19-High Availability

HomeSupportRoutersCR16000-M SeriesReference GuidesMIB CompanionH3C CR16000-M Routers MIB Reference-R838x-6W10019-High Availability
06-HH3C-RDDC-MIB
Title Size Download
06-HH3C-RDDC-MIB 87.73 KB

HH3C-RDDC-MIB

About this MIB

This MIB is defined to obtain redundancy group configuration information and send notifications upon redundancy group state changes.

MIB file name

hh3c-rddc.mib

Root object

iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).hh3c(25506).hh3cCommon(2).hh3cRddc(151)

Scalar objects

hh3cRddcNodeInfo(1.3.6.1.4.1.25506.2.151.1.2.1)

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cRddcNodeInfo(1.3.6.1.4.1.25506.2.151.1.2.1)

accessible-for-notify

DisplayString

(0..255)

Node information in the notification.

As per the MIB.

 

hh3cRddcSwitchReason

(1.3.6.1.4.1.25506.2.151.1.2.2)

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cRddcSwitchReason

(1.3.6.1.4.1.25506.2.151.1.2.2)

accessible-for-notify

DisplayString

(0..255)

Switchover reason in the notification.

As per the MIB.

 

Tabular objects

hh3cRddcTable

About this table

This table contains redundancy group information.

Support for operations

CreateNot supported

Edit/ModifyNot supported

DeleteNot supported

ReadSupported

Columns

The table index is hh3cRddcGroupIdx.

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cRddcGroupIdx (1.3.6.1.4.1.25506.2.151.1.1.1.1.1)

accessible-for-notify

Unsigned32

Standard MIB values.

Redundancy group ID.

As per the MIB.

hh3cRddcGroupName (1.3.6.1.4.1.25506.2.151.1.1.1.1.2)

read-only

DisplayString

SIZE (1..16)

Redundancy group name.

As per the MIB.

hh3cRddcPreempTimeRemain

(1.3.6.1.4.1.25506.2.151.1.1.1.1.3)

read-only

Unsigned32

Standard MIB values.

Remaining preemption delay time of the redundancy group.

As per the MIB.

hh3cRddcPreempTimeConfig

(1.3.6.1.4.1.25506.2.151.1.1.1.1.4)

read-only

Unsigned32

Standard MIB values.

Configured preemption delay timer of the redundancy group.

As per the MIB.

hh3cRddcHoldTimeRemain

(1.3.6.1.4.1.25506.2.151.1.1.1.1.5)

read-only

Unsigned32

Standard MIB values.

Remaining hold-down time of the redundancy group.

As per the MIB.

hh3cRddcHoldTimeConfig

(1.3.6.1.4.1.25506.2.151.1.1.1.1.6)

read-only

Unsigned32

Standard MIB values.

Configured hold-down timer of the redundancy group.

As per the MIB.

 

hh3cRddcNodeTable

About this table

This table contains configuration and state information about a redundancy group.

Support for operations

CreateNot supported

Edit/ModifyNot supported

DeleteNot supported

ReadSupported

Columns

The table indexes are hh3cRddcNodeGroupIdx and hh3cRddcNodeId.

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cRddcNodeGroupIdx (1.3.6.1.4.1.25506.2.151.1.1.2.1.1)

not-accessible

Unsigned32

Standard MIB values.

Redundancy group ID.

As per the MIB.

hh3cRddcNodeId (1.3.6.1.4.1.25506.2.151.1.1.2.1.2)

not-accessible

Unsigned32

Standard MIB values.

Redundancy group node ID.

As per the MIB.

hh3cRddcNodeBindType

(1.3.6.1.4.1.25506.2.151.1.1.2.1.3)

read-only

INTEGER

Standard MIB values.

Binding type of the redundancy group, invalid(1) or chassis(2).

As per the MIB.

hh3cRddcNodeBindInfo (1.3.6.1.4.1.25506.2.151.1.1.2.1.4)

read-only

Unsigned32

Standard MIB values.

Binding information of the redundancy group node. Only chassis binding is supported.

As per the MIB.

hh3cRddcNodePriority (1.3.6.1.4.1.25506.2.151.1.1.2.1.5)

read-only

Unsigned32

1..255

Priority of the redundancy group node.

As per the MIB.

hh3cRddcNodeWeight (1.3.6.1.4.1.25506.2.151.1.1.2.1.6)

read-only

Integer32

Standard MIB values.

Weight of the redundancy group node. The default and maximum weight values are both 255.

As per the MIB.

hh3cRddcNodeStatus (1.3.6.1.4.1.25506.2.151.1.1.2.1.7)

read-only

INTEGER

Standard MIB values.

State of the redundancy group node. Supported values are invalid(1), master(2), and standby(3).

As per the MIB.

 

Notifications

hh3cRddcSwitchoverTrap

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.151.0.1

This notification is generated when a switchover occurs in the redundancy group.

Informational

Minor

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a switchover occurs in the redundancy group.

System impact

No impact on services. Services automatically migrate between the redundancy group nodes.

Status control

ON

CLI: Use the snmp-agent trap enable rddc command.

OFF

CLI: Use the undo snmp-agent trap enable rddc command.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.151.1.1.1.1.1 (hh3cRddcGroupIdx)

Redundancy group index.

hh3cRddcGroupIdx

Unsigned32

0..255

1.3.6.1.4.1.25506.2.151.1.1.1.1.2 (hh3cRddcGroupName)

Redundancy group name.

hh3cRddcGroupIdx

DisplayString

OCTET STRING (SIZE (1..16))

1.3.6.1.4.1.25506.2.151.1.2.1 (hh3cRddcNodeInfo)

Redundancy group node information.

N/A

DisplayString

OCTET STRING(SIZE (0..255)), "No chassis is active", "Chassis-chassis id is active"

1.3.6.1.4.1.25506.2.151.1.2.2 (hh3cRddcSwitchReason)

Switchover reason.

N/A

DisplayString

OCTET STRING(SIZE (0..255)), "manual switchover",, "group's configuration changed",, "node's weight changed"

 

Recommended action

To resolve this issue:

1.Execute the display redundancy group command to identify the cause of the switchover.

2.Resolve the cause and verify that the redundancy group nodes operate correctly.

hh3cRddcFailIfRecoverTrap

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.151.0.2

This notification is generated when the failed interface in the redundancy group recovers.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the failed interface in the redundancy group recovers

System impact

Services are resumed on the recovered interface.

Status control

ON

CLI: Use the snmp-agent trap enable rddc command.

OFF

CLI: Use the undo snmp-agent trap enable rddc command.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.151.1.1.1.1.1 (hh3cRddcGroupIdx)

Redundancy group index.

hh3cRddcGroupIdx

Unsigned32

0..255

1.3.6.1.4.1.25506.2.151.1.1.1.1.2 (hh3cRddcGroupName)

Redundancy group name.

hh3cRddcGroupIdx

DisplayString

OCTET STRING(SIZE (1..16))

1.3.6.1.2.1.2.2.1.1 (ifIndex)

Index of the failed interface.

ifIndex

InterfaceIndex

Integer32 (1..2147483647)

1.3.6.1.2.1.2.2.1.2 (ifDescr)

Description of the failed interface.