- Released At: 18-11-2019
- Page Views:
- Downloads:
- Table of Contents
- Related Documents
-
MPU - LSUM1MPUS06XEC0
1 Card identifier
The card identifier LSUM1MPUS06XEC0 is in the upper right corner of the front panel.
2 Specifications
|
IMPORTANT: H3C recommends that you use only H3C-certified USB disks to ensure hardware reliability and compatibility. |
Table 1 Card specifications
Item |
Specifications |
Flash |
2 GB |
BootROM |
4 MB |
NVRAM |
1 MB |
SDRAM (DDR4) |
8 GB |
Card size (H × W × D) |
40 × 292 × 318 mm (1.57 × 11.50 × 12.52 in) |
Power consumption |
74 W to 135 W |
Ports |
· 1 console port · 1 USB console port · 4 network management ports: 2 RJ-45 ports and 2 SFP fiber ports · 1 primary USB port |
Port rate |
· Console port: 9600 bps to 115200 bps (default: 9600 bps) · USB console port: ≤ 115200 bps (default: 9600 bps) · network management ports ( RJ-45 ): 10/100/1000 Mbps, half/full duplex · network management ports (SFP ): 1000 Mbps |
Transmission medium and max transmission distance |
· Console port: 15 m (49.21 ft) over asynchronous EIA/TIA-232 cables · USB console port: 10 m (32.81 ft) over USB-AB cables · network management ports ( RJ-45 ): 100 m (328.08 ft) over Category 5 or higher twisted pair cables · network management ports (SFP ): GE SFP fiber module specifications |
Applicable hardware platforms |
S10506X |
Applicable host software versions |
Release 7585 and later |
|
NOTE: · The OFFLINE button on the MPU is intended for debugging and locating failures by technical supports. H3C recommends not using it without authorization. · H3C recommends not using a USB extender cable to connect the USB port. |
The 10/100/1000BASE-T copper port uses an RJ-45 connector.
Figure 1 RJ-45 connector
Table 2 RJ-45 GE connector pinout
Pin |
10BASE-T/100BASE-TX/1000BASE-T |
|
Signal |
Function |
|
1 |
MX_0+ |
Transmits and receives data. |
2 |
MX_0- |
Transmits and receives data. |
3 |
MX_1+ |
Transmits and receives data. |
4 |
MX_2+ |
Transmits and receives data. |
5 |
MX_2- |
Transmits and receives data. |
6 |
MX_1- |
Transmits and receives data. |
7 |
MX_3+ |
Transmits and receives data. |
8 |
MX_3- |
Transmits and receives data. |
|
IMPORTANT: For more information about transceiver modules and cables available for the card, see H3C S10500X Switch Series Cards and Transceiver Modules Compatibility Matrixes. |
3 Related documentation
For module installation, see H3C S10500X Switch Series Installation Guide.
For software upgrade, see the release notes for the device.
Copyright © 2018 New H3C Technologies Co., Ltd.
The information in this document is subject to change without notice.