| Server Name | Version | Category | OS | OS Subclass | Publish Date | Operate | |
| NIC-ETH531F-3S-2P | 234.1.124.0.00 | Firmware | N/A | N/A | 2025/12/31 |
|
|
Version
234.1.124.0.00
File Name
Firmware Release Notes.pdf(65.54 KB) fw-nic-broadcom-H3C-BCMCD(234.1.124.0.00).zip(79.44 MB)
Description
The software is the firmware upgrade program for Broadcom H3C-BCMCD network card version 234.1.124.0.00.
Problems Solved
1.Fixed the issue of Niccli recovery failure after resetting from damaged firmware (DCSG-41552); 2.Fixed communication issue after firmware update when enabling software untag VLAN (DCSG-41528); 3.Fixed the issue where the PLDM firmware update did not display the image to be updated when the versions of the active and pending images were the same (DCSG-40211); 4.Fixed the issue where the latest PLDM time could not be sent to BMC (DCSG-37593); 5.Fixed an issue where sending PCIe VDM MCTP messages too early could cause the system to hang (DCSG-18324); 6.Fixed the GPIO multiplexing value of OCP Chain pins so that they can be mapped and correctly used for temperature warnings (DCSG-31638); 7.Fixed the fastboot recovery issue where fastboot recovery (DCSG-30725) is not allowed when lockdown is enabled; 8.Fixed the issue where the temperature of the transceiver read from eeprom was good, but the is_tempnvalid flag indicated that it was invalid (DCSG-29165); 9.Fixed LLDP forwarding issue, now always forwarding LLDP packets to BMC (DCSG-29361); 10.Fixed the issue of not being able to obtain DHCP IP in VM (DCSG-13760); 11.If DCBX is enabled on the NCSI path, LLDP disable request (DCSG-3220) is rejected. 12.Whp: Mgmt:To prevent firmware crashes due to a full FIFO (First In, First Out) buffer, using a microsecond timer to adjust timeout calculations can be employed (DCSG-01769683). 13.The task of periodically updating the heartbeat will be delegated to other processes to prevent firmware crashes.
Products
- H3C UniServer R4700 G7
- H3C UniServer R4900LE G6 Ultra
- H3C UniServer R5350 G6
- H3C UniServer R5500 G5 HYGON
- H3C UniServer R4950 G5
- H3C UniServer R4300 G5
- H3C UniServer B5700 G5
- H3C UniServer R8900 G3
- H3C UniServer R2900 G3
- H3C UniServer E3200 G3
- H3C UniServer R4500 G3
- H3C UniServer R5300 G5
- H3C UniServer R4950 G5 Rome
- H3C UniServer B5700 G6
- H3C UniServer R4300 G3
- H3C UniServer R5500LC G5 Intel
- H3C UniServer R6700 G6
- H3C UniServer B7800 G3
- H3C UniServer R4700LC G5
- H3C UniServer R5500 G7 Hygon
- H3C UniServer R4700 G3
- H3C UniServer R4950 G7
- H3C UniServer R4900 G6
- H3C UniServer R4500 G6
- H3C UniServer R4900 G7
- H3C UniServer R5500 G5 Intel
- H3C UniServer B5700 G3
- H3C UniServer R3950 G7
- H3C UniServer R5500 G6 AMD
- H3C UniServer R4900LC G5
- H3C UniServer R4330 G5
- H3C UniServer R4300 G6
- H3C UniServer R4930 G5 H3
- H3C UniServer R4930 G7
- H3C UniServer R3350 G7
- H3C UniServer R4930LC G5 H3
- H3C UniServer R4700LE G6
- H3C UniServer B5800 G3
- H3C UniServer R5300 G3
- H3C UniServer R4900 G3
- H3C UniServer R4330 G5 H3
- H3C UniServer R3950 G6
- H3C UniServer R6900 G5
- H3C UniServer R5300 G6
- H3C UniServer R4700 G6
- H3C UniServer R4930 G5
- H3C UniServer R4700 G5
- H3C UniServer E3300 G6
- H3C UniServer R6900 G3
- H3C UniServer R3900 G7
- H3C UniServer R6700 G3
- H3C UniServer R4950 G6
- H3C UniServer R4950 G5 Milan
- H3C UniServer R5330 G7
- H3C UniServer R4330 G7
- H3C UniServer R4900 G6 Ultra
- H3C UniServer R4900 G5
- H3C UniServer R5500 G5 AMD
- H3C UniServer R6900 G6
- H3C UniServer R2700 G3
- H3C UniServer R4300 G7
- H3C UniServer R5500 G6 Intel
OS
N/A
OS Subclass
N/A
New Functions
1.Add support for sending traffic with the same destination MAC address with or without VLAN tagging (DCSG-17231); 2.Added the function of mirroring traffic on port (RoCE+L2) to the RoCE interface (DCSG-10816); 3.Added support for enabling/disabling CQ overflow detection (DCSG-9084); 4.Add support for dbd_cfg parameter (DCSG-15689).
View Details
|
| NIC-ETH531F-LP-2P | 234.1.124.0.00 | Firmware | N/A | N/A | 2025/12/31 |
|
|
Version
234.1.124.0.00
File Name
Firmware Release Notes.pdf(65.54 KB) fw-nic-broadcom-H3C-BCMCD(234.1.124.0.00).zip(79.44 MB)
Description
The software is the firmware upgrade program for Broadcom H3C-BCMCD network card version 234.1.124.0.00.
Problems Solved
1.Fixed the issue of Niccli recovery failure after resetting from damaged firmware (DCSG-41552); 2.Fixed communication issue after firmware update when enabling software untag VLAN (DCSG-41528); 3.Fixed the issue where the PLDM firmware update did not display the image to be updated when the versions of the active and pending images were the same (DCSG-40211); 4.Fixed the issue where the latest PLDM time could not be sent to BMC (DCSG-37593); 5.Fixed an issue where sending PCIe VDM MCTP messages too early could cause the system to hang (DCSG-18324); 6.Fixed the GPIO multiplexing value of OCP Chain pins so that they can be mapped and correctly used for temperature warnings (DCSG-31638); 7.Fixed the fastboot recovery issue where fastboot recovery (DCSG-30725) is not allowed when lockdown is enabled; 8.Fixed the issue where the temperature of the transceiver read from eeprom was good, but the is_tempnvalid flag indicated that it was invalid (DCSG-29165); 9.Fixed LLDP forwarding issue, now always forwarding LLDP packets to BMC (DCSG-29361); 10.Fixed the issue of not being able to obtain DHCP IP in VM (DCSG-13760); 11.If DCBX is enabled on the NCSI path, LLDP disable request (DCSG-3220) is rejected. 12.Whp: Mgmt:To prevent firmware crashes due to a full FIFO (First In, First Out) buffer, using a microsecond timer to adjust timeout calculations can be employed (DCSG-01769683). 13.The task of periodically updating the heartbeat will be delegated to other processes to prevent firmware crashes.
Products
- H3C UniServer R5350 G6
- H3C UniServer R4700 G6
- H3C UniServer R4300 G3
- H3C UniServer B5700 G3
- H3C UniServer R5500 G6 Intel
- H3C UniServer R5500 G5 AMD
- H3C UniServer R5500 G6 AMD
- H3C UniServer R4900 G6
- H3C UniServer R4950 G5 Rome
- H3C UniServer R3900 G7
- H3C UniServer R4900 G6 Ultra
- H3C UniServer R4950 G5 Milan
- H3C UniServer R4900 G7
- H3C UniServer E3200 G3
- H3C UniServer R4950 G5
- H3C UniServer R4330 G5 H3
- H3C UniServer R4500 G3
- H3C UniServer R4300 G7
- H3C UniServer R4930 G5 H3
- H3C UniServer R4300 G6
- H3C UniServer R6900 G5
- H3C UniServer R2900 G3
- H3C UniServer R5500 G7 Hygon
- H3C UniServer R4930LC G5 H3
- H3C UniServer R4300 G5
- H3C UniServer R5500LC G5 Intel
- H3C UniServer B5700 G5
- H3C UniServer R5500 G5 Intel
- H3C UniServer R4950 G6
- H3C UniServer R6900 G6
- H3C UniServer R4900 G3
- H3C UniServer R4900LE G6 Ultra
- H3C UniServer R4500 G6
- H3C UniServer E3300 G6
- H3C UniServer R4330 G7
- H3C UniServer B5700 G6
- H3C UniServer R3350 G7
- H3C UniServer R4700LE G6
- H3C UniServer R5500 G5 HYGON
- H3C UniServer R5300 G6
- H3C UniServer R4930 G7
- H3C UniServer B7800 G3
- H3C UniServer R2700 G3
- H3C UniServer R4700 G3
- H3C UniServer R4900 G5
- H3C UniServer R6700 G3
- H3C UniServer R6900 G3
- H3C UniServer R4330 G5
- H3C UniServer R5300 G3
- H3C UniServer R4700 G5
- H3C UniServer R5300 G5
- H3C UniServer R8900 G3
- H3C UniServer R3950 G7
- H3C UniServer R6700 G6
- H3C UniServer R3950 G6
- H3C UniServer R4930 G5
- H3C UniServer R4900LC G5
- H3C UniServer R4700LC G5
- H3C UniServer R5330 G7
- H3C UniServer B5800 G3
- H3C UniServer R4700 G7
- H3C UniServer R4950 G7
OS
N/A
OS Subclass
N/A
New Functions
1.Add support for sending traffic with the same destination MAC address with or without VLAN tagging (DCSG-17231); 2.Added the function of mirroring traffic on port (RoCE+L2) to the RoCE interface (DCSG-10816); 3.Added support for enabling/disabling CQ overflow detection (DCSG-9084); 4.Add support for dbd_cfg parameter (DCSG-15689).
View Details
|
| NIC-ETH630F-LP-2P | 234.1.124.0.00 | Firmware | N/A | N/A | 2025/12/31 |
|
|
Version
234.1.124.0.00
File Name
Firmware Release Notes.pdf(65.54 KB) fw-nic-broadcom-H3C-BCMCD(234.1.124.0.00).zip(79.44 MB)
Description
The software is the firmware upgrade program for Broadcom H3C-BCMCD network card version 234.1.124.0.00.
Problems Solved
1.Fixed the issue of Niccli recovery failure after resetting from damaged firmware (DCSG-41552); 2.Fixed communication issue after firmware update when enabling software untag VLAN (DCSG-41528); 3.Fixed the issue where the PLDM firmware update did not display the image to be updated when the versions of the active and pending images were the same (DCSG-40211); 4.Fixed the issue where the latest PLDM time could not be sent to BMC (DCSG-37593); 5.Fixed an issue where sending PCIe VDM MCTP messages too early could cause the system to hang (DCSG-18324); 6.Fixed the GPIO multiplexing value of OCP Chain pins so that they can be mapped and correctly used for temperature warnings (DCSG-31638); 7.Fixed the fastboot recovery issue where fastboot recovery (DCSG-30725) is not allowed when lockdown is enabled; 8.Fixed the issue where the temperature of the transceiver read from eeprom was good, but the is_tempnvalid flag indicated that it was invalid (DCSG-29165); 9.Fixed LLDP forwarding issue, now always forwarding LLDP packets to BMC (DCSG-29361); 10.Fixed the issue of not being able to obtain DHCP IP in VM (DCSG-13760); 11.If DCBX is enabled on the NCSI path, LLDP disable request (DCSG-3220) is rejected. 12.Whp: Mgmt:To prevent firmware crashes due to a full FIFO (First In, First Out) buffer, using a microsecond timer to adjust timeout calculations can be employed (DCSG-01769683). 13.The task of periodically updating the heartbeat will be delegated to other processes to prevent firmware crashes.
Products
- H3C UniServer B5800 G3
- H3C UniServer R6700 G6
- H3C UniServer B5700 G3
- H3C UniServer R5500 G7 Hygon
- H3C UniServer R6900 G3
- H3C UniServer R4500 G3
- H3C UniServer R4500 G6
- H3C UniServer R5500 G5 AMD
- H3C UniServer R5330 G7
- H3C UniServer R4300 G6
- H3C UniServer R3950 G7
- H3C UniServer R4300 G5
- H3C UniServer R4950 G6
- H3C UniServer R4900LE G6 Ultra
- H3C UniServer R4900LC G5
- H3C UniServer R5300 G5
- H3C UniServer R4300 G3
- H3C UniServer B7800 G3
- H3C UniServer R4930 G5 H3
- H3C UniServer R4930 G7
- H3C UniServer R4700 G7
- H3C UniServer R5350 G6
- H3C UniServer R4300 G7
- H3C UniServer B5700 G6
- H3C UniServer R4900 G7
- H3C UniServer R4930 G5
- H3C UniServer R4950 G5
- H3C UniServer R4700 G3
- H3C UniServer R5300 G6
- H3C UniServer R2900 G3
- H3C UniServer R5500 G5 HYGON
- H3C UniServer R5500 G6 AMD
- H3C UniServer R4900 G5
- H3C UniServer R5500 G5 Intel
- H3C UniServer R4900 G3
- H3C UniServer R4330 G5
- H3C UniServer E3200 G3
- H3C UniServer R3900 G7
- H3C UniServer R5500LC G5 Intel
- H3C UniServer R4700LE G6
- H3C UniServer R4950 G5 Milan
- H3C UniServer R5300 G3
- H3C UniServer E3300 G6
- H3C UniServer R4700 G5
- H3C UniServer R6700 G3
- H3C UniServer R4950 G5 Rome
- H3C UniServer R4700 G6
- H3C UniServer R6900 G6
- H3C UniServer R3950 G6
- H3C UniServer R4930LC G5 H3
- H3C UniServer R4950 G7
- H3C UniServer R4330 G7
- H3C UniServer R3350 G7
- H3C UniServer R4330 G5 H3
- H3C UniServer R4900 G6 Ultra
- H3C UniServer B5700 G5
- H3C UniServer R2700 G3
- H3C UniServer R6900 G5
- H3C UniServer R5500 G6 Intel
- H3C UniServer R4900 G6
- H3C UniServer R4700LC G5
- H3C UniServer R8900 G3
OS
N/A
OS Subclass
N/A
New Functions
1.Add support for sending traffic with the same destination MAC address with or without VLAN tagging (DCSG-17231); 2.Added the function of mirroring traffic on port (RoCE+L2) to the RoCE interface (DCSG-10816); 3.Added support for enabling/disabling CQ overflow detection (DCSG-9084); 4.Add support for dbd_cfg parameter (DCSG-15689).
View Details
|
| NIC-BCM957414M4142C-C-2x25G | 234.1.124.0 | Firmware | N/A | N/A | 2025/12/31 |
|
|
Version
234.1.124.0
File Name
Firmware Release Notes.pdf(67.71 KB) fw-nic-broadcom-BCMCD(234.1.124.0).zip(248.19 MB)
Description
The software is the firmware upgrade program for Broadcom BCMCD network card version 234.1.124.0.
Problems Solved
1.The issue of Niccli recovery failure after resetting from damaged firmware (DCSG-41552). 2.Wh+: Communication issue caused by updating Broadcom 57414 network card firmware when enabling software untag VLAN (DCSG-41528). 3.When the versions of the active image and pending image are the same, the PLDM firmware update does not display the image to be updated (DCSG-40211). 4.The latest PLDM time cannot be sent to BMC (DCSG-37593). 5.Whp: Mgmt: Discard LLDP packet (DCSG-34687) if RMII is not enabled. 6.Correct the GPIO reuse value of OCP chain pins (DCSG-31638). 7.Niccli windows: Counter clear operation (--- clear) failed (DCSG-30477). 8.There is a timing vulnerability (DCSG-29165) in the current implementation between clearing the temperature valid flag and reading/verifying the temperature. 9.Whp: Mgmt: Always forward LLDP packets to BMC (DCSG-29361). 10.HWRM error (DCSG-22697) occurred while verifying link status on WHITNEY+device. [ +40.128023] bnxt_en 0000:a1:00.1 eth9: hwrm req_type 0xfff1 seq id 0x142 error 0x3 [ +0.000172] bnxt_en 0000:a1:00.1 eth9: hwrm req_type 0xfff1 seq id 0x143 error 0x3 11.Early MCTP messages via PCIe VDM may cause system suspension (DCSG-18324). 12.Whp: Mgmt:To prevent firmware crashes due to a full FIFO (First In, First Out) buffer, using a microsecond timer to adjust timeout calculations can be employed (DCSG-01769683). 13.The task of periodically updating the heartbeat will be delegated to other processes to prevent firmware crashes.
Products
- H3C UniServer R6700 G6
- H3C UniServer R3950 G7
- H3C UniServer R5500 G7 Hygon
- H3C UniServer R4900 G6
- H3C UniServer R4500 G6
- H3C UniServer R4300 G6
- H3C UniServer B7800 G3
- H3C UniServer R4900 G3
- H3C UniServer R5300 G6
- H3C UniServer R5500 G5 AMD
- H3C UniServer R3350 G7
- H3C UniServer R4300 G5
- H3C UniServer R5300 G5
- H3C UniServer R4950 G7
- H3C UniServer E3300 G6
- H3C UniServer R4930 G5
- H3C UniServer R4330 G5 H3
- H3C UniServer R6900 G6
- H3C UniServer R5330 G7
- H3C UniServer R3900 G7
- H3C UniServer R4900 G5
- H3C UniServer R4500 G3
- H3C UniServer R5350 G6
- H3C UniServer R4330 G7
- H3C UniServer R4930LC G5 H3
- H3C UniServer R2900 G3
- H3C UniServer R4300 G7
- H3C UniServer R4300 G3
- H3C UniServer R4700 G6
- H3C UniServer R4900 G7
- H3C UniServer R4950 G6
- H3C UniServer R5500LC G5 Intel
- H3C UniServer R4900 G6 Ultra
- H3C UniServer B5700 G6
- H3C UniServer R4700LC G5
- H3C UniServer R4700LE G6
- H3C UniServer R4930 G5 H3
- H3C UniServer R6900 G3
- H3C UniServer R4700 G7
- H3C UniServer R5300 G3
- H3C UniServer R8900 G3
- H3C UniServer E3200 G3
- H3C UniServer R4930 G7
- H3C UniServer B5700 G5
- H3C UniServer R4700 G3
- H3C UniServer R4700 G5
- H3C UniServer R5500 G5 HYGON
- H3C UniServer R3950 G6
- H3C UniServer R5500 G6 AMD
- H3C UniServer R6700 G3
- H3C UniServer R6900 G5
- H3C UniServer R4950 G5 Rome
- H3C UniServer R4950 G5 Milan
- H3C UniServer R4900LE G6 Ultra
- H3C UniServer R5500 G5 Intel
- H3C UniServer R4950 G5
- H3C UniServer B5800 G3
- H3C UniServer R4900LC G5
- H3C UniServer R2700 G3
- H3C UniServer B5700 G3
- H3C UniServer R4330 G5
- H3C UniServer R5500 G6 Intel
OS
N/A
OS Subclass
N/A
New Functions
1.Implemented the hot upgrade function (DCSG-6354) that can coexist with multiple instance applications. 2.Fix the PLDM PDR entity difference (DCSG-16320) between the code and DSC2054 specification. 3.If DCBX is enabled on the NC-SI path, reject LLDP disable request (DCSG-3220). 4.Added support to allow drivers to change the SGID on the original Ethernet QP (if used for mirroring) in RTR state. The firmware is using modifiy_sqd IM to implement this support (DCSG-31514). 5.Added 200K support for NTUPLE/KTLS filters in Truflow mode (DCSG-21229). 6.Added a change to Thor2 based on DCQCN for 1QP solution (DCSG-18660). 7. Close unused channels (DCSG-26824) in the 400G optical module when operating in 200G mode. 8. Implemented polling optimization based on RoCE counter set for UDCC to improve tx event rate in low activity QP scenarios (DCSG-24565).
View Details
|
| NIC-BCM957416-T-B-10Gb-2P | 234.1.124.0 | Firmware | N/A | N/A | 2025/12/31 |
|
|
Version
234.1.124.0
File Name
Firmware Release Notes.pdf(67.71 KB) fw-nic-broadcom-BCMCD(234.1.124.0).zip(248.19 MB)
Description
The software is the firmware upgrade program for Broadcom BCMCD network card version 234.1.124.0.
Problems Solved
1.The issue of Niccli recovery failure after resetting from damaged firmware (DCSG-41552). 2.Wh+: Communication issue caused by updating Broadcom 57414 network card firmware when enabling software untag VLAN (DCSG-41528). 3.When the versions of the active image and pending image are the same, the PLDM firmware update does not display the image to be updated (DCSG-40211). 4.The latest PLDM time cannot be sent to BMC (DCSG-37593). 5.Whp: Mgmt: Discard LLDP packet (DCSG-34687) if RMII is not enabled. 6.Correct the GPIO reuse value of OCP chain pins (DCSG-31638). 7.Niccli windows: Counter clear operation (--- clear) failed (DCSG-30477). 8.There is a timing vulnerability (DCSG-29165) in the current implementation between clearing the temperature valid flag and reading/verifying the temperature. 9.Whp: Mgmt: Always forward LLDP packets to BMC (DCSG-29361). 10.HWRM error (DCSG-22697) occurred while verifying link status on WHITNEY+device. [ +40.128023] bnxt_en 0000:a1:00.1 eth9: hwrm req_type 0xfff1 seq id 0x142 error 0x3 [ +0.000172] bnxt_en 0000:a1:00.1 eth9: hwrm req_type 0xfff1 seq id 0x143 error 0x3 11.Early MCTP messages via PCIe VDM may cause system suspension (DCSG-18324). 12.Whp: Mgmt:To prevent firmware crashes due to a full FIFO (First In, First Out) buffer, using a microsecond timer to adjust timeout calculations can be employed (DCSG-01769683). 13.The task of periodically updating the heartbeat will be delegated to other processes to prevent firmware crashes.
Products
- H3C UniServer R3900 G7
- H3C UniServer E3300 G6
- H3C UniServer R4500 G3
- H3C UniServer R4300 G7
- H3C UniServer B5700 G5
- H3C UniServer R4700LC G5
- H3C UniServer R4700 G5
- H3C UniServer R4900 G3
- H3C UniServer R3950 G6
- H3C UniServer R5330 G7
- H3C UniServer R5300 G5
- H3C UniServer R4500 G6
- H3C UniServer B7800 G3
- H3C UniServer R6900 G6
- H3C UniServer R4300 G5
- H3C UniServer R4330 G5
- H3C UniServer R6700 G3
- H3C UniServer R4300 G3
- H3C UniServer R2900 G3
- H3C UniServer R5500 G7 Hygon
- H3C UniServer B5800 G3
- H3C UniServer R4930 G7
- H3C UniServer R4900LE G6 Ultra
- H3C UniServer R5300 G3
- H3C UniServer R4900 G5
- H3C UniServer R5500 G5 AMD
- H3C UniServer R5500LC G5 Intel
- H3C UniServer R4330 G7
- H3C UniServer R4300 G6
- H3C UniServer R5500 G5 Intel
- H3C UniServer R4700 G7
- H3C UniServer R4950 G5 Milan
- H3C UniServer R4900 G6
- H3C UniServer R5500 G6 AMD
- H3C UniServer B5700 G6
- H3C UniServer R3950 G7
- H3C UniServer R6900 G5
- H3C UniServer B5700 G3
- H3C UniServer R6900 G3
- H3C UniServer R4700 G6
- H3C UniServer R4330 G5 H3
- H3C UniServer R4900LC G5
- H3C UniServer R4950 G5
- H3C UniServer R4930LC G5 H3
- H3C UniServer R5350 G6
- H3C UniServer R2700 G3
- H3C UniServer R4950 G6
- H3C UniServer R4700 G3
- H3C UniServer R8900 G3
- H3C UniServer R3350 G7
- H3C UniServer E3200 G3
- H3C UniServer R4930 G5 H3
- H3C UniServer R4900 G7
- H3C UniServer R5500 G6 Intel
- H3C UniServer R4700LE G6
- H3C UniServer R5300 G6
- H3C UniServer R4900 G6 Ultra
- H3C UniServer R4930 G5
- H3C UniServer R4950 G7
- H3C UniServer R5500 G5 HYGON
- H3C UniServer R4950 G5 Rome
- H3C UniServer R6700 G6
OS
N/A
OS Subclass
N/A
New Functions
1.Implemented the hot upgrade function (DCSG-6354) that can coexist with multiple instance applications. 2.Fix the PLDM PDR entity difference (DCSG-16320) between the code and DSC2054 specification. 3.If DCBX is enabled on the NC-SI path, reject LLDP disable request (DCSG-3220). 4.Added support to allow drivers to change the SGID on the original Ethernet QP (if used for mirroring) in RTR state. The firmware is using modifiy_sqd IM to implement this support (DCSG-31514). 5.Added 200K support for NTUPLE/KTLS filters in Truflow mode (DCSG-21229). 6.Added a change to Thor2 based on DCQCN for 1QP solution (DCSG-18660). 7. Close unused channels (DCSG-26824) in the 400G optical module when operating in 200G mode. 8. Implemented polling optimization based on RoCE counter set for UDCC to improve tx event rate in low activity QP scenarios (DCSG-24565).
View Details
|
| NIC-BCM957414-F-B-25Gb-2P | 234.1.124.0 | Firmware | N/A | N/A | 2025/12/31 |
|
|
Version
234.1.124.0
File Name
Firmware Release Notes.pdf(67.71 KB) fw-nic-broadcom-BCMCD(234.1.124.0).zip(248.19 MB)
Description
The software is the firmware upgrade program for Broadcom BCMCD network card version 234.1.124.0.
Problems Solved
1.The issue of Niccli recovery failure after resetting from damaged firmware (DCSG-41552). 2.Wh+: Communication issue caused by updating Broadcom 57414 network card firmware when enabling software untag VLAN (DCSG-41528). 3.When the versions of the active image and pending image are the same, the PLDM firmware update does not display the image to be updated (DCSG-40211). 4.The latest PLDM time cannot be sent to BMC (DCSG-37593). 5.Whp: Mgmt: Discard LLDP packet (DCSG-34687) if RMII is not enabled. 6.Correct the GPIO reuse value of OCP chain pins (DCSG-31638). 7.Niccli windows: Counter clear operation (--- clear) failed (DCSG-30477). 8.There is a timing vulnerability (DCSG-29165) in the current implementation between clearing the temperature valid flag and reading/verifying the temperature. 9.Whp: Mgmt: Always forward LLDP packets to BMC (DCSG-29361). 10.HWRM error (DCSG-22697) occurred while verifying link status on WHITNEY+device. [ +40.128023] bnxt_en 0000:a1:00.1 eth9: hwrm req_type 0xfff1 seq id 0x142 error 0x3 [ +0.000172] bnxt_en 0000:a1:00.1 eth9: hwrm req_type 0xfff1 seq id 0x143 error 0x3 11.Early MCTP messages via PCIe VDM may cause system suspension (DCSG-18324). 12.Whp: Mgmt:To prevent firmware crashes due to a full FIFO (First In, First Out) buffer, using a microsecond timer to adjust timeout calculations can be employed (DCSG-01769683). 13.The task of periodically updating the heartbeat will be delegated to other processes to prevent firmware crashes.
Products
- H3C UniServer B7800 G3
- H3C UniServer R5330 G7
- H3C UniServer R5500 G5 AMD
- H3C UniServer R6700 G6
- H3C UniServer R4330 G5
- H3C UniServer R4300 G5
- H3C UniServer R2700 G3
- H3C UniServer R5300 G6
- H3C UniServer R4900LC G5
- H3C UniServer R5500 G5 Intel
- H3C UniServer R4300 G3
- H3C UniServer R4500 G6
- H3C UniServer R4330 G5 H3
- H3C UniServer R4330 G7
- H3C UniServer B5700 G6
- H3C UniServer R4950 G7
- H3C UniServer R8900 G3
- H3C UniServer R4930 G5 H3
- H3C UniServer R4900 G6 Ultra
- H3C UniServer R4930 G7
- H3C UniServer R4950 G5 Milan
- H3C UniServer R4700LE G6
- H3C UniServer R6700 G3
- H3C UniServer R3950 G7
- H3C UniServer R3900 G7
- H3C UniServer R4950 G5 Rome
- H3C UniServer R4300 G6
- H3C UniServer R4700 G6
- H3C UniServer B5700 G3
- H3C UniServer R4700 G7
- H3C UniServer R6900 G6
- H3C UniServer R4930 G5
- H3C UniServer R4900 G6
- H3C UniServer R4300 G7
- H3C UniServer R4900 G3
- H3C UniServer R4900 G7
- H3C UniServer R4500 G3
- H3C UniServer R5500 G5 HYGON
- H3C UniServer R3350 G7
- H3C UniServer E3300 G6
- H3C UniServer R3950 G6
- H3C UniServer R5300 G3
- H3C UniServer R5500 G7 Hygon
- H3C UniServer B5700 G5
- H3C UniServer R4700 G5
- H3C UniServer R4950 G6
- H3C UniServer E3200 G3
- H3C UniServer R2900 G3
- H3C UniServer R4950 G5
- H3C UniServer R5500LC G5 Intel
- H3C UniServer R4700 G3
- H3C UniServer R5500 G6 Intel
- H3C UniServer B5800 G3
- H3C UniServer R4930LC G5 H3
- H3C UniServer R4900 G5
- H3C UniServer R5500 G6 AMD
- H3C UniServer R5300 G5
- H3C UniServer R4900LE G6 Ultra
- H3C UniServer R6900 G5
- H3C UniServer R6900 G3
- H3C UniServer R4700LC G5
- H3C UniServer R5350 G6
OS
N/A
OS Subclass
N/A
New Functions
1.Implemented the hot upgrade function (DCSG-6354) that can coexist with multiple instance applications. 2.Fix the PLDM PDR entity difference (DCSG-16320) between the code and DSC2054 specification. 3.If DCBX is enabled on the NC-SI path, reject LLDP disable request (DCSG-3220). 4.Added support to allow drivers to change the SGID on the original Ethernet QP (if used for mirroring) in RTR state. The firmware is using modifiy_sqd IM to implement this support (DCSG-31514). 5.Added 200K support for NTUPLE/KTLS filters in Truflow mode (DCSG-21229). 6.Added a change to Thor2 based on DCQCN for 1QP solution (DCSG-18660). 7. Close unused channels (DCSG-26824) in the 400G optical module when operating in 200G mode. 8. Implemented polling optimization based on RoCE counter set for UDCC to improve tx event rate in low activity QP scenarios (DCSG-24565).
View Details
|
| NIC-BCM957412M4122C-1x25G | 234.1.124.0 | Firmware | N/A | N/A | 2025/12/31 |
|
|
Version
234.1.124.0
File Name
Firmware Release Notes.pdf(67.71 KB) fw-nic-broadcom-BCMCD(234.1.124.0).zip(248.19 MB)
Description
The software is the firmware upgrade program for Broadcom BCMCD network card version 234.1.124.0.
Problems Solved
1.The issue of Niccli recovery failure after resetting from damaged firmware (DCSG-41552). 2.Wh+: Communication issue caused by updating Broadcom 57414 network card firmware when enabling software untag VLAN (DCSG-41528). 3.When the versions of the active image and pending image are the same, the PLDM firmware update does not display the image to be updated (DCSG-40211). 4.The latest PLDM time cannot be sent to BMC (DCSG-37593). 5.Whp: Mgmt: Discard LLDP packet (DCSG-34687) if RMII is not enabled. 6.Correct the GPIO reuse value of OCP chain pins (DCSG-31638). 7.Niccli windows: Counter clear operation (--- clear) failed (DCSG-30477). 8.There is a timing vulnerability (DCSG-29165) in the current implementation between clearing the temperature valid flag and reading/verifying the temperature. 9.Whp: Mgmt: Always forward LLDP packets to BMC (DCSG-29361). 10.HWRM error (DCSG-22697) occurred while verifying link status on WHITNEY+device. [ +40.128023] bnxt_en 0000:a1:00.1 eth9: hwrm req_type 0xfff1 seq id 0x142 error 0x3 [ +0.000172] bnxt_en 0000:a1:00.1 eth9: hwrm req_type 0xfff1 seq id 0x143 error 0x3 11.Early MCTP messages via PCIe VDM may cause system suspension (DCSG-18324). 12.Whp: Mgmt:To prevent firmware crashes due to a full FIFO (First In, First Out) buffer, using a microsecond timer to adjust timeout calculations can be employed (DCSG-01769683). 13.The task of periodically updating the heartbeat will be delegated to other processes to prevent firmware crashes.
Products
- H3C UniServer B5800 G3
- H3C UniServer B7800 G3
- H3C UniServer E3300 G6
- H3C UniServer R4950 G5 Rome
- H3C UniServer R5500 G6 Intel
- H3C UniServer R4300 G3
- H3C UniServer R4930 G5 H3
- H3C UniServer R4930LC G5 H3
- H3C UniServer R5300 G6
- H3C UniServer R3350 G7
- H3C UniServer R4700 G7
- H3C UniServer R5500LC G5 Intel
- H3C UniServer R6900 G6
- H3C UniServer R4900 G6
- H3C UniServer R4700LE G6
- H3C UniServer R5500 G5 Intel
- H3C UniServer R5500 G7 Hygon
- H3C UniServer R4700LC G5
- H3C UniServer R3950 G6
- H3C UniServer R3950 G7
- H3C UniServer R4900 G5
- H3C UniServer R2900 G3
- H3C UniServer R6900 G5
- H3C UniServer R4930 G7
- H3C UniServer R4930 G5
- H3C UniServer R4300 G5
- H3C UniServer E3200 G3
- H3C UniServer R4700 G3
- H3C UniServer R4330 G5 H3
- H3C UniServer R4300 G6
- H3C UniServer R4300 G7
- H3C UniServer R8900 G3
- H3C UniServer R6700 G6
- H3C UniServer R4900LC G5
- H3C UniServer R4900 G6 Ultra
- H3C UniServer R2700 G3
- H3C UniServer R5500 G6 AMD
- H3C UniServer R3900 G7
- H3C UniServer B5700 G6
- H3C UniServer R4950 G6
- H3C UniServer R6700 G3
- H3C UniServer R5500 G5 AMD
- H3C UniServer R6900 G3
- H3C UniServer R4900LE G6 Ultra
- H3C UniServer R4700 G5
- H3C UniServer R5500 G5 HYGON
- H3C UniServer R4950 G5
- H3C UniServer R4330 G7
- H3C UniServer R5300 G5
- H3C UniServer R5330 G7
- H3C UniServer R4950 G7
- H3C UniServer R5350 G6
- H3C UniServer R4900 G3
- H3C UniServer R4950 G5 Milan
- H3C UniServer R4500 G6
- H3C UniServer R5300 G3
- H3C UniServer R4500 G3
- H3C UniServer R4330 G5
- H3C UniServer B5700 G3
- H3C UniServer R4900 G7
- H3C UniServer B5700 G5
- H3C UniServer R4700 G6
OS
N/A
OS Subclass
N/A
New Functions
1.Implemented the hot upgrade function (DCSG-6354) that can coexist with multiple instance applications. 2.Fix the PLDM PDR entity difference (DCSG-16320) between the code and DSC2054 specification. 3.If DCBX is enabled on the NC-SI path, reject LLDP disable request (DCSG-3220). 4.Added support to allow drivers to change the SGID on the original Ethernet QP (if used for mirroring) in RTR state. The firmware is using modifiy_sqd IM to implement this support (DCSG-31514). 5.Added 200K support for NTUPLE/KTLS filters in Truflow mode (DCSG-21229). 6.Added a change to Thor2 based on DCQCN for 1QP solution (DCSG-18660). 7. Close unused channels (DCSG-26824) in the 400G optical module when operating in 200G mode. 8. Implemented polling optimization based on RoCE counter set for UDCC to improve tx event rate in low activity QP scenarios (DCSG-24565).
View Details
|
| NIC-BCM957508-N2100G-3S-2P | 234.1.124.0 | Firmware | N/A | N/A | 2025/12/31 |
|
|
Version
234.1.124.0
File Name
Firmware Release Notes.pdf(67.71 KB) fw-nic-broadcom-BCMCD(234.1.124.0).zip(248.19 MB)
Description
The software is the firmware upgrade program for Broadcom BCMCD network card version 234.1.124.0.
Problems Solved
1.The issue of Niccli recovery failure after resetting from damaged firmware (DCSG-41552). 2.Wh+: Communication issue caused by updating Broadcom 57414 network card firmware when enabling software untag VLAN (DCSG-41528). 3.When the versions of the active image and pending image are the same, the PLDM firmware update does not display the image to be updated (DCSG-40211). 4.The latest PLDM time cannot be sent to BMC (DCSG-37593). 5.Whp: Mgmt: Discard LLDP packet (DCSG-34687) if RMII is not enabled. 6.Correct the GPIO reuse value of OCP chain pins (DCSG-31638). 7.Niccli windows: Counter clear operation (--- clear) failed (DCSG-30477). 8.There is a timing vulnerability (DCSG-29165) in the current implementation between clearing the temperature valid flag and reading/verifying the temperature. 9.Whp: Mgmt: Always forward LLDP packets to BMC (DCSG-29361). 10.HWRM error (DCSG-22697) occurred while verifying link status on WHITNEY+device. [ +40.128023] bnxt_en 0000:a1:00.1 eth9: hwrm req_type 0xfff1 seq id 0x142 error 0x3 [ +0.000172] bnxt_en 0000:a1:00.1 eth9: hwrm req_type 0xfff1 seq id 0x143 error 0x3 11.Early MCTP messages via PCIe VDM may cause system suspension (DCSG-18324). 12.Whp: Mgmt:To prevent firmware crashes due to a full FIFO (First In, First Out) buffer, using a microsecond timer to adjust timeout calculations can be employed (DCSG-01769683). 13.The task of periodically updating the heartbeat will be delegated to other processes to prevent firmware crashes.
Products
- H3C UniServer R6900 G5
- H3C UniServer R4500 G3
- H3C UniServer R5350 G6
- H3C UniServer R5500 G5 Intel
- H3C UniServer B5700 G3
- H3C UniServer R6700 G3
- H3C UniServer R4900 G7
- H3C UniServer R2900 G3
- H3C UniServer R6900 G3
- H3C UniServer R4900 G5
- H3C UniServer R5500 G6 Intel
- H3C UniServer R3350 G7
- H3C UniServer R4500 G6
- H3C UniServer R4700LC G5
- H3C UniServer R4950 G5
- H3C UniServer R4300 G3
- H3C UniServer R5500 G5 AMD
- H3C UniServer R3950 G7
- H3C UniServer B5700 G6
- H3C UniServer R4930 G7
- H3C UniServer R4330 G5
- H3C UniServer B5700 G5
- H3C UniServer R3950 G6
- H3C UniServer R4900 G6 Ultra
- H3C UniServer E3300 G6
- H3C UniServer R5330 G7
- H3C UniServer R4950 G5 Milan
- H3C UniServer R5300 G6
- H3C UniServer R4330 G5 H3
- H3C UniServer R4950 G5 Rome
- H3C UniServer R5500 G7 Hygon
- H3C UniServer R4900LE G6 Ultra
- H3C UniServer R5500 G5 HYGON
- H3C UniServer R4930 G5 H3
- H3C UniServer B7800 G3
- H3C UniServer R4930 G5
- H3C UniServer R8900 G3
- H3C UniServer R4300 G6
- H3C UniServer R5500 G6 AMD
- H3C UniServer R6700 G6
- H3C UniServer R4330 G7
- H3C UniServer R4700 G6
- H3C UniServer B5800 G3
- H3C UniServer R4700 G7
- H3C UniServer R3900 G7
- H3C UniServer R4930LC G5 H3
- H3C UniServer R4950 G7
- H3C UniServer R4700 G3
- H3C UniServer E3200 G3
- H3C UniServer R4700LE G6
- H3C UniServer R4700 G5
- H3C UniServer R6900 G6
- H3C UniServer R2700 G3
- H3C UniServer R4950 G6
- H3C UniServer R4900 G3
- H3C UniServer R5500LC G5 Intel
- H3C UniServer R5300 G5
- H3C UniServer R5300 G3
- H3C UniServer R4900LC G5
- H3C UniServer R4900 G6
- H3C UniServer R4300 G5
- H3C UniServer R4300 G7
OS
N/A
OS Subclass
N/A
New Functions
1.Implemented the hot upgrade function (DCSG-6354) that can coexist with multiple instance applications. 2.Fix the PLDM PDR entity difference (DCSG-16320) between the code and DSC2054 specification. 3.If DCBX is enabled on the NC-SI path, reject LLDP disable request (DCSG-3220). 4.Added support to allow drivers to change the SGID on the original Ethernet QP (if used for mirroring) in RTR state. The firmware is using modifiy_sqd IM to implement this support (DCSG-31514). 5.Added 200K support for NTUPLE/KTLS filters in Truflow mode (DCSG-21229). 6.Added a change to Thor2 based on DCQCN for 1QP solution (DCSG-18660). 7. Close unused channels (DCSG-26824) in the 400G optical module when operating in 200G mode. 8. Implemented polling optimization based on RoCE counter set for UDCC to improve tx event rate in low activity QP scenarios (DCSG-24565).
View Details
|
| NIC-BCM957508-P2100G-2P | 234.1.124.0 | Firmware | N/A | N/A | 2025/12/31 |
|
|
Version
234.1.124.0
File Name
Firmware Release Notes.pdf(67.71 KB) fw-nic-broadcom-BCMCD(234.1.124.0).zip(248.19 MB)
Description
The software is the firmware upgrade program for Broadcom BCMCD network card version 234.1.124.0.
Problems Solved
1.The issue of Niccli recovery failure after resetting from damaged firmware (DCSG-41552). 2.Wh+: Communication issue caused by updating Broadcom 57414 network card firmware when enabling software untag VLAN (DCSG-41528). 3.When the versions of the active image and pending image are the same, the PLDM firmware update does not display the image to be updated (DCSG-40211). 4.The latest PLDM time cannot be sent to BMC (DCSG-37593). 5.Whp: Mgmt: Discard LLDP packet (DCSG-34687) if RMII is not enabled. 6.Correct the GPIO reuse value of OCP chain pins (DCSG-31638). 7.Niccli windows: Counter clear operation (--- clear) failed (DCSG-30477). 8.There is a timing vulnerability (DCSG-29165) in the current implementation between clearing the temperature valid flag and reading/verifying the temperature. 9.Whp: Mgmt: Always forward LLDP packets to BMC (DCSG-29361). 10.HWRM error (DCSG-22697) occurred while verifying link status on WHITNEY+device. [ +40.128023] bnxt_en 0000:a1:00.1 eth9: hwrm req_type 0xfff1 seq id 0x142 error 0x3 [ +0.000172] bnxt_en 0000:a1:00.1 eth9: hwrm req_type 0xfff1 seq id 0x143 error 0x3 11.Early MCTP messages via PCIe VDM may cause system suspension (DCSG-18324). 12.Whp: Mgmt:To prevent firmware crashes due to a full FIFO (First In, First Out) buffer, using a microsecond timer to adjust timeout calculations can be employed (DCSG-01769683). 13.The task of periodically updating the heartbeat will be delegated to other processes to prevent firmware crashes.
Products
- H3C UniServer R4930 G5
- H3C UniServer R4930LC G5 H3
- H3C UniServer R3950 G6
- H3C UniServer R4300 G3
- H3C UniServer R5300 G5
- H3C UniServer R6900 G5
- H3C UniServer R8900 G3
- H3C UniServer R2900 G3
- H3C UniServer R6700 G3
- H3C UniServer R4700 G7
- H3C UniServer R4330 G5 H3
- H3C UniServer B5700 G3
- H3C UniServer E3200 G3
- H3C UniServer R4950 G6
- H3C UniServer R5300 G3
- H3C UniServer R4700LC G5
- H3C UniServer R4950 G5 Rome
- H3C UniServer R2700 G3
- H3C UniServer B5700 G5
- H3C UniServer R4930 G5 H3
- H3C UniServer R5500 G5 AMD
- H3C UniServer R5500 G6 Intel
- H3C UniServer R5500 G7 Hygon
- H3C UniServer R4950 G7
- H3C UniServer R4950 G5
- H3C UniServer R4300 G7
- H3C UniServer R4300 G6
- H3C UniServer R5350 G6
- H3C UniServer R5330 G7
- H3C UniServer R4330 G7
- H3C UniServer R3950 G7
- H3C UniServer R4900 G3
- H3C UniServer R4900LE G6 Ultra
- H3C UniServer R6900 G6
- H3C UniServer E3300 G6
- H3C UniServer R4500 G6
- H3C UniServer R5300 G6
- H3C UniServer R4330 G5
- H3C UniServer R4900LC G5
- H3C UniServer R3350 G7
- H3C UniServer B5700 G6
- H3C UniServer R4700 G6
- H3C UniServer R5500 G5 HYGON
- H3C UniServer B7800 G3
- H3C UniServer R4900 G5
- H3C UniServer R5500LC G5 Intel
- H3C UniServer B5800 G3
- H3C UniServer R4950 G5 Milan
- H3C UniServer R5500 G5 Intel
- H3C UniServer R4700 G3
- H3C UniServer R5500 G6 AMD
- H3C UniServer R4500 G3
- H3C UniServer R4300 G5
- H3C UniServer R6700 G6
- H3C UniServer R4700 G5
- H3C UniServer R6900 G3
- H3C UniServer R4700LE G6
- H3C UniServer R3900 G7
- H3C UniServer R4930 G7
- H3C UniServer R4900 G6 Ultra
- H3C UniServer R4900 G7
- H3C UniServer R4900 G6
OS
N/A
OS Subclass
N/A
New Functions
1.Implemented the hot upgrade function (DCSG-6354) that can coexist with multiple instance applications. 2.Fix the PLDM PDR entity difference (DCSG-16320) between the code and DSC2054 specification. 3.If DCBX is enabled on the NC-SI path, reject LLDP disable request (DCSG-3220). 4.Added support to allow drivers to change the SGID on the original Ethernet QP (if used for mirroring) in RTR state. The firmware is using modifiy_sqd IM to implement this support (DCSG-31514). 5.Added 200K support for NTUPLE/KTLS filters in Truflow mode (DCSG-21229). 6.Added a change to Thor2 based on DCQCN for 1QP solution (DCSG-18660). 7. Close unused channels (DCSG-26824) in the 400G optical module when operating in 200G mode. 8. Implemented polling optimization based on RoCE counter set for UDCC to improve tx event rate in low activity QP scenarios (DCSG-24565).
View Details
|
| NIC-BCM957412-F-B-10Gb-2P | 234.1.124.0 | Firmware | N/A | N/A | 2025/12/31 |
|
|
Version
234.1.124.0
File Name
Firmware Release Notes.pdf(67.71 KB) fw-nic-broadcom-BCMCD(234.1.124.0).zip(248.19 MB)
Description
The software is the firmware upgrade program for Broadcom BCMCD network card version 234.1.124.0.
Problems Solved
1.The issue of Niccli recovery failure after resetting from damaged firmware (DCSG-41552). 2.Wh+: Communication issue caused by updating Broadcom 57414 network card firmware when enabling software untag VLAN (DCSG-41528). 3.When the versions of the active image and pending image are the same, the PLDM firmware update does not display the image to be updated (DCSG-40211). 4.The latest PLDM time cannot be sent to BMC (DCSG-37593). 5.Whp: Mgmt: Discard LLDP packet (DCSG-34687) if RMII is not enabled. 6.Correct the GPIO reuse value of OCP chain pins (DCSG-31638). 7.Niccli windows: Counter clear operation (--- clear) failed (DCSG-30477). 8.There is a timing vulnerability (DCSG-29165) in the current implementation between clearing the temperature valid flag and reading/verifying the temperature. 9.Whp: Mgmt: Always forward LLDP packets to BMC (DCSG-29361). 10.HWRM error (DCSG-22697) occurred while verifying link status on WHITNEY+device. [ +40.128023] bnxt_en 0000:a1:00.1 eth9: hwrm req_type 0xfff1 seq id 0x142 error 0x3 [ +0.000172] bnxt_en 0000:a1:00.1 eth9: hwrm req_type 0xfff1 seq id 0x143 error 0x3 11.Early MCTP messages via PCIe VDM may cause system suspension (DCSG-18324). 12.Whp: Mgmt:To prevent firmware crashes due to a full FIFO (First In, First Out) buffer, using a microsecond timer to adjust timeout calculations can be employed (DCSG-01769683). 13.The task of periodically updating the heartbeat will be delegated to other processes to prevent firmware crashes.
Products
- H3C UniServer R4330 G5
- H3C UniServer R4900 G7
- H3C UniServer R4900LE G6 Ultra
- H3C UniServer R6700 G3
- H3C UniServer R4700LC G5
- H3C UniServer R3350 G7
- H3C UniServer R3900 G7
- H3C UniServer R4700LE G6
- H3C UniServer R4950 G5
- H3C UniServer B5700 G6
- H3C UniServer R5350 G6
- H3C UniServer R5300 G6
- H3C UniServer B5700 G3
- H3C UniServer R4930LC G5 H3
- H3C UniServer R6900 G6
- H3C UniServer R4930 G7
- H3C UniServer R4900LC G5
- H3C UniServer R6900 G5
- H3C UniServer R4300 G7
- H3C UniServer R4950 G7
- H3C UniServer R4950 G5 Rome
- H3C UniServer R8900 G3
- H3C UniServer R4950 G6
- H3C UniServer B7800 G3
- H3C UniServer R4500 G3
- H3C UniServer R4900 G5
- H3C UniServer E3200 G3
- H3C UniServer E3300 G6
- H3C UniServer R4950 G5 Milan
- H3C UniServer R4300 G3
- H3C UniServer R4500 G6
- H3C UniServer R5500 G6 AMD
- H3C UniServer R5500LC G5 Intel
- H3C UniServer R4330 G7
- H3C UniServer R3950 G7
- H3C UniServer R4700 G3
- H3C UniServer R4700 G7
- H3C UniServer R4700 G5
- H3C UniServer R4900 G6 Ultra
- H3C UniServer R4900 G6
- H3C UniServer R5500 G5 HYGON
- H3C UniServer R4930 G5 H3
- H3C UniServer R5500 G6 Intel
- H3C UniServer R4300 G6
- H3C UniServer R5500 G5 AMD
- H3C UniServer R6700 G6
- H3C UniServer R5500 G7 Hygon
- H3C UniServer R4330 G5 H3
- H3C UniServer R4700 G6
- H3C UniServer B5700 G5
- H3C UniServer R5300 G3
- H3C UniServer R6900 G3
- H3C UniServer R5300 G5
- H3C UniServer R4300 G5
- H3C UniServer R5330 G7
- H3C UniServer B5800 G3
- H3C UniServer R2900 G3
- H3C UniServer R2700 G3
- H3C UniServer R4900 G3
- H3C UniServer R5500 G5 Intel
- H3C UniServer R3950 G6
- H3C UniServer R4930 G5
OS
N/A
OS Subclass
N/A
New Functions
1.Implemented the hot upgrade function (DCSG-6354) that can coexist with multiple instance applications. 2.Fix the PLDM PDR entity difference (DCSG-16320) between the code and DSC2054 specification. 3.If DCBX is enabled on the NC-SI path, reject LLDP disable request (DCSG-3220). 4.Added support to allow drivers to change the SGID on the original Ethernet QP (if used for mirroring) in RTR state. The firmware is using modifiy_sqd IM to implement this support (DCSG-31514). 5.Added 200K support for NTUPLE/KTLS filters in Truflow mode (DCSG-21229). 6.Added a change to Thor2 based on DCQCN for 1QP solution (DCSG-18660). 7. Close unused channels (DCSG-26824) in the 400G optical module when operating in 200G mode. 8. Implemented polling optimization based on RoCE counter set for UDCC to improve tx event rate in low activity QP scenarios (DCSG-24565).
View Details
|