H3C CR16000-F Routers Network Data Encryption Service Processing Unit Datasheet-5W102-book.pdf(385.97 KB)
- Released At: 12-12-2022
- Page Views:
- Downloads:
- Table of Contents
- Related Documents
-
|
H3C CR16000-F Router Series |
Network Data Encryption Service Processing Unit Datasheet |
|
|
Copyright © 2022 New H3C Technologies Co., Ltd. All rights reserved.
No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of New H3C Technologies Co., Ltd.
Except for the trademarks of New H3C Technologies Co., Ltd., any trademarks that may be mentioned in this document are the property of their respective owners.
The information in this document is subject to change without notice.
Contents
Overview
Table 1 lists the network data encryption service processing units available for the CR16000-F routers.
Table 1 Network data encryption service processing units available for the CR16000-F routers
Model |
Description |
IM-SFMX |
Network data encryption service processing unit |
MIC-SM |
Network data encryption interface card |
|
NOTE: For compatibility between network data encryption service processing units and switching fabric modules, see "Appendix B FRUs and compatibility matrixes" in H3C CR16000-F Routers Installation Guide. |
Key features
The network data encryption service processing unit and network data encryption interface card use the digital physical noise generator chip approved by the China's State Cryptography Administration (SCA) to offer information security for network applications.
Working in conjunction with a network data encryption interface card, the network data encryption service processing unit can use the SM2, SM3, SM4, random number generation, and non-SM algorithms to encrypt and decrypt network data of the application system. Working without a network data encryption interface card, it can use non-SM algorithms to encrypt and decrypt the network data of the application system.
Specifications
The figures in this section are for illustration only.
IM-SFMX
Front panel
Figure 2 IM-SFMX front panel
(1) Status LED (see Table 2 for the LED description) |
Technical specifications
Item |
Specifications |
Dimensions (H × W × D) |
40 × 399 × 355 mm (1.57 × 15.71 × 13.98 in) |
Power consumption |
90 W to 165 W |
Subslot |
1 |
Applicable system software versions |
8210 or later |
MIC-SM
The MIC-SM network data encryption interface card is not hot swappable.
The MIC-SM must be installed on an IM-SFMX for use. It occupies one subcard slot.
The MIC-SM has two USB ports: KEY (reserved for future use) and AUTH. It is provided with six USB keys for you to obtain user roles to manage the card. To obtain a user role, first insert a USB key into USB port AUTH. For more information about the network data encryption card configuration, see encryption-card user management in H3C CR16000-F Router Security Configuration Guide.
Figure 3 MIC-SM
Front panel
Figure 4 MIC-SM front panel
(1) Status LED (see Table 2 for the LED description) |
(2) USB port KEY (reserved) |
(3) USB port AUTH |
Technical specifications
Item |
Specifications |
Dimensions (H × W × D) |
37 × 179 × 149 mm (1.46 × 7.05 × 5.87 in) |
Power consumption |
20 W to 40 W |
Ports |
· USB port KEY (reserved for future use) · USB port AUTH |
Number of USB keys |
6 |
LEDs
Table 2 Status LED description
LED mark |
Status |
Description |
RUN (green) |
Steady on |
The module is faulty. |
Off |
The module is faulty or not installed. |
|
Slow flashing (1 Hz) |
The module is operating correctly. |
|
Fast flashing |
The module is starting up. If the LED keeps fast flashing, module registration has failed. |
Environment requirements
Make sure the ambient environment meets the following requirements:
· Temperature and humidity requirements
Table 3 Temperature and humidity requirements
Item |
Specifications |
Operating temperature |
0°C to 45°C (32°F to 113°F) |
Storage temperature |
–40°C to +70°C (–40°F to +158°F) |
Operating humidity |
10% RH to 95% RH, non-condensing |
Storage humidity |
5% RH to 95% RH, non-condensing |
· Dust protection requirements
Table 4 Dust concentration limits in the equipment room
Substance |
Particle diameter |
Concentration limit |
Dust particles |
≥ 0.5 µm |
≤ 1.8 × 107 particles/m3 |
· Corrosive gas protection requirements
Table 5 Corrosive gas concentration limits in the equipment room
Gas |
Average concentration (mg/m3) |
Maximum concentration (mg/m3) |
SO2 |
0.3 |
1.0 |
H2S |
0.1 |
0.5 |
Cl2 |
0.1 |
0.3 |
HCI |
0.1 |
0.5 |
HF |
0.01 |
0.03 |
NH3 |
1.0 |
3.0 |
O3 |
0.05 |
0.1 |
NOX |
0.5 |
1.0 |