Title | Size | Downloads |
---|---|---|
LSQM3MPUB0 Card Manual-6PW105-book.pdf | 73.91 KB |
- Table of Contents
LSQM3MPUB0 management and route unit
1 Card identifier
The card identifier LSQM3MPUB0 is in the upper right corner of the front panel.
2 Specifications
|
IMPORTANT: Before installing the card, you must remove the protection cover from the card to ensure correct installation. |
Table 1 LSQM3MPUB0 specifications
Item |
Specifications |
Flash |
1 GB |
SDRAM (DDR3) |
2 GB |
Card size (H × W × D) |
40 × 399 × 355 mm (1.57 × 15.71 × 13.98 in) |
Power consumption |
36 W to 60 W |
Ports |
· 1 console port · 1 USB console port · 2 network management ports: 1 × 10/100/1000BASE-T copper ports and 1 SFP fiber ports · 1 USB port |
Port speed |
· Console port: £ 115200 bps (default: 9600 bps) · USB console port: ≤ 115200 bps (default: 9600 bps) · 10/100/1000BASE-T copper port: 10/100/1000 Mbps, half/full duplex · SFP fiber port: 1000 Mbps |
Transmission medium and max transmission distance |
· Console port: 15 m (49.21 ft) over ordinary asynchronous serial port cables. · USB console port: 10 m (32.81 ft) over USB-AB cables · 10/100/1000BASE-T copper port: 100 m (328.1 ft) over Category 5 or higher twisted pair cables · SFP fiber port: see Table 3 |
Compatible device models |
S7506E (non-PoE). |
Applicable host software versions |
Version 7150 and later |
|
NOTE: · To successfully connect an Ethernet port to a network management port (SFP port) on the card, make sure the Ethernet port is operating in full duplex mode and at the port speed of 1000 Mbps. · H3C recommends not using a USB extender cable to connect the USB port. |
The 10/100/1000BASE-T copper port uses an RJ-45 connector.
Figure 1 RJ-45 connector
Table 2 RJ-45 GE connector pinout
Pin |
10BASE-T/100BASE-TX/1000BASE-T |
|
Signal |
Function |
|
1 |
MX_0+ |
Transmits and receives data. |
2 |
MX_0- |
Transmits and receives data. |
3 |
MX_1+ |
Transmits and receives data. |
4 |
MX_2+ |
Transmits and receives data. |
5 |
MX_2- |
Transmits and receives data. |
6 |
MX_1- |
Transmits and receives data. |
7 |
MX_3+ |
Transmits and receives data. |
8 |
MX_3- |
Transmits and receives data. |
Table 3 describes the SFP transceiver modules available for the SFP ports on the card.
Table 3 SFP transceiver module specifications
Module |
Central wavelength |
Connector type |
Cable specifications |
Maximum transmission distance |
SFP-GE-SX-MM850-A |
850 nm |
LC |
50/125 μm multi-mode optical fiber |
550 m (0.34 miles) |
850 nm |
LC |
62.5/125 μm multi-mode optical fiber |
275 m (0.17 miles) |
|
SFP-GE-SX-MM850-D |
850 nm |
LC |
50/125 μm multi-mode optical fiber |
550 m (0.34 miles) |
850 nm |
LC |
62.5/125 μm multi-mode optical fiber |
275 m (0.17 miles) |
|
SFP-GE-LX-SM1310-A |
1310 nm |
LC |
9/125 μm single-mode optical fiber |
10 km (6.21 miles) |
1310 nm |
LC |
50/125 μm multi-mode optical fiber |
550 m (1804.46 ft) |
|
1310 nm |
LC |
62.5/125 μm multi-mode optical fiber |
550 m (1804.46 ft) |
|
SFP-GE-LX-SM1310-D |
1310 nm |
LC |
9/125 μm single-mode optical fiber |
10 km (6.21 miles) |
1310 nm |
LC |
50/125 μm multi-mode optical fiber |
550 m (1804.46 ft) |
|
1310 nm |
LC |
62.5/125 μm multi-mode optical fiber |
550 m (1804.46 ft) |
|
SFP-GE-LH40-SM1310 |
1310 nm |
LC |
9/125 μm single-mode optical fiber |
40 km (24.86 miles) |
SFP-GE-LH40-SM1310-D |
1310nm |
LC |
9/125 μm single-mode optical fiber |
40 km (24.86 miles) |
SFP-GE-LH40-SM1550 |
1550 nm |
LC |
9/125 μm single-mode optical fiber |
40 km (24.86 miles) |
SFP-GE-LH80-SM1550 |
1550 nm |
LC |
9/125 μm single-mode optical fiber |
70 km (43.50 miles) |
SFP-GE-LH80-SM1550-D |
1550nm |
LC |
9/125 μm single-mode optical fiber |
70 km (43.50 miles) |
SFP-GE-LH100-SM1550 |
1550 nm |
LC |
9/125 μm single-mode optical fiber |
100 km (62.14 miles) |
SFP-GE-LX-SM1310-BIDI |
RX: 1490 nm TX: 1310 nm |
LC |
9/125 μm single-mode optical fiber |
10 km (6.21 miles) |
SFP-GE-LX-SM1490-BIDI |
RX: 1310 nm TX: 1490 nm |
LC |
9/125 μm single-mode optical fiber |
10 km (6.21 miles) |
|
NOTE: · BIDI modules use different central wavelengths in transmit and receive directions, in order to implement bidirectional transmission of optical signals over the same fiber. · The BIDI modules must be used in pairs. For example, if you install the SFP-GE-LX-SM1310-BIDI in the local port, you must install the SFP-GE-LX-SM1490-BIDI in the peer port. |
3 Related documentation
For module installation, see H3C S7500E Switch Series Installation Guide.
For software upgrade, see the release notes for the device.
Copyright © 2014-2018 New H3C Technologies Co ., Ltd.