Upgrade recommendations
Recommended Upgrade
Problems Solved
Resolved problems in BIOS-6.10.576.10.57
Symptom: When the server memory CEs are intermittently triggered, the OS system experiences brief delays.
Condition: This symptom might occur when the server memory CEs are intermittently triggered.
Symptom: Enabling the Hot-plug function on slot 20 of the R5500 G6 server affects network adapter reset in the system.
Condition: This symptom might occur if you enable the Hot-plug function on slot 20 of the R5500 G6 server.
New Functions
Upgrade recommendations
Recommended Upgrade
Problems Solved
Resolved problems in BIOS-6.10.53
Symptom: After you set Workload Profile Config to Fixed Turbo Frequency, setting Static Turbo to Auto will cause Fixed Turbo Frequency to fail to lock the turbo frequency.
Condition: This symptom might occur if you Static Turbo to Auto after setting Workload Profile Config to Fixed Turbo Frequency.
New Functions
Upgrade recommendations
Upgrade recommended
Problems Solved
Resolved problems in BIOS-6.10.47
Symptom: When a GPU server model is installed with the P800 GPU, the BIOS dynamically changes the Re-size BAR support option to Enable.
Condition: This symptom might occur if the P800 GPU is installed.
Symptom: When a GPU server model is installed with the P800 GPU, the BIOS dynamically changes the MMIO High Granularity option to 1.
Condition: This symptom might occur if the P800 GPU is installed.
Symptom: When the R5300 G6 server is configured with the X32 Switch board, OCP network adapters and 12LFF drives, the BIOS displays slot numbers of OCP network adapters incorrectly.
Condition: This symptom might occur if you view slot numbers of OCP network adapters on the R5300 G6 server configured with the X32 Switch board, OCP network adapters and 12LFF drives.
New Functions
Upgrade recommendations
optional Upgrade
Problems Solved
Resolved problems in BIOS-6.10.38
Symptom: Opened the Sharelink feature in the BIOS Setup Utility.
Condition: None.
New Functions
Upgrade recommendations
Recommended Upgrade
Problems Solved
Resolved problems in BIOS-6.10.36
Symptom: In legacy mode, entering the BIOS setup utility might result in screen flickering for one to two seconds.
Condition: This symptom might occur if you enter the BIOS setup utility in legacy mode.
Symptom: When the server is configured with 5x8 DDR5 memory settings, the Rank Type option on the Advanced > Socket Configuration > Memory Configuration > Memory Topology page displays 10x4 in the BIOS setup utility.
Condition: This symptom might occur if you enter the BIOS setup utility for the server configured with 5x8 DDR5 memory settings.
New Functions
Upgrade recommendations
Recommended Upgrade
Problems Solved
Resolved problems in BIOS-6.00.34
Symptom: For the key management module and shared network switch in the BIOS setup utility, some of their functions might fail to switch between Chinese and English when you press the hotkeys F3 and F2 to switch between the two languages.
Condition: This symptom might occur for the key management module and shared network switch in the BIOS setup utility when you press the hotkeys F3 and F2 to switch between Chinese and English.
Symptom: When you disable the disk boot option and enter the OS through a new boot option created at the same path, restart and enter the BIOS. As a result, the original disabled boot option is enabled again.
Condition: This symptom might occur if you disable the disk boot option and enter the OS through a new boot option created at the same path.
Symptom: When a USB LAN is connected to the network cable and PXE poll is performed in Legacy mode, the USB LAN cannot enter PXE.
Condition: This symptom might occur if PXE poll is performed in Legacy mode when you connect a USB LAN to the network cable.
New Functions
Version:6.00.32(2023/11/30)
Upgrade recommendations
Recommended Upgrade
Problems Solved
Resolved problems in BIOS-6.00.32
Symptom: If the server is equipped with a PCIe card with the speed reduction function, after you restart the server and enter the BIOS, no accompanying log is reported by the SDS.
Condition: This symptom might occur if you restart a server equipped with a PCIe card with the speed reduction function.
Symptom: The units of the Memory Frequency options are different in Chinese and English versions.
Condition: This symptom might occur if you view the Memory Frequency options in Chinese and English versions.
New Functions