H3C SR6608-M[6616-M] Routers Hardware Information and Specifications-6W103

HomeSupportRoutersSR6600-M SeriesProduct LiteratureHardware Information & SpecificationsH3C SR6608-M[6616-M] Routers Hardware Information and Specifications-6W103
01-About the Router
Title Size Download
01-About the Router 2.51 MB

1 About the router

Unless otherwise stated, routing and forwarding units (RFUs), FIP modules, HMIC-F interface modules, HMIC interface modules, and SSD modules are collectively referred to as "modules" in this document.

Chassis views

The figures in this section are for illustration only.

SR6608-M

Figure1-1 SR6608-M front panel

(1) Interface module slot 2

(2) Interface module slot 4

(3) Interface module slot 3

(4) Interface module slot 5

(5) RFU slot 0

(6) RFU slot 1

(7) Power supply slot PWR3

(8) Power supply slot PWR2

(9) Power supply slot PWR1

(10) Power supply slot PWR0

(11) Interface module slot 7

(12) Interface module slot 9

(13) Interface module slot 6

(14) Interface module slot 8

 

Figure1-2 SR6608-M rear panel

(1) Fan tray slot 0

(2) Fan tray slot 1

(3) Grounding screw

 

SR6616-M

Figure1-3 SR6616-M front panel

(1) Interface module slot 2

(2) Interface module slot 4

(3) Interface module slot 6

(4) Interface module slot 8

(5) RFU slot 0

(6) Interface module slot 3

(7) Interface module slot 5

(8) Interface module slot 7

(9) Interface module slot 9

(10) Power supply slot PWR5

(11) Power supply slot PWR4

(12) Power supply slot PWR3

(13) Power supply slot PWR2

(14) Power supply slot PWR1

(15) Power supply slot PWR0

(16) Interface module slot 11

(17) Interface module slot 13

(18) Interface module slot 15

(19) Interface module slot 17

(20) RFU slot 1

(21) Interface module slot 10

(22) Interface module slot 12

(23) Interface module slot 14

(24) Interface module slot 16

 

Figure1-4 SR6616-M rear panel

(1) Fan tray slot 0

(2) Fan tray slot 1

(3) Grounding screw

 

SR6608-F

Figure1-5 SR6608-F front panel

(1) FIP module slot 2

(2) FIP module slot 3

(3) RFU slot 0

(4) RFU slot 1

(5) Power supply slot PWR3

(6) Power supply slot PWR2

(7) Power supply slot PWR1

(8) Power supply slot PWR0

(9) FIP module slot 5

(10) FIP module slot 4

 

Figure1-6 SR6608-F rear panel

(1) Fan tray slot 0

(2) Fan tray slot 1

(3) Grounding screw

 

Slot arrangement and interface numbering

Slot arrangement

Table1-1 Slot arrangement on the router

Model

Slot arrangement

SR6608-M

SR6616-M

SR6608-F

FIP-60-G

: RFU slot

: HMIC interface module or SSD module slot

: FIP module slot

: HMIC-F interface module slot

 

Interface numbering

Conventions

The interfaces (except the management Ethernet interface) on the router are numbered in the interface-type X/Y/Z format. The management Ethernet interface number is M-GigabitEthernet 0/0/0.

·     interface-typeType of the interface such as GigabitEthernet and Ten-GigabitEthernet.

·     X—Number of the slot where the module resides on the router, as shown in Table1-1.

·     Y—Subslot number. For the SR6608-M or SR6616-M router, the slot number is fixed at 0. For the SR6608-F router, Y represents the slot number for the HMIC-F interface module on the FIP module, which is fixed to 1 or 2.

·     Z—Number of the interface on the module, starting from 0.

Examples

For the SR6608-M router, an HMIC-XP4 interface module is installed in slot 6 of the router. Fixed SFP+ fiber ports on the interface module are numbered Ten-GigabitEthernet 6/0/0 through Ten-GigabitEthernet 6/0/3, respectively.

For the SR6608-M router, an RFU-560-G is installed in slot 0 of the router. The fixed SFP+ fiber port on the RFU-560-G is numbered Ten-GigabitEthernet 0/0/0.

For the SR6608-F router, a FIP-60-G module is installed in slot 2 of the device and an HMIC-XP2-F interface module is installed in slot 1 of the FIP-60-G module. Fixed SFP+ fiber ports on the interface module are numbered Ten-GigabitEthernet 2/1/0 through Ten-GigabitEthernet 2/1/1, respectively.

Technical specifications

Table1-2 SR6608-M/SR6616-M/SR6608-F technical specifications

Item

SR6608-M

SR6616-M

SR6608-F

Dimensions (H × W × D) (excluding rubber feet and mounting brackets)

175 × 440 × 330 mm (6.89 × 17.32 × 12.99 in)

263.9 × 442 × 350 mm (10.39 × 17.40 × 13.78 in)

175 × 440 × 330 mm (6.89 × 17.32 × 12.99 in)

Chassis weight (including mounting brackets and filler panels)

11.5 kg (25.35 lb)

19.16 kg (42.24 lb)

11.42 kg (25.18 lb)

Device weight

Weights of the chassis (including mounting brackets and filler panels), modules, power supplies, fan trays, and other removable components

Weights of the chassis (including mounting brackets and filler panels), modules, power supplies, fan trays, and other removable components

Weights of the chassis (including mounting brackets and filler panels), modules, power supplies, fan trays, and other removable components

System power consumption

Total power consumption of all modules and fan trays

Total power consumption of all modules and fan trays

Total power consumption of all modules and fan trays

Heat dissipation

Heat dissipation of the router per hour is 0.9 × (total power consumption of all modules and fan trays)/0.9 × 3.4121

Heat dissipation of the router per hour is 0.9 × (total power consumption of all modules and fan trays)/0.9 × 3.4121

Heat dissipation of the router per hour is 0.9 × (total power consumption of all modules and fan trays)/0.9 × 3.4121

RFU slots

2

2

2

FIP module slots

N/A

N/A

4

HMIC interface module/SSD module slots

8

16

N/A

Fan tray slots

2

2

2

Power supply slots

4

6

4

Operating temperature

0°C to 45°C (32°F to 113°F)

0°C to 45°C (32°F to 113°F)

0°C to 45°C (32°F to 113°F)

Operating humidity

5% RH to 95% RH, noncondensing

5% RH to 95% RH, noncondensing

5% RH to 95% RH, noncondensing

 

 

NOTE:

Heat dissipation is measured in BTU/h. 1 W equals 3.4121 BTU/h.

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Intelligent Storage
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
  • Technical Blogs
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网