15-User Access and Authentication

HomeSupportReference GuidesMIB CompanionH3C S6800 & S6860 Switch Series MIB Companion-Release 671x-6W10015-User Access and Authentication
07-IEEE8021-SECY-MIB
Title Size Download
07-IEEE8021-SECY-MIB 67.17 KB

IEEE8021-SECY-MIB

About this MIB

Use this MIB to manage MACsec.

MIB file name

ieee8021-secy.mib

Root object

iso(1).std(0).iso8802(8802).ieee802dot1(1).ieee802dot1mibs(1).ieee8021SecyMIB(3)

Tabular objects

secyIFTable

About this table

Use this table to configure or obtain information about MACsec-enabled interfaces.

Support for operations

Create

Edit/Modify

Delete

Read

Not supported

Supported

Not supported

Supported

Columns

The table index is secyIfInterfaceIndex.

Table OID: 1.0.8802.1.1.3.1.1.1.

Object (OID)

Access

Syntax

Value range

Description

Implementation

secyIfInterfaceIndex (1.0.8802.1.1.3.1.1.1.1)

not-accessible

InterfaceIndex

Integer32 (1..2147483647)

An interface index for a port with SecY management ability.

As per the MIB.

secyIfMaxPeerSCs (1.0.8802.1.1.3.1.1.1.2)

read-only

Unsigned32

Standard MIB values.

Maximum number of peer SCs that this SecY can support.

Not supported.

secyIfRxMaxKeys (1.0.8802.1.1.3.1.1.1.3)

read-only

Unsigned32

Standard MIB values.

Maximum number of keys in simultaneous use for reception that this SecY can support.

Not supported.

secyIfTxMaxKeys (1.0.8802.1.1.3.1.1.1.4)

read-only

Unsigned32

Standard MIB values.

Maximum number of keys in simultaneous use for transmission that this SecY can support.

Not supported.

secyIfProtectFramesEnable (1.0.8802.1.1.3.1.1.1.5)

read-write

TruthValue

true(1),

false(2)

An object to enable or disable the protection function for egress frames.

Supports only the read operation.

secyIfValidateFrames (1.0.8802.1.1.3.1.1.1.6)

read-write

INTEGER

disabled(1),

check(2),

strict(3)

An object to control the validation function for ingress frames.

Default: strict.

secyIfReplayProtectEnable (1.0.8802.1.1.3.1.1.1.7)

read-write

TruthValue

true(1),

false(2)

An object to enable or disable the replay protection function.

Supports only the read operation.

secyIfReplayProtectWindow (1.0.8802.1.1.3.1.1.1.8)

read-write

Unsigned32

Standard MIB values.

Replay protection window size, in frames.

Supports only the read operation.

secyIfCurrentCipherSuite (1.0.8802.1.1.3.1.1.1.9)

read-write

Unsigned32

Standard MIB values.

An object that points to an entry of the secyCipherSuiteTable with active row status to indicate the cipher suite that this SecY is currently using.

Not supported.

secyIfAdminPt2PtMAC (1.0.8802.1.1.3.1.1.1.10)

read-only

INTEGER

forceTrue(1),

forceFalse(2),

auto(3)

An object to control the service connectivity to at most one other system.

Not supported.

secyIfOperPt2PtMAC

(1.0.8802.1.1.3.1.1.1.11)

read-only

TruthValue

true(1),

false(2)

An object to reflect the current service connectivity status.

Not supported.

secyIfIncludeSCIEnable (1.0.8802.1.1.3.1.1.1.12)

read-write

TruthValue

true(1),

false(2)

An object indicates whether to include the SCI information in security TAG (SecTAG) field while transmitting MACsec frames.

Not supported.

secyIfUseESEnable (1.0.8802.1.1.3.1.1.1.13)

read-write

TruthValue

true(1),

false(2)

An object indicates whether to enable the ES bit in security TAG (SecTAG) field while transmitting MACsec frames.

Not supported.

secyIfUseSCBEnable (1.0.8802.1.1.3.1.1.1.14)

read-write

TruthValue

true(1),

false(2)

An object indicates whether to enable the SCB bit in security TAG (SecTAG) field while transmitting MACsec frames.

Not supported.

 

secyTxSCTable

About this table

Use this table to obtain information about transmitting SCs.

Support for operations

Create

Edit/Modify

Delete

Read

Not supported

Not supported

Not supported

Supported

Columns

The table index is secyIfInterfaceIndex.

 

Object (OID)

Access

Syntax

Value range

Description

Implementation

secyTxSCI (1.0.8802.1.1.3.1.1.2.1.1)

read-only

SecySCI

OCTET STRING (0..65535)

SCI for transmitting MACsec frames of a transmitting SC in a SecY.

The read operation is returned a value only when MACsec is enabled on the port that holds the transmitting SC.

secyTxSCState (1.0.8802.1.1.3.1.1.2.1.2)

read-only

INTEGER

inUse(1),

notInUse(2)

State of the current transmitting SC in the SecY.

Not supported.

secyTxSCEncodingSA (1.0.8802.1.1.3.1.1.2.1.3)

read-only

RowPointer

Standard MIB values.

Current transmitting SA in use.

The read operation is returned a value only when MACsec is enabled on the port that holds the transmitting SC.

secyTxSCEncipheringSA (1.0.8802.1.1.3.1.1.2.1.4)

read-only

RowPointer

Standard MIB values.

Previous transmitting SA in use.

The read operation is returned a value only when MACsec is enabled on the port that holds the transmitting SC.

secyTxSCCreatedTime (1.0.8802.1.1.3.1.1.2.1.5)

read-only

TimeStamp

Standard MIB values.

System time when the transmitting SC was created.

Not supported.

secyTxSCStartedTime (1.0.8802.1.1.3.1.1.2.1.6)

read-only

TimeStamp

Standard MIB values.

System time when the transmitting SC last started transmitting MACsec frames.

Not supported.

secyTxSCStoppedTime (1.0.8802.1.1.3.1.1.2.1.7)

read-only

TimeStamp

Standard MIB values.

System time when the transmitting SC last stopped transmitting MACsec frames.

Not supported.

 

secyTXSATable

About this table

Use this table to obtain information about transmitting SAs.

Support for operations

Create

Edit/Modify

Delete

Read

Not supported

Not supported

Not supported

Supported

 

Columns

The table indexes are secyIfInterfaceIndex and secyTxSA.

Table OID:1.0.8802.1.1.3.1.1.3.

 

Object (OID)

Access

Syntax

Value range

Description

Implementation

secyTxSA (1.0.8802.1.1.3.1.1.3.1.1)

not-accessible

SecyAN

Unsigned32(0..4294967295)

Association number (AN) for identifying a transmitting SA.

As per the MIB.

secyTxSAState (1.0.8802.1.1.3.1.1.3.1.2) 

read-only

INTEGER

inUse(1),

notInUse(2)

Current status of the transmitting SA.

Not supported.

secyTxSANextPN (1.0.8802.1.1.3.1.1.3.1.3) 

read-only

Unsigned32

Unsigned32 (0..4294967295)

Next packet number (PN) that will be used in transmitting MACsec frames in the SA.

Supports only the read operation.

The read operation is returned a value only when MACsec is enabled on the port that holds the transmitting SA.

secyTxSAConfidentiality (1.0.8802.1.1.3.1.1.3.1.4) 

read-only

TruthValue

true(1),

false(2)

Whether the SA supports the confidentiality as well as integrity function in transmitting frames.

Not supported.

secyTxSASAKUnchanged (1.0.8802.1.1.3.1.1.3.1.5) 

read-only

TruthValue

true(1),

false(2)

A reference to an SAK that is unchanged for the life of the transmitting SA.

Not supported.

secyTxSACreatedTime (1.0.8802.1.1.3.1.1.3.1.6) 

read-only

TimeStamp

Standard MIB values.

System time when the transmitting SA was created.

Not supported.

secyTxSAStartedTime (1.0.8802.1.1.3.1.1.3.1.7)

read-only

TimeStamp

Standard MIB values.

System time when the transmitting SA last started transmitting MACsec frames.

Not supported.

SecyTxSAStoppedTime

(1.0.8802.1.1.3.1.1.3.1.8)

read-only

TimeStamp

Standard MIB values.

System time when the transmitting SA last stopped transmitting MACsec frames.

Not supported.

 

secyRxSCTable

About this table

Use this table to obtain information about receiving SCs.

Support for operations

Create

Edit/Modify

Delete

Read

Not supported

Not supported

Not supported

Supported

 

Columns

The table indexes are secyIfInterfaceIndex and secyRxSCI.

Object (OID)

Access

Syntax

Value range

Description

Implementation

secyRxSCI (1.0.8802.1.1.3.1.1.4.1.1)

not-accessible

SecySCI

OCTET STRING (0..65535)

SCI for identifying a receiving SC in a SecY.

As per the MIB.

secyRxSCState (1.0.8802.1.1.3.1.1.4.1.2)

read-only

INTEGER

inUse(1),

notInUse(2)

State of the receiving SC in the SecY.

Not supported.

secyRxSCCurrentSA (1.0.8802.1.1.3.1.1.4.1.3)

read-only

RowPointer

Standard MIB values.

Current receiving association number of the SC in use.

The read operation is returned a value only when MACsec is enabled on the port that holds the receiving SC.

secyRxSCCreatedTime (1.0.8802.1.1.3.1.1.4.1.4)

read-only

TimeStamp

Standard MIB values.

System time when the receiving SC was created.

Not supported.

secyRxSCStartedTime (1.0.8802.1.1.3.1.1.4.1.5)

read-only

TimeStamp

Standard MIB values.

System time when the receiving SC last started receiving MACsec frames.

Not supported.

secyRxSCStoppedTime (1.0.8802.1.1.3.1.1.4.1.6)

read-only

TimeStamp

Standard MIB values.

System time when the receiving SC last stopped receiving MACsec frames.

Not supported.

 

secyRxSATable

About this table

Use this table to obtain information about receiving SAs.

Support for operations

Create

Edit/Modify

Delete

Read

Not supported

Not supported

Not supported

Supported

 

Columns

The table indexes are secyIfInterfaceIndex and secyRxSCI.

 

Object (OID)

Access

Syntax

Value range

Description

Implementation

secyRxSA (1.0.8802.1.1.3.1.1.5.1.1)

not-accessible

SecyAN

Standard MIB values.

Association number (AN) for identifying a receiving SA.

As per the MIB.

secyRxSAState (1.0.8802.1.1.3.1.1.5.1.2)

read-only

INTEGER

inUse(1), notInUse(2)

Current state for the receiving SA.

Not supported.

secyRxSANextPN (1.0.8802.1.1.3.1.1.5.1.3)

read-write

Unsigned32

Standard MIB values.

Stored packet number (PN) for replay protection in the SA.

Supports only the read operation.

The read operation is returned a value only when MACsec is enabled on the port that holds the receiving SA.

secyRxSASAKUnchanged (1.0.8802.1.1.3.1.1.5.1.4)

read-only

TruthValue

true(1),

false(2)

A reference to an SAK that is unchanged for the life of the receiving SA.

Not supported.

secyRxSACreatedTime (1.0.8802.1.1.3.1.1.5.1.5)

read-only

TimeStamp

Standard MIB values.

System time when the receiving SA was created.

Not supported.

secyRxSAStartedTime (1.0.8802.1.1.3.1.1.5.1.6)

read-only

TimeStamp

Standard MIB values.

System time when the receiving SA last started receiving MACsec frames.

Not supported.

SecyRxSAStoppedTime

(1.0.8802.1.1.3.1.1.5.1.7)

read-only

TimeStamp

Standard MIB values.

System time when the receiving SA last stopped  receiving MACsec frames.

Not supported.

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become a Partner
  • Partner Resources
  • Partner Business Management
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网