H3C ET704-B-L EPON ONU Quick Start-5PW100

DownLoad Chapters Download(1.77 MB)

Strategy Partner :

01-Text

Packing List of H3C ET704-B-L

SN

Item

QTY

Unit

1

ET704-B-L

1

PCS

2

Power Adapter

1

Set

3

Quick Start

1

PCS

4

Warranty card

1

PCS

5

Quality certificate

1

PCS

 



Chapter 1  Product Overview

1.1  Introduction

ET704-B-L newly released by Hangzhou H3C Technologies Co., Ltd. (hereinafter referred to as H3C) are Ethernet passive optical network (EPON) interoperability standard–compliant, reliable optical network units (ONUs).

ET704-B-L (Compliant with IEEE 802.3ah 1000Base-PX20) supports Four Ethernet interfaces and one PON interface.Together with optical line terminal (OLT) and an optical distribution network (ODN), It can construct an integrated EPON system to implement fiber-to-the-home (FTTH) access for various services (for example, data, IPTV etc).

1.2  Features

l           Compliant with IEEE 802.3ah EPON standard and IEEE 802.3ah 1000Base-PX20.

l           Supports connection with OLT that meet the connectivity standard, enabling remote management, maintenance and configuration through OLT.

l           Supports internal fiber management and PON interface concealment.

l           Supports remote managment for Aolynk Group Management Protocol(AGMP)-capable switches.

l           Supports remote configuration through telnet.

l           Supports online software upgrade.

l           Supports power failure notification.

1.3  Appearance

I. Solid view

Figure 1-1 Solid view

II. Top view

Figure 1-2 Top view

III. Rear view

Figure 1-3 Rear view

1.4  Description of LEDs

Table 1-1 Description of LEDs

LED

Status

Meaning

POWER

On

The ET704-B-L is powered on.

Off

The ET704-B-L is not powered on.

ALARM

On

A fault occurs to the ET704-B-L.

Off

The ET704-B-L operates normally.

PON

On

The ET704-B-L is registered.

Off

The ET704-B-L is not registered.

LINK/ACT

On

A link is present.

Flashing

Data is being transmitted or received.

Off

No link is present.

 

1.5  Technical Specifications

Table 1-2 Technical specifications

Item

ET704-B-L

Power consumption

<8W

Input voltage

12V DC

Physical dimensions (H×W×D)

44.5 × 215 × 150 mm (1.75 × 8.46 × 5.91 in.)

Distance between wall-mounting holes

90 mm (3.54 in.)

Weight

<1 kg (2.20 lb)

Installation method

Indoor installation (desk-mounting or wall-mounting)

Operating temperature

0°C to 45°C (32°F to 113°F)

Operating humidity (noncondensing)

10% to 90% relative humidity

Interface type

Uplink PON interface

SC/PC, single-fiber bidirectional

Downlink user interface

RJ-45

Interface standard

Uplink PON interface

1000Base-PX20-U

Downlink user interface

10/100Base-T

Optical specifications

Wavelength

Uplink wavelength 1310 nm, downlink wavelength 1490 nm

Saturated optical power of the receiver

–3 dBm

Receiver sensitivity

–26.5 dBm

Transmit optical power

+4 dBm to –1 dBm

 

1.6  Network Design

The OLT is deployed in the central equipment room. ET704-B-L is directly placed at home to provide connections for users through Ethernet interfaces. The OLT can be connected to multiple ET704-B-L through an optical splitter to provide point-to-multipoint connections.

Figure 1-4 Network diagram for FTTH

 


Chapter 2  Hardware Installation

2.1  Precautions for Installation

To avoid device damage or bodily injury, observe the following precautions:

l           Before installation, check that all components in the ET704-B-L package are intact and read related instructions carefully.

l           Make sure the EPON service is enabled.

l           Install the ET704-B-L in a dry, well-ventilated place.

l           In the case of desk-mounting, make sure the desk is sturdy and well grounded. In the case of wall-mounting, fix the ET704-B-L and the power adapter to prevent a falloff.

l           Always use the power adapter shipped with the ET704-B-L to connect the ET704-B-L.

l           Keep the ET704-B-L far away from high power radio stations, radar, and high-frequency devices working in high currents. If necessary, adopt electromagnetic shielding.

l           Make sure sufficient space is reserved around the intake and exhaust vents on the ET704-B-L chassis for heat dissipation.

l           Do not open the cover of the ET704-B-L when it is operating. If necessary, do that under the guidance of professional maintenance personnel after disconnecting the power supply to the ET704-B-L.

l           Unplug the power plug before cleaning the ET704-B-L. Do not clean the ET704-B-L with a wet cloth or any liquid.

2.2  Installation Procedure

2.2.1  Connecting a Fiber

 

&  Note:

You need to ask professional personnel to route optical fiber in the ET704-B-L.

 

Follow these steps to connect a fiber:

1)         Remove the five screws from the back cover of the ET704-B-L and keep them in a safe place and take off the back cover (see Figure 2-1 and Figure 2-2).

Figure 2-1 Remove the screws from the back cover of the ET704-B-L

Figure 2-2 Internal structure of the ET704-B-L

2)         Remove the two screws that are used for fastening the fiber cable clip, put the operator’s fiber cable through the fiber cable entry, and retighten the screws (see Figure 2-3 and Figure 2-4).

 

&  Note:

Both sides of the fiber cable clip can be used. You can determine which side to use according to the thickness of the fiber cable.

 

Figure 2-3 Remove the screws that fasten the fiber cable clip

Figure 2-4 Put the fiber cable through the fiber entry

3)         Peel off the outer layer of the fiber cable, draw out a fiber, route it around the fiber management tray to a fiber splicing point, and peel off the outer layer of the optical fiber (see Figure 2-5).

 

&  Note:

There are two fiber splicing points in the ET704-B-L. You can select one (for example, the right one) according to the actual condition.

 

Figure 2-5 Route the optical fiber in the ET704-B-L

4)         Peel off the outer layer at the end of the tail fiber, draw out the core and splice the two fiber core in the tube shipped with the ET704-B-L, and fix them in the groove of the fiber splicing point; route the tail fiber around the fiber management tray to the tail fiber interface (see Figure 2-6).

 

  Caution:

l      Determine in advance that the tail fiber is long enough to reach the fiber splicing point.

l      Make sure that the tail fiber connector is well inserted into the tail fiber interface.

 

Figure 2-6 Splice the two fiber core and route the tail fiber

5)         Put the back cover on the ET704-B-L and fix it with the previously removed five screws.

2.2.2  Mounting the ET704-B-L on a Wall

You can install the ET704-B-L on a vertical wall by using flathead screws and the wall-mounting holes on the bottom of the chassis.

 

  Caution:

l      Make sure that the pan-head screws are secure and reliable.

l      The installation height of the ET704-B-L is subject to where you can conveniently observe the LEDs.

l      Be sure to fix the power adapter. Do not directly hang it on the ET704-B-L in case that it falls off the ET704-B-L.

 

I. Anchor and screw

Figure 2-7 and Figure 2-8 show the recommended screw sizes and anchor sizes (in mm) for installation, respectively.

Figure 2-7 Recommended screw sizes

(1): Anchor edge

Figure 2-8 Recommended anchor sizes

II. Installation procedure

Follow these steps to mount the ET704-B-L on a wall:

 

&  Note:

l      The ET704-B-L can be mounted on a wall by drilling two horizontal or vertical holes. The following describes how to mount the ET704-B-L on a wall by drilling two horizontal holes.

l      The diameter and depth of the two holes depend on the sizes of the anchor and screws. The anchor edges should be flush with the wall surface after the anchors are put into the holes, and the screws can be fastened on the wall after they are screwed into the anchors.

l      For the distance between the two holes, refer to Technical Specifications.

 

1)         As shown in Figure 2-9, drill two holes with a diameter of 5 mm and a distance of 90 mm and keep the line between the two holes horizontal.

2)         Put the anchors into the holes, with the edges flush with the wall surface.

3)         As shown in Figure 2-9, tighten the screws into the anchors, with a distance of no less than 2.5 mm between the bottom of the screw head and the anchor edge to hang the ET704-B-L firmly on the screws.

Figure 2-9 Drill holes and install anchors and screws

4)         Align the two holes on the bottom of the ET704-B-L chassis with the screws and hang the ET704-B-L on the screws.

2.2.3  Mounting the ET704-B-L on a Desk

Place the ET704-B-L on a clean, flat desk. When mounting the ET704-B-L on a desk, make sure that:

l           The desk is steady.

l           A clearance of 10 cm (3.94 in) around the ET704-B-L is reserved for heat dissipation.

2.3  Connecting the Power Adapter

 

  Caution:

The input voltage range of the power adapter is 100V AC to 240V AC.

 

Figure 2-10 Connect the power adapter

1)         Connect the output end of the supplied power adapter to the power interface on the ET704-B-L.

2)         Plug one end of the power cable into the input end of the power adapter.

3)         Plug the other end of the power cable into the power outlet.

 

&  Note:

After connecting the power adapter, check whether the power LED is on. If the power LED is off, check the connection of the power adapter.

 

2.4  Connecting an Ethernet Cable

Figure 2-11 Connect an Ethernet cable

1)         Connect one end of an Ethernet cable to one of the 10/100BASE-T interfaces on the ET704-B-L.

2)         Connect the other end to the RJ-45 interface on the peer device.

 


Chapter 3  Troubleshooting

The chapter only describes some simple ET704-B-L troubleshooting methods. If you cannot remove any fault using these methods, contact the local dealer in time.

Table 3-1 Troubleshoot the ET704-B-L through the LEDs

Status of LEDs

Possible fault

Troubleshooting method

The power LED is off.

The power adapter and the power cord are connected incorrectly.

Check that the power adapter and the power cord are correctly connected.

The power switch on the ET704-B-L is not turned on.

Turn on the power switch on the ET704-B-L.

An Ethernet interface LED is off in the case that the Ethernet interface is enabled.

The Ethernet cable is connected incorrectly.

l      Check that the Ethernet cable is correctly connected to the corresponding Ethernet interface on the ET704-B-L.

l      Check that the Ethernet cable is intact.

The PON LED is off.

The ET704-B-L registration fails.

Contact the local dealer.

The alarm LED is on.

A fault occurs to the ET704-B-L.

Contact the local dealer.

 

01-Text

Coperation Event & Solution

  • 01-Text.pdf