HH3C-TRANSCEIVER-INFO-MIB

About this MIB

Use this MIB to obtain information about transceiver modules, including vendor information and physical transmission characteristics.

MIB file name

hh3c-transceiver-info.mib

Root object

iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).hh3c(25506).hh3cCommon(2).hh3cTransceiver(70)

Tabular objects

hh3cTransceiverInfoTable

About this table

Use this table to obtain information about transceiver modules.

Support for operations

Create

Edit/Modify

Delete

Read

Not supported

Supported

Not supported

Supported

Columns

The table index is ifIndex.

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cTransceiverHardwareType (1.3.6.1.4.1.25506.2.70.1.1.1.1)

read-only

OCTET STRING

Standard MIB values.

Hardware type of the transceiver module, such as single mode (SM).

As per the MIB.

hh3cTransceiverType (1.3.6.1.4.1.25506.2.70.1.1.1.2)

read-only

OCTET STRING

Standard MIB values.

Type of the transceiver module, such as SFP.

As per the MIB.

hh3cTransceiverWaveLength (1.3.6.1.4.1.25506.2.70.1.1.1.3)

read-only

Integer32

Standard MIB values.

Wavelength of the transceiver module, in nm.

As per the MIB.

hh3cTransceiverVendorName (1.3.6.1.4.1.25506.2.70.1.1.1.4)

read-only

OCTET STRING

Standard MIB values.

Vendor name of the transceiver module.

As per the MIB.

hh3cTransceiverSerialNumber (1.3.6.1.4.1.25506.2.70.1.1.1.5)

read-only

OCTET STRING

Standard MIB values.

Serial number of the transceiver module.

As per the MIB.

hh3cTransceiverFiberDiameterType (1.3.6.1.4.1.25506.2.70.1.1.1.6)

read-only

INTEGER

fiber9(1),
fiber50(2),
fiber625(3),
copper(4),
unknown(65535)

Fiber diameter for the transceiver module, in microns (μm).

As per the MIB.

hh3cTransceiverTransferDistance (1.3.6.1.4.1.25506.2.70.1.1.1.7)

read-only

Integer32

Standard MIB values.

Maximum transmission distance of the transceiver module, in meters.

As per the MIB.

hh3cTransceiverDiagnostic (1.3.6.1.4.1.25506.2.70.1.1.1.8)

read-only

TruthValue

true(1),
false(2)

Whether the transceiver module supports digital diagnosis.

As per the MIB.

hh3cTransceiverCurTXPower (1.3.6.1.4.1.25506.2.70.1.1.1.9)

read-only

Integer32

Standard MIB values.

Current transmit power of the transceiver module, in dBm, accurate to 0.01 dBm.

The object returns 2147483647 when read if the device does not support this parameter.

hh3cTransceiverMaxTXPower (1.3.6.1.4.1.25506.2.70.1.1.1.10)

read-only

Integer32

Standard MIB values.

Maximum transmit power of the transceiver module, in dBm, accurate to 0.01 dBm.

The object returns 2147483647 when read if the device does not support this parameter.

hh3cTransceiverMinTXPower (1.3.6.1.4.1.25506.2.70.1.1.1.11)

read-only

Integer32

Standard MIB values.

Minimum transmit power of the transceiver module, in dBm, accurate to 0.01 dBm.

The object returns 2147483647 when read if the device does not support this parameter.

hh3cTransceiverCurRXPower (1.3.6.1.4.1.25506.2.70.1.1.1.12)

read-only

Integer32

Standard MIB values.

Current receive power in dBm of the transceiver module, accurate to 0.01 dBm.

The object returns 2147483647 when read if the device does not support this parameter.

hh3cTransceiverMaxRXPower (1.3.6.1.4.1.25506.2.70.1.1.1.13)

read-only

Integer32

Standard MIB values.

Maximum receive power of the transceiver module, in dBm, accurate to 0.01 dBm.

The object returns 2147483647 when read if the device does not support this parameter.

hh3cTransceiverMinRXPower (1.3.6.1.4.1.25506.2.70.1.1.1.14)

read-only

Integer32

Standard MIB values.

Minimum receive power of the transceiver module, in dBm, accurate to 0.01 dBm.

The object returns 2147483647 when read if the device does not support this parameter.

hh3cTransceiverTemperature (1.3.6.1.4.1.25506.2.70.1.1.1.15)

read-only

Integer32

Standard MIB values.

Current temperature of the transceiver module, in °C.

As per the MIB.

hh3cTransceiverVoltage (1.3.6.1.4.1.25506.2.70.1.1.1.16)

read-only

Integer32

Standard MIB values.

Current voltage of the transceiver module, in V, accurate to 0.01 V.

As per the MIB.

hh3cTransceiverBiasCurrent (1.3.6.1.4.1.25506.2.70.1.1.1.17)

read-only

Integer32

Standard MIB values.

Current bias current of the transceiver module, in mA, accurate to 0.01 mA.

As per the MIB.

hh3cTransceiverTempHiAlarm (1.3.6.1.4.1.25506.2.70.1.1.1.18)

read-only

Integer32

Standard MIB values.

High temperature alarm threshold in °C, accurate to 0.001 °C , for example, 49120 representing 49.120 °C

As per the MIB.

hh3cTransceiverTempLoAlarm (1.3.6.1.4.1.25506.2.70.1.1.1.19)

read-only

Integer32

Standard MIB values.

Low temperature alarm threshold in °C, accurate to 0.001 °C

As per the MIB.

hh3cTransceiverTempHiWarn (1.3.6.1.4.1.25506.2.70.1.1.1.20)

read-only

Integer32

Standard MIB values.

High temperature warning threshold in °C, accurate to 0.001 °C

As per the MIB.

hh3cTransceiverTempLoWarn (1.3.6.1.4.1.25506.2.70.1.1.1.21)

read-only

Integer32

Standard MIB values.

Low temperature warning threshold in °C, accurate to 0.001 °C

As per the MIB.

hh3cTransceiverVccHiAlarm (1.3.6.1.4.1.25506.2.70.1.1.1.22)

read-only

Integer32

Standard MIB values.

High voltage alarm threshold in µV, accurate to 0.01 µV.

As per the MIB.

This object returns 0 when read if the transceiver module does not support this parameter.

hh3cTransceiverVccLoAlarm (1.3.6.1.4.1.25506.2.70.1.1.1.23)

read-only

Integer32

Standard MIB values.

Low voltage alarm threshold in µV, accurate to 0.01 µV.

As per the MIB.

This object returns 0 when read if the transceiver module does not support this parameter.

hh3cTransceiverVccHiWarn (1.3.6.1.4.1.25506.2.70.1.1.1.24)

read-only

Integer32

Standard MIB values.

High voltage warning threshold in µV, accurate to 0.01 µV.

As per the MIB.

This object returns 0 when read if the transceiver module does not support this parameter.

hh3cTransceiverVccLoWarn (1.3.6.1.4.1.25506.2.70.1.1.1.25)

read-only

Integer32

Standard MIB values.

Low voltage warning threshold in mV, accurate to 0.01 µV.

As per the MIB.

This object returns 0 when read if the transceiver module does not support this parameter.

hh3cTransceiverBiasHiAlarm (1.3.6.1.4.1.25506.2.70.1.1.1.26)

read-only

Integer32

Standard MIB values.

High bias current alarm threshold in µA.

As per the MIB.

This object returns 0 when read if the transceiver module does not support this parameter.

hh3cTransceiverBiasLoAlarm (1.3.6.1.4.1.25506.2.70.1.1.1.27)

read-only

Integer32

Standard MIB values.

Low bias current alarm threshold in µA.

As per the MIB.

This object returns 0 when read if the transceiver module does not support this parameter.

hh3cTransceiverBiasHiWarn (1.3.6.1.4.1.25506.2.70.1.1.1.28)

read-only

Integer32

Standard MIB values.

High bias current warning threshold in µA.

As per the MIB.

This object returns 0 when read if the transceiver module does not support this parameter.

hh3cTransceiverBiasLoWarn (1.3.6.1.4.1.25506.2.70.1.1.1.29)

read-only

Integer32

Standard MIB values.

Low bias current warning threshold in µA.

As per the MIB.

This object returns 0 when read if the transceiver module does not support this parameter.

hh3cTransceiverPwrOutHiAlarm (1.3.6.1.4.1.25506.2.70.1.1.1.30)

read-only

Integer32

Standard MIB values.

High transmit power alarm threshold in µW, accurate to 0.1 µW.

As per the MIB.

This object returns 0 when read if the transceiver module does not support this parameter.

hh3cTransceiverPwrOutLoAlarm (1.3.6.1.4.1.25506.2.70.1.1.1.31)

read-only

Integer32

Standard MIB values.

Low transmit power alarm threshold in µW, accurate to 0.1 µW.

As per the MIB.

This object returns 0 when read if the transceiver module does not support this parameter.

hh3cTransceiverPwrOutHiWarn (1.3.6.1.4.1.25506.2.70.1.1.1.32)

read-only

Integer32

Standard MIB values.

High transmit power warning threshold in µW, accurate to 0.1 µW.

As per the MIB.

This object returns 0 when read if the transceiver module does not support this parameter.

hh3cTransceiverPwrOutLoWarn (1.3.6.1.4.1.25506.2.70.1.1.1.33)

read-only

Integer32

Standard MIB values.

Low transmit power warning threshold in µW, accurate to 0.1 µW.

As per the MIB.

This object returns 0 when read if the transceiver module does not support this parameter.

hh3cTransceiverRcvPwrHiAlarm (1.3.6.1.4.1.25506.2.70.1.1.1.34)

read-only

Integer32

Standard MIB values.

High receive power alarm threshold in µW, accurate to 0.1 µW.

As per the MIB.

This object returns 0 when read if the transceiver module does not support this parameter.

hh3cTransceiverRcvPwrLoAlarm (1.3.6.1.4.1.25506.2.70.1.1.1.35)

read-only

Integer32

Standard MIB values.

Low receive power alarm threshold in µW, accurate to 0.1 µW.

As per the MIB.

This object returns 0 when read if the transceiver module does not support this parameter.

hh3cTransceiverRcvPwrHiWarn (1.3.6.1.4.1.25506.2.70.1.1.1.36)

read-only

Integer32

Standard MIB values.

High receive power warning threshold in µW, accurate to 0.1 µW.

As per the MIB.

This object returns 0 when read if the transceiver module does not support this parameter.

hh3cTransceiverRcvPwrLoWarn (1.3.6.1.4.1.25506.2.70.1.1.1.37)

read-only

Integer32

Standard MIB values.

Low receive power warning threshold in µW, accurate to 0.1 µW.

As per the MIB.

This object returns 0 when read if the transceiver module does not support this parameter.

hh3cTransceiverErrors (1.3.6.1.4.1.25506.2.70.1.1.1.38)

read-only

BITS

BITS {
xcvrIOError(0),
xcvrChecksum(1),
xcvrTypeAndPortConfigMismatch(2),
xcvrTypeNotSupported(3),
wisLocalFault(4),
rcvOpticalPowerFault(5),
pmapmdReceiverLocalFault(6),
pcsReceiveLocalFault(7),
phyXSReceiveLocalFault(8),
laserBiasCurrentFault(9),
laserTemperatureFault(10),
laserOutputPowerFault(11),
txFault(12),
pmapmdTransmitterLocalFault(13),
pcsTransmitLocalFault(14),
phyXSTransmitLocalFault(15),
rxLossOfSignal(16),
tecError(17),
wavelengthUnlocked(18),
txIsNotReadyDueToTuning(19) ,

Unused(20-31)
}

Error information about the transceiver module.

As per the MIB.

hh3cTransceiverVendorOUI (1.3.6.1.4.1.25506.2.70.1.1.1.39)

read-only

SnmpAdminString

OCTET STRING (0..255)

Vendor OUI of the transceiver module.

As per the MIB.

hh3cTransceiverRevisionNumber (1.3.6.1.4.1.25506.2.70.1.1.1.40)

read-only

SnmpAdminString

OCTET STRING (0..255)

Revision number of the transceiver module.

As per the MIB.

hh3cTransceiverFrequency (1.3.6.1.4.1.25506.2.70.1.1.1.41)

read-only

Integer32

Standard MIB values.

Frequency of the current ITU channel, in THz, accurate to 0.01 THz.

As per the MIB.

hh3cTransceiverActiveITUChannel (1.3.6.1.4.1.25506.2.70.1.1.1.42)

read-write

Unsigned32

Unsigned32 (1.. 4294967295)

Index of the current ITU channel.

As per the MIB.

hh3cTransceiverCurWaveErr (1.3.6.1.4.1.25506.2.70.1.1.1.43)

read-only

Integer32

Standard MIB values.

Wavelength offset of the current ITU channel, in nm, accurate to 0.001 nm.

As per the MIB.

hh3cTransceiverWaveErrHiAlarm (1.3.6.1.4.1.25506.2.70.1.1.1.44)

read-only

Integer32

Standard MIB values.

High wavelength offset alarm threshold for the current ITU channel, in nm, accurate to 0.001 nm..

As per the MIB.

hh3cTransceiverWaveErrLoAlarm (1.3.6.1.4.1.25506.2.70.1.1.1.45)

read-only

Integer32

Standard MIB values.

Low wavelength offset alarm threshold for the current ITU channel, in nm, accurate to 0.001 nm.

As per the MIB.

hh3cTransceiverCurFreqErr (1.3.6.1.4.1.25506.2.70.1.1.1.46)

read-only

Integer32

Standard MIB values.

Frequency offset of the current ITU channel, in GHz, accurate to 0.1 GHz.

As per the MIB.

hh3cTransceiverFreqErrHiAlarm (1.3.6.1.4.1.25506.2.70.1.1.1.47)

read-only

Integer32

Standard MIB values.

High frequency offset alarm threshold for the current ITU channel, in GHz, accurate to 0.1 GHz.

As per the MIB.

hh3cTransceiverFreqErrLoAlarm (1.3.6.1.4.1.25506.2.70.1.1.1.48)

read-only

Integer32

Standard MIB values.

Low frequency offset alarm threshold for the current ITU channel, in GHz, accurate to 0.1 GHz.

As per the MIB.

hh3cTransceiverPartNumber (1.3.6.1.4.1.25506.2.70.1.1.1.49)

read-only

OCTET STRING

Standard MIB values.

Part number of the transceiver module.

As per the MIB.

hh3cTransceiverProductCode (1.3.6.1.4.1.25506.2.70.1.1.1.50)

read-only

OCTET STRING

Standard MIB values.

Product code of the transceiver module.

As per the MIB.

hh3cTransceiverOriginalSN (1.3.6.1.4.1.25506.2.70.1.1.1.51)

read-only

OCTET STRING

Standard MIB values.

Original serial number of the transceiver module.

As per the MIB.

 

hh3cTransceiverChannelTable

About this table

Use this table to obtain statistics about channels of a transceiver module.

Support for operations

Create

Edit/Modify

Delete

Read

Not supported

Not supported

Not supported

Supported

Columns

The table indexes are ifIndex and hh3cTransceiverChannelIndex.

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cTransceiverChannelIndex (1.3.6.1.4.1.25506.2.70.1.2.1.1)

not-accessible

Integer32

Integer32 (1..2147483647)

Transceiver module channel index.

As per the MIB.

hh3cTransceiverChannelCurTXPower (1.3.6.1.4.1.25506.2.70.1.2.1.2)

read-only

Integer32

Standard MIB values.

Current transmit power in dBm, accurate to 0.01 dBm.

This object returns 2147483647 when read if this parameter is not supported.

hh3cTransceiverChannelCurRXPower (1.3.6.1.4.1.25506.2.70.1.2.1.3)

read-only

Integer32

Standard MIB values.

Current receiver power in dBm, accurate to 0.01 dBm.

This object returns 2147483647 when read if this parameter is not supported.

hh3cTransceiverChannelTemperature (1.3.6.1.4.1.25506.2.70.1.2.1.4)

read-only

Integer32

Standard MIB values.

Current temperature in °C.

This object returns 2147483647 when read if this parameter is not supported.

hh3cTransceiverChannelBiasCurrent (1.3.6.1.4.1.25506.2.70.1.2.1.5)

read-only

Integer32

Standard MIB values.

Current bias current in mA, accurate to 0.01 mA.

This object returns 2147483647 when read if this parameter is not supported.

hh3cTransceiverChannelBiasHiAm

(1.3.6.1.4.1.25506.2.70.1.2.1.6)

read-only

Integer32

Standard MIB values.

High bias current alarm threshold in µA.

As per the MIB.

hh3cTransceiverChannelBiasLoAm

(1.3.6.1.4.1.25506.2.70.1.2.1.7)

read-only

Integer32

Standard MIB values.

Low bias current alarm threshold in µA.

As per the MIB.

hh3cTransceiverChannelTXPwrHiAm

(1.3.6.1.4.1.25506.2.70.1.2.1.8)

read-only

Integer32

Standard MIB values.

High transmit power alarm threshold in dBm, accurate to 0.01 dBm.

As per the MIB.

hh3cTransceiverChannelTXPwrLoAm

(1.3.6.1.4.1.25506.2.70.1.2.1.9)

read-only

Integer32

Standard MIB values.

Low transmit power alarm threshold in dBm, accurate to 0.01 dBm.

As per the MIB.

 

hh3cTransceiverITUChanTable

About this table

Use this table to obtain information about ITU channels supported on the transceiver module on an interface.

Support for operations

Create

Edit/Modify

Delete

Read

Not supported

Not supported

Not supported

Supported

 

Columns

The table indexes are ifIndex and hh3cTransceiverITUChanIdx.

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cTransceiverITUChanIdx (1.3.6.1.4.1.25506.2.70.1.3.1.1)

not-accessible

Unsigned32

Unsigned32 (1.. 4294967295)

Index of an ITU channel on the transceiver module.

As per the MIB.

hh3cTransceiverITUChanFreq (1.3.6.1.4.1.25506.2.70.1.3.1.2)

read-only

Integer32

Standard MIB values.

Frequency of the ITU channel, in THz, accurate to 0.01 THz.

As per the MIB.

hh3cTransceiverITUChanWaveLth (1.3.6.1.4.1.25506.2.70.1.3.1.3)

read-only

Integer32

Standard MIB values.

Wavelength of the ITU channel, in pm.

As per the MIB.

 

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become a Partner
  • Partner Resources
  • Partner Business Management
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网