WB R4900 G6 MCPLD(2026/8/7)

Category-Component Type:

Firmware-CPLD

Version:

009

OS:

N/A-N/A

    Description

  • Description
  • Installation steps
  • Publish Description
  • Problems Solved
  • New Functions
  • Historical Versions
  • Description

    The software is used to upgrade main control logic CPLD of the R4900 G6 server

  • Installation steps

    Restrictions and guidelines

    None.

  • Publish Description

    Supported products

    H3C UniServer R4900 G6

    Restrictions and guidelines

    None.

    Version information

    Version number

    Version number: 011

    The object file name and MD5 checksum for this version:

    RS3M2C10S01009.bin:79f28c6f09e376cdf6cf77a4650dca8a

     

     

    NOTE:

    You can access the HDM Web interface of the server to identify the version on the System > System Overview > Others page.

     

    Table 1 Version history

    Version number

    Last version

    Release date

    Version type

    Remarks

    V009

    V008

    2026-07-21

    Release version

    N/A

    V008

    V007

    2025-04-18

    Release version

    N/A

    V007

    V006

    2025-03-01

    Release version

    N/A

    V006

    V005

    2024-07-11

    Release version

    N/A

    V005

    V004

    2023-11-25

    Release version

    N/A

    V004

    First release

    2023-07-30

    N/A

    N/A

     

    Supported languages

    English.

    Chinese.

    Supported hardware platforms

    H3C UniServer R4900 G6

    Hardware and software compatibility matrix

    CAUTION:

    To avoid an update failure, use the following table to verify the hardware and software compatibility before performing an update.

     

    Table 2 Hardware and software compatibility matrix

    Item

    Specifications

    Product family

    H3C UniServer R4900 G6

    Main board MCPLD

    V009 or later

    Main board SCPLD

    V006 or later

    Main board VR

    V003 or later

    HDM

    1.80 or later

    BIOS

    6.10.51 or later

    Image file name and MD5 value

    RS3M2C10S01009.bin:79f28c6f09e376cdf6cf77a4650dca8a

    Remarks

    N/A.

     

    (Optional) Version compatibility with ISSU

    None.

    Update recommendation

    Update to this version is recommended.

    Update restrictions and guidelines

    Make sure the server and the HDM client (such as a PC) can reach each other.

    For a successful bulk update, make sure you can update one server successfully before you update the remaining servers.

    During the update, make sure the network connection is available and do not refresh the webpage.

    Do not refresh the page during the update.

    To avoid CPLD or operating system errors, do not power on or power off the server during the firmware update.

    After the firmware is updated, clear the browser cache before you re-log in to HDM.

  • Problems Solved

    S0 physical button short press shielding;

    Short press event reported to BMC;

    202504180374

    Symptom: If you install the Iluvatar V100 GPU on the server, the system might fail to identify this GPU after a hot restart.

    Condition: This symptom might occur if you install the Iluvatar V100 GPU on the server.

    202411120993

    Symptom: When the P9560 storage controller in OCP form is installed to the onboard OCP2 position, HDM displays that the DSD card is present and a DSD card power failure alarm occurs.

    Condition: This symptom might occur if the P9560 storage controller in OCP form is installed to the onboard OCP2 position.

    202305120064

    Symptom: HDM cannot distinguish MCA error types when MCA errors occur.

    Condition: This symptom might occur when MCA errors occur.

    202305071600

    Symptom: When the RS46R3X16 riser card is installed, PCIe slots 1 and 3 on the riser card cannot identify PCIe modules.

    Condition: This symptom might occur if a PCIe module is installed in PCIe slot 1 or 3 on the RS46R3X16 riser card.

    202308111392

    Symptom: No alarm is generated on HDM after the DSD card is powered off abnormally because of a power fault. 

    Condition: This symptom might occur if the DSD card is powered off abnormally. 

  • New Functions

  • Version:009(2026/8/7)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    S0 physical button short press shielding;

    Short press event reported to BMC;

    202504180374

    Symptom: If you install the Iluvatar V100 GPU on the server, the system might fail to identify this GPU after a hot restart.

    Condition: This symptom might occur if you install the Iluvatar V100 GPU on the server.

    202411120993

    Symptom: When the P9560 storage controller in OCP form is installed to the onboard OCP2 position, HDM displays that the DSD card is present and a DSD card power failure alarm occurs.

    Condition: This symptom might occur if the P9560 storage controller in OCP form is installed to the onboard OCP2 position.

    202305120064

    Symptom: HDM cannot distinguish MCA error types when MCA errors occur.

    Condition: This symptom might occur when MCA errors occur.

    202305071600

    Symptom: When the RS46R3X16 riser card is installed, PCIe slots 1 and 3 on the riser card cannot identify PCIe modules.

    Condition: This symptom might occur if a PCIe module is installed in PCIe slot 1 or 3 on the RS46R3X16 riser card.

    202308111392

    Symptom: No alarm is generated on HDM after the DSD card is powered off abnormally because of a power fault. 

    Condition: This symptom might occur if the DSD card is powered off abnormally. 

    New Functions

    Version:V008(2025/5/20)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    202504180374

    Symptom: If you install the Iluvatar V100 GPU on the server, the system might fail to identify this GPU after a hot restart.

    Condition: This symptom might occur if you install the Iluvatar V100 GPU on the server.

    202411120993

    Symptom: When the P9560 storage controller in OCP form is installed to the onboard OCP2 position, HDM displays that the DSD card is present and a DSD card power failure alarm occurs.

    Condition: This symptom might occur if the P9560 storage controller in OCP form is installed to the onboard OCP2 position.

    202305120064

    Symptom: HDM cannot distinguish MCA error types when MCA errors occur.

    Condition: This symptom might occur when MCA errors occur.

    202305071600

    Symptom: When the RS46R3X16 riser card is installed, PCIe slots 1 and 3 on the riser card cannot identify PCIe modules.

    Condition: This symptom might occur if a PCIe module is installed in PCIe slot 1 or 3 on the RS46R3X16 riser card.

    202308111392

    Symptom: No alarm is generated on HDM after the DSD card is powered off abnormally because of a power fault. 

    Condition: This symptom might occur if the DSD card is powered off abnormally. 

    New Functions

    Version:V007(2025/4/1)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    202411120993

    Symptom: When the P9560 storage controller in OCP form is installed to the onboard OCP2 position, HDM displays that the DSD card is present and a DSD card power failure alarm occurs.

    Condition: This symptom might occur if the P9560 storage controller in OCP form is installed to the onboard OCP2 position.

    202305120064

    Symptom: HDM cannot distinguish MCA error types when MCA errors occur.

    Condition: This symptom might occur when MCA errors occur.

    202305071600

    Symptom: When the RS46R3X16 riser card is installed, PCIe slots 1 and 3 on the riser card cannot identify PCIe modules.

    Condition: This symptom might occur if a PCIe module is installed in PCIe slot 1 or 3 on the RS46R3X16 riser card.

    202308111392

    Symptom: No alarm is generated on HDM after the DSD card is powered off abnormally because of a power fault. 

    Condition: This symptom might occur if the DSD card is powered off abnormally. 

    New Functions

    Version:V006(2024/8/7)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    New Functions