Problems Solved
Resolved problems in BIOS-6.10.59
Symptom: After you configure and save the HDM address on the screen of the BIOS Setup Utility, the information on the screen fails to automatically refresh.
Condition: This symptom might occur if you configure and save the HDM address on the screen of the BIOS Setup Utility.
Symptom: On the R6900 G6 server with all four processors, when eight, twelve, or sixteen 96GB DIMMs are installed, the system might report DIMM absence after a version upgrade to BIOS-6.10.57.
Condition: This symptom might occur if you upgrade the BIOS version to BIOS-6.10.57 when eight, twelve, or sixteen 96GB DIMMs are installed on the R6900 G6 server with all four processors.
Symptom: When you mistakenly enable VMD for the slot where the Switch board resides on the R5500 G6 server, the Switch driver fails to be loaded.
Condition: This symptom might occur if you mistakenly enable VMD for the slot where the Switch board resides on the R5500 G6 server.
New Functions
Upgrade recommendations
optional
Problems Solved
Resolved problems in BIOS-6.10.58
Symptom: The default value of the SMI Threshold field on the Advanced > Emca Settings > EMCA CMCI screen of the BIOS Setup Utility is changed from hexadecimal number to decimal number 8192.
Condition: None.
Symptom: The Route IP address option of the gateway setting field on the Server > BMC Dedicated Network Port screen of the BIOS Setup Utility is changed to Default Gateway.
Condition: None.
New Functions
Upgrade recommendations
Recommended Upgrade
Problems Solved
Resolved problems in BIOS-6.10.576.10.57
Symptom: When the server memory CEs are intermittently triggered, the OS system experiences brief delays.
Condition: This symptom might occur when the server memory CEs are intermittently triggered.
Symptom: Enabling the Hot-plug function on slot 20 of the R5500 G6 server affects network adapter reset in the system.
Condition: This symptom might occur if you enable the Hot-plug function on slot 20 of the R5500 G6 server.
New Functions
Upgrade recommendations
Recommended Upgrade
Problems Solved
Resolved problems in BIOS-6.10.55
Symptom: The system fails to obtain the speed of the NIC-ETH360T-3S-4P network adapter during BIOS initialization.
Condition: This symptom might occur if you view the network adapter speed during BIOS initialization.
New Functions
Upgrade recommendations
Recommended Upgrade
Problems Solved
Resolved problems in BIOS-6.10.53
Symptom: After you set Workload Profile Config to Fixed Turbo Frequency, setting Static Turbo to Auto will cause Fixed Turbo Frequency to fail to lock the turbo frequency.
Condition: This symptom might occur if you Static Turbo to Auto after setting Workload Profile Config to Fixed Turbo Frequency.
New Functions
Upgrade recommendations
Optional upgrade
Problems Solved
Resolved problems in BIOS-6.10.49P01
Symptom: When the server is installed with the KUNLUNXIN P800 GPU, the GPU configuration menu correctly in the BIOS setup utility.
Condition: This symptom might occur if you view GPU information in the BIOS setup utility when the server is installed with the KUNLUNXIN P800 GPU.
New Functions
Upgrade recommendations
Upgrade recommended
Problems Solved
Resolved problems in BIOS-6.10.46
Symptom: After you install BCLinux, the Exit screen displays the two same boot options.
Condition: This symptom might occur if you install BCLinux.
Symptom: You can scan the QR code in the BIOS setup utility for the generic model to go to the link for the official manual.
Condition: N/A
New Functions
Upgrade recommendations
optional Upgrade
Problems Solved
Resolved problems in BIOS-6.10.43
Symptom: A server equipped with Intel S4510 & S4520 SATA M.2 SSDs loses drives after a DC cold reboot. You can update the BIOS firmware to version 6.10.43 or later and perform an AC power cycle to resolve the issue.
Condition: This symptom might occur after you perform a DC cold reboot on a server.
Symptom: A processor UCE alarm occurs when you restore the NUMA option to the default through IPMI in an out-of-band manner.
Condition: This symptom might occur if you issue an IPMI command to clear CMOS.
Symptom: When the server memory configuration supports enabling SGX, change the SGX option from Disable to Enable. After you save the configuration and restart the server, the SGX option is not displayed.
Condition: This symptom might occur if you change the SGX option when the server memory configuration supports enabling SGX.
Symptom: Bandwidth loss might occur if you perform stress test on some network adapters in the server.
Condition: This symptom might occur if you perform stress test on some network adapters when these network adapters are connected to the server.
Symptom: HDM displays different bandwidth information when Lynxi GPUs are connected to the R5300 G6 in different methods.
Condition: This symptom might occur if you view bandwidth information from HDM when Lynxi GPUs are connected to the R5300 G6 server in different methods.
New Functions
Version:6.10.41(2024/6/3)
Upgrade recommendations
optional Upgrade
Problems Solved
Resolved problems in BIOS-6.10.41
Symptom: The Post interface displays memory information in MHz instead of MT/s.
Condition: This symptom might occur if you view the memory rate from the BIOS Setup Utility.