Contents
Super-large switching capacity
Load sharing, redundancy and seamless extension
CSFC-04-1/CSFC-04-2/CSFC-04-3/CSFC-04-4
Overview
The following switching fabric modules are available for the CR16000-F routers.
Table 1 Switching fabric modules available for the CR16000-F routers
Module type |
Module model |
Description |
Type A |
CSFC-04-1 |
CR16006-F fabric card Slot 1 |
CSFC-04-2 |
CR16006-F fabric card Slot 2 |
|
CSFC-04-3 |
CR16006-F fabric card Slot 3 |
|
CSFC-04-4 |
CR16006-Ffabric card Slot 4 |
|
Type B |
CSFC-04B |
CR16006-F switch fabric card (B Type) |
CSFC-08B |
CR16010-F switch fabric card (B Type) |
|
CSFC-12B |
CR16014-F switch fabric card (B Type) |
|
Type D |
CSFC-04D |
CR16006-F switch fabric card (D Type) |
CSFC-08D |
CR16010-F switch fabric card (D Type) |
|
CSFC-12D |
CR16014-F switch fabric card (D Type) |
|
Type E |
CSFC-08E |
CR16010-F fabric module (E Type) |
CSFC-08E1 |
CR16010H-F fabric module (E Type) |
|
CSFC-08E1A |
CR16010H-FA fabric module (E Type) |
|
CSFC-12E |
CR16014-F fabric module (E Type) |
|
CSFC-16EA |
CR16018-FA fabric module (E Type) |
|
CSFC-16E |
CR16018-F fabric module (E Type) |
|
Type T |
CSFC-08T |
CR16010H-F fabric module (T Type) |
CSFC-16T CSFC-16T1 |
CR16018-F fabric module (T Type) |
|
Type TG |
CSFC-08T-G |
CR16010H-F fabric module (Type T-G) |
CSFC-16T-G |
CR16018-F fabric module (Type T-G) |
|
NOTE: · If Type A switching fabric modules are used, use the four types together and install each into its specified slot. Each Type A switching fabric module has a mark specifying the slot for installation. For example, the CSFC-04-1 has the mark Notes:Please insert to Slot 6. · If you use Type B, Type D, Type E, Type T, or Type TG switching fabric modules for the router, a minimum of two are required. You must install one in the lowest numbered slot. Then the two highest numbered slots are preferred. · Do not install switching fabric modules of different types on the same router. · For switching fabric module and service module compatibility matrix, see H3C CR16000-F Routers Installation Guide. |
Key features
Module variety
Various types of switching fabric modules provide users with different switching capabilities.
Super-large switching capacity
An SR8800-X router supports a maximum of five independent switching fabric modules according to users' bandwidth. Each slot provides a uni-directional bandwidth of level T.
Load sharing, redundancy and seamless extension
The SR8800-X routers support multi-plane switching architecture, and load sharing and redundancy among the planes, which extends port rates and port numbers seamlessly.
Hot swapping
The switching fabric modules are hot swappable. You can install or remove the switching fabric modules as needed. If the remaining switching capacity is sufficient, removing a switching fabric module does not affect service forwarding on service modules.
Specifications
The figures in this section are for illustration only.
CSFC-04-1/CSFC-04-2/CSFC-04-3/CSFC-04-4
The CSFC-04-1, CSFC-04-2, CSFC-04-3, and CSFC-04-4 fabric modules are the same in appearance except the mark. This section uses the CSFC-04-1 fabric module as an example.
Front panel
Figure 2 CSFC-04-1 front panel
Technical specifications
Item |
Specifications |
Dimensions (H × W × D) |
40 × 256 × 298 mm (1.57 × 10.08 × 11.73 in) |
Power consumption |
N/A |
Ports |
N/A |
Net weight |
1 kg (2.20 lb) |
System software version |
7133 or later |
CSFC-04B/CSFC-04D
The CSFC-04B and CSFC-04D fabric modules are the same in appearance except the mark. This section uses the CSFC-04B fabric module as an example.
Figure 3 CSFC-04B
Front panel
Figure 4 CSFC-04B front panel
(1) Switching fabric module status LEDs |
(2) Console port |
Technical specifications
Item |
Specifications |
Dimensions (H × W × D) |
40 × 256 × 298 mm (1.57 × 10.08 × 11.73 in) |
Power consumption |
· CSFC-04B: 48 W to 65 W · CSFC-04D: 60 W to 80 W |
Ports |
1 console port This port is provided only for H3C technical support engineers to perform maintenance and updates. Operations without permission are not allowed. H3C will not be liable for any consequences caused thereby. |
Connector type |
RJ-45 |
Net weight |
1.71 kg (3.77 lb) |
System software version |
7121 or later |
CSFC-08B/CSFC-08D
The CSFC-08B and CSFC-08D fabric modules are the same in appearance except the mark. This section uses the CSFC-08B fabric module as an example.
Figure 5 CSFC-08B
Front panel
Figure 6 CSFC-08B front panel
(1) Console port |
(2) Switching fabric module status LEDs |
Technical specifications
Item |
Specifications |
Dimensions (H × W × D) |
40 × 426 × 298 mm (1.57 × 16.77 × 11.73 in) |
Power consumption |
· CSFC-08B: 44 W to 60 W · CSFC-08D: 101 W to 135 W |
Ports |
1 console port This port is provided only for H3C technical support engineers to perform maintenance and updates. Operations without permission are not allowed. H3C will not be liable for any consequences caused thereby. |
Connector type |
RJ-45 |
Net weight |
· CSFC-08B: 2.5 kg (5.51 lb) · CSFC-08D: 2.77 kg (6.11 lb) |
System software version |
7121 or later |
CSFC-12B/CSFC-12D
The CSFC-12B and CSFC-12D fabric modules are the same in appearance except the mark. This section uses the CSFC-12B fabric module as an example.
Figure 7 CSFC-12B
Front panel
Figure 8 CSFC-12B front panel
(1) Console port |
(2) Switching fabric module status LEDs |
Technical specifications
Item |
Specifications |
Dimensions (H × W × D) |
40 × 602 × 298 mm (1.57 × 23.70 × 11.73 in) |
Power consumption |
· CSFC-12B: 107 W to 140 W · CSFC-12D: 195 W to 255 W |
Ports |
1 console port This port is provided only for H3C technical support engineers to perform maintenance and updates. Operations without permission are not allowed. H3C will not be liable for any consequences caused thereby. |
Connector type |
RJ-45 |
Net weight |
· CSFC-12B: 3.98 kg (8.77 lb) · CSFC-12D: 4.51 kg (9.94 lb) |
System software version |
7121 or later |
CSFC-08E
Figure 9 CSFC-08E
Front panel
Figure 10 CSFC-08E front panel
(1) Switching fabric module status LEDs |
Technical specifications
Item |
Specifications |
Dimensions (H × W × D) |
40 × 426 × 298 mm (1.57 × 16.77 × 11.73 in) |
Power consumption |
73 W to 140 W |
Ports |
N/A |
Net weight |
3.55 kg (7.83 lb) |
System software version |
7606 or later |
CSFC-08E1/CSFC-08E1A/CSFC-08T
The CSFC-08E1, CSFC-08E1A, and CSFC-08T fabric modules are the same in appearance except the mark. This section uses the CSFC-08E1 fabric module as an example.
Figure 11 CSFC-08E1
Front panel
Figure 12 CSFC-08E1 front panel
(1) Status LED |
|
Technical specifications
Item |
Specifications |
Dimensions (H × W × D) |
40 × 562 × 298 mm (1.57 × 22.13 × 11.73 in) |
Power consumption |
· CSFC-08E1/CSFC-08E1A: 75 W to 125 W · CSFC-08T: 100 W to 129 W |
Net weight |
5.15 kg (11.35 lb) |
Applicable system software versions |
· CSFC-08E1/CSFC-08T: 7751 or later · CSFC-08E1A: 7951P01 or later |
CSFC-12E
Figure 13 CSFC-12E
Front panel
Figure 14 CSFC-12E front panel
(1) Console port |
(2) Air inlet vents |
(3) Switching fabric module status LEDs |
Technical specifications
Item |
Specifications |
Dimensions (H × W × D) |
40 × 602 × 298 mm (1.57 × 23.70 × 11.73 in) |
Power consumption |
146 W to 178 W |
Ports |
1 console port This port is provided only for H3C technical support engineers to perform maintenance and updates. Operations without permission are not allowed. H3C will not be liable for any consequences caused thereby. |
Connector type |
RJ-45 |
Net weight |
5.30 kg (11.68 lb) |
System software version |
7601 or later |
CSFC-16T/CSFC-16T1/CSFC-16E/CSFC-16EA
The CSFC-16T, CSFC-16T1, CSFC-16E, and CSFC-16EA fabric modules are the same in appearance except the mark. This section uses the CSFC-16T1 fabric module as an example.
Figure 15 CSFC-16T1
Front panel
Figure 16 CSFC-16T1 front panel
(1) Status LED |
Technical specifications
Item |
Specifications |
Dimensions (H × W × D) |
40 × 961 × 298 mm (1.57 × 37.83 × 11.73 in) |
Power consumption |
· CSFC-16T/CSFC-16EA/CSFC-16T1: 267 W to 402 W · CSFC-16E: 159 W to 248 W |
Net weight |
· CSFC-16E: 9.35 kg (20.61 lb) · CSFC-16T: 10.25 kg (22.60 lb) · CSFC-16T1/CSFC-16EA: 11.50 kg (25.35 lb) |
Applicable system software versions |
· CSFC-16T: 7751 or later · CSFC-16E: 7606 or later · CSFC-16T1/CSFC-16EA: 8216 or later |
CSFC-08T-G
Figure 17 CSFC-08T-G
Front panel
Figure 18 CSFC-08T-G front panel
(1) Status LED |
Technical specifications
Item |
Specifications |
Dimensions (H × W × D) |
40 × 562 × 298 mm (1.57 × 22.13 × 11.73 in) |
Power consumption |
73 W to 150 W |
Ports |
N/A |
Net weight |
5.20 kg (11.46 lb) |
Applicable system software versions |
8308 or later |
CSFC-16T-G
Figure 19 CSFC-16T-G
Front panel
Figure 20 CSFC-16T-G front panel
(1) Status LED |
Technical specifications
Item |
Specifications |
Dimensions (H × W × D) |
40 × 961 × 298 mm (1.57 × 37.83 × 11.73 in) |
Power consumption |
100 W to 120 W |
Net weight |
10.45 kg (23.04 lb) |
Applicable system software versions |
8315 or later |
LEDs
The CSFC-16E, CSFC-16EA, CSFC-08E1, CSFC-08E1A, Type T, and Type T-G switching fabric modules each use a status LED RUN to indicate their operating status. For the status LED description of these switching fabric modules, see Table 2.
The other switching fabric modules each use a pair of LEDs RUN and ALM to indicate their operating status. For the status LED description of these switching fabric modules, see Table 3.
Table 2 Switching fabric module status LED description (1)
RUN LED status |
Description |
Flashing (0.5 Hz) |
The switching fabric module is operating correctly. |
Flashing (8 Hz) |
The switching fabric module is starting up. |
Off |
The switching fabric module has not started up. |
Table 3 Switching fabric module status LED description (2)
RUN LED status |
ALM LED status |
Description |
Flashing (0.5 Hz) |
Off |
The switching fabric module is operating correctly. |
Off |
Steady on |
The switching fabric module is faulty. |
Flashing (0.5 Hz) |
Steady on |
The temperature of the switching fabric module has exceeded the upper limit or dropped below the lower limit. |
Off |
Off |
The switching fabric module has not started up. |
Steady on |
Off |
The switching fabric module is starting up. |
Environment requirements
Make sure the ambient environment meets the following requirements:
· Temperature and humidity requirements
Table 4 Temperature and humidity requirements
Item |
Specifications |
Operating temperature |
0°C to 45°C (32°F to 113°F) |
Storage temperature |
–40°C to +70°C (–40°F to +158°F) |
Operating humidity |
10% RH to 95% RH, non-condensing |
Non-operating humidity |
5% RH to 95% RH, non-condensing |
· Dust protection requirements
Table 5 Dust concentration limits in the equipment room
Substance |
Particle diameter |
Concentration limit |
Dust particles |
≥ 0.5 µm |
≤ 1.8 × 107 particles/m3 |
· Corrosive gas protection requirements
Table 6 Corrosive gas concentration limits in the equipment room
Gas |
Average concentration (mg/m3) |
Maximum concentration (mg/m3) |
SO2 |
0.3 |
1.0 |
H2S |
0.1 |
0.5 |
Cl2 |
0.1 |
0.3 |
HCI |
0.1 |
0.5 |
HF |
0.01 |
0.03 |
NH3 |
1.0 |
3.0 |
O3 |
0.05 |
0.1 |
NOX |
0.5 |
1.0 |