LSXM1SFF16A1 switching fabric module

1  Card identifier

The card identifier LSXM1SFF16A1 is at the upper right corner of the front panel.

2  Specifications

 

CAUTION

CAUTION:

This card can be used only with Type F interface cards, which have an F in their card identifiers (for example, LSXM1CGP12FX1). Card damage will occur if this card is used with an interface card that is not Type F.

 

Table 1 Card specifications

Item

Specification

Processor

MIPS64 (Dual Core) @ 1 GHz

SDRAM

4GB DDR3 SDRAM

Power consumption

138 W to 161 W

Compatible device models

S12516X-AF

Compatible interface cards

Type F interface cards

 

IMPORTANT

IMPORTANT:

·     To verify compatibility of the card with the software release you are using, see the release notes.

·     Only switching fabric modules of the same model can be installed on the same switch.

 

3  Installing and removing the card

 

CAUTION

CAUTION:

·     Remove the protection box from the card before you install the card.

·     You must install the cards before you install the fan tray, and remove the fan tray before you remove the cards.

·     The smart speed adjustment feature increases the fan speed when only one fan tray is operating. Take noise protection measures such as wearing an earmuff or earplug. In addition, make good preparation before hot swapping a switching fabric module to minimize the operation time.

·     Long-time exposure to strong air flow might cause discomfort. To avoid this hazard, do not stand close to the air outlet vents while the switch is operating. If you must be next to the switch on the air outlet vent side for an extended period, avoid the air flow or take other protective measures.

 

3.1  Installing the card

1.     Release the ejector levers by pressing the spring clips.

2.     Insert the card slowly into the slot until the brakes of the ejector levers touch the slot edges tightly.

3.     Simultaneously rotate the ejector levers inward until the spring clips lock the ejector levers in place and the card is completely seated in the slot.

3.2  Removing the card

1.     Release the ejector levers by pressing the spring clips.

2.     Simultaneously rotate the ejector levers outward and then pull out the card.

3.     Install a filler panel in a switching fabric module slot if you are not to install a switching fabric module in it.

4  Obtaining documentation

For card installation, see H3C S12500X-AF Switch Series Installation Guide.

To access the most up-to-date H3C product documentation, go to

http://www.h3c.com.hk/Technical_Documents

For software upgrade, see the release notes for the device.

To access the release notes, go to

http://www.h3c.com.hk/Software_Download

 

 

Copyright © 2017 New H3C Technologies Co., Ltd.

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become a Partner
  • Partner Resources
  • Partner Business Management
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网