Overview

An MPU provides the following functions:

·     Route calculation and forwarding table maintenance.

·     System configuration and monitoring. It can monitor, upgrade, and reset the service modules.

·     Active/standby switchover.

The following MPUs are available for the CR16000-M routers.

Table 1 MPUs available for the CR16000-M routers

Module model

Description

SR07MPUA3-M

H3C CR16000-M main processing unit

 

Key features

High performance routing engine

The MPUs employ domestic high performance multi-CPUs to provide powerful routing processing capability and powerful message processing capability for protocol messages and control messages.

Flexible configuration and compatibility

You can install one or two MPUs for the router. When two MPUs are installed, the router supports active/standby MPU switchover.

Hot swapping

You can install an MPU when the router is operating. When two MPUs are installed, you can remove one of them, without interrupting the interface module services. The management system performs real-time monitoring on the MPUs and automatically adapts to the changed configuration upon detection of the change, ensuring service continuity.

Specifications

CAUTION

CAUTION:

For the standby MPU to start up correctly, make sure the active and standby MPUs are the same model.

 

The figures in this section are for illustration only.

Figure 1 SR07MPUA3-M

 

Front panel

Figure 2 SR07MPUA3-M front panel

(1) Management Ethernet port LED (LINK, see Table 2 for the description)

(2) Network management port LED (ACT, see Table 2 for the description)

(3) USB 2.0 port

(4) Console port

(5) High-precision time synchronization port

(6) SMB coaxial clock input port

(7) SMB coaxial clock output port

(8) Power module status LED (see Table 3 for the description)

(9) Fan tray status LED (see Table 4 for the description)

(10) MPU alarm status LED (see Table 5 for the description)

(11) MPU active/standby status LED (see Table 6 for the description)

(12) MPU status LED (see Table 7 for the description)

(13) Reset button

(14) 1000BASE-T management Ethernet port

 

Technical specifications

Item

Specifications

SDRAM

2 × 8 GB

Dimensions (H × W × D)

22 × 214 × 262 mm (0.87 × 8.43 × 10.32 in)

Net weight

1.2 kg (2.65 lb)

Power consumption

46 W to 53 W

Ports

·     1 × console port

·     1 × network management port

·     1 × USB 2.0 port

·     1 × SMB coaxial clock output port

·     1 × SMB coaxial clock input port

·     1 × high-precision time synchronization port. By default, the port is an input port.

For the port specifications, see "Ports."

System software version

8281 or later

 

LEDs

Management Ethernet port LEDs

Table 2 Management Ethernet port LED description

LINK LED status

ACT LED status

Description

Steady green

Flashing yellow

The port is sending or receiving data.

Steady green

Off

A link is present.

Off

Off

No link is present.

 

Power module status LED

Table 3 Power module status LED description

Mark

Status

Description

PWR

Steady green

All power modules in the chassis are operating correctly.

Steady red

A minimum of one power module in the chassis does not have power output. Possible reasons include:

·     Power module failure.

·     Power switch is turned off.

·     Power cord connection error.

·     Outage of the external power source.

Off

·     No power module is present in the chassis.

·     No power modules in the chassis have power output. Possible reasons include:

¡     Power module failure.

¡     Power switch is turned off.

¡     Power cord connection error.

¡     Outage of the external power source.

 

Fan tray status LED

Table 4 Fan tray status LED description

Mark

Status

Description

FAN

Steady green

The fan tray is operating correctly.

Steady red

An issue has occurred on the fan tray or the fan tray is not installed securely.

Off

The fan tray is not powered on.

 

MPU alarm status LED

Table 5 MPU alarm status LED description

Mark

ALM LED status

Description

ALM

Steady on

The MPU is starting up or is faulty.

Flashing at 0.25 Hz

The temperature of the module exceeds the upper warning threshold or falls below the lower warning threshold.

Off

The MPU is operating correctly or is not powered on.

 

MPU active/standby status LED

Table 6 MPU active/standby status LED description

Mark

Status

Description

ACT

Steady on

The MPU is in active status.

Off

·     The MPU is in standby status.

·     The MPU is faulty. To identify whether the MPU is faulty or in standby status, examine the MPU status LED.

 

MPU status LED

Table 7 MPU status LED description

Mark

Status

Description

RUN

Flashing at 0.5 Hz

The MPU is operating correctly.

Fast flashing at 4 Hz

The MPU is starting up.

Steady on

The MPU is faulty.

Off

The MPU is not powered on.

 

Ports

Console port

The console port uses an RJ-45 connector and can be connected to a computer for system debugging, configuration, maintenance, management, and software loading.

Table 8 Console port specifications

Item

Specifications

Connector type

RJ-45

Port standard

Asynchronous EIA/TIA-232

Baud rate

£ 115200 bps. The default setting is 9600 bps.

NOTE:

The baud rate is configurable.

Transmission medium and max transmission distance

15 m (49.21 ft) over an ordinary asynchronous serial cable

Supported services

Connects to the serial port of a local PC to run the terminal emulation program

 

Management Ethernet port

The management Ethernet port can be connected to a computer for program loading and debugging, or connected to a remote NMS for management.

Table 9 Management Ethernet port specifications

Item

Specifications

Connector type

RJ-45

Ports

1

Port speed

1000 Mbps, full duplex

Transmission medium and max transmission distance

100 m (328.08 ft) over a Category 5 or higher twisted pair cable

Supported services

Software upgrade and network management

 

USB port

CAUTION

CAUTION:

Use the USB port only for file storage on portable storage devices, such as a USB disk. Charging portable devices through the USB port might cause an MPU failure.

 

IMPORTANT

IMPORTANT:

As a best practice, use only H3C-certified USB disks to ensure hardware reliability and compatibility.

 

Table 10 USB port specifications

Item

Specifications

Connector type

USB-A

Port standard

USB 2.0 (12 Mbps at full speed, 1.5 Mbps at low speed)

Supported service

Connects to external storage medium.

 

SMB coaxial clock input/output port

SMB coaxial clock ports provide input or output clock references at 2.048 Mbps (2.048 MHz). You can set the data rate mode or frequency mode through the DIP switches on the panel. Two of them are input ports and two are output ports.

Table 11 SMB coaxial clock input/output port specifications

Item

Specifications

Connector type

SMB coaxial

Port standard

GJB681

Port speed

2.048 Mbps

Transmission medium

75 ohm coaxial cables

Supported services

Sends and receives 2.048 MHz clocks and 2.048 Mbps signals to synchronize the clocks of the router and other devices, such as routers and the terminals.

 

High-precision time synchronization port

Table 12 High-precision time synchronization port specifications

Item

Specifications

Connector

RJ-45

Port standard

QB-B-016-2010

Port speed

9600 bps

Transmission medium

Category 5 or higher twisted pair cables

Supported services

·     Synchronizes the clocks of the router and other devices, such as GPS receivers and terminals.

·     You can configure the port as an input port or output port at the CLI.

 

Environment requirements

Make sure the ambient environment meets the following requirements:

·     Temperature and humidity requirements

Table 13 Temperature and humidity requirements

Item

Specifications

Operating temperature

0°C to 45°C (32°F to 113°F)

Storage temperature

–40°C to +70°C (–40°F to +158°F)

Operating humidity

5% RH to 95% RH, non-condensing

Storage humidity

5% RH to 95% RH, non-condensing

 

·     Dust protection requirements

Table 14 Dust concentration limits in the equipment room

Substance

Particle diameter

Concentration limit

Dust particles

≥ 0.5 µm

≤ 1.8 × 107 particles/m3

 

·     Corrosive gas protection requirements

Table 15 Corrosive gas concentration limits in the equipment room

Gas

Average concentration (mg/m3)

Maximum concentration (mg/m3)

SO2

0.3

1.0

H2S

0.1

0.5

Cl2

0.1

0.3

HCI

0.1

0.5

HF

0.01

0.03

NH3

1.0

3.0

O3

0.05

0.1

NOX

0.5

1.0

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become a Partner
  • Partner Resources
  • Partner Business Management
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网