R4700 G5 BIOS(2023/8/17)

Category-Component Type:

Firmware-BIOS

Version:

5.66

OS:

N/A-N/A

    Description

  • Description
  • Installation steps
  • Publish Description
  • Problems Solved
  • New Functions
  • Historical Versions
  • Description

    This software is used to upgrade the BIOS version of the R4900 G5 server

  • Installation steps

  • Publish Description

    Products

    H3C UniServer R4700 G5

    Restrictions and cautions

    Restrictions

    The upgrade to BIOS-5.24 or later from an earlier version on the HDM Web interface for the R4900 G5, R4700 G5, R5300 G5, R5500 G5(Intel), S4703 G5, S2703 G5, B5700 G5, or H3C UniStor X10000 G5 supports only the Forcedly restore method. To retain the user-configured settings in the earlier version, perform the following operations:

    a.Export the configuration file of the earlier version.

    b.Upgrade to BIOS-5.24 or later by selecting the Forcedly restore method.

    c.Import the configuration file of the earlier version after the upgrade.

    The upgrade to BIOS-5.31 or later from an earlier version on the HDM Web interface for the R6900 G5 supports only the Forcedly restore method. To retain the user-configured settings in the earlier version, perform the following operations:

    a.Export the configuration file of the earlier version.

    b.Upgrade to BIOS-5.31 or later by selecting the Forcedly restore method.

    c.Import the configuration file of the earlier version after the upgrade.

    As from release BIOS-5.53, if you use the AFU tool in the OS to perform an upgrade with the user-configured settings retained, you can retain the core disable number setting configured on the Advanced > Socket Configuration > Processor Configuration > Per-Socket Configuration > CPU Socket 1 Configuration screen. If you upgrade from BIOS-5.52 or an earlier version, the core disable number setting cannot be retained. 

    Guidelines

    To avoid BIOS boot failures, do not upgrade or reset HDM during BIOS boot.

    Version information

    Version number

    Version 5.66

    Table 1 Target file name and MD5 checksum

    Model

    File name and MD5 checksum

    H3C UniServer R4300 G5/R4700 G5/R4900 G5/R4900LC G5/R4700LC G5

    C35-BIOS-5.66-signed: 548e84593a7db60fe4fbfdfb0d8c12cc

    UN-BPS_02.02.00.1553-signed.bin: edd144ec6baa0f43758d1971213cb386

    UN-BPS_02.02.00.1553_Linux.rpm: e9dc270cc32c98246e597694bfb5e7fe

    H3C UniServer R6900 G5

    P18-BIOS-5.66-signed.bin: b7ebac6cf5ca1415cd8bcf4a20f3c43c

    UN-BPS_02.02.00.1553-signed.bin: edd144ec6baa0f43758d1971213cb386

    UN-BPS_02.02.00.1553_Linux.rpm: 7e9c5e5385b7be0f3230b310019fcccc

     

    You can access the HDM Web interface of the server to identify the BIOS firmware version in the Device information section of the Dashboard > Summary page, as shown in Figure 1.

    Figure 1 Viewing the BIOS version number from HDM

    图片 5

     

    BIOS built-in software version

    Table 2 BIOS built-in software version for the H3C UniServer R4300 G5, R4700 G5, R4900 G5, R4900LC G5, R5300 G5, R5500 G5(Intel), S4703 G5, S2703 G5, B5700 G5, and H3C UniStor X10000 G5

    Item

    Version

    Microcode

    IceLake Production MCU: m_87_606a6_0d000375.mcb

    Intel BKC Version

    2022_WW23(KIT #732569)

    RC Code

    Intel® Central Park Whitley Release 27P82

    ME Firmware

    SPS_E5_04.04.04.202.0

    RSTe PreOS Components

    v7.6.0.1012

    VMD VROC

    v7.6.0.1012

    DCPMM UEFI and HII Driver

    v02.00.00.3886

    DCPMM Firmware

    02.02.00.1553

    BIOS ACM

    BIOS ACM v1.1.0/SINIT ACM v1.1.0

     

    Table 3 BIOS built-in software version for the R6900 G5

    Item

    Version

    Microcode

    CooperLake A0 MCU: mbf5065a_86000020.mcb

    CooperLake A1 MCU: mbf5065b_07002501.mcb

    Intel BKC version

    2022.3 IPU-PV(KIT#738662)

    RC code

    Intel® Central Park Whitley Release 23P42

    ME firmware

    SPS_E5_04.04.04.202.0

    RSTe PreOS components

    v7.6.0.1012

    VMD VROC

    v7.6.0.1012

    DCPMM UEFI and HII driver

    v02.00.00.3887

    DCPMM Firmware

    02.02.00.1553

    BIOS ACM

    BIOS ACM v1.3.4/ SINIT ACM v1.3.5

     

    Hardware and software compatibility matrixes

    CAUTION:

    To avoid update failure, verify the hardware and software compatibility before performing an update.

     

    Table 4 Hardware and software compatibility matrix for H3C UniServer R4300 G5

    Item

    Specifications

    Model

    H3C UniServer R4300 G5

    HDM

    Version 3.38.01 or later

    CPLD

    Version 001 or later

    iMC

    N/A

    PMem 200 firmware version

    UN-BPS_02.02.00.1553

    Remarks

    When updating the BIOS version, or installing, updating, or replacing the PMem 200 firmware, make sure the BIOS version is compatible with the PMem 200 firmware version.

     

    Table 5 Hardware and software compatibility matrix for H3C UniServer R4900 G5/R4700 G5/R4900LC G5/R4700LC G5

    Item

    Specifications

    Model

    H3C UniServer R4900 G5/R4700 G5/R4900LC G5

    HDM

    Version 3.38.01 or later

    CPLD

    Version 005 or later

    iMC

    N/A

    PMem 200 firmware version

    UN-BPS_02.02.00.1553

    Remarks

    When updating the BIOS version, or installing, updating, or replacing the PMem 200 firmware, make sure the BIOS version is compatible with the PMem 200 firmware version.

     

    Table 6 Hardware and software compatibility matrix for H3C UniServer R5300 G5

    Item

    Specifications

    Model

    H3C UniServer R5300 G5

    HDM

    Version 3.39 or later

    CPLD

    Version 003 or later

    PFRCPLD

    Version 001 or later

    iMC

    N/A

    PMem 200 firmware version

    UN-BPS_02.02.00.1553

    Remarks

    When updating the BIOS version, or installing, updating, or replacing the PMem 200 firmware, make sure the BIOS version is compatible with the PMem 200 firmware version.

     

    Table 7 Hardware and software compatibility matrix for H3C UniServer R6900 G5

    Item

    Specifications

    Model

    H3C UniServer R6900 G5

    HDM

    Version 3.38.01 or later

    CPLD

    Version 007 or later

    PFRCPLD

    Version 005 or later

    DBCPLD

    Version 005 or later

    iMC

    N/A

    PMem 200 firmware version

    UN-BPS_02.02.00.1553

    Remarks

    When updating the BIOS version, or installing, updating, or replacing the PMem 200 firmware, make sure the BIOS version is compatible with the PMem 200 firmware version.

     

    Update restrictions and guidelines

    This version is optional.

    Make sure the software versions are compatible with each other.

    To update both HDM and the BIOS, update HDM first.

    Make sure the server is running in stable state before the update. That is, the server is powered off or has entered the operating system.

    If the server enters the OS before the update, you must power cycle the server for the new firmware to take effect.

    If you select the Retain or Restore method to update the BIOS, the update occurs during POST after the server is powered on again. During the update, do not disconnect the power source from the server, or forcedly power off or restart the server.

    If you select the Forcedly restore method to update the BIOS, do not disconnect the power source from the server, or power off or restart the server.

    Selecting the Restore or Forcedly restore method will restore the default BIOS settings, including restoring the boot mode in the BIOS to the default (UEFI).

    During BIOS update with Forcedly restore selected, writing BIOS data, such as restarting the system or saving BIOS configuration from the BIOS setup utility, can cause data write errors. This can lead to BIOS ROM integrity check failures and even system starting failures. If the system prompts Flash Image Broken! System Halt!, forcedly power off the server, and then try to update the BIOS with Forcedly restore selected again.

    As a best practice of bulk update, make sure you can update one server successfully before you update the remaining servers.

  • Problems Solved

    Resolved problems in BIOS-5.66

    Symptom: When the R5300 G5 server is installed with eight H800 GPUs in HPC mode, the BIOS gets stuck at the progress of 16% during self-test, and a watchdog error occurs on HDM.

    Condition: This symptom might occur if the R5300 G5 server is installed with eight H800 GPUs.

    Symptom: After the security bezel of the server in power-on state is hot swapped, the Logo LED turns on but the decorative LEDs do not turn on. After the server restarts, the decorative LEDs turn on.

    Condition: This symptom might occur if the security bezel is hot swapped when the server is powered on.

  • New Functions

  • Version:5.81(2025/11/11)

    Upgrade recommendations

    Upgrade recommended

    Problems Solved

    Resolved problems in BIOS-5.81

    202510111170

    Symptom: When the server's memory CE is triggered repeatedly, the OS system experiences a brief delay.

    Condition: This symptom might occur if the server's memory CE is triggered repeatedly.

    202509151155

    Symptom: In BIOS-5.80, switching to Legacy mode or disabling the Above 4G option result in insufficient resource allocation on the server.

    Condition: This symptom might occur if you switch to Legacy mode or disable the Above 4G option in BIOS-5.80.

    202508120684

    Symptom: If the LSI-9540-8i controller creates Foreign information on the dual-socket server, mouse cursor lag might occur during tracking in the BIOS graphics mode HII management interface.

    Condition: This symptom might occur if the LSI-9540-8i controller creates Foreign information on the dual-socket server and you switch to the HII management interface in the BIOS graphics mode.

    New Functions

    Version:5.80(2025/8/19)

    Upgrade recommendations

    Optional upgrade

    Problems Solved

    Resolved problems in BIOS-5.80

    202504010964

    Symptom: When VMD is set to Enabled for the dual-processor server, the HDM storage page and PCIe device page fail to display AIC card information.

    Condition: This symptom might occur if you view AIC card information on the HDM storage page and PCIe device page when VMD is set to Enabled for the dual-processor server.

    202506100417

    Symptom: A dual-processor server might fail to enter the OS and a processor might report a severe alarm during BIOS boot up when DIMM slots are not fully populated and SGX is set to Enabled on the server.

    Condition: This symptom might occur if DIMM slots are not fully populated and SGX is set to Enabled on a dual-processor server.

    New Functions

    Version:5.79(2025/6/27)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in BIOS-5.79

    202504241644

    Symptom: The turbo frequency lock failed when you set Static Turbo to Auto after setting Workload Profile Config to Fixed Turbo Frequency.

    Condition: This symptom might occur if you set Static Turbo to Auto after setting Workload Profile Config to Fixed Turbo Frequency.

    New Functions

    Version:5.78(2025/1/15)

    Upgrade recommendations

    Optional upgrade

    Problems Solved

    Resolved problems in BIOS-5.78

    202411130861

    Symptom: A CPU DCU alarm occurred due to a DIMM fault on the server. The DCU alarm message cannot be resolved and the SEL log does not report the position of the faulty DIMM.

    Condition: This symptom might occur if a CPU DCU alarm occurred due to a DIMM fault on the server.

    202408211405

    Symptom: When you obtain information about a CXMT DIMM from HDM, the returned serial number lacks the initial part compared to the actual physical DIMM.

    Condition: This symptom might occur if you obtain information about a CXMT DIMM from HDM.

    New Functions

    Version:5.77(2024/12/23)

    Upgrade recommendations

    Optional upgrade

    Problems Solved

    Resolved problems in BIOS-5.77

    202409261855

    Symptom: To address the issue of the CPU experiencing momentary throttling, the default value of the Domain HW Protection Enabled option in the BIOS requires modification.

    Condition: None.

    New Functions

    Version:5.76(2024/9/24)

    Upgrade recommendations

    Recommended upgrade

    Problems Solved

    Resolved problems in BIOS-5.76

    Symptom: In UEFI mode, two boot options are displayed on the BIOS-EXIT interface after you install the SLES 15 (64 bit) SP1 system.

    Condition: This symptom might occur if you switch to UEFI mode and view the SLES 15 (64 bit) SP1 system boot options on the BIOS-EXIT interface.

    Symptom: R5300 G5 with multiple Intel Flex 170 GPUs gets stuck at the UPI Initializing stage upon startup and restarts repeatedly.

    Condition: This symptom might occur if you install multiple Intel Flex170 GPUs on the R5300 G5.

    New Functions

    Version:5.74(2024/5/27)

    Upgrade recommendations

    Optional upgrade

    Problems Solved

    Resolved problems in BIOS-5.74

    Symptom: The unit of the memory rate changes to MT/s.

    Condition: This symptom might occur if you view the memory rate and its unit in the BIOS setup utility.

    New Functions

    Version:5.73.01(2024/4/18)

    Upgrade recommendations

    Optional upgrade

    Problems Solved

    Resolved problems in BIOS-5.73.01

    Symptom: Added support for out-of-band modification of the Workload Profile for dual-processor server models.

    Condition: None.

    New Functions

    Version:5.71(2024/1/17)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in BIOS-5.71

    Symptom: In Legacy mode, the MAC addresses of the NIC-ETH630F-LP-2P and NIC-ETH641F-LP-2P network adapters are displayed as 0.

    Condition: This symptom might occur in Legacy mode if you view the MAC addresses of NIC-ETH630F-LP-2P and NIC-ETH641F-LP-2P.

    Symptom: When a PCIe 1.0 module is connected to the R4900 G5 server, some functions are unavailable during basic function operation under the OS.

    Condition: This symptom might occur if a PCIe 1.0 module is connected to a R4900 G5 server.

    New Functions

    Version:5.69.10(2023/12/5)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in BIOS-5.69.10

    Symptom: The PCIe 10-bit Tag Support option needs to be displayed properly on the BIOS Setup utility.

    Condition: This symptom might occur when you view related options on the BIOS Setup utility.

    New Functions

    Version:5.69(2023/10/31)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in BIOS-5.69

    Symptom: After the BIOS restarts, the HDM Web interface displays the state of certified memory as non-certified.

    Condition: This symptom might occur after the BIOS restarts.

    New Functions

    Version:5.66(2023/8/17)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in BIOS-5.66

    Symptom: When the R5300 G5 server is installed with eight H800 GPUs in HPC mode, the BIOS gets stuck at the progress of 16% during self-test, and a watchdog error occurs on HDM.

    Condition: This symptom might occur if the R5300 G5 server is installed with eight H800 GPUs.

    Symptom: After the security bezel of the server in power-on state is hot swapped, the Logo LED turns on but the decorative LEDs do not turn on. After the server restarts, the decorative LEDs turn on.

    Condition: This symptom might occur if the security bezel is hot swapped when the server is powered on.

    New Functions

    Version:5.65(2023/8/1)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in BIOS-5.65

    Symptom: When you execute IPMI commands to specify PXE as the next boot option in Legacy mode and edit the network adapter polling order in the BIOS setup utility, the displayed configuration is not consistent with the actually saved configuration after a reboot.

    Condition: This symptom might occur if you execute IPMI commands to specify PXE as the next boot option in Legacy mode and edit the network adapter polling order in the BIOS setup utility, and then save the configuration and perform a reboot.

    Symptom: The system might fail to identify the USB 3.0 drive inserted to the USB connector on the right chassis ear on the R5500 G5 might not be identified.

    Condition: This symptom might occur if the USB 3.0 drive is inserted to the USB connector on the right chassis ear on the R5500 G5.

    New Functions