- Table of Contents
- Related Documents
-
Title | Size | Download |
---|---|---|
01-HH3C-SPB-MIB | 121.75 KB |
Contents
HH3C-SPB-MIB
About this MIB
Use this MIB to management the global SPBM status, interface-specific SPBM status, and B-VLAN and SPBM multicast replication mode of a VSI.
MIB file name
hh3c-spb.mib
Root object
iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).hh3c(25506).hh3cCommon(2).hh3cSpb(128)
Scalar objects
hh3cSpbSysStatus
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
hh3cSpbSysStatus (1.3.6.1.4.1.25506.2.128.1.1.1) |
read-write |
INTEGER |
enabled(1) disabled(2) |
Global SPBM status. |
As per the MIB. |
hh3cSpbMulticastBVlanStatus
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
hh3cSpbMulticastBVlanStatus (1.3.6.1.4.1.25506.2.128.1.1.2) |
read-write |
INTEGER |
enabled(1) disabled(2) |
Global multicast B-VLAN status. |
As per the MIB. |
hh3cSpbConflictSysID
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
hh3cSpbConflictSysID (1.3.6.1.4.1.25506.2.128.1.3.1.1) |
read-only |
MacAddress |
OCTET STRING (6) |
Remote SPSource ID involved in a conflict. |
As per the MIB. |
hh3cSpbConflictSPSourceID
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
hh3cSpbConflictSPSourceID (1.3.6.1.4.1.25506.2.128.1.3.1.2) |
read-only |
IEEE8021SpbmSPsourceId |
OCTET STRING (3) |
Source ID that causes a conflict. |
As per the MIB. |
hh3cSpbConflictBMac
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
hh3cSpbConflictBMac (1.3.6.1.4.1.25506.2.128.1.3.1.3) |
read-only |
MacAddress |
OCTET STRING (6) |
BMAC address that causes a conflict. |
As per the MIB. |
Tabular objects
hh3cSpbIfTable
About this table
Use this table to obtain the status of SPBM on an interface.
Support for operations
Create |
Edit/Modify |
Delete |
Read |
Not supported |
Supported |
Not supported |
Supported |
Columns
The table index is ifIndex.
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
hh3cSpbIfStatus (1.3.6.1.4.1.25506.2.128.1.2.1.1.1) |
read-write |
INTEGER |
enabled(1) disabled(2) |
SPBM status. |
As per the MIB. |
hh3cSpbSrvTable
About this table
Use this table to manage B-VLAN and SPBM multicast replication mode settings of a VSI.
Support for operations
Create |
Edit/Modify |
Delete |
Read |
Not supported |
Supported |
Not supported |
Supported |
Columns
The table indexes are h3cSpbSrvTableEntryTopIx and h3cSpbSrvTableEntryIsid.
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
hh3cSpbSrvTableEntryTopIx (1.3.6.1.4.1.25506.2.128.1.2.2.1.1) |
not-accessible |
Unsigned32 |
Standard MIB values. |
Topology ID. |
As per the MIB. |
hh3cSpbSrvTableEntryIsid(1.3.6.1.4.1.25506.2.128.1.2.2.1.2) |
not-accessible |
Unsigned32 |
Unsigned32(255..16777215) |
I-SID. |
As per the MIB. |
hh3cSpbSrvTableEntryBaseVid(1.3.6.1.4.1.25506.2.128.1.2.2.1.3) |
read-write |
VlanIdOrNone |
Integer32 (0 | 1..4094) |
B-VLAN. |
As per the MIB. |
hh3cSpbSrvTableEntryMode(1.3.6.1.4.1.25506.2.128.1.2.2.1.4) |
read-write |
INTEGER |
headEnd(1) tandem(2) |
SPBM multicast replication mode. |
As per the MIB. |
Notifications
hh3cSpbSPSourceConflictTrap
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.128.1.3.0.1 |
SPSource ID conflict. |
Informational |
Informational |
- |
ON |
Notification triggers
The notification is generated if the remote SPSource ID and the local SPSource ID conflict.
System impact
Route flapping might occur, and service traffic forwarding might be affected.
Status control
ON
CLI: Use the snmp-agent trap enable spbm spsource-conflict command.
OFF
CLI: Use the undo snmp-agent trap enable spbm spsource-conflict command.
Objects
OID (object name) |
Description |
Index nodes |
Type |
Value range |
1.3.6.1.4.1.25506.2.128.1.3.1.1 (hh3cSpbConflictSysID) |
Remote SPSource ID. |
N/A |
MacAddress |
OCTET STRING (6) |
1.3.6.1.4.1.25506.2.128.1.3.1.2 (hh3cSpbConflictSPSourceID) |
Conflicted SPSource ID. |
N/A |
IEEE8021SpbmSPsourceId |
OCTET STRING (3) |
Recommended action
1. Modify the local or remote SPSource ID.
2. If the issue persists, collect alarm information and configuration data, and then contact H3C Support.
hh3cSpbBMacConflictTrap
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.128.1.3.0.2 |
Remote and local B-MAC conflict. |
Informational |
Informational |
- |
ON |
Notification triggers
This notification is generated if the remote B-MAC and local B-MAC conflict.
System impact
SPBM packets fail to be forwarded.
Status control
ON
CLI: Use the snmp-agent trap enable spbm b-mac-conflict command.
OFF
CLI: Use the undo snmp-agent trap enable spbm b-mac-conflict command.
Objects
OID (object name) |
Description |
Index nodes |
Type |
Value range |
1.3.6.1.4.1.25506.2.128.1.3.1.1 (hh3cSpbConflictSysID) |
Remote SPSource ID. |
N/A |
MacAddress |
OCTET STRING (6) |
1.3.6.1.4.1.25506.2.128.1.3.1.3 (hh3cSpbConflictBMac) |
Conflicted B-MAC. |
N/A |
MacAddress |
OCTET STRING (6) |
Recommended action
1. Modify the local or remote B-MAC.
2. If the issue persists, collect alarm information and configuration data, and then contact H3C Support.