S10506X-G/S10506X-G-PoE and 4.6Tbps (bidirectional) on S10508X-G/S10512X-G.
Compliant with 40G,100G and 400G Ethernet standards, high port-density 40G, 100G line cards to build a high-speed network. The S10500X-G takes the lead in 400G Campus scenario, dramatically increases the inter-campus bandwidth, eliminates bandwidth bottleneck, also makes S10500X-G suitable for Date center scenario in the era of AI.
S10500X-G EERN solution (Enhanced Ethernet Ring Network): H3C EERN Hardware Ring network technology provides the most optimal proposal to build long distance Ring structure networks. Ring structure is widely adopted in Transportation, Metro, Railway and Manufacturing industries. Compared to other software Ring protocols, such as RRPP, ERPS, the bandwidth of EERN is much higher, with each ring being a 200G ring and the distance between two sites can be as far as 80KM, and the switchover time is much faster, being less than 3ms. As EERN is running on 1.5 layer, so typical Ethernet protocols can run on EERN. With EERN, customers will no longer need to relay on WAN system to build a long-distance ring network for their business, EERN can be their new and most cost-effective solution.
Thorough system optimization enables S10500X-G to forward traffic within 100 seconds after being powered on, greatly reducing service interruption time.
Large entries cards: with max Mac and Route being larger than 700K, to meet the customers’ high requirements of all kinds of networks.
Ultra-low forwarding latency: can be as less as <1µs to ensure a fluent use experience.
S10500X-G series adopts distributed system design for control engines, detection engines, and maintenance engines to deliver powerful control capability and millisecond-level HA.
Distributed control engines: Each service card is integrated with a control and processing system. It can efficiently process varieties of packets on the control plane, and provide precise control for protocol packets to avoid attacks on the control plane.
Distributed detection engines: Each service card can deploy BFD or OAM to detect faults in milliseconds and interact with control plane protocols for fast failover and convergence to ensure service continuity.
Distributed maintenance engines: The intelligent CPU system supports intelligent power management and status monitoring for key components. It can reduce power impulse, electromagnetic radiation, and power consumption, and prolongs the device lifespan.
S10500X-G Multigigabit Ethernet PoE++ Solution:With 48*10G Multigigabit PoE++ card, S10500X-G can provide an Easy-to-Deploy solution that can grow with customers’ business. It brings 5 times the current speed to the workspace in a way that plugs right into the existing cabling infrastructure, upgrades network capacity without disruption to business, delivers 15W, 30W, 60W and up to 90W (802.3bt standard) PoE out, powering more end-devices – IP phones, IPTVs, cameras, etc.
256bits MACsec capability: MACsec is an industry-standard point-to-point link-level security technology, is supported on all ports on SF card to provide comprehensive Link level security solution, protecting the network from security threats on the deepest data level.
Trusted Computing: With the built-in TPM, S10500X-G brings the security degree of switches to another level, providing multiple features, such as certificate issuance and device self-check functions to build a more secured network.
3ms Hardware BFD: to ensure the network continuity.
M-LAG (Multichassis link aggregation, originated from DRNI): provides device-level redundancy and load-balance through the simplest link aggregation protocol.
IRF2 (Intelligent Resilient Framework): device level reliability technology, virtualizes multiple switches into one virtual IRF system to provide Data Center-class availability, scalability and also simplifies the management complexity. IRF2 system can be formed over a distance of 80 km (49.71 miles).
Supports a variety of high-availability features such as NSF, ISSU, Graceful Restart, Smartlink, etc.
Redundancy design across key components, including MPUs, switch Fabric Units, Fan tray, PSUs, even power switches, maximizing the system availability and guarding the device against emergency and unexpected conditions.
All modules and power supplies are hot swappable.
H3C S10500X-G series can operate in extreme environment reliably for a long time, with a carrier-level reliability of 99.999%.
Embedded NMS Platform (SmartMC) to provide a light-weight, convenient network management solution.
Compatible with both H3C Intelligent SDN campus network solution (AD-Campus) and SDN date center network solution (AD-DC) to build a SDN network with high-level automation, intelligence.
Supports Visualization technologies, INT, gRPC, Netstream, Telemetry Stream, etc.
Complete IPv4/IPv6 dual stack solutions: IPv6 static routing, RIPng, OSPFv3, IS-ISv6, BGP4+ and Pv4/IPv6 multicast.
IPv4-to-IPv6 transition: IPv6 manual tunnel, 6to4 tunnel, ISATAP tunnel, GRE tunnel, and IPv4-compatible automatic tunnel configuration.
H3C S10500X-G has obtained IPv6 ready logo (phase 2), strong evidence that S10500X-G is a mature series ready for commercial IPv6 services.
Strict Front-to-Rear Air Flow: S10500X-G adopts the best heat dissipation design, reducing the mutual airflow resistance between different switches next to each other in the server room to a great degree.
Higher energy efficiency: PSUs of S10500X-G support 10A power supply input, greatly reducing the requirements for the power supply system in server rooms. Behind that, the overall power consumption is much lower thanks to the high power-efficiency features, such as 2-level power supply structure.
Intelligent Cooling system, the fan tray supports intelligent speed adjustment based on real-time temperature monitoring points embedded in the chassis, the speed of the fan is dynamically adjusted to keep the optimal balance between the heat dissipation and power consumption, saving power consumption significantly.
Water-based paint without electroplating for the chassis exterior significantly reduces carbon emissions.
Features | S10506X-G S10506X-G-PoE | S10508X-G | S10512X-G |
Switching capacity | 43.2Tbps/76.8Tbps* | 57.6Tbps/153.6Tbps* | 86.4Tbps/230.4Tbps* |
Forwarding capacity | 19200Mpps | 25600Mpps | 68400Mpps |
MPU slots | 2 | ||
MPU Console Ports | 1x RJ-45 | 1x RJ-45 | 1x RJ-45 |
MPU MGMT Ports | 1x 10/100/1000M RJ-45 1x 1000M SFP | 1x 10/100/1000M RJ-45 1x 1000M SFP | 1x 10/100/1000M RJ-45 1x 1000M SFP |
MPU USB Port | 1 | 1 | 1 |
LPU slots | 6 | 8 | 12 |
Switching fabric module slots | 4 | 6 | 6 |
Fan Trays | 2 | 3 | 3 |
Power modules | 4 (non- PoE)+8 (PoE) | 6 | 8 |
Hardware architecture | Orthogonal CLOS | ||
Redundancy | Redundant MPUs, switching fabric modules, power modules, and fan trays | ||
Operating environment | Temperature: 0℃ to 45℃ (32°F to 113°F) Humidity: 5% to 95% (non-condensing) | ||
Input voltage | AC:100V~240V DC:-48V~-60V | ||
Maximum power consumption | 3012W | 4374W | 6309W |
MTBF(Year) | 36.5 | 27.05 | 21 |
MTTR(Hour) | 0.5 | 0.5 | 0.5 |
Dimension (H x W x D)/mm | 442×440×520 10U | 530×440×640 12RU | 796×440×640 18RU |
Fully loaded weight | S10506X-G: < 85 kg/187.4 lb S10506X-G-PoE: < 95 kg/209lb | < 130 kg < 286.6 lb | < 180 kg < 396.8 lb |
Switching capacity *: The value marked with * after (/) represents the capacity the chassis backplane is ready to support.
Feature | S10500X-G switch series |
Ethernet | IEEE 802.1Q VLAN (up to 4K VLANs and 4K VLAN interfaces) DLDP LLDP Static MAC configuration Limited MAC learning Port mirroring and traffic mirroring Mirroring, SPAN, RSPAN, ERSPAN with Max. 128 mirror groups Port aggregation,LACP, port isolation, and port mirroring 802.1d(STP)/802.1w(RSTP)/802.1s(MSTP)/PVST/PVST+ Up to 64 MSTP instances Up to 126 PVST/PVST+ instances STP Root Guard BPDU Guard, BPDU filter IEEE 802.3ad (dynamic link aggregation), static port aggregation, and multi-chassis link aggregation IEEE 802.1P (CoS priority) IEEE 802.1ad (QinQ), selective QinQ and Vlan mapping GVRP RRPP (Rapid Ring Protection Protocol) Jumbo frame (13312) SuperVLAN PVLAN Guest VLAN Voice VLAN MVRP(IEEE802.1ak) Broadcast/multicast/unknown unicast storm constrain Port-based, Protocol-based, Subnet-based and MAC-based VLAN Max. 720,896 MAC entries |
Routing | Static routing, RIPv1/v2, OSPF, IS-IS, and BGP4 ARP proxy ARP snooping DHCP client, DHCP server, DHCP relay, DHCP snooping, DHCP option82 DHCPv6 client, DHCPv6 server, DHCPv6 relay, DHCPv6 snooping, DHCPv6 option82 Max. 16K DHCP-security users IPv4/IPv6 ECMP IPv4/IPv6 Policy-based routing IPv4/IPv6 Routing policy IPv4/IPv6 dual stack IPv6 static routing, RIPng, OSPFv3, IS-ISv6, and BGP4+ Pingv6, Telnetv6, FTPv6, TFTPv6, DNSv6, ICMPv6 IPv4-to-IPv6 transition technologies, such as IPv6 manual tunnel, 6to4 tunnel, ISATAP tunnel, GRE tunnel、IPv4-compatible IPv6 tunnel Max. 96,230 ARP entries Max. 81,350 ND entries Max. 780,288 IPV4 routing entries Max. 278,528 IPV6 routing entries |
Multicast | PIM-DM, PIM-SM, PIM-SSM, MSDP, MBGP, and Any-RP IGMP V1/V2/V3、IGMP V1/V2/V3 Snooping IGMP Filter and IGMP Fast leave PIM snooping, IPv6 Pim-snooping Multicast VLAN PIM6-DM、PIM6-SM、PIM6-SSM MLD V1/V2, MLD V1/V2 Snooping Multicast policy and Multicast QoS Max. 8K L2 multicast entries Max. 8K L3 multicast entries |
ACL/QoS | Standard and extended ACLs Ingress and Egress ACL VLAN ACL Global ACL Ingress/Egress CAR Diff-Serv QoS 802.1P/DSCP Priority marking and remarking 802.1p, TOS, DSCP, and EXP priority mapping Flexible queue scheduling algorithms including SP, WRR, SP+WRR, WFQ Traffic shaping Congestion avoidance, Tail-Drop and WRED Ingress/Egress counting COPP Max. 36MB Buffer Max. 26K IPv4 ACL Max. 8K IPv6 ACL |
SDN/OPENFLOW | Support SDN solution (AD-Campus) OpenFlow 1.3 Multiple controllers (EQUAL, master/slave) Multiple tables flow Group table Meter |
VXLAN | VXLAN L2 switching VXLAN L3 routing VXLAN VTEP L2 VxLAN gateway, L3 VxLAN gateway Distributed VxLAN gateway, Centrilized VxLAN gateway IPv4/IPv6 VxLAN tunnel VXLAN OAM ping/tracert IS-IS+ENDP distributed control plane MP-BGP+EVPN distributed control plane, EVPN-DCI EVPN ES OpenFlow+Netconf centralized control plane |
Programmability and automation | Ansible Auto DevOps by using Python, NETCONF, TCL, and Restful APIs for automated network programming |
Lossless Ethernet | PFC ECN RoCEv2 |
MPLS/VPLS | L3 MPLS VPN L2 VPN: VLL (Martini, Kompella) MCE MPLS OAM VPLS, VLL P/PE function LDP |
Multiservice Convergence | Integrated AC, Unified Wireless Access Controller, (LSEM1SUPA0, LSEM1SUPB0 support integrated AC) AP Auto Registration Wireless User WPA2 + PSK Authentication Wireless User Portal Authentication |
Security | Hierarchical user management and password protection EAD Port security Portal authentication MAC authentication IEEE 802.1x and IEEE 802.1x SERVER AAA/Radius TACACS+ HWTACACS (HW Terminal Access Controller Access Control System) (Same authentication processes and implementations with TACACS+) SSHv1.5/SSHv2 Basic and advanced ACLs for packet filtering OSPF, RIPv2, BGPv4 plain text and MD5 authentication IP address, VLAN ID, MAC address multiple binding combination MACsec uRPF HTTPS SSL PKI Secure boot TPM, Trust computing Active/standby data backup Micro-segmentation |
System management | IMC network management system Loading and upgrading through XModem/FTP/TFTP SNMP v1/v2c/v3 SmartMC sFlow, Netstream Telemetry INT MOD (Mirror on drop) Packet capture gRPC Telemetry Stream RMON and groups 1,2,3 and 9 NTP and PTP (1588v2) NQA, iNQA Fault alarm and automatic fault recovery System logs ZTP Ping, Tracert, VxLAN ping and VxLAN tracert eMDI Cloud management Device status monitoring mechanism, including the CPU engine, backplane, chips and other key components |
HA | Independent switching fabric modules 1+1 redundancy for key components such as MPUS and M+N redundancy for power modules N+1 redundancy for switching fabric modules Passive backplane Hot swapping for all components Real-time data backup on active/standby MPUs CPU protection IP source guard Loop detection Ethernet OAM VRRP, VRRPv3 Hot patching NSR/GR for OSPF/BGP/IS-IS/RSVP Port aggregation and multi-card link aggregation, LACP BFD for VRRP, BGP/BGPv4, IS-IS/IS-ISv6, PIM/PIM for IPV6, OSPF/OSPFv3, RSVP, static routing, with a failover detection time less than 50 milliseconds Hardware BFD Ethernet QAM (802.1ag and 802.3ah) RRPP/ERPS/EERN VCT Track Monitor Link Smart-Link IRF ISSU M-LAG S-MLAG MDC Loopback Detection |
Green | IEEE (802.3az) |
EMC | FCC Part 15 Subpart B CLASS A ICES-003 CLASS A VCCI CLASS A CISPR 32 CLASS A EN 55032 CLASS A AS/NZS CISPR32 CLASS A CISPR 24 EN 55024 EN 61000-3-2 EN 61000-3-3 ETSI EN 300 386 |
Safety | UL 60950-1 CAN/CSA C22.2 No 60950-1 IEC 60950-1 EN 60950-1 AS/NZS 60950-1 FDA 21 CFR Subchapter J GB 4943.1 |
*The contents are applicable only to regions outside Greater China.
Product ID | Product Description |
Chassis | |
LS-10506X-G | H3C S10506X-G Ethernet Switch Chassis |
LS-10506X-G-PoE | H3C S10506X-G Ethernet Switch Chassis, PoE |
LS-10508X-G | H3C S10508X-G Ethernet Switch Chassis |
LS-10512X-G | H3C S10512X-G Ethernet Switch Chassis |
Power Supply Module | |
PSR1600B-12A-B | 1600W AC Power Supply Module (Power Panel Side Exhaust Airflow) |
PSR2000-12D-B | 2000W DC Power Supply Module(Power Panel Side Exhaust Airflow) |
PSR1600-54A-B | 1600W/56V PoE Power Supply Module (Power Panel Side Exhaust Airflow) |
Fan Tray Module | |
FAN-80B-4-A | Fan Tray Module |
FAN-80B-5-A | Fan Tray Module |
FAN-80B-8-A | Fan Tray Module |
Supervisor Engine | |
LSEM1SUPA0 | H3C S10500X-G Supervisor Engine Unit,Type A |
LSEM3SUPA0 | H3C S10500X-G Supervisor Engine Unit,Type A |
LSEM1SUPB0 | H3C S10512X-G Supervisor Engine Unit,Type B |
LSEM3SUPB0 | H3C S10512X-G Supervisor Engine Unit,Type B |
Switch Fabric Unit | |
LSEM1SF06D0 | H3C S10506X-G Switch Fabric Module,Type D |
LSEM1SF08C0 | H3C S10508X-G Switch Fabric Module,Type C |
LSEM1SF12B0 | H3C S10512X-G Switch Fabric Module,Type B |
LSEM1SF06B0 | H3C S10506X-G Switch Fabric Module,Type B |
Line Card | |
LSEM1GT48TSSD0 | H3C S10500X-G 48-Port 10/100/1000BASE-T Interface(RJ45)+4-Port 10G Ethernet Optical Interface Module (SFP+,LC)(SD) |
LSEM1GV48TSSD0 | H3C S10500X-G 48-Port 10/100/1000BASE-T Interface(RJ45)+4-Port 10G Ethernet Optical Interface Module (SFP+)(SD),PoE Plus |
LSEM1GT24GP16TSSD0 | H3C S10500X-G 24-Port 10/100/1000BASE-T Ethernet Copper Interface(RJ45)+16-Port 1000BASE Ethernet Optical Interface(SFP)+12-Port 10G Ethernet Optical Interface Module (SFP+)(SD) |
LSEM2TGS16GP32SD0 | H3C S10500X-G 16-Port 10G Ethernet Optical Interface(SFP+) + 32-Port 1000BASE Ethernet Optical Interface Module (SFP)(SD) |
LSEM1TGS24SD0 | H3C S10500X-G 24-Port 10G Ethernet Optical Interface Module (SFP+,LD)(SD) |
LSEM1TGS48QSSF0 | H3C S10500X-G 48-Port 10G Ethernet Optical Interface(SFP+,LC)+4-Port 40G Ethernet Optical Interface Module (QSFP+)(SF) |
LSEM3TGS48QSSF0 | H3C S10500X-G 48-Port 10G Ethernet Optical Interface(SFP+) + 4-Port 40G Ethernet Optical Interface Module (QSFP+)(SF) |
LSEM1TGT48SD0 | H3C S10500X-G 48-Port Multigigabit Ethernet (10G/5G/2.5G/1G/100Mbps) Copper Interface Module (RJ45)(SD) |
LSEM1TGV48SD0 | H3C S10500X-G 48-Port Multigigabit (10G/5G/2.5G/1G/100Mbps) Ethernet Copper Interface Module (RJ45)(SD),Separate License Required for 10G/5G,PoE++ |
LSEM2TGS48SD0 | H3C S10500X-G 48-Port 10G Ethernet Optical Interface Module (SFP+)(SD) |
LSEM1YGS48CQSF0 | H3C S10500X-G 48-Port 25G Ethernet Optical Interface (SFP28)+4-Port 100G Ethernet Optical Interface Module (QSFP28)(SF) |
LSEM3YGS48CQSF0 | H3C S10500X-G 48-Port 25G Ethernet Optical Interface (SFP28) + 4-Port 100G Ethernet Optical Interface Module (QSFP28)(SF) |
LSEM1QGS16SF0 | H3C S10500X-G 16-Port 40G Ethernet Optical Interface Module (QSFP+)(SF) |
LSEM3QGS16SF0 | H3C S10500X-G 16-Port 40G Ethernet Optical Interface Module (QSFP+)(SF) |
LSEM1QGS36SF0 | H3C S10500X-G 36-Port 40G Ethernet Optical Interface Module (QSFP+)(SF) |
LSEM3QGS36SF0 | H3C S10500X-G 36-Port 40G Ethernet Optical Interface Module (QSFP+)(SF) |
LSEM1GT48TS24QSSD0 | H3C S10500X-G 48-Port 10/100/1000BASE-T Ethernet Copper Interface(RJ45)+24-Port 10G Ethernet Optical Interface(SFP+)+2-Port 40G Ethernet Optical Interface Module (QSFP+)(SD) |
LSEM1CGQ16SF0 | H3C S10500X-G 16-Port 100G Ethernet Optical Interface Module (QSFP28)(SF) |
LSEM3CGQ16SF0 | H3C S10500X-G 16-Port 100G Ethernet Optical Interface Module (QSFP28)(SF) |
LSEM1CGQ36SF0 | H3C S10500X-G 36-Port 100G Ethernet Optical Interface Module (QSFP28)(SF) |
LSEM3CGQ36SF0 | H3C S10500X-G 36-Port 100G Ethernet Optical Interface Module (QSFP28)(SF) |
LSEM1CDQ2SF0 | H3C S10500X-G 2-Port 400G Ethernet Optical Interface Module (QSFP-DD)(SF) |
LSEM3CDQ2SF0 | H3C S10500X-G 2-Port 400G Ethernet Optical Interface Module (QSFP-DD)(SF) |
LSEM1RCGQ2TSSF0 | H3C S10500X-G 2-Port 100G RPR Optical Interface(QSFP28)+16-Port 10G Ethernet Optical Interface Module (SFP+)(SF) |