Version:1.69.02(2024/4/24)
Upgrade recommendations
Recommended Upgrade
Problems Solved
Resolved problems in HDM2-1.69.02
Symptom: On the R4950 G6 server with HDM2-1.69.01, when the ipmi power cycle command is executed repeatedly to perform restart tests, the server might fail to power on automatically.
Condition: This symptom might occur if the ipmi power cycle command is executed repeatedly to perform restart tests when the R4950 G6 server use HDM2-1.69.01.
New Functions
Upgrade recommendations
Recommended Upgrade
Problems Solved
Resolved problems in HDM2-1.69.01
202403300035
Symptom: When the R4950 G6 server uses HDM2-1.69 or an earlier version with BIOS-6.30.27P01, BIOS-6.30.29, or a later version, HDM cannot obtain information on memory temperature, voltage, or current.
Condition: This symptom might occur when the R4950 G6 server uses HDM2-1.69 or an earlier version with BIOS-6.30.27P01, BIOS-6.30.29, or a later version.
New Functions
Upgrade recommendations
Recommended Upgrade
Problems Solved
Resolved problems in HDM2-1.69
Symptom: A memory leakage might occur if you configure BIOS options in an out-of-band manner for the server.
Condition: This symptom might occur if you configure BIOS options in an out-of-band manner for the server.
Symptom: After you install the license and configure Kerberos settings, downgrading HDM to versions 1.61 earlier with configuration reserved might result in Web access issues.
Condition: This symptom might occur if you downgrade HDM to versions 1.61 earlier with configuration reserved after you install the license and configure Kerberos settings
New Functions
Upgrade recommendations
Recommended Upgrade
Problems Solved
Resolved problems in HDM2-1.68.01
Symptom: When you access HDM2 via the browser, the browser gets stuck and HDM is inaccessible.
Condition: This symptom might occur if hardware interrupts are triggered continuously on HDM2 from the host side.
Symptom: SNMP v3 traps cannot be displayed on some monitoring platforms after the server has been running for 497 days.
Condition: This symptom might occur if SNMP v3 traps are sent after the server has been running for 497 days.
Symptom: A memory leakage might occur after you configure BIOS options on HDM for the server
Condition: This symptom might occur if you configure BIOS options on HDM for the server.
New Functions
Upgrade recommendations
Recommended Upgrade
Problems Solved
Resolved problems in HDM2-1.67.01
Symptom: In HDM2-1.67 version for the server, when HDM continuously receives URLs with special characters, the webpage becomes inaccessible.
Condition: This symptom might occur if the server uses HDM2-1.67 and HDM continuously receives URLs with special characters.
New Functions
Upgrade recommendations
Recommended Upgrade
Problems Solved
Resolved problems in HDM2-1.66
202312062025
Symptom: After you downgrade HDM from version 1.65 to 1.26 or below by restoring factory defaults, HDM will fail to start. In this case, you need to replace the BMC card.
Condition: This symptom might occur if you downgrade HDM from version 1.65 to 1.26 or below by restoring factory defaults
202312061488
Symptom: When you launch H5 KVM on the HDM Web interface, a message might occur indicating that the network connection gets lost and the system is attempting to reconnect the network.
Condition: This symptom might occur if you launch H5 KVM on the HDM Web interface.
202307131020
Symptom: When you intermittently copy files or execute a DC reboot during the image mounting on H5 KVM, an image disconnection might occur.
Condition: This symptom might occur if you mount an image on H5 KVM.
202311301534
Symptom: When the R5300 G6 is installed with L40S GPUs, the power of some GPUs is displayed as N/A.
Condition: This symptom might occur if the R5300 G6 is installed with L40S GPUs in slots 2, 7, 9, and 11, or slots 7, 9, 11, and 12.
202312040333
Symptom: After you add a device via unified control on HDM, and downgrade HDM2-1.65 or HDM2-1.64 with configuration retained to HDM2-1.63 or earlier, unified control is not available.
Condition: This symptom might occur if you downgrade HDM2-1.65 or HDM2-1.64 with configuration retained to HDM2-1.63 or earlier.
New Functions
Upgrade recommendations
Recommended Upgrade
Problems Solved
Resolved problems in HDM2-1.25
Symptom: Using the iHDT scandump feature on the R4950 G6 server can cause HDM to crash and restart.
Condition: This symptom might occur if you use the iHDT scandump feature on the R4950 G6 server.
Symptom: When you use UniSystem for batch operating system installation, the processing time may be long.
Condition: This symptom might occur if you use UniSystem for batch operating system installation.
New Functions
Upgrade recommendations
Recommended Upgrade
Problems Solved
Resolved problems in HDM2-1.24
Symptom: False alarms for secondary power supply are generated when the R4950 G6 uses the new BMC version together with CPLD of an old version.
Condition: This symptom might occur if the R4950 G6 uses HDM2-1.23 and CPLD of a version earlier than V004.
Symptom: When presence errors occur on the LSI storage controller, HDM does not report alarms.
Condition: This symptom might occur after an alarm is triggered if an LSI storage controller is used with any server configuration.
Symptom: The LSI storage controller has not obtained supercapacitor information but reports supercapacitor absence mistakenly.
Condition: This symptom might occur when an LSI storage controller is used with any server configuration.
New Functions