- Table of Contents
- Related Documents
-
Title | Size | Download |
---|---|---|
02-Hardware Information and Specifications | 798.43 KB |
1 Product models and technical specifications
Product models
H3C S6550XE-HI Ethernet switch series has one model: S6550XE-56HF-HI.
H3C S6550X-HI Ethernet switch series has one model: S6550X-32Q-HI.
Technical specifications
Table1-1 Technical specifications
Item |
S6550XE-56HF-HI |
S6550X-32Q-HI |
Dimensions (H × W × D) |
43.6 × 440 × 460 mm (1.72 × 17.32 × 18.11 in) |
43.6 × 440 × 400 mm (1.72 × 17.32 × 15.75 in) |
Weight |
≤ 15 kg (33.07 lb) |
≤ 8.5 kg (18.74 lb) |
Console port |
· 1 × mini USB console port · 1 × serial console port Only the mini USB console port is active when you connect both ports. |
1 × serial console port |
Management Ethernet port |
· 1 × 10M/100M/1000MBASE-T copper port · 1 × SFP fiber port |
1 |
USB port |
1 |
1 |
SFP port |
1 |
N/A |
QSFP+ port |
N/A |
28 |
SFP28 port |
48 |
N/A |
QSFP28 port |
8 |
4 |
Fan tray slot |
5 |
4 |
Power supply slot |
2 |
2 |
Expansion slot |
N/A |
1 |
SSD slot |
N/A |
1 |
Minimum power consumption |
· Single AC input: 167 W · Dual AC inputs: 179 W · Single DC input: 154 W · Dual DC inputs: 174 W |
· Single AC input: 83 W · Dual AC inputs: 95 W |
Maximum power consumption |
· Single AC input: 405 W · Dual AC inputs: 413 W · Single DC input: 400 W · Dual DC inputs: 408 W |
· Single AC input: 342 W · Dual AC inputs: 358 W |
Chassis leakage current compliance |
· UL60950-1 · EN60950-1 · IEC60950-1 · GB4943 |
· UL62368-1 · EN62368-1 · IEC62368-1 · UL60950-1 · EN60950-1 · IEC60950-1 · GB4943.1 |
Operating temperature |
–5°C to +45°C (23°F to 113°F) |
–5°C to +45°C (23°F to 113°F) |
Operating humidity |
5% RH to 95% RH, noncondensing |
5% RH to 95% RH, noncondensing |
Fire resistance compliance |
· UL60950-1 · EN60950-1 · IEC60950-1 · GB4943 |
· UL62368-1 · EN62368-1 · IEC62368-1 · UL60950-1 · EN60950-1 · GB4943.1 |
2 Chassis views
S6550XE-56HF-HI
Figure2-1 Front panel
(1) SFP28 port |
(2) SFP28 port LED |
(3) QSFP28 port |
(4) QSFP28 port LED |
(1) Copper management Ethernet port LED (LINK) |
(2) Mini USB console port |
(3) Serial console port |
(4) Fiber management Ethernet port |
(5) USB port |
(6) SFP port |
(7) Fan tray |
(8) Power supply |
(9) SFP port LED |
|
(10) Fiber management Ethernet port LED (LINK/ACT) |
|
(11) Copper management Ethernet port LED (ACT) |
(12) System status LED (SYS) |
(13) Copper management Ethernet port |
The S6550XE-56HF-HI switch comes with power supply slot PWR1 empty and power supply slot PWR2 installed with a filler panel. You can install one or two power supplies for the switch as needed. In Figure2-2, two LSVM1AC650 power supplies are installed in the power supply slots.
The S6550XE-56HF-HI switch comes with the five fan tray slots empty. You must install five fan trays of the same model for the switch. In Figure2-2, five LSWM1FANSA fan trays are installed in the fan tray slots.
Figure2-3 Left panel
(1) Power supply handle |
(2) Primary grounding point |
(3) Auxiliary grounding point |
(4) Fan tray handle |
S6550X-32Q-HI
Figure2-4 Front panel
(1) QSFP+ port |
(2) QSFP+ port LED |
(3) QSFP28 port |
(4) QSFP28 port LED |
(5) System status LED (SYS) |
(6) Expansion card status LED (SLOT) |
(1) Copper management Ethernet port LED (ACT) |
(2) Copper management Ethernet port LED (LINK) |
|
(3) Reset button (RESET) |
(4) Serial console port |
|
(5) Expansion card |
(6) Fan tray 1 (FAN1) |
|
(7) Fan tray 2 (FAN2) |
(8) Fan tray 3 (FAN3) |
|
(9) Fan tray 4 (FAN4) |
(10) Power supply 1 (PWR1) |
|
(11) Power supply 2 (PWR2) |
(12) USB port |
|
(13) SSD card |
(14) Copper management Ethernet port |
|
(15) Grounding screw |
||
The S6550X-32Q-HI switch comes with power supply slot PWR1 empty and power supply slot PWR2 installed with a filler panel. You can install one or two power supplies for the switch as needed. In Figure2-5, two PSR450-12A power supplies are installed in the power supply slots.
The S6550X-32Q-HI switch comes with the four fan tray slots empty. You must install four fan trays of the same model for the switch. In Figure2-5, four FAN-40F-1-A fan trays are installed in the fan tray slots.
The S6550X-32Q-HI switch comes with a filler panel in the expansion slot. You can select an expansion card for the switch as required. In Figure2-5, a filler panel is installed in the expansion slot.
The S6550X-32Q-HI switch provides a reset button at its rear panel. You can press the button to reboot the switch.
The S6550X-32Q-HI switch provides an SSD slot at its rear panel. You can install an SSD card to expand the device capacity.
3 Removable components and compatibility matrixes
The S6550XE-HI switch series and S6550X-HI switch series use removable components. Available removable components depend on the switch model.
Table3-1 Compatibility matrix between switches and removable components
FRUs |
FRU model |
S6550XE-56HF-HI |
S6550X-32Q-HI |
Power supplies |
LSVM1AC650 |
Supported |
Not supported |
LSVM1DC650 |
Supported |
Not supported |
|
PSR450-12A |
Not supported |
Supported |
|
Fay trays |
LSWM1FANSA |
Supported |
Not supported |
LSWM1FANSAB |
Supported |
Not supported |
|
FAN-40F-1-A |
Not supported |
Supported |
|
Expansion card |
LSPM6FWD |
Not supported |
Supported |
Power supplies
CAUTION: When the switch has power supplies in 1+1 redundancy, you can replace a power supply without powering off the switch. Before replacing a power supply, make sure it is powered off. |
You can install one power supply, or two power supplies in 1+1 redundancy for the switch.
Table3-2 Power supply specifications
Power supply model |
Specifications |
Remarks |
LSVM1AC650 |
· Rated input voltage: 100 VAC to 240 VAC @ 50 Hz or 60 Hz · Max input voltage: 90 VAC to 264 VAC @ 47 Hz to 63 Hz · Max output power: 650 W · Melting current of power supply fuse: 10 A, 250 V |
For more information about the power supplies, see H3C LSVM1AC650 & LSVM1DC650 Power Modules User Manual. |
LSVM1DC650 |
· Rated input voltage: –48 VDC to –60 VDC · Max input voltage: –40 VDC to –72 VDC · Max output power: 650 W · Melting current of power supply fuse: 30 A, 250 V |
|
PSR450-12A |
· AC input: ¡ Rated input voltage: 100 VAC to 240 VAC @ 50/60 Hz ¡ Max input voltage: 90 VAC to 290 VAC @ 47 Hz to 63 Hz ¡ Max output power: 450 W · HVDC input: ¡ Rated input voltage: 240 VDC ¡ Max input voltage: 180 VDC to 320 VDC ¡ Max output power: 450 W |
For more information about the power supplies, see H3C PSR450 Power Module Series User Manual |
Fan trays
CAUTION: For adequate heat dissipation, you must install fan trays of the same module for the switch. |
Table3-3 Fan tray specifications
Fan tray model |
Item |
Specifications |
· LSWM1FANSA (from the power supply side to the port side) · LSWM1FANSAB (from the port side to the power supply side) |
Dimensions |
40.6 × 42.5 × 118.7 mm (1.60 × 1.67 × 4.67 in) |
Fan speed |
21000 R.P.M |
|
Max airflow |
35 CFM |
|
Input voltage |
12 V |
|
Maximum power consumption |
30 W |
|
Documentation reference |
H3C LSWM1FANSA & LSWM1FANSAB Fan Tray User Guide |
|
FAN-40F-1-A (from the power supply side to the port side) |
Dimensions |
40 × 40.6 × 117 mm (1.57 × 1.60 × 4.61 in) |
Fan speed |
21000 R.P.M |
|
Max airflow |
26 CFM |
|
Input voltage |
12 V |
|
Maximum power consumption |
27.72 W |
|
Documentation reference |
H3C FAN-40F-1-A & FAN-40B-1-A Fan Trays User Guide |
Expansion modules
The S6550X-32Q-HI switch supports the LSPM6FWD module.
The LSPM6FWD is a high-performance fourth-generation firewall module. It provides features including firewall, VPN, content filtering, content identification, URL filtering, and NAT. By using this module on a switch, you can enhance the switch security capabilities without changing the network topology.
For more information about the module, see H3C LSPM6FWD Card Manual.
4 Ports and LEDs
As a best practice, use H3C transceiver modules and cables for the switch. H3C transceiver modules and cables are subject to change over time. For the most up-to-date list of H3C transceiver modules and cables, contact H3C Support or marketing staff. For information about the specifications and views of H3C transceiver modules and cables, see H3C Transceiver Modules User Guide.
Ports
Console ports
The S6550XE-56HF-HI switch has two console ports: one serial console port and one mini USB console port.
The S6550X-32Q-HI switch has one serial console port.
Table4-1 Console port specifications
Item |
Console port |
Mini USB console port |
Connector type |
RJ-45 |
USB mini-Type B |
Compliant standard |
EIA/TIA-232 |
USB 2.0 |
Transmission baud rate |
9600 bps (default) to 115200 bps |
|
Services |
· Provides connection to an ASCII terminal. · Provides connection to a serial port of a local terminal (for example a PC) running a terminal emulation program. |
· Provides connection to an ASCII terminal. · Provides connection to the USB port of a local terminal (for example a PC) running a terminal emulation program. |
Management Ethernet ports
The S6550XE-56HF-HI switch has two management Ethernet ports: one copper management port and one SFP management port. The S6550X-32Q-HI switch has one management Ethernet port. You can connect the ports to a local PC for software loading and debugging or to a remote management station for remote management.
Table4-2 Management Ethernet port specifications
Item |
S6550XE-56HF-HI |
S6550X-32Q-HI |
Connector type |
· 10/100/1000BASE-T management port: RJ-45. · SFP management port: LC. |
RJ-45. |
Port transmission rate |
· 10/100/1000BASE-T management port: ¡ 10/100 Mbps, half/full duplex, MDI/MDI-X auto-sensing. ¡ 1000 Mbps, full duplex, MDI/MDI-X auto-sensing. · SFP management port: 1000/100 Mbps, full duplex. |
1 × 10/100/1000BASE-T management port: · 10/100 Mbps, half/full duplex, MDI/MDI-X auto-sensing. · 1000 Mbps, full duplex, MDI/MDI-X auto-sensing. |
Transmission medium and max transmission distance |
· 10/100/1000BASE-T management port: 100 m (328.08 ft) over a category-5 UTP cable. · SFP management port: See FE transceiver modules described in Table4-4 and GE transceiver modules described in Table4-3. |
100 m (328.08 ft) over a category-5 UTP cable. |
Functions and services |
Software upgrade and network management. |
Software upgrade and network management. |
USB ports
The S6550XE-56HF-HI and S6550X-32Q-HI switches each have one OHCI-compliant USB 2.0 port that can upload and download data at a rate up to 480 Mbps. You can use this USB port to access the file system on the Flash of the switch, for example, to upload or download application and configuration files.
The USB port supplies power as per USB 2.0 specifications. Use only USB 2.0-compliant USB devices for the USB port. The port might not identity USB devices that are not compliant with USB 2.0.
|
NOTE: USB devices from different vendors vary in compatibilities and drivers. H3C does not guarantee correct operation of USB devices from other vendors on the switch. If a USB device fails to operate on the switch, replace it with one from another vendor. |
SFP port
The S6550XE-56HF-HI switch provides one SFP port on the rear panel. Table4-3 describes the GE SFP transceiver modules and cables and Table4-4 describes the FE SFP transceiver modules supported by the SFP port..
Table4-3 GE SFP transceiver modules and cables available for the SFP ports
GE SFP transceiver module |
Central wavelength (nm) |
Connector |
Cable/Fiber type and diameter (µm) |
Modal bandwidth (MHz × km) |
Max transmission distance |
SFP-GE-T |
N/A |
RJ-45 |
Twisted pair cable |
N/A |
100 m (328.08 ft) |
SFP-GE-T-D |
N/A |
RJ-45 |
Twisted pair cable |
N/A |
100 m (328.08 ft) |
SFP-GE-SX-MM850-A |
850 |
LC |
Multimode, 50/125 |
500 |
550 m (1804.46 ft) |
400 |
500 m (1640.42 ft) |
||||
Multimode, 62.5/125 |
200 |
275 m (902.23 ft) |
|||
160 |
200 m (656.17 ft) |
||||
SFP-GE-SX-MM850-D |
850 |
LC |
Multimode, 50/125 |
500 |
550 m (1804.46 ft) |
400 |
500 m (1640.42 ft) |
||||
Multimode, 62.5/125 |
200 |
275 m (902.23 ft) |
|||
160 |
200 m (656.17 ft) |
||||
SFP-GE-LX-SM1310-A |
1310 |
LC |
Single mode, 9/125 |
N/A |
10 km (6.21 miles) |
Multimode, 50/125 |
500 or 400 |
550 m (1804.46 ft) |
|||
Multimode, 62.5/125 |
500 |
550 m (1804.46 ft) |
|||
SFP-GE-LX-SM1310-D |
1310 |
LC |
Single mode, 9/125 |
N/A |
10 km (6.21 miles) |
SFP-GE-LH40-SM1310 |
1310 |
LC |
Single mode, 9/125 |
N/A |
40 km (24.86 miles) |
SFP-GE-LH40-SM1310-D |
1310 |
LC |
Single mode, 9/125 |
N/A |
40 km (24.86 miles) |
SFP-GE-LH40-SM1550 |
1550 |
LC |
Single mode, 9/125 |
N/A |
40 km (24.86 miles) |
SFP-GE-LH80-SM1550 |
1550 |
LC |
Single mode, 9/125 |
N/A |
80 km (49.71 miles) |
SFP-GE-LH80-SM1550-D |
1550 |
LC |
Single mode, 9/125 |
N/A |
80 km (49.71 miles) |
SFP-GE-LH100-SM1550 |
1550 |
LC |
Single mode, 9/125 |
N/A |
100 km (62.14 miles) |
SFP-GE-LX-SM1310-BIDI |
TX: 1310 RX: 1490 |
LC |
Single mode, 9/125 |
N/A |
10 km (6.21 miles) |
SFP-GE-LX-SM1490-BIDI |
TX: 1490 RX: 1310 |
LC |
Single mode, 9/125 |
N/A |
10 km (6.21 miles) |
SFP-GE-LH40-SM1310-BIDI |
TX: 1310 RX: 1550 |
LC |
Single mode, 9/125 |
N/A |
40 km (24.86 miles) |
SFP-GE-LH40-SM1550-BIDI |
TX: 1550 RX: 1310 |
LC |
Single mode, 9/125 |
N/A |
40 km (24.86 miles) |
SFP-GE-LH70-SM1490-BIDI |
TX: 1490 RX: 1550 |
LC |
Single mode, 9/125 |
N/A |
70 km (43.50 miles) |
SFP-GE-LH70-SM1550-BIDI |
TX: 1550 RX: 1490 |
LC |
Single mode, 9/125 |
N/A |
70 km (43.50 miles) |
SFP-STACK-Kit |
N/A |
N/A |
SFP cable |
N/A |
1.5 m (4.92 ft) |
IMPORTANT: · BIDI transceiver modules transmit and receive different central wavelengths for bidirectional transmission of optical signals on a single fiber. · BIDI transceiver modules must be used in matched pairs. For example, if one end uses an SFP-GE-LX-SM1310-BIDI transceiver module, the other end must use an SFP-GE-LX-SM1490-BIDI transceiver module. |
Table4-4 FE SFP transceiver modules available for the SFP ports
FE SFP transceiver module |
Central wavelength (nm) |
Connector |
Fiber type and diameter (µm) |
Max transmission distance |
SFP-FE-SX-MM1310-A |
1310 |
LC |
Multimode, 50/125 |
2 km (1.24 miles) |
Multimode, 62.5/125 |
||||
SFP-FE-LX-SM1310-A |
1310 |
LC |
Single mode, 9/125 |
15 km (9.32 miles) |
SFP-FE-LX-SM1310-D |
1310 |
LC |
Single mode, 9/125 |
15 km (9.32 miles) |
SFP-FE-LH40-SM1310 |
1310 |
LC |
Single mode, 9/125 |
40 km (24.86 miles) |
QSFP28 ports
The S6550XE-56HF-HI switch provides eight QSFP28 ports. The QSFP28 ports support the following transceiver modules and cables:
· QSFP28 transceiver modules in Table4-5.
· QSFP28 copper cables in Table4-6.
· QSFP28 fiber cables in Table4-7.
· QSFP28 to SFP28 copper cables in Table4-8.
· QSFP+ transceiver modules in Table4-9.
· QSFP+ copper cables in Table4-10.
· QSFP+ fiber cables in Table4-11.
· QSFP+ to SFP+ copper cables in Table4-12.
IMPORTANT: · You can use a QSFP-40G-SR4-MM850 or QSFP-40G-CSR4-MM850 transceiver module to connect a QSFP+ port to four SFP+ ports. The QSFP+ transceiver module and SFP+ transceiver modules to be connected must be the same in specifications, including central wavelength and fiber type. · QSFP28 ports are divided into two groups: ports 25 to 28 are in one group and ports 29 to 32 are in the other group. Only one port in each of the two groups can be split into four logical ports. · After splitting one port into four logical ports, you must save the configuration and reboot the device for the configuration to take effect. |
Table4-5 QSFP28 transceiver modules available for the QSFP28 ports
QSFP28 transceiver module or cable |
Central wavelength (nm) |
Connector |
Fiber type and diameter (µm) |
Modal bandwidth (MHz*km) |
Maximum transmission distance |
QSFP-100G-SR4-MM850 |
850 |
MPO (PC polished, 12-fiber) |
Multimode, 50/125 |
2000 |
70 m (229.66 ft) |
4700 |
100 m (328.08 ft) |
||||
QSFP-100G-PSM4-SM1310 |
1295 to 1325 |
MPO (APC polished, 12-fiber) |
Single mode, 9/125 |
N/A |
500 m (1640.42 ft) |
QSFP-100G-LR4-WDM1300 |
Four lanes: · 1295 · 1300 · 1304 · 1309 |
LC |
Single mode, 9/125 |
N/A |
10 km (6.21 miles) |
QSFP-100G-LR4L-WDM1300 |
Four lanes: · 1264.5 to 1277.5 · 1284.5 to 1297.5 · 1304.5 to 1317.5 · 1324.5 to 1337.5 |
LC |
Single mode, 9/125 |
N/A |
2 km (1.24 miles) |
QSFP-100G-eSR4-MM850 |
850 |
MPO (PC polished, 12-fiber) |
Multimode, 50/125 |
4700 |
300 m (984.25 ft) |
QSFP-100G-CWDM4-SM1300-A |
Four lanes: · 1271 · 1291 · 1311 · 1331 |
LC |
Single mode, 9/125 |
N/A |
2 km (1.24 miles) |
QSFP-100G-SR4-MM850-A |
850 |
MPO (PC polished, 12-fiber) |
Multimode, 50/125 |
2000 |
70 m (229.66 ft) |
4700 |
100 m (328.08 ft) |
Table4-6 QSFP28 copper cables available for the QSFP28 ports
QSFP28 copper cable |
Cable length |
QSFP-100G-D-CAB-1M |
1 m (3.28 ft) |
QSFP-100G-D-CAB-3M |
3 m (9.84 ft) |
QSFP-100G-D-CAB-5M |
5 m (16.40 ft) |
Table4-7 QSFP28 fiber cables available for the QSFP28 ports
QSFP28 fiber cable |
Cable length |
QSFP-100G-D-AOC-7M |
7 m (22.97 ft) |
QSFP-100G-D-AOC-10M |
10 m (32.81 ft) |
QSFP-100G-D-AOC-20M |
20 m (65.62 ft) |
Table4-8 QSFP28 to SFP28 copper cables available for the QSFP28 ports
QSFP28 to SFP28 copper cable |
Cable length |
QSFP-100G-4SFP-25G-CAB-1M |
1 m (3.28 ft) |
QSFP-100G-4SFP-25G-CAB-3M |
3 m (9.84 ft) |
QSFP-100G-4SFP-25G-CAB-5M |
5 m (16.40 ft) |
Table4-9 QSFP+ transceiver modules available for the QSFP28 ports
Central wavelength (nm) |
Connector |
Fiber type and diameter (µm) |
Modal bandwidth (MHz × km) |
Max transmission distance |
|
QSFP-40G-SR4-MM850 |
850 |
MPO (PC-polished, 12-core) |
Multimode, 50/125 |
2000 |
100 m (328.08 ft) |
4700 |
150 m (492.12 ft) |
||||
QSFP-40G-CSR4-MM850 |
850 |
MPO (PC-polished, 12-core) |
Multimode, 50/125 |
2000 |
300 m (984.25 ft) |
4700 |
400 m (1312.33 ft) |
||||
QSFP-40G-BIDI-SR-MM850 |
850 |
LC |
Multimode, 50/125 |
2000 |
100 m (328.08 ft) |
4700 |
150 m (492.12 ft) |
||||
QSFP-40G-LR4-WDM1300 |
Four lanes: · 1271 · 1291 · 1311 · 1331 |
LC |
Single mode, 9/125 |
N/A |
10 km (6.21 miles) |
QSFP-40G-LR4L-WDM1300 |
Four lanes: · 1271 · 1291 · 1311 · 1331 |
LC |
Single mode, 9/125 |
N/A |
2 km (1.24 miles) |
QSFP-40G-LR4-PSM1310 |
1310 |
MPO (PC-polished, 12-core) |
Single mode, 9/125 |
N/A |
10 km (6.21 miles) |
QSFP-40G-ER4-WDM1300 |
Four lanes: · 1271 · 1291 · 1311 · 1331 |
LC |
Single mode, 9/125 |
N/A |
40 km (24.86 miles) |
Table4-10 QSFP+ copper cables available for the QSFP28 ports
QSFP+ copper cable |
Max transmission distance |
LSWM1QSTK0 |
1 m (3.28 ft) |
LSWM1QSTK1 |
3 m (9.84 ft) |
LSWM1QSTK2 |
5 m (16.40 ft) |
Table4-11 QSFP+ fiber cables available for the QSFP28 ports
QSFP+ fiber cable |
Cable length |
QSFP-40G-D-AOC-7M |
7 m (22.97 ft) |
QSFP-40G-D-AOC-10M |
10 m (32.81 ft) |
QSFP-40G-D-AOC-20M |
20 m (65.62 ft) |
Table4-12 QSFP+ to SFP+ copper cables available for the QSFP28 ports
QSFP+ to SFP+ copper cable |
Max transmission distance |
LSWM1QSTK3 |
1 m (3.28 ft) |
LSWM1QSTK4 |
3 m (9.84 ft) |
LSWM1QSTK5 |
5 m (16.40 ft) |
The S6550X-32Q-HI switch provides four QSFP28 ports. The QSFP28 ports support the following transceiver modules and cables:
· QSFP28 transceiver modules in Table4-13.
· QSFP+ transceiver modules in .Table4-14.
Table4-13 QSFP28 transceiver modules available for the QSFP28 ports
QSFP28 transceiver module |
Central wavelength (nm) |
Connector |
Fiber type and diameter (µm) |
Modal bandwidth (MHz*km) |
Maximum transmission distance |
QSFP-100G-SR4-MM850 |
850 |
MPO (PC polished, 12-fiber) |
Multimode, 50/125 |
2000 |
70 m (229.66 ft) |
4700 |
100 m (328.08 ft) |
||||
QSFP-100G-LR4-WDM1300 |
Four lanes: · 1295 · 1300 · 1304 · 1309 |
LC |
Single mode, 9/125 |
N/A |
10 km (6.21 miles) |
QSFP-100G-LR4L-WDM1300 |
Four lanes: · 1264.5 to 1277.5 · 1284.5 to 1297.5 · 1304.5 to 1317.5 · 1324.5 to 1337.5 |
LC |
Single mode, 9/125 |
N/A |
2 km (1.24 miles) |
|
NOTE: MPO connectors include physical contact (PC) connectors with a flat-polished face and angle-polished contact (APC) connectors with an angle-polished face (8°). |
QSFP+ ports
IMPORTANT: You can use a QSFP-40G-SR4-MM850 transceiver module to connect a QSFP+ port to four SFP+ ports. The QSFP+ transceiver module and SFP+ transceiver modules to be connected must be the same in specifications, including central wavelength and fiber type. |
The S6550X-32Q-HI switch provides 28 QSFP+ ports. The QSFP+ ports support QSFP+ transceiver modules.
Table4-14 QSFP+ transceiver modules available for the QSFP+ ports
QSFP+ transceiver module |
Central wavelength (nm) |
Connector |
Fiber type and diameter (µm) |
Modal bandwidth (MHz × km) |
Max transmission distance |
QSFP-40G-SR4-MM850 |
850 |
MPO (PC-polished, 12-core) |
Multimode, 50/125 |
2000 |
100 m (328.08 ft) |
4700 |
150 m (492.12 ft) |
||||
QSFP-40G-CSR4-MM850 |
850 |
MPO (PC-polished, 12-core) |
Multimode, 50/125 |
2000 |
300 m (984.25 ft) |
4700 |
400 m (1312.33 ft) |
||||
QSFP-40G-BIDI-SR-MM850 |
850 |
LC |
Multimode, 50/125 |
2000 |
100 m (328.08 ft) |
4700 |
150 m (492.12 ft) |
||||
QSFP-40G-LR4-WDM1300 |
Four lanes: · 1271 · 1291 · 1311 · 1331 |
LC |
Single mode, 9/125 |
N/A |
10 km (6.21 miles) |
QSFP-40G-LR4L-WDM1300 |
Four lanes: · 1271 · 1291 · 1311 · 1331 |
LC |
Single mode, 9/125 |
N/A |
2 km (1.24 miles) |
QSFP-40G-BIDI-WDM850 |
Four lanes: · 850 · 880 · 910 · 940 |
MMF |
Multimode, 50/125 |
2000 |
240 m (787.40 ft) |
4700 |
350 m (1148.29 ft) |
SFP28 ports
The S6550XE-56HF-HI switch provides 48 SFP28 ports. The SFP28 ports support the following transceiver modules and cables:
· SFP28 transceiver modules in Table4-15.
· SFP28 copper cables in Table4-16.
· SFP28 fiber cables in Table4-17.
· 10-GE SFP+ transceiver modules in Table4-18.
· 10-GE SFP+ copper cables in Table4-19.
· 10-GE SFP+ fiber cables in Table4-20.
· GE SFP transceiver modules in Table4-3.
IMPORTANT: To connect an SFP28 port to a peer port that does not support speed and duplex autonegotiation, you must configure the same duplex mode and speed for the two ports. The speed must be the same as that of the transceiver module installed in the port. |
Table4-15 SFP28 transceiver modules available for the SFP28 ports
SFP28 transceiver module |
Central wavelength (nm) |
Connector |
Fiber type and diameter (µm) |
Modal bandwidth (MHz*km) |
Maximum transmission distance |
SFP-25G-SR-MM850 |
850 |
LC |
Multimode, 50/125 |
2000 |
· FEC negotiation disabled: 30 m (98.43 ft) · FEC negotiation enabled: 70 (229.66 ft) |
4700 |
· FEC negotiation disabled: 40 m (131.23 ft) · FEC negotiation enabled: 100 m (328.08 ft) |
||||
SFP-25G-LR-SM1310 |
1310 |
LC |
Single mode, 9/125 |
N/A |
10 km (6.21 miles) |
|
NOTE: For more information about FEC negotiation, see Ethernet interfaces in H3C S6550XE-HI Ethernet Switch Series Layer 2–LAN Switching Configuration Guide. |
Table4-16 25G SFP28 copper cables available for the SFP28 ports
25G SFP28 copper cable |
Max transmission distance |
SFP-25G-D-CAB-1M |
1 m (3.28 ft) |
SFP-25G-D-CAB-3M |
3 m (9.84 ft) |
SFP-25G-D-CAB-5M |
5 m (16.40 ft) |
Table4-17 25G SFP28 fiber cables available for the SFP28 ports
25G SFP28 fiber cable |
Max transmission distance |
SFP-25G-D-AOC-3M |
3 m (9.84 ft) |
SFP-25G-D-AOC-5M |
5 m (16.40 ft) |
SFP-25G-D-AOC-7M |
7 m (22.97 ft) |
SFP-25G-D-AOC-10M |
10 m (32.81 ft) |
SFP-25G-D-AOC-20M |
20 m (65.62 ft) |
Table4-18 10-GE SFP+ transceiver modules available for the SFP28 ports
10-GE SFP+ transceiver module |
Central wavelength (nm) |
Connector |
Fiber type and diameter (µm) |
Modal bandwidth (MHz × km) |
Max transmission distance |
SFP-XG-SX-MM850-E |
850 |
LC |
Multimode, 50/125 |
2000 |
300 m (984.25 ft) |
500 |
82 m (269.03 ft) |
||||
400 |
66 m (216.54 ft) |
||||
Multimode, 62.5/125 |
200 |
33 m (108.27 ft) |
|||
160 |
26 m (85.30 ft) |
||||
SFP-XG-SX-MM850-D |
850 |
LC |
Multimode, 50/125 |
2000 |
300 m (984.25 ft) |
500 |
82 m (269.03 ft) |
||||
400 |
66 m (216.54 ft) |
||||
Multimode, 62.5/125 |
200 |
33 m (108.27 ft) |
|||
160 |
26 m (85.30 ft) |
||||
SFP-XG-LX-SM1310-E |
1310 |
LC |
Single mode, 9/125 |
N/A |
10 km (6.21 miles) |
SFP-XG-LX-SM1310-D |
1310 |
LC |
Single mode, 9/125 |
N/A |
10 km (6.21 miles) |
SFP-XG-LX-SM1270-BIDI |
1270 |
LC |
Single mode, 9/125 |
N/A |
10 km (6.21 miles) |
SFP-XG-LX-SM1330-BIDI |
1330 |
LC |
Single mode, 9/125 |
N/A |
10 km (6.21 miles) |
SFP-XG-LH40-SM1270-BIDI |
1270 |
LC |
Single mode, 9/125 |
N/A |
40 km (24.86 miles) |
SFP-XG-LH40-SM1550 |
1550 |
LC |
Single mode, 9/125 |
N/A |
40 km (24.86 miles) |
SFP-XG-LH40-SM1330-BIDI |
1330 |
LC |
Single mode, 9/125 |
N/A |
40 km (24.86 miles) |
SFP-XG-LH80-SM1550-BIDI |
1550 |
LC |
Single mode, 9/125 |
N/A |
80 km (49.71 miles) |
SFP-XG-LH80-SM1490-BIDI |
1490 |
LC |
Single mode, 9/125 |
N/A |
80 km (49.71 miles) |
SFP-XG-LH80-SM1550 |
1550 |
LC |
Single mode, 9/125 |
N/A |