- Released At: 13-10-2022
- Page Views:
- Downloads:
- Table of Contents
- Related Documents
-
|
H3C CR16000-M Router Series |
CPOS Interface Module Datasheet |
|
|
Copyright © 2022 New H3C Technologies Co., Ltd. All rights reserved.
No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of New H3C Technologies Co., Ltd.
Except for the trademarks of New H3C Technologies Co., Ltd., any trademarks that may be mentioned in this document are the property of their respective owners.
The information in this document is subject to change without notice.
Contents
Overview
The following CPOS interface modules are available for the CR16000-M routers.
Table 1 CPOS interface modules available for the CR16000-M routers
Module model |
Description |
MIC-CLP4L-M |
4-port OC-3/STM-1 (155M) channelized POS optical interface module |
Key features
Bandwidth channelization
MP-group supported
The CPOS interface supports multilink PPP group (MP-Group). An MP-group can be used as a logical interface to carry the traffic of various services, providing multiple options for bandwidth and line selection.
Encapsulation
The CPOS interface supports PPP or HDLC encapsulation.
Specifications
The figures in this section are for illustration only.
Front panel
Figure 2 MIC-CLP4L-M front panel
(1) CPOS-OC-3/STM-1-SFP fiber ports (4 in total) |
(2) Module status LED (see Table 2 for the description) |
(3) Port LED (see Table 3 for the description) |
Technical specifications
Item |
Specifications |
Dimensions (H × W × D) |
22 × 214 × 262 mm (0.87 × 8.43 × 10.32 in) |
Power consumption |
32 W to 35 W |
Ports |
4 × OC-3c/STM-1c-SFP POS fiber ports |
Connector type |
LC |
Port speed |
155 Mbps (OC-3c/STM-1c) |
LEDs
Table 2 Module status LED description
Mark |
Status |
Description |
RUN |
Flashing at 0.5 Hz |
The interface module is operating correctly. |
Fast flashing at 4 Hz |
The interface module is loading software. If the LED keeps flashing fast, software loading fails. |
|
On |
The interface module is faulty. |
|
Off |
The interface module is faulty or is not powered on. |
Mark |
Status |
Description |
ACT/ALM |
Flashing green |
The port is sending or receiving data. |
Steady green |
A link is present. |
|
Steady red |
An alarm has occurred. |
|
Off |
No link is present. |
Environment requirements
Make sure the ambient environment meets the following requirements:
· Temperature and humidity requirements
Table 4 Temperature and humidity requirements
Item |
Specifications |
Operating temperature |
0°C to 45°C (32°F to 113°F) |
Storage temperature |
–40°C to +70°C (–40°F to +158°F) |
Operating humidity |
5% RH to 95% RH, non-condensing |
Storage humidity |
5% RH to 95% RH, non-condensing |
· Dust protection requirements
Table 5 Dust concentration limits in the equipment room
Substance |
Particle diameter |
Concentration limit |
Dust particles |
≥ 0.5 µm |
≤ 1.8 × 107 particles/m3 |
· Corrosive gas protection requirements
Table 6 Corrosive gas concentration limits in the equipment room
Gas |
Average concentration (mg/m3) |
Maximum concentration (mg/m3) |
SO2 |
0.3 |
1.0 |
H2S |
0.1 |
0.5 |
Cl2 |
0.1 |
0.3 |
HCI |
0.1 |
0.5 |
HF |
0.01 |
0.03 |
NH3 |
1.0 |
3.0 |
O3 |
0.05 |
0.1 |
NOX |
0.5 |
1.0 |