1 Preparing for installation

Safety recommendations

WARNING

WARNING!

Only professional technical engineers are allowed to install and remove the AP and its accessories. Read the safety instructions for the AP carefully before installing or servicing it.

 

To avoid possible bodily injury and equipment damage, read the following safety recommendations before installing the AP. Note that the recommendations do not cover every possible hazardous condition.

·          Take adequate safety measures to avoid bodily injury and device damage.

·          Place the AP in a dry and flat location and take anti-slip measures.

·          Keep the AP clean and dust-free.

·          Do not place the AP in a moist area and avoid liquid intrusion.

·          Keep the AP and installation tools away from walkways.

Site preparation

Before installing the AP, examine the installation site and make sure the AP will operate in a favorable environment. Make sure the temperate and humidity at the installation site meet the requirements in Table1-1.

Table1-1 Temperature and humidity requirements

Item

Specification

Operating temperature

–10°C to +55°C (14°F to 131°F)

Storage temperature

–40°C to +70°C (–40°F to +158°F)

Operating humidity (RH), noncondensing

5% to 95%

 

Installation accessories

Figure1-1 Accessories provided with the AP

 

Installation tools

When installing the AP, you might need the following tools. Prepare the installation tools as required.

Figure1-2 Installation tools

 


2 Installing the AP

Installation flowchart

Figure2-1 Installation flowchart

 

Pre-installation tasks

Before installing the AP, perform the following tasks:

·          Connect the AP to a power source and the network. Examine the LEDs to verify that the AP is operating correctly. For information about AP LEDs, see "LEDs."

·          Make sure cable routing has been completed.

·          Use Category-5e or above twisted pair cables to connect 2.5/5 Gbps Ethernet ports and use Category-6 or above twisted pair cables to connect 10 Gbps Ethernet ports.

·          Record the MAC address and serial number at the rear of the AP for future use.

Determining the installation position

CAUTION

CAUTION:

If interface cables are routed outdoors, prepare network port lightning arresters and install them at the AP side.

 

Determine the installation position by observing the following principles:

·          Few obstacles such as wall exist between the AP and clients.

·          The AP is far away from electronic devices (such as microwave oven) that might generate radio frequency (RF) noise.

·          The AP does not hinder people’s daily work and life.

·          The place is not water seeping, water soaking, or condensing.

Mounting the AP

The AP can be installed only indoors. You can mount the AP on a wall or a ceiling.

Mounting the AP on a wall

1.        Place the mounting bracket against the wall and mark the installation holes on the wall.

Figure2-2 Marking the installation holes on the wall

 

2.        Drill holes with a diameter of 6 mm (0.24 in) and a depth of 30 mm (1.18 in) at the marked locations, as shown in Figure2-3.

Figure2-3 Drilling holes in the wall

 

3.        Insert a screw anchor into each hole, and tap the screw anchor with a rubber hammer until it is all flush with the wall surface, as shown in Figure2-4.

Figure2-4 Hammering the screw anchor into the wall

 

4.        Insert the screws through the installation holes in the mounting bracket into the holes in the wall. Fasten the screws to secure the mounting bracket to the wall, as shown in Figure2-5.

Figure2-5 Attaching the mounting bracket to the wall

 

5.        Remove the cable cover from the AP, feed cables through the cable holder, connect the cables to the AP, and then attach the cable cover to the AP. See Figure2-6.

Figure2-6 Connecting the cables to the AP

 

6.        Position the three screws on the AP into the keyhole slots in the mounting bracket and then slide the AP down until it clicks into place, as shown in Figure2-7.

Figure2-7 Attaching the AP to the mounting bracket

 

Mounting the AP on a ceiling

CAUTION

CAUTION:

The ceiling for installing the AP must be less than 18 mm (0.71 in) in thickness, and can bear a load of 5 kg (11.02 lb). If you must install the AP on a ceiling not strong enough, use boards to reinforce the ceiling.

 

To mount the AP on a ceiling:

1.        Remove the ceiling tile.

2.        Place the mounting bracket against the ceiling tile and mark the installation holes on the ceiling tile.

3.        Drill three holes with a diameter of 6 mm (0.24 in) at the marked positions, as shown in Figure2-8.

Figure2-8 Drilling holes in the ceiling tile

 

4.        Thread the pan-head screws through the installation holes in the mounting bracket and into the holes in the ceiling tile. Fasten washers and nuts at the other side of the ceiling to secure the mounting bracket to the ceiling, as shown in Figure2-9.

Figure2-9 Attaching the mounting bracket to the ceiling

 

5.        Remove the cable cover from the AP, feed cables through the cable holder, connect the cables to the AP, and then attach the cable cover to the AP.

6.        Position the three screws on the AP into the keyhole slots in the mounting bracket, as shown in Figure2-10.

Figure2-10 Attaching the AP to the mounting bracket

 

7.        Slide the AP in the opposite direction of the UP arrow until it clicks into place, as shown in Figure2-11.

Figure2-11 Securing the AP to the mounting bracket

 

8.        Verify that the AP is securely installed to prevent it from falling off.

(Optional) Removing the AP

Insert a stick-like tool with a diameter less than 5.7 mm (0.22 in) into the lock hole of the mounting bracket until you hear a click. Then slide the AP in the direction of the UP arrow and disengage the screws from the keyhole slots to remove the AP.

Figure2-12 Removing the AP

 

Connecting the AP to a power source

You can supply power to the AP by using a local power source, a power injector, or through 802.3af/802.3at/802.3bt PoE as required. Before powering the AP, make sure the power source (the local power source or the PSE) is reliably grounded.

 

Connecting a PoE power source

CAUTION

CAUTION:

The AP is to be connected only to PoE networks without routing to the outside plant.

 

IMPORTANT

IMPORTANT:

The 10GE/PoE++ port complies with 802.3af, 802.3at, and 802.3bt standards and the GE/PoE+ port complies with 802.3af and 802.3at standards.

 

To power the AP through PoE, use an Ethernet cable to connect an Ethernet port on a PoE switch to the 10GE/PoE++ port or GE/PoE+ port on the AP. You can also connect both the 10GE/PoE++ and GE/PoE+ ports to the PoE switch to provide power to the AP.

Figure2-13 Powering the AP through PoE

 

Connecting a local power source

You can use an AC/DC power adapter to connect the AP to a local power source. No power adapter is provided with the AP. Prepare one yourself as required. Table2-1 describes the power adapter specifications.

Table2-1 Power adapter specifications

Item

Specification

Input

100 VAC to 240 VAC

Output

+54 VDC  at 0.74 A

 

Figure2-14 Using a power adapter to connect the AP to a local power source

 

Connecting a power injector

CAUTION

CAUTION:

The AP is to be connected only to PoE networks without routing to the outside plant.

 

As a best practice, use the H3C ADP040-54V-PoE-GL power injector. The power injector must be ordered separately.

To power the AP by using a power injector:

1.        Connect the signal input port on the power injector to an Ethernet switch and the signal and power output port to the AP.

2.        Connect the power adapter to the power injector.

Figure2-15 Connecting a power injector

 

Check after power-on

Examine the LEDs on the AP after you power on it to verify that the AP is operating correctly. For more information about AP LEDs, see "LEDs."

Connecting the AP to the network

To connect the AP to the network, connect the 10GE/PoE++ port on the AP to an Ethernet switch.

All AP settings are configured on the AC. To verify the network connectivity of the AP, execute the display wlan ap all command on the AC. If the AP status is R/M, the AP has been connected to the network.

<AC> display wlan ap all

Total number of APs: 1

Total number of connected APs: 1

Total number of connected manual APs: 1

Total number of connected auto APs: 0

Total number of connected common APs: 1

Total number of connected WTUs: 0

Total number of inside APs: 0

Maximum supported APs: 64

Remaining APs: 63

Total AP licenses: 16

Local AP licenses: 16

Server AP licenses: 0

Remaining Local AP licenses: 15

Sync AP licenses: 0

 

                                 AP information

 State : I = Idle,      J  = Join,       JA = JoinAck,    IL = ImageLoad

         C = Config,    DC = DataCheck,  R  = Run,   M = Master,  B = Backup

 

AP name                        APID  State Model           Serial ID

ap1                            1     R/M   WA6628          219801A1Q98197E00001

 


3 Appendix A Technical specifications

Table3-1 Technical specifications

Item

Specification

Dimensions (H × W × D) (without the mounting bracket)

52 × 236 × 236 mm (2.05 × 9.29 × 9.29 in)

Weight

1300 g (45.86 oz)

System power consumption

·         ≤ 25 W (not supplying power through USB port)

·         ≤ 28 W (supplying power through USB port)

Powering option

·         802.3af/802.3at/802.3bt PoE

·         Local 54 VDC power source (by using a power adapter)

·         PoE injector

Antenna (built-in)

·         2.4 G: gain of 3 dBi

·         5 G: gain of 4 dBi

Protocol and features

·         IEEE802.11a/b/g/n/ac/ax

·         Two radios

 


4 Appendix B Ports and LEDs

Ports

The AP provides the following ports:

·          One USB port

·          One console port

·          One 10/100/1000M Ethernet copper port

·          One 100/1000/2500/5000/10000M Ethernet copper port

·          One power port

The AP also has a reset button and a security slot. The security slot is 7 × 3 mm (0.28 × 0.12 in) in size.

Figure4-1 Ports on the AP

(1) Reset button

(2) Console port

(3) USB port

(4) 100/1000/2500/5000/10000M Ethernet copper port (10GE/PoE++)

(5) 10/100/1000M Ethernet copper port (GE/PoE+)

(6) Power port

 

Table4-1 Port and button descriptions

Port

Standards and protocols

Description

Console port

RS/EIA-232

Used only for device configuration and management by technical support.

100/1000/2500/5000/10000M Ethernet copper port (10GE/PoE++)

·         IEEE802.3ab

·         IEEE802.3bz

·         IEEE802.3u

·         IEEE802.3af

·         IEEE802.3at

·         IEEE802.3bt

Used for connecting the AP to an uplink device for Internet or MAN access. It supports 802.3bt PoE++ and can receive PoE power from the uplink device.

It is represented by interface number XGE1/0/1 in the MAP file and Ten-GigabitEthernet 1 for configuration on the AC.

10/100/1000M Ethernet copper port (GE/PoE+)

·         IEEE802.3

·         IEEE802.3u

·         IEEE802.3af

·         IEEE802.3at

Used for connecting the AP to an uplink device for Internet or MAN access. It supports 802.3at PoE+ and can receive PoE power from the uplink device.

It is represented by interface number GE1/0/1 in the MAP file and GigabitEthernet 1 for configuration on the AC.

Power port (54 V)

N/A

Used for receiving +54 VDC power from the local power source.

USB port

USB 2.0

N/A

Reset button

N/A

·         To reset the AP, press and hold the button for no more than 5 seconds.

·         To restore the factory default, press and hold the button for more than 5 seconds.

 

LEDs

Table4-2 LED descriptions

LED

Status

Description

Off

No power is present or the LED has been turned off from the CLI.

Yellow

Steady on

The AP is initializing, or an initialization exception has occurred.

Flashing at 1 Hz

No radio cards have been detected.

Flashing at 2 Hz

The Ethernet interfaces have been shut down and no mesh links have been established.

Green

Steady on

The AP has started up and registered to an AC, but is in standby state (no associated clients).

Flashing at 0.5 Hz

The AP is starting up, but has not registered to an AC.

Flashing at 1 Hz

Only the 2.4G radio has associated clients.

Flashing at 2 Hz

The AP is upgrading the image.

Blue

Flashing at 1 Hz

Only the 5G radio has associated clients.

Alternating between green and blue at 1 Hz

Both the 2.4G and 5G radios have associated clients.

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become a Partner
  • Partner Resources
  • Partner Business Management
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网