clock

Syntax

clock { auto | manual source source-number }

undo clock work-mode

View

System view

Default level

2: System level

Parameters

auto: Sets the clock monitoring module to work in auto mode.

manual source source-number: Sets the clock monitoring module to work in manual mode, where source-number represents the primary clock source number in manual mode, in the range of 1 to 14.

Description

Use the clock command to set the work mode of the clock monitoring module, either auto mode or manual mode.

Use the undo clock work-mode command to restore the default.

By default, the work mode is auto.

Before configuring the work mode to manual, use the display clock source command to view the clock source state. Only clocks that work normally can be configured as the primary clock source.

After you set the work mode of the clock monitoring module, it takes a period of time for device response. You can check whether your configuration takes effect through the display clock device command and the logging information.

Examples

# Set the clock work mode to manual, and the primary clock source to 1.

<Sysname> system-view

[Sysname] clock manual source 1

clock forcessm

Syntax

clock forcessm { on | off } source source-number

View

System view

Default level

2: System level

Parameters

on: Specifies not to derive the SSM levels from the clock source, which means to use the SSM levels manually configured by users.

off: Specifies to derive the SSM levels from the clock source, which means the user-configured SSM levels do not take effect.

source source-number: Number of clock source, in the range of 1 to 2.

Description

Use the clock forcessm command to set how the SSM levels are derived.

By default, no SSM level is derived from any clock source, which means the SSM levels are manually configured.

Related commands: clock ssm.

Examples

# Derive SSM level from the clock source 1.

<Sysname> system-view

[Sysname] clock forcessm off source 1

clock lpuport

Syntax

clock lpuport interface-type interface-number

undo clock lpuport interface-type interface-number

View

System view

Default level

2: System level

Parameters

interface-type interface-number: Specifies a port by its type and number.

Description

Use the clock lpuport command to specify the input port of the line clock source.

Use the undo clock lpuport command to restore the default.

By default, the clock input port is the first configurable port by port name in lexical order of the interface card.

 

 

NOTE:

·       For a POS interface card, if you set the port clock to work in slave mode, you must use this command to select the input port of the board clock source.

·       The clock of the input port of the line clock source must work in slave mode. For how to set the clock mode by using the clock command, see Interface Command Reference.

 

Examples

# Set the input port of the line clock source to POS interface 3/1/1.

<Sysname> system-view

[Sysname] clock lpuport pos 3/1/1

clock priority

Syntax

clock priority value source source-number

undo clock priority source source-number

View

System view

Default level

2: System level

Parameters

value: Priority value, which is in the range of 1 to 14  or takes the value of 255.

source source-number: Number of clock source, in the range of 1 to 14.

Description

Use the clock priority command to set the reference source priority.

Use the undo clock priority command to restore the default.

By default, the priority of all reference sources is 255.

Examples

# Set the priority of reference source 2 to 3.

<Sysname> system-view

[Sysname] clock priority 3 source 2

clock sa-bit

Syntax

clock sa-bit { sa4 | sa5 | sa6 | sa7 | sa8 } source source-number

undo clock sa-bit source source-number

View

System view

Default level

2: System level

Parameters

sa4: Indicates that the bit position is sa4.

sa5: Indicates that the bit position is sa5.

sa6: Indicates that the bit position is sa6.

sa7: Indicates that the bit position is sa7.

sa8: Indicates that the bit position is sa8.

source source-number: Number of Bits clock source, in the range of 1 to 2.

Description

Use the clock sa-bit command to set the bit used to transmit Bits clock source information.

Use the undo clock sa-bit command to restore the default.

By default, sa4 is used to carry the SSM information.

Examples

# Set the bit used to transmit Bits clock source 1 information to sa5.

<Sysname> system-view

[Sysname] clock sa-bit sa5 source 1

clock ssm

Syntax

clock ssm { dnu | lnc | prc | sets | tnc | unknown } source source-number

undo clock ssm source source-number

View

System view

Default level

2: System level

Parameters

dnu: Specifies the SSM level as DNU. (DoNotUse).

lnc: Specifies the SSM level as LNC (G.812 local node clock signal).

prc: Specifies the SSM level as PRC (G.811 clock signal).

sets: Specifies the SSM level as SETS (SDH device clock source signal).

tnc: Specifies the SSM level as TNC (G.812 transit node clock signal).

unknown: Specifies the SSM level as unknown (Unknown synchronization quality).

source source-number: Number of reference source, in the range of 1 to 14.

Description

Use the clock ssm command to set the SSM levels of the reference sources.

Use the undo clock ssm command to restore the default.

By default, the SSM level of all reference sources is unknown.

For the line clock source, the SSM level configured is that of the clock source.

For Bits clock source, if the input signal is a 2048 kbps (E1) signal and the clock forcessm off source is executed, the clock source adopts the SSM level derived from the input signals and the SSM configured is omitted.

For Bits clock source, if the input signal is a 2048 kHz signal or a 2048 kbps signal and the clock forcesssm on source command is executed, the clock source adopts the SSM level configured.

After you set the SSM levels of the reference sources, it takes a period of time for device response. In this case, you can check whether your configuration takes effect through the display clock ssm-level command and the logging information.

Examples

# Set the SSM level of clock source 1 to DNU.

<Sysname> system-view

[Sysname] clock ssm dnu source 1

clock ssmcontrol

Syntax

clock ssmcontrol { on | off }

undo clock ssmcontrol

View

System view

Default level

2: System level

Parameters

on: Specifies to activate SSM level.

off: Specifies to deactivate SSM level.

Description

Use the clock ssmcontrol command to activate or deactivate SSM level.

Use the undo clock ssmcontrol command to restore the default.

By default, SSM level is deactivated.

When SSM level is activated, the clock source is determined by the SSM level in reference source automatic selection.

When SSM level is not activated, you can still set and view the SSM levels, but they are ignored in reference source automatic selection and the clock source is determined by reference source priority.

Examples

# Activate SSM of clock monitoring module.

<Sysname> system-view

[Sysname] clock ssmcontrol on

display clock config

Syntax

display clock config [ | { begin | exclude | include } regular-expression ]

View

Any view

Default level

1: Monitor level

Parameters

|: Filters command output by specifying a regular expression. For more information about regular expressions, see Fundamentals Configuration Guide.

begin: Displays the first line that matches the specified regular expression and all lines that follow.

exclude: Displays all lines that do not match the specified regular expression.

include: Displays all lines that match the specified regular expression.

regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.

Description

Use the display clock config command to display the current configurations of the clock monitoring module.

Examples

# View the current configurations of the clock monitoring module.

<Sysname> display clock config

Clock module current configuration:

         Work mode : auto

         SSM participate in control : no

 

Reference  Priority  SSM level Forcessm  Sa-bit  Lpu port

    1         255       UNKNOWN      yes        4        N/A

    2         255       UNKNOWN      yes        4        N/A

    3         255       UNKNOWN      N/A       N/A        -

    4         255       UNKNOWN      N/A       N/A        -

    5         255       UNKNOWN      N/A       N/A        -

    6         255       UNKNOWN      N/A       N/A        -

    7         255       UNKNOWN      N/A       N/A        -

    8         255       UNKNOWN      N/A       N/A        -

    9         255       UNKNOWN      N/A       N/A        -

   10         255       UNKNOWN      N/A       N/A        -

   11         255       UNKNOWN      N/A       N/A        -

   12         255       UNKNOWN      N/A       N/A        -

   13         255       UNKNOWN      N/A       N/A        -

   14         255       UNKNOWN      N/A       N/A        -

Table 1 Output description

Field

Description

Clock module current configuration:

Current configuration of the clock monitoring module

Work mode

Working mode of the clock monitoring module, with auto indicating the auto mode and manual indicating the manual mode.)

SSM participate in control

Whether SSM is activated

Reference

Serial number of the reference source

Priority

Priority of the reference source

SSM level

SSM level of the reference source

Forcessm

Derive mode of the SSM level, with yes meaning derived from Bits clock source and N/A meaning this function is not supported

Sa-bit

Bits used to transmit the SSM level of the Bits clock source

Lpu port

Input port of the line clock source (N/A indicates this function is not supported and semicolon (;) indicates this port is not configured)

 

display clock device

Syntax

display clock device [ | { begin | exclude | include } regular-expression ]

View

Any view

Default level

1: Monitor level

Parameters

|: Filters command output by specifying a regular expression. For more information about regular expressions, see Fundamentals Configuration Guide.

begin: Displays the first line that matches the specified regular expression and all lines that follow.

exclude: Displays all lines that do not match the specified regular expression.

include: Displays all lines that match the specified regular expression.

regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.

Description

Use the display clock device command to view detailed information for the clock monitoring module.

Examples

# View detailed information for the clock monitoring module.

<Sysname> display clock device

Clock module detail information:

 

Clock module state is OK

           SRAM state: OK

           Output 38.88Mhz signal state: OK

           PLL tru050 state: OK

           PLL 88915 state: OK

           OSC state: OK

           I2C bus state: OK

           EPLD state: OK

           HDLC state: OK

           E1 A state: OK

           E1 B state: OK

 

Reference state

           Work mode : auto

           Traced reference : 0

           Lock mode : freerun

           OSC state : normal

           SSM output level : LNC

           SSM participate in control : No

 

Reference   State   Priority  SSM-level Forcessm  Sa-bit  Lpu port

   1         lost      255     UNKNOWN      yes       4        N/A

   2         lost      255     UNKNOWN      yes       4        N/A

   3         lost      255     UNKNOWN      N/A       N/A       -

   4         lost      255     UNKNOWN      N/A       N/A       -

   5         lost      255     UNKNOWN      N/A       N/A       -

   6         lost      255     UNKNOWN      N/A       N/A       -

   7         lost      255     UNKNOWN      N/A       N/A       -

   8         lost      255     UNKNOWN      N/A       N/A       -

   9         lost      255     UNKNOWN      N/A       N/A       -

  10         lost      255     UNKNOWN      N/A       N/A       -

  11         lost      255     UNKNOWN      N/A       N/A       -

  12         lost      255     UNKNOWN      N/A       N/A       -

  13         lost      255     UNKNOWN      N/A       N/A       -

  14         lost      255     UNKNOWN      N/A       N/A       -

Table 2 Output description

Field

Description

Clock module detail information

Displays detailed information about the clock monitoring module

Clock module state

Current state of the clock monitoring module

SRAM state

State of SRAM

EPLD state

State of EPLD

E1 A state

State of E1 A

E1 B state

State of E1 B

Reference state

Reference state

Work mode

Work mode

Traced reference

Traced reference

Lock mode

Lock mode

SSM output level

SSM output level

SSM participate in control

Whether SSM is activated

Reference

Number of the reference source

State

State of the reference source

Priority

Priority of the reference source

SSM-level

SSM of the reference source

Forcessm

Whether the SSM level of the reference source is activated or not

Sa-bit

Bits used to transmit the SSM level of the Bits clock source

Lpu port

Input port of the line clock source

 

display clock lpuport

Syntax

display clock lpuport [ | { begin | exclude | include } regular-expression ]

View

Any view

Default level

1: Monitor level

Parameters

|: Filters command output by specifying a regular expression. For more information about regular expressions, see Fundamentals Configuration Guide.

begin: Displays the first line that matches the specified regular expression and all lines that follow.

exclude: Displays all lines that do not match the specified regular expression.

include: Displays all lines that match the specified regular expression.

regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.

Description

Use the display clock lpuport command to view the input port of the line clock source.

Examples

# View the input port of the line clock source.

<Sysname> display clock lpuport

The LPU port(s) which output(s) clock reference:

  Reference        Lpu port(portname)

      4             Pos3/1/1

Table 3 Output description

Field

Description

The LPU port(s) which output(s) clock reference:

Input port information of the line clock source

Reference

Serial number of the reference source

Lpu port (portname)

Input port of the line clock source (port name)

 

display clock phase-lock-state

Syntax

display clock phase-lock-state [ | { begin | exclude | include } regular-expression ]

View

Any view

Default level

1: Monitor level

Parameters

|: Filters command output by specifying a regular expression. For more information about regular expressions, see Fundamentals Configuration Guide.

begin: Displays the first line that matches the specified regular expression and all lines that follow.

exclude: Displays all lines that do not match the specified regular expression.

include: Displays all lines that match the specified regular expression.

regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.

Description

Use the display clock phase-lock-state command to view the phase lock state of the clock monitoring module.

Examples

# View the phase lock state of the clock monitoring module.

<Sysname> display clock phase-lock-state

Phase lock state: hold

Table 4 Output description

Field

Description

Phase lock state:

The phase lock state of the clock monitoring module, including free-run, lock, fast-lock, and hold

 

display clock priority

Syntax

display clock priority [ | { begin | exclude | include } regular-expression ]

View

Any view

Default level

1: Monitor level

Parameters

|: Filters command output by specifying a regular expression. For more information about regular expressions, see Fundamentals Configuration Guide.

begin: Displays the first line that matches the specified regular expression and all lines that follow.

exclude: Displays all lines that do not match the specified regular expression.

include: Displays all lines that match the specified regular expression.

regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.

Description

Use the display clock priority command to view the priority of all reference sources.

Examples

# View the priority of all reference sources.

<Sysname> display clock priority

Reference  Priority

 

     1        255

     2          4

     3        255

     4        255

     5        255

     6        255

     7        255

     8        255

     9        255

    10        255

    11        255

    12        255

    13        255

    14        255

display clock self-test-result

Syntax

display clock self-test-result [ | { begin | exclude | include } regular-expression ]

View

Any view

Default level

1: Monitor level

Parameters

|: Filters command output by specifying a regular expression. For more information about regular expressions, see Fundamentals Configuration Guide.

begin: Displays the first line that matches the specified regular expression and all lines that follow.

exclude: Displays all lines that do not match the specified regular expression.

include: Displays all lines that match the specified regular expression.

regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.

Description

Use the display clock self-test-result command to view the self-test result of the clock monitoring module.

Examples

# View the self-test result of the clock monitoring module.

<Sysname> display clock self-test-result

Clock module work mode: normal

Detail test report:

         SRAM        : normal

         EPLD        : normal

         E1a         : normal

         E1b         : normal

Table 5 Output description

Field

Description

Clock module work mode:

Work mode of the clock monitoring module

Detail test report:

Detailed test report

SRAM        :

SRAM state

EPLD        :

EPLD state

E1a         :

E1a state

E1b         :

E1b state

 

display clock source

Syntax

display clock source [ | { begin | exclude | include } regular-expression ]

View

Any view

Default level

1: Monitor level

Parameters

|: Filters command output by specifying a regular expression. For more information about regular expressions, see Fundamentals Configuration Guide.

begin: Displays the first line that matches the specified regular expression and all lines that follow.

exclude: Displays all lines that do not match the specified regular expression.

include: Displays all lines that match the specified regular expression.

regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.

Description

Use the display clock source command to view the status of all reference sources.

Examples

# View the status of all reference sources.

<Sysname> display clock source

No primary reference is traced

 Reference       State       Lpu port(portname)

 

     1            lost         N/A

     2            lost         N/A

     3            lost         -

     4            lost         -

     5            lost         -

     6            lost         -

     7            lost         -

     8            lost         -

     9            lost         -

    10            lost         -

    11            lost         -

    12            lost         -

    13            lost         -

    14            lost         -

Table 6 Output description

Field

Description

No primary reference is traced

No primary reference is traced, meaning no primary reference is manually specified.

Reference

Serial number of the clock source.

State

State of the reference source.

Lpu port (portname)

Input port of the line clock corresponding with the reference source (port name).

 

display clock ssm-level

Syntax

display clock ssm-level [ | { begin | exclude | include } regular-expression ]

View

Any view

Default level

1: Monitor level

Parameters

|: Filters command output by specifying a regular expression. For more information about regular expressions, see Fundamentals Configuration Guide.

begin: Displays the first line that matches the specified regular expression and all lines that follow.

exclude: Displays all lines that do not match the specified regular expression.

include: Displays all lines that match the specified regular expression.

regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.

Description

Use the display clock ssm-level command to view the SSM level of all reference sources.

Related commands: clock ssm.

Examples

#View the SSM level of all reference sources.

<Sysname> display clock ssm-level

Reference SSM level

 

    1        LNC

    2      UNKNOWN

    3      UNKNOWN

    4        LNC

    5      UNKNOWN

    6      UNKNOWN

    7      UNKNOWN

    8      UNKNOWN

    9      UNKNOWN

   10      UNKNOWN

   11      UNKNOWN

   12      UNKNOWN

   13      UNKNOWN

   14      UNKNOWN

In the output information, the Reference field indicates the serial number of the reference source and the SSM level field indicates the SSM level of the reference source.

display clock ssm-output

Syntax

display clock ssm-output [ | { begin | exclude | include } regular-expression ]

View

Any view

Default level

1: Monitor level

Parameters

|: Filters command output by specifying a regular expression. For more information about regular expressions, see Fundamentals Configuration Guide.

begin: Displays the first line that matches the specified regular expression and all lines that follow.

exclude: Displays all lines that do not match the specified regular expression.

include: Displays all lines that match the specified regular expression.

regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.

Description

Use the display clock ssm-output command to view the SSM level of the output clock signal.

Examples

# View the SSM level of the output clock signal.

<Sysname> display clock ssm-output

SSM output level is LNC.

display clock version

Syntax

display clock version [ | { begin | exclude | include } regular-expression ]

View

Any view

Default level

1: Monitor level

Parameters

|: Filters command output by specifying a regular expression. For more information about regular expressions, see Fundamentals Configuration Guide.

begin: Displays the first line that matches the specified regular expression and all lines that follow.

exclude: Displays all lines that do not match the specified regular expression.

include: Displays all lines that match the specified regular expression.

regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.

Description

Use the display clock version command to view clock monitoring module version.

Examples

# View clock monitoring module version.

<Sysname> display clock version

Clock module version

         Software version: v103

         Hardware version: Rev.A

         CPLD version: v001

         Release date: 2007-08-15

Table 7 Output description

Field

Description

Clock module version

Version of the clock monitoring module

Software version

Software version of the clock monitoring module

Hardware version

Hardware version of the clock monitoring module

CPLD version

CPLD version of the clock monitoring module

Release date

Release version of the clock monitoring module

 

display clock work-mode

Syntax

display clock work-mode [ | { begin | exclude | include } regular-expression ]

View

Any view

Default level

1: Monitor level

Parameters

|: Filters command output by specifying a regular expression. For more information about regular expressions, see Fundamentals Configuration Guide.

begin: Displays the first line that matches the specified regular expression and all lines that follow.

exclude: Displays all lines that do not match the specified regular expression.

include: Displays all lines that match the specified regular expression.

regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.

Description

Use the display clock work-mode command to view the working mode of the clock monitoring module.

Examples

# View the working mode of the clock monitoring module.

<Sysname> display clock work-mode

Clock working in auto mode.

The output shows that the clock monitoring module works in auto mode.

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become a Partner
  • Partner Resources
  • Partner Business Management
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网