Upgrade recommendations
optional
Problems Solved
Resolved problems in BIOS-6.10.62
Symptom: An FRB2 timeout reboot is triggered when you connect the server to an external device that supports VPD Cap but has invalid VPD field in BIOS-6.10.61.
Condition: This symptom might occur if you connect the server to an external device that supports VPD Cap but has invalid VPD field in BIOS-6.10.61.
New Functions
Upgrade recommendations
Recommended Upgrade
Problems Solved
Resolved problems in BIOS-6.10.61
Symptom: The server completes the operating system installation through a USB drive. If you do not remove the USB drive, the server still defaults to booting from the USB drive upon restart, and re-enters the installation boot interface.
Condition: This symptom might occur if the server completes the operating system installation through a USB drive and restarts with the USB drive connected.
New Functions
Upgrade recommendations
optional
Problems Solved
Resolved problems in BIOS-6.10.59
Symptom: After you configure and save the HDM address on the screen of the BIOS Setup Utility, the information on the screen fails to automatically refresh.
Condition: This symptom might occur if you configure and save the HDM address on the screen of the BIOS Setup Utility.
Symptom: On the R6900 G6 server with all four processors, when eight, twelve, or sixteen 96GB DIMMs are installed, the system might report DIMM absence after a version upgrade to BIOS-6.10.57.
Condition: This symptom might occur if you upgrade the BIOS version to BIOS-6.10.57 when eight, twelve, or sixteen 96GB DIMMs are installed on the R6900 G6 server with all four processors.
Symptom: When you mistakenly enable VMD for the slot where the Switch board resides on the R5500 G6 server, the Switch driver fails to be loaded.
Condition: This symptom might occur if you mistakenly enable VMD for the slot where the Switch board resides on the R5500 G6 server.
New Functions
Upgrade recommendations
Recommended Upgrade
Problems Solved
Resolved problems in BIOS-6.10.576.10.57
Symptom: When the server memory CEs are intermittently triggered, the OS system experiences brief delays.
Condition: This symptom might occur when the server memory CEs are intermittently triggered.
Symptom: Enabling the Hot-plug function on slot 20 of the R5500 G6 server affects network adapter reset in the system.
Condition: This symptom might occur if you enable the Hot-plug function on slot 20 of the R5500 G6 server.
New Functions
Upgrade recommendations
optional Upgrade
Problems Solved
Resolved problems in BIOS-6.10.45
Symptom: After you update the BIOS firmware to version 6.10.43 on the server with the ATS2600 BMC VA card, the BIOS setup utility gets stuck, which affects normal operations.
Condition: This symptom might occur if you update the BIOS firmware to version 6.10.43 on the server with the ATS2600 BMC VA card.
Symptom: When the R5500 G6 server with different GPU modules restarts into PXE, IEH-related alarms are reported.
Condition: This symptom might occur if the R5500 G6 server with different GPU modules restarts into PXE.
Symptom: The R5500 G6 server has different PE port orders when it is installed with EMR CPUs and SPR CPUs.
Condition: This symptom might occur if you view the PE port order on the R5500 G6 server installed with EMR CPUs.
New Functions
Version:6.10.43(2024/8/9)
Upgrade recommendations
optional Upgrade
Problems Solved
Resolved problems in BIOS-6.10.43
Symptom: A server equipped with Intel S4510 & S4520 SATA M.2 SSDs loses drives after a DC cold reboot. You can update the BIOS firmware to version 6.10.43 or later and perform an AC power cycle to resolve the issue.
Condition: This symptom might occur after you perform a DC cold reboot on a server.
Symptom: A processor UCE alarm occurs when you restore the NUMA option to the default through IPMI in an out-of-band manner.
Condition: This symptom might occur if you issue an IPMI command to clear CMOS.
Symptom: When the server memory configuration supports enabling SGX, change the SGX option from Disable to Enable. After you save the configuration and restart the server, the SGX option is not displayed.
Condition: This symptom might occur if you change the SGX option when the server memory configuration supports enabling SGX.
Symptom: Bandwidth loss might occur if you perform stress test on some network adapters in the server.
Condition: This symptom might occur if you perform stress test on some network adapters when these network adapters are connected to the server.
Symptom: HDM displays different bandwidth information when Lynxi GPUs are connected to the R5300 G6 in different methods.
Condition: This symptom might occur if you view bandwidth information from HDM when Lynxi GPUs are connected to the R5300 G6 server in different methods.
New Functions