- Table of Contents
- Related Documents
-
Title | Size | Download |
---|---|---|
02-FRUs and Compatibility Matrixes | 276.63 KB |
2 FRUs and compatibility matrixes
For the transceiver modules and cables available for the modules, see H3C S12500G-AF Switch Series Cards and Transceiver Modules Compatibility Matrixes.
IMPORTANT: · Type-S modules include Type-S MPUs (for example, LSXM1SUPS2), Type-S fabric modules (for example, LSXM1SFS08D2), and Type-S service modules (for example, LSXM1TGS48SE2). A Type-S module can be used together only with another Type-S module. You cannot install a Type-S module and a module of another type on the same switch. · Type-T modules include Type-T MPUs (for example, LSXM2SUPT2), Type-T fabric modules (for example, LSXM2SFT08E2), and Type-T service modules (for example, LSXM1TGS48TE2). A Type-T module can be used together only with another Type-T module. You cannot install a Type-T module and a module of another type on the same switch. |
MPUs
The switch uses an MPU for control and management. You can install one MPU, or two MPUs for redundancy on the switch. Do not install MPUs of different models on the same switch.
Table2-1 Type-T MPU ordering guide
Switch model |
Available MPUs |
S12516G-AF |
LSXM2SUPT2 |
S12508G-AF |
LSXM2SUPT2 |
S12504G-AF |
LSXM1SUP04T2 |
Table2-2 Type-S MPU ordering guide
Switch model |
Available MPUs |
S12516G-AF |
LSXM3SUPS2 |
S12508G-AF |
LSXM1SUPS2 LSXM3SUPS2 |
S12504G-AF |
LSXM3SUP04S2 |
Table2-3 Type-T MPU specifications
Item |
LSXM2SUPT2 |
LSXM1SUP04T2 |
Processor |
Quad core, 2.2 GHz |
Quad core, 2.2 GHz |
SDRAM |
16 GB |
16 GB |
Flash |
4 GB |
8 GB |
NVRAM |
512 KB |
512 KB |
Connector type |
· RJ-45 · LC · USB (Type A) |
· RJ-45 · LC · USB (Type A) |
Ports |
· 1 × console port · 1 × USB port (USB2.0, host port) · 2 × management Ethernet ports, including one RJ-45 management Ethernet port and one SFP management Ethernet port |
· 1 × console port · 1 × USB port (USB2.0, host port) · 2 × management Ethernet ports, including one RJ-45 management Ethernet port and one SFP management Ethernet port |
Transmission rate |
· Console port: 9600 bps (default) to 115200 bps · RJ-45 management Ethernet port: 10/100/1000 Mbps, half/full duplex · SFP management Ethernet port: 1000 Mbps |
· Console port: 9600 bps (default) to 115200 bps · RJ-45 management Ethernet port: 10/100/1000 Mbps, half/full duplex · SFP management Ethernet port: 1000 Mbps |
Table2-4 Type-S MPU specifications
Item |
LSXM1SUPS2 |
LSXM3SUPS2 |
LSXM3SUP04S2 |
Processor |
Single core, 1 GHz |
Quad core, 2.6 GHz |
Quad core, 2.6 GHz |
SDRAM |
2 GB |
8 GB |
4 GB |
Flash |
1 GB |
2 GB |
2 GB |
NVRAM |
1 MB |
1 MB |
1 MB |
Connector type |
· RJ-45 · LC · USB (Type A) |
· RJ-45 · LC · USB (Type A) |
· RJ-45 · LC · USB (Type A) |
Ports |
· 1 × console port · 1 × USB console port · 2 × management Ethernet ports, including one RJ-45 management Ethernet port and one SFP management Ethernet port · 1 × USB port |
· 1 × console port · 1 × USB console port · 2 × management Ethernet ports, including one RJ-45 management Ethernet port and one SFP management Ethernet port · 1 × USB port |
· 1 × console port · 1 × USB console port · 2 × management Ethernet ports, including one RJ-45 management Ethernet port and one SFP management Ethernet port · 1 × USB port |
Transmission rate |
· Console port: 9600 bps (default) to 115200 bps · USB console port: £ 115200 bps (default: 9600 bps) · RJ-45 management Ethernet port: 10/100/1000 Mbps, half/full duplex · SFP management Ethernet port: 1000 Mbps |
· Console port: 9600 bps (default) to 115200 bps · USB console port: £ 115200 bps (default: 9600 bps) · RJ-45 management Ethernet port: 10/100/1000 Mbps, half/full duplex · SFP management Ethernet port: 1000 Mbps |
· Console port: 9600 bps (default) to 115200 bps · USB console port: £ 115200 bps (default: 9600 bps) · RJ-45 management Ethernet port: 10/100/1000 Mbps, half/full duplex · SFP management Ethernet port: 1000 Mbps |
IMPORTANT: · To verify compatibility of the module with the software release you are using, see the release notes. · The USB port outputs power as prescribed by USB 2.0. You can only install a USB 2.0-compliant device in the USB port. · Set the same speed and duplex mode for a management Ethernet port and its peer port. · If the two management ports are connected to one remote switch, you must assign their peer ports to different VLANs. Login or file transfer will fail if the peer ports are in the same VLAN. · When using the BootWare menu to upgrade software or BootWare, make sure you use 10/100/1000BASE-T port M0/0/0 for image transferring. · Type-S modules include Type-S MPUs (for example, LSXM1SUPS2), Type-S fabric modules (for example, LSXM1SFS08D2), and Type-S service modules (for example, LSXM1TGS48SE2). A Type-S module can be used together only with another Type-S module. You cannot install a Type-S module and a module of another type on the same switch. · Type-T modules include Type-T MPUs (for example, LSXM2SUPT2), Type-T fabric modules (for example, LSXM2SFT08E2), and Type-T service modules (for example, LSXM1TGS48TE2). A Type-T module can be used together only with another Type-T module. You cannot install a Type-T module and a module of another type on the same switch. |
Service modules
Restrictions and guidelines
The data drives on the LSXM1SEERBXC2, LSXM1SEERBXD2, LSXM1SEERBG2, LSXM1SEERBA2, or LSXM1SEERBNPA2 module are not hot swappable.
The LSXM1SEERBXC2, LSXM1SEERBXD2, LSXM1SEERBG2, LSXM1SEERBA2, or LSXM1SEERBNPA2 module can be used together only with Type-T MPUs (for example, LSXM2SUPT2) and Type-T fabric modules (for example, LSXM2SFT08E2).
The LSXM1SEERBG2 and LSXM1SEERBA2 modules cannot be used with the LSXM1QGS36TE2 interface module.
Type-S modules include Type-S MPUs (for example, LSXM1SUPS2), Type-S fabric modules (for example, LSXM1SFS08D2), and Type-S service modules (for example, LSXM1TGS48SE2). A Type-S module can be used together only with another Type-S module. You cannot install a Type-S module and a module of another type on the same switch.
Type-T modules include Type-T MPUs (for example, LSXM2SUPT2), Type-T fabric modules (for example, LSXM2SFT08E2), and Type-T service modules (for example, LSXM1TGS48TE2). A Type-T module can be used together only with another Type-T module. You cannot install a Type-T module and a module of another type on the same switch.
SF interface modules cannot be used together with Type-S Class-D fabric modules.
As a best practice, use SE interface modules together with Type-S Class-D fabric modules. If you use the LSXM3GP48SE2 or LSXM3GT48SE2 interface module together with other Type-S fabric modules, contact Technical Support to ensure no interface modules on the switch will fail to start up.
Ethernet interface modules
Table2-5 Type-T Ethernet interface module specifications
Interface module |
Port quantity |
Port type |
Available transceiver modules and cables |
LSXM1CGQ36TE2 |
36 |
36 × 100GBASE-R QSFP28 fiber ports |
· QSFP28 transceiver modules · QSFP28 DAC cables · QSFP28 AOC cables · QSFP+ transceiver modules · QSFP+ DAC cables · QSFP+ AOC cables · QSFP28 to SFP28 DAC cables · QSFP+ to SFP+ DAC cables |
LSXM1CGQ18TE2 |
18 |
18 × 100GBASE-R QSFP28 fiber ports |
· QSFP28 transceiver modules · QSFP28 DAC cables · QSFP28 AOC cables · QSFP+ transceiver modules · QSFP+ DAC cables · QSFP+ AOC cables · QSFP28 to SFP28 DAC cables · QSFP+ to SFP+ DAC cables |
LSXM1CGQ18TD2 |
18 |
18 × 100GBASE-R QSFP28 fiber ports |
· QSFP28 transceiver modules · QSFP28 DAC cables · QSFP28 AOC cables · QSFP+ transceiver modules · QSFP+ DAC cables · QSFP+ AOC cables · QSFP28 to SFP28 DAC cables · QSFP+ to SFP+ DAC cables |
LSXM1CGQ8TD2 |
8 |
8 × 100GBASE-R QSFP28 fiber ports |
· QSFP28 transceiver modules · QSFP28 DAC cables · QSFP28 AOC cables · QSFP+ transceiver modules · QSFP+ DAC cables · QSFP+ AOC cables · QSFP28 to SFP28 DAC cables · QSFP+ to SFP+ DAC cables |
LSXM1QGS36TE2 |
36 |
36 × 40GBASE-R QSFP+ fiber ports |
· QSFP+ transceiver modules · QSFP+ DAC cables · QSFP+ AOC cables |
LSXM1QGS36TD2 |
36 |
36 × 40GBASE-R QSFP+ fiber ports |
· QSFP+ transceiver modules · QSFP+ DAC cables · QSFP+ AOC cables |
LSXM1TGS48TE2 |
48 |
48 × 10GBASE-R SFP+ fiber ports |
· 10-GE SFP+ transceiver modules · 10-GE SFP+ DAC cables · 1-GE SFP transceiver modules |
LSXM1TGS48TD2 |
48 |
48 × 10GBASE-R SFP+ fiber ports |
· 10-GE SFP+ transceiver modules · 10-GE SFP+ DAC cables · 1-GE SFP transceiver modules |
LSXM1TGS24XT24C4Q2TE2 |
54 |
· 4 × 100GBASE-R QSFP28 fiber ports · 2 × 40GBASE-R QSFP+ fiber ports · 24 × 10GBASE-R SFP+ fiber ports · 24 × 10G/1000BASE-T RJ-45 copper ports |
· QSFP28 transceiver modules · QSFP28 DAC cables · QSFP28 AOC cables · QSFP+ transceiver modules · QSFP+ DAC cables · QSFP+ AOC cables · 10-GE SFP+ transceiver modules · 10-GE SFP+ DAC cables · Category 6A/7 twisted pair cables |
LSXM1YGS24CGMODTE2 |
28 + ports on the interface card |
· 4 × 100GB QSFP28 fiber ports · 24 × 25GB SFP28 fiber ports · Ports on the interface card (see Table2-8) |
· QSFP28 transceiver modules · QSFP28 DAC cables · QSFP28 AOC cables · QSFP+ transceiver modules · QSFP+ DAC cables · QSFP+ AOC cables · SFP28 transceiver modules · SFP28 DAC cables · SFP28 AOC cables |
Table2-6 Type-S Ethernet interface module specifications
Interface module |
Port quantity |
Port type |
Available transceiver modules and cables |
LSXM3CDQ16SF2 |
16 |
16 × 400G QSFP-DD fiber ports |
· QSFP-DD transceiver modules · QSFP-DD DAC cables · QSFP28 transceiver modules · QSFP28 DAC cables · QSFP28 AOC cables · QSFP+ transceiver modules · QSFP+ DAC cables · QSFP+ AOC cables |
LSXM3CDQ8SF2 |
8 |
8 × 400G QSFP-DD fiber ports |
· QSFP-DD transceiver modules · QSFP-DD DAC cables · QSFP28 transceiver modules · QSFP28 DAC cables · QSFP28 AOC cables · QSFP+ transceiver modules · QSFP+ DAC cables · QSFP+ AOC cables |
LSXM3CGQ36SF2 |
36 |
36 × 100GBASE-R-QSFP28 fiber ports |
· QSFP28 transceiver modules · QSFP28 DAC cables · QSFP28 AOC cables · QSFP+ transceiver modules · QSFP+ DAC cables · QSFP+ AOC cables · QSFP28 to SFP28 DAC cables · QSFP+ to SFP+ DAC cables |
LSXM3CGQ18SF2 |
18 |
18 × 100GBASE-R-QSFP28 fiber ports |
· QSFP28 transceiver modules · QSFP28 DAC cables · QSFP28 AOC cables · QSFP+ transceiver modules · QSFP+ DAC cables · QSFP+ AOC cables · QSFP28 to SFP28 DAC cables · QSFP+ to SFP+ DAC cables |
LSXM3QGS36SF2 |
36 |
36 × 40GBASE-R-QSFP+ fiber ports |
· QSFP+ transceiver modules · QSFP+ DAC cables · QSFP+ AOC cables · QSFP+ to SFP+ DAC cables |
LSXM3YGS48SF2 |
48 |
48 × 25GBASE-R-SFP28 fiber ports |
· SFP28 transceiver modules · SFP28 DAC cables · SFP28 AOC cables · 10-GE SFP+ transceiver modules · 10-GE SFP+ DAC cables · GE SFP transceiver modules |
LSXM1TGS48SE2 |
48 |
48 × 10GBASE-R-SFP+ fiber ports |
· 10-GE SFP+ transceiver modules · 10-GE SFP+ DAC cables · GE SFP transceiver modules |
LSXM3TGS48SF2 |
48 |
48 × 10GBASE-R-SFP+ fiber ports |
· 10-GE SFP+ transceiver modules · 10-GE SFP+ DAC cables · GE SFP transceiver modules |
LSXM1GT24GPSE2 |
48 |
· 24 × 10/100/1000BASE-T-RJ45 copper ports · 24 × 1000BASE-X-SFP fiber ports |
· GE SFP transceiver modules · Category 5 or above twisted pair cables |
LSXM3GT24GPSE2 |
48 |
· 24 × 10/100/1000BASE-T-RJ45 copper ports · 24 × 1000BASE-X-SFP fiber ports |
· GE SFP transceiver modules · Category 5 or above twisted pair cables |
LSXM1GT48SE2 |
48 |
48 × 10/100/1000BASE-T-RJ45 copper ports |
Category 5 or above twisted pair cables |
LSXM3GT48SE2 |
48 |
48 × 10/100/1000BASE-T-RJ45 copper ports |
Category 5 or above twisted pair cables |
LSXM3GP48SE2 |
48 |
48 ×1000BASE-X-SFP fiber ports |
GE SFP transceiver modules |
Integrated service modules
Table2-7 Integrated service module specifications
Integrated service module |
Description |
Port type and quantity |
Available transceiver modules and cables |
LSXM1SEERBXC2 |
Campus SeerEngine module |
· 3 × 10GBASE-R-SFP+ fiber ports · 1 × 10GBASE-R-SFP+ HDM shared network port (used for Ethernet connection or HDM access) · 2 × 1TB data drive ports · 1 × SUV port (using an SUV connector) · 1 × USB 3.0 port · 1 × console port (used by technical support for debugging only) · 1 × 10/100/1000BASE-T HDM dedicated network port (default IP address: 192.168.1.2/24) NOTE: The HDM shared network port obtains IP addresses through DHCP automatically. |
· 10-GE SFP+ transceiver modules · Category 5 or above twisted pair cables |
LSXM1SEERBXD2 |
DC SeerEngine module |
· 3 × 10GBASE-R-SFP+ fiber ports · 1 × 10GBASE-R-SFP+ HDM shared network port (used for Ethernet connection or HDM access) · 2 × 1TB data drive ports · 1 × SUV port (using an SUV connector) · 1 × USB 3.0 port · 1 × console port (used by technical support for debugging only) · 1 × 10/100/1000BASE-T HDM dedicated network port (default IP address: 192.168.1.2/24) NOTE: The HDM shared network port obtains IP addresses through DHCP automatically. |
· 10-GE SFP+ transceiver modules · Category 5 or above twisted pair cables |
LSXM1SEERBA2 |
High performance compute engine module |
· 3 × 10GBASE-R-SFP+ fiber ports · 1 × 10GBASE-R-SFP+ HDM shared network port (used for Ethernet connection or HDM access) · 2 × 1TB data drive ports · 1 × SUV port (using an SUV connector) · 1 × USB 3.0 port · 2 × console ports (used by technical support for debugging only) · 1 × 10/100/1000BASE-T management Ethernet port (used by technical support for debugging only) · 1 × 10/100/1000BASE-T HDM dedicated network port (default IP address: 192.168.1.2/24) NOTE: The HDM shared network port obtains IP addresses through DHCP automatically. |
· 10-GE SFP+ transceiver modules · Category 5 or above twisted pair cables |
LSXM1SEERBG2 |
AI compute engine module |
· 1 × 10GBASE-R SFP+ fiber port · 1 × 10GBASE-R SFP+ HDM shared network port (used for Ethernet connection or HDM access) · 2 × 1TB data drive interfaces · 1 × SUV port (using an SUV connector) · 1 × USB 3.0 port · 2 × console ports (used by technical support for debugging only) · 1 × 10/100/1000BASE-T management Ethernet port (used by technical support for debugging only) · 1 × 10/100/1000BASE-T HDM dedicated network port (default IP address: 192.168.1.2/24) NOTE: The HDM shared network port obtains IP addresses through DHCP automatically. |
· 10-GE SFP+ transceiver modules · Category 5 or above twisted pair cables |
LSXM1SEERBNPA2 |
Network performance analytics module |
· 3 × 10GBASE-R-SFP+ fiber ports · 1 × 10GBASE-R-SFP+ HDM shared network port (used for Ethernet connection or HDM access) · 2 × 1TB data drive ports · 1 × SUV port (using an SUV connector) · 1 × USB 3.0 port · 1 × console port (used by technical support for debugging only) · 1 × 10/100/1000BASE-T HDM dedicated network port (default IP address: 192.168.1.2/24) NOTE: The HDM shared network port obtains IP addresses through DHCP automatically. |
· 10-GE SFP+ transceiver modules · Category 5 or above twisted pair cables |
Interface cards
CAUTION: Before hot swapping an interface card, make sure the switch is operating correctly. Do not install or remove an interface card during startup of the switch. |
Table2-8 Interface cards available for the LSXM1YGS24CGMODTE2 module
Interface card |
Description |
Port type and quantity |
LSWM18QC |
8-port QSFP+ interface card |
8 × QSFP+ ports |
LSWM124XG2Q |
24-port SFP+ and 2-port QSFP+ interface card with MACSec |
24 × SFP+ ports and 2 × QSFP+ ports |
LSWM124TG2H |
24-port 25G Ethernet optical interface (SFP28) and 2-port 100G Ethernet optical interface (QSFP28) module |
24 × SFP28 ports and 2 × QSFP28 ports |
LSWM124XGT2Q |
24-port 10GBASE-T and 2-port QSFP Plus Interface Card with MACSec |
24 × 10-GE copper ports and 2 × QSFP+ ports |
LSWM1FWD0 |
LSWM1FWD0 firewall module |
1 × console port, 1 × USB port, and 2 × management Ethernet ports, including one RJ-45 management Ethernet port and one SFP management Ethernet port |
Fabric modules
Type-S modules include Type-S MPUs (for example, LSXM1SUPS2), Type-S fabric modules (for example, LSXM1SFS08D2), and Type-S service modules (for example, LSXM1TGS48SE2). A Type-S module can be used together only with another Type-S module. You cannot install a Type-S module and a module of another type on the same switch.
Type-T modules include Type-T MPUs (for example, LSXM2SUPT2), Type-T fabric modules (for example, LSXM2SFT08E2), and Type-T service modules (for example, LSXM1TGS48TE2). A Type-T module can be used together only with another Type-T module. You cannot install a Type-T module and a module of another type on the same switch.
Install fabric modules from the lowest-numbered fabric module slot to the highest.
Do not install fabric modules of different models on the same switch.
SF interface modules cannot be used together with Type-S Class-D fabric modules.
As a best practice, use SE interface modules together with Type-S Class-D fabric modules. If you use the LSXM3GP48SE2 or LSXM3GT48SE2 interface module together with other Type-S fabric modules, contact Technical Support to ensure that no interface modules on the switch will fail to start up.
Table2-9 Type-T fabric module ordering guide
Switch model |
Available fabric modules |
Fabric module quantity per switch |
S12516G-AF |
LSXM1SFT16F2 |
2 to 6 |
LSXM1SFT16E1 |
2 to 6 |
|
S12508G-AF |
LSXM2SFT08E2 |
2 to 6 |
LSXM1SFT08F2 |
2 to 6 |
|
S12504G-AF |
LSXM1SFT04F2 |
2 to 6 |
Table2-10 Type-S fabric module ordering guide
Switch model |
Available fabric modules |
Fabric module quantity per switch |
S12516G-AF |
LSXM3SFS16F2 |
2 to 6 |
LSXM3SFS16G2 |
2 to 6 |
|
S12508G-AF |
LSXM1SFS08D2 |
2 to 6 |
LSXM3SFS08F2 |
2 to 6 |
|
LSXM3SFS08G2 |
2 to 6 |
|
S12504G-AF |
LSXM3SFS04G2 |
2 to 6 |
Fabric module slot filler panel
The switch comes with empty fabric module slots. For good ventilation, purchase and install filler panels in the empty fabric module slots.
Table2-11 Fabric module slot filler panel ordering guide
Item |
Quantity |
Fabric module slot filler panel for the S12516G-AF switch |
0 to 4 |
Fabric module slot filler panel for the S12508G-AF switch |
|
Fabric module slot filler panel for the S12504G-AF switch |
Slide rails
No slide rails are shipped with the switch. Select slide rails for the switch as required. Table2-12 describes the slide rails available for the switch.
Table2-12 Slide rails available for the switch
Switch model |
Max. chassis weight (fully configured) |
Applicable slide rails |
||
Slide rail model |
Adjustment range |
Occupied space |
||
S12516G-AF |
360 kg (793.65 lb) |
LSXM1BSR |
630 mm to 900 mm (24.80 in to 35.43 in) |
1 RU |
S12508G-AF |
200 kg (440.92 lb) |
LSXM1BSR |
630 mm to 900 mm (24.80 in to 35.43 in) |
1 RU |
LSTM2KSGD0 |
500 mm to 800 mm (19.69 in to 31.50 in) |
2 RU |
||
S12504G-AF |
115 kg (253.53 lb) |
LSVM1BSR10 |
630 mm to 850 mm (24.80 in to 33.46 in) |
N/A |
Power modules
CAUTION: You must install power modules of the same model for the switch. |
The switch supports N+N (dual power input sources) or N+1 (single power input source) power module redundancy. Determine the number of power modules based on the power supply mode and system power consumption. Make sure the maximum total output power of the installed power modules is greater than the system power consumption. Reserve a 20% power surplus as a best practice.
Table2-13 describes the power modules available for the switch.
Table2-13 Power modules available for the switch
Switch model |
Available power modules |
S12516G-AF S12508G-AF S12504G-AF |
PSR2400-54A PSR2400-54D PSR3000-54A PSR3000-54AHD |
Table2-14 PSR2400-54A power module specifications
Item |
Specifications |
|
Rated input voltage |
100 to 240 VAC @ 50 or 60 Hz |
|
Rated output voltage |
54 VDC |
|
Maximum input current |
16 A |
|
Maximum output current |
44.5 A |
|
Maximum output power |
· 1200 W @ 110 VAC · 2400 W @ 220 VAC |
|
Dimensions (H × W × D) |
41 × 100 × 332 mm (1.61 × 3.94 × 13.07 in) |
|
Ambient temperature |
Operating temperature |
–10°C to +50°C (–14°F to +122°F) |
Storage temperature |
–40°C to +70°C (–40°F to +158°F) |
Table2-15 PSR3000-54A power module specifications
Item |
Specifications |
|
Rated input voltage |
· 100 to 240 VAC @ 50 or 60 Hz · 240 VDC |
|
Rated output voltage |
54 VDC |
|
Maximum input current |
16 A |
|
Maximum output current |
55.6 A |
|
Maximum output power |
· 1200 W (110 VAC) · 2400 W (175 to 200 VAC) · 3000 W (220 VAC or 240 VDC) |
|
Dimensions (H × W × D) |
41 × 100 × 332 mm (1.61 × 3.94 × 13.07 in) |
|
Ambient temperature |
Operating temperature |
–10°C to +50°C (–14°F to +122°F) |
Storage temperature |
–40°C to +70°C (–40°F to +158°F) |
Table2-16 PSR2400-54D power module specifications
Item |
Specifications |
|
Rated input voltage |
–48 to –60 VDC |
|
Rated output voltage |
54 VDC |
|
Maximum input current |
80 A |
|
Maximum output current |
44.5 A |
|
Maximum output power |
2400 W |
|
Dimensions (H × W × D) |
41 × 100 × 332 mm (1.61 × 3.94 × 13.07 in) |
|
Ambient temperature |
Operating temperature |
–10°C to +50°C (–14°F to +122°F) |
Storage temperature |
–40°C to +70°C (–40°F to +158°F) |
Table2-17 PSR3000-54AHD power module specifications
Item |
Specifications |
|
Rate input voltage range |
· AC input: 100 to 240 VAC @ 50 or 60 Hz · High-voltage DC input: 240 to 380 VDC |
|
Rated output voltage |
54 VDC |
|
Maximum output current |
27.8 A (110 VAC) 55.6 A (220 VAC or 240 to 380 VDC) |
|
Maximum output power |
1500 W (110 VAC) 3000 W (220 VAC or 240 to 380 VDC) |
|
Dimensions (H × W × D) |
41 × 100 × 332 mm (1.61 × 3.94 × 13.07 in) |
|
Ambient temperature |
Operating temperature |
–10°C to +50°C (–14°F to +122°F) |
Storage temperature |
–40°C to +70°C (–40°F to +158°F) |
|
NOTE: The power module shuts down automatically when its temperature exceeds the acceptable range. When the temperature returns to the acceptable range, the power module automatically restarts. |
Fan trays
Table2-18 Fan tray specifications
Model |
Available fan trays |
Number of fans |
Fan diameter |
Maximum air flow rate |
S12516G-AF |
LSXM116XFANH (high-performance) |
6 |
134 mm (5.28 in) |
1860 CFM (52.67 m3/min) |
LSXM116XFAN |
6 |
120 mm (4.72 in) |
1020 CFM (28.88 m3/min) |
|
S12508G-AF |
LSXM108XFANH (high-performance) |
3 |
134 mm (5.28 in) |
930 CFM (26.33 m3/min) |
LSXM108XFAN |
3 |
120 mm (4.72 in) |
510 CFM (14.44 m3/min) |
|
S12504G-AF |
LSXM104XFANH (high-performance) |
2 |
120 mm (4.72 in) |
560 CFM (15.86 m3/min) |
LSXM104XFAN |
2 |
120 mm (4.72 in) |
340 CFM (9.63 m3/min) |
DC power cords
A DC power cord is used for connecting a DC power module on the switch to the external DC power supply system.
Table2-19 describes DC power cords available for the switch.
Table2-19 DC power cord specifications
Power module model |
Power cord length |
Description |
PSR2400-54D |
3 m (9.84 ft) |
Connects the DC power module to an external DC power supply system. |
15 m (49.21 ft) |
||
PSR3000-54AHD |
3 m (9.84 ft) |
Connects the 3000W AC & 240 to 380 HVDC power module to an external DC power supply system. |
AC power cords
An AC power cords is used for connecting an AC power module on the switch to the external AC power supply system.
· Select an AC power cord with a current-carrying capacity that meets the power module requirement.
· The connector type varies by country or region. Select a compliant connector type as needed.
· Select 16A AC power cords for the switch. For the connector types of different countries or regions, see Table2-20.
Table2-20 16A AC power cords used in different countries or regions
1 |
Connector type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||
I type |
04043396 (3 m/9.84 ft) |
Mainland China |
N/A |
N/A |
|||
Connector outline |
Power cord outline |