H3C CR-19K-MPU-20B main processing unit

1  Identifier

The module identifier CR-19K-MPU-20B is on the far right of the front panel.

2  About the MPU

The CR-19K-MPU-20B main processing unit (MPU) is applicable to the CR19000-20 and CR19000-MC core routers. It provides the following functionalities:

·     Route calculation and forwarding table maintenance.

·     System configuration, control, and monitoring. On the MPU, you can monitor, upgrade software, and reset a module.

·     High-precision clock and time synchronization.

·     Real-time clock (RTC) that keeps tracks of the current time, providing seconds, minutes, hours, day, date, month, and year information.

·     Support for active/standby switchover when two MPUs are installed on the router.

 

IMPORTANT

IMPORTANT:

If you install two MPUs for the router, make sure they are the same model.

 

Figure 1 Front panel

(1) 1PPS/ToD time synchronization ports 1 and 2

(2) SMB clock output ports 1 and 2

(3) SMB clock input ports 1 and 2

(4) Fan tray status LEDs

(5) Power supply status LEDs

(6) Module status LED

(7) MPU active/standby status LED

(8) Module identifier (CR-19K-MPU-20B)

(9) Reset button

(10) Hard disk status LED

(11) System alarm LED

(12) Console port (CONSOLE)

(13) EXT ports and LEDs

(14) USB 2.0 port

(15) Management port and LED (MANAGEMENT)

(16) 10GBASE-R-SFP+ ports and LEDs 1 to 4

 

Table 1 MPU specifications

Item

Specifications

Processor

Eight-core @ 2.6 GHz

DRAM size

32 GB

Hard disk

240 GB

Dimensions (H × W × D)

40 × 433 × 512 mm (1.57 × 17.05 × 20.16 in)

Power consumption

230 W

Hot swapping

Supported

Ports

·     1 × console port

·     1 × USB 2.0 port (Type A, host mode)

·     1 ×10/100/1000BASE-T management port

·     4 × 10GBASE-R-SFP+ ports

·     2 × 1PPS/ToD time synchronization ports

·     2 × SMB clock input ports

·     2 × SMB clock output ports

·     EXT ports:

¡     1 × 10/100/1000BASE-T BMC port

¡     ETH ports: 1 × 10/100/1000BASE-T port and 2 × 10GBASE-R-SFP+ ports

¡     1 × USB 2.0 port (Type A)

Interface transmission rate

·     Console port: 9600 (default) to 115200 bps

·     10/100/1000BASE-T management port: 10/100/1000 Mbps

·     10GBASE-R-SFP+port: 10 Gbps

·     10/100/1000BASE-T BMC port: 10/100/1000 Mbps

·     ETH ports:

¡     10/100/1000BASE-T port: 10/100/1000 Mbps

¡     10GBASE-R-SFP+ port: 10 Gbps

Reset button

1

 

IMPORTANT

IMPORTANT:

·     To verify compatibility of the MPU with the software release you are using, see the release notes.

·     For the transceiver modules and cables available for the MPU, see H3C CR19000 Core Routers Modules and Transceivers Compatibility Matrixes.

 

 

Copyright © 2022 New H3C Technologies Co., Ltd.

The information in this document is subject to change without notice.

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become a Partner
  • Partner Resources
  • Partner Business Management
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网