H3C EPON OLT Installation Manual(Release 5200 SeriesV1.02)

DownLoad Chapters Download(345 KB)

02-Chapter2 EPON LPUs


Chapter 2  EPON LPUs

2.1  LS81PT4GA-4-Port 1000Base-PX10 (EPON) Ethernet LPU

Figure 2-1 The appearance of an LS81PT4GA LPU

2.1.1  Introduction to LS81PT4GA LPU

An LS81PT4GA LPU provides four SC/PC EPON optical ports. The distance between an SC/PC EPON port on it and an ONU device can be up to 10 km (6.2 mi).

Table 2-1 LS81PT4GA LPU specifications

Item

LS81PT4GA

CPU

MPC8241

Boot ROM

512 KB

SDRAM

128 MB

Dimensions (L   W)

366.7   340 mm (14.4   13.4 in.)

Maximum power consumption

34 W

Port type

SC/PC

Number of ports

4

Port transmission speed

1000 Mbps

Conformed port standard

1000Base-PX10

Conformed standard

IEEE802.3ah

Matched SRPU

LS81T12PE, LS81P12TE, and Salience III series SRPUs

 

2.1.2  Panel and LEDs

Figure 2-2 The panel of an LS81PT4GA LPU

Table 2-2 describes the LED states.

Table 2-2 Description of LS81PT4GA LPU LED states

LED

State

LINK

OFF

No link is present.

ON

A link is present.

 

2.1.3  Matched Cable

Table 2-3 Matched cables for LS81PT4GA LPU

SFF module

Central wavelength

Connector

Matched cable

Maximum transmission distance

1000Base-PX-SFF-SC

Transmit: 1490 nm

Receive: 1310 nm

SC/PC

9/125  m single mode optical fiber

10 km (6.2 mi)

 

2.2  LS81PT8GA-8-Port 1000Base-PX10 (EPON) Ethernet LPU

Figure 2-3 The appearance of an LS81PT8GA LPU

2.2.1  Introduction to LS81PT8GA LPU

An LS81PT8GA LPU provides eight SC/PC EPON optical ports. The distance between an SC/PC EPON port on it and an ONU device can be up to 10 km (6.2 mi).

Table 2-4 LS81PT8GA LPU specifications

Item

LS81PT8GA

CPU

MPC8241

Boot ROM

512 KB

SDRAM

128 MB

Dimensions (L   W)

366.7   340 mm (14.4   13.4 in.)

Maximum power consumption

50 W

Connector

SC/PC

Number of ports

8

Port transmission speed

1000 Mbps

Conformed port standard

1000Base-PX10

Conformed standard

IEEE802.3ah

Matched SRPU

LS81T12PE, LS81P12TE, and Salience III series (excluding Salience III-Plus) SRPUs

 

l      An LS81PT8GA LPU can operate with the presence of an LS81T12PE, an LS81P12TE, a Salience III, or a Salience III Edge SRPUs only.

l      For S7500 series switches with Salience III or Salience III Edge SRPUs installed, an LS81PT8GA LPU cannot be installed in the sixth LPU slot of an S7506 or S7506R switch, but it can be installed in any LPU slot of an S7503 switch.

 

2.2.2  Panel and LEDs

Figure 2-4 The panel of an LS81PT8GA LPU

Table 2-5 describes the LED states.

Table 2-5 Description of LS81PT8GA LPU LED states

LED

State

LINK

OFF

No link is present.

ON

A link is present.

 

2.2.3  Matched Cable

Table 2-6 Matched cables for LS81PT8GA LPU

SFF module

Central wavelength

Connector

Cable

Maximum transmission distance

1000Base-PX-SFF-SC

Transmit: 1490 nm

Receive: 1310 nm

SC/PC

9/125  m single mode optical fiber

10 km (6.2 mi)

 

2.3  LS8M1PT4GB0-4-Port 1000Base-PX20 (EPON) LPU

Figure 2-5 The appearance of an LS8M1PT4GB0 LPU

2.3.1  Introduction to LS8M1PT4GB0 LPU

An LS8M1PT4GB0 LPU provides four SC/PC EPON optical ports. The distance between an SC/PC EPON port on it and an ONU device can be up to 20 km (12.4 miles).

Table 2-7 LS8M1PT4GB0 LPU specifications

Item

LS8M1PT4GB0

CPU

MPC8241

BootROM

512 KB

SDRAM

128 MB

Dimensions (L x W)

366.7   340 mm (14.4   13.4 in.)

Maximum power consumption

38 W

Connector

SC/PC

Number of ports

4

Port transmission speed

1000 Mbps

Conformed port standard

1000Base-PX20

Conformed standard

IEEE 802.3ah

Matched SRPU

LS81T12PE, LS81P12TE, and Salience III series SRPUs

 

2.3.2  Panel and LEDs

Figure 2-6 shows the panel of an LS8M1PT4GB0 LPU.

Figure 2-6 The front panel of an LS8M1PT4GB0 LPU

Table 2-8 describes the LED states.

Table 2-8 Description of LS8M1PT4GB0 LPU LED states

LED

State

LINK

OFF

No link is present.

ON

A link is present.

 

2.3.3  Matched Cable

Table 2-9 Matched cables for LS8M1PT4GB0 LPU

SFF module

Central wavelength

Connector

Cable

Maximum transmission distance

1000Base-PX-SFF-SC

Transmit: 1490 nm

Receive: 1310 nm

SC/PC

9/125  m single mode fiber

20 km (12.4 mi)

 

2.4  LS8M1PT8GB0-8-Port 1000Base-PX20 (EPON) LPU

Figure 2-7 The appearance of an LS8M1PT8GB0 LPU

2.4.1  Introduction to LS8M1PT8GB0 LPU

An LS8M1PT8GB0 LPU provides eight SC/PC EPON optical ports. The distance between an SC/PC EPON port on it and an ONU device can be up to 20 km (12.4 miles).

Table 2-10 LS8M1PT8GB0 LPU specifications

Item

LS8M1PT8GB0

CPU

MPC8241

BootROM

512 KB

SDRAM

128 MB

Dimensions (L x W)

366.7   340mm (14.4   13.4 in.)

Maximum power consumption

58 W

Connector

SC/PC

Number of interfaces

8

Interface transmission speed

1000 Mbps

Confirmed port standard

1000Base-PX20

Confirmed standard

IEEE 802.3ah

Matched SRPU

LS81T12PE, LS81P12TE, and Salience III series SRPUs excluding Salience III Plus

 

&  Note:

l      An LS8M1PT8GB0 LPU can operate with the presence of an LS81T12PE, an LS81P12TE, a Salience III, or a Salience III Edge SRPU only.

l       For S7500 series switches with Salience III or Salience III Edge SRPUs installed, an LS8M1PT8GB0 LPU cannot be installed in the sixth LPU slot of an S7506 or S7506R switch, but it can be installed in any LPU slot of an S7503 switch.

 

2.4.2  Panel and LEDs

Figure 2-8 shows the front panel of an LS8M1PT8GB0 LPU.

Figure 2-8 The front panel of an LS8M1PT8GB0 LPU

Table 2-11 describes the LS8M1PT8GB0 LPU LED states.

Table 2-11 LED state description of the LS8M1PT8GB0

LED

State

LINK

OFF

No link is present.

ON

A link is present.

 

2.4.3  Matched Cable

Table 2-12 Matched cable for LS8M1PT8GB0 LPU

SFF module

Central wavelength

Connector

Matching cable

Maximum transmission distance

1000Base-PX-SFF-SC

Transmit: 1490 nm

Receive: 1310 nm

SC/PC

9/125  m single mode fiber

20 km (12.4 mi)

 

H3C reserves the right to modify its collaterals without any prior notice. For the latest information of the collaterals, please consult H3C sales or call 400 hotline.