H3C UniServer R4900 G5 Server Ecodesign Manual-6PW105

HomeSupportServersH3C UniServer R4900 G5Install & UpgradeCompliance and Safety InformationH3C UniServer R4900 G5 Server Ecodesign Manual-6PW105
Download Book
  • Released At: 22-03-2024
  • Page Views:
  • Downloads:
Table of Contents
Related Documents

H3C IT RACK Series Product Information for Ecodesign Requirements of (EU) 2019/424

Regulatory Reference: COMMISSION REGULATION (EU) 2019/424, implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to Ecodesign requirements for servers and online data storage products.

Product Type

Sever

Manufacturer

New H3C Technologies Co., Ltd

Trade

H3C

Address

466 Changhe Road, Binjiang, 310052 Hangzhou, PEOPLE'S REPUBLIC OF CHINA

Product Model

H3C UniServer R4900 G5

Year of Manufacture

2019

PSU Efficiency

PSU model

PSR850-12A

Rated Output

+12V/70.8A,+12VSB/2.1A

Rated Load

10%

20%

50%

100%

PSU Efficiency

9199%

95.25%

96.13%

94.4%

Power Factor

-

-

0.99

-

 

PSU model

CRPS1600C2

Rated Output

+12.2V/132A,+12VSB/3.0A

Rated Load

10%

20%

50%

100%

PSU Efficiency

92.53%

95.65%

96.16%

93.89%

Power Factor

-

-

0.99

-

 

Note1: DC-DC internal power supplies don’t need to fill in the form.

Note2: External Power Supplies (EPS) are regulated as a separate component in the European Union and a separate compliance document is required for EPSs. Leave Internal Power Supply test data fields blank for products that use an EPS (and that do not use an internal power supply).

Idle State Power (W) and Active state efficiency

The test for Idle State power and Active State Efficiency is based on ETSI EN 303 470 V1.1.1 (2019-03)- Environmental Engineering (EE); Energy Efficiency measurement methodology and metrics for servers.

Configuration

Idle State Power (W)

Active state efficiency

Low-end performance configuration

519.52

302.6

High-end performance configuration

532.32

312.1

Note: SERT Active State Efficiency must be higher to pass to table 5 of the Regulation. SERT Idle State Power must be lower than the calculated limit to pass- described in Annex II 2.1 of the Regulation.

Components List for additional idle power allowances

System characteristics

Quantity

Additional Idle Power Allowances

CPU Performance

2

15.4

Additional PSU

0

0

HDD or SSD

3

15

Additional Memory (GB)

2044

367.92

Additional buffered DDR Channel

24

96

Additional I/O devices

0

0

Total additional idle power allowances

/

494.32

Maximum Power (W)

Configuration

Maximum Power

Low-end performance configuration

519.52

High-end performance configuration

532.32

Operating Condition Class    

 

Dry bulb temp °C

Humidity range, non-condensing

 

 

Operating Condition Class

Allowable Range

Recommended Range

Allowable Range

Recommended Range

Max Dew Point (°C)

Maximum rate of Change (°C/hr)

A4

5-45

18-27

-12 °C DP and 8 % RH to 24 °C DP and 90 % RH

-9 °C DP to 15 °C DP and 60 % RH

24

5/20

 

Idle State Power at the higher boundary temperature of the declared operating condition class

Configuration

Idle State Power

Low-end performance configuration

519.52

High-end performance configuration

532.32

List of all model configurations   

Computing

2×3rd generation  Intel® Xeon® Scalable processors

(Up to 40 cores and maximum 270 W power consumption)

Memory

32 × DDR4 DIMMs, 12.0 TB (maximum)

(Up to 3200 MT/s data transfer rate and support for both RDIMM and LRDIMM)

(Up to 16 Intel ® Optane™ DC Persistent Memory Module PMem 200 series .( Barlow Pass)

Storage

Support up to Front 12LFF bays, Internal 4LFF bays , Rear 4LFF+4SFF bays

Support up to Front 25SFF bays, Internal 8SFF bays , Rear 4LFF+4SFF bays

Support Front/Internal  SAS/SATA HDD/SSD/NVMe Drives

Maximum 28 x U.2 NVMe Drives

PCIe NVMe storage accelerator, SATA/PCIe M.2 SSDs, 2 × SD Internal slots (Optional)

GPU

14 × single-slot wide or 4 × double-slot GPU modules

Note: The configurations of server product family are end-user configurable / selectable, the detail can be found at http://www.h3c.com

The Concentration of Cobalt and Neodymium

Item

Description

Cobalt in battery

Less than 5g

Neodymium in HDD

between 5 g and 25 g

Disassembly Operations

Operation Type

Description

Data Storage Device

Release buckle

Memory

Release buckle

CPU

Remove Screw

Motherboard

Release buckle

Expansion/Graphic Card

Release buckle

PSU

Release buckle

Chassis

Release buckle

Batteries

Release buckle

Fastening technique type

Quantity

Required Tool

Trox Screw

24

Trox Screw Driver T15

Trox Screw

8

Trox Screw Driver T10

Trox Screw

4

Trox Screw Driver T30

Philps Screw

2

Philps Screw Driver #2

Buckle

76

/

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网