Country / Region
Country / Region
H3C S9850-G high-density intelligent switch series is developed for data centers and cloud computing networks. It provides powerful hardware forwarding capacity and abundant data center features. It provides high density ports and 1 out-of-band management port (one copper port). The 100G ports are 100G/40G autosensing and each can be split into four interfaces. The switch supports modular power supplies and fan trays. By using different fan trays, the switch can provide field-changeable airflows.
The switch is an ideal product for high-density 100GE accessing and aggregation at data centers and cloud computing networks. It can also operate as a TOR access switch on an overlay or integrated network.
The S9850-G switch series includes one model:
S9850-32H-G: The switch provides 32×100GE QSFP28 ports or 16×100GE QSFP28 and 4×400G QSFP-DD, 5×fan tray slots, supports 1+1 power module redundancy.
The following contents are complex, and it is recommended to browse on PC.
Enter c.h3c.com.cn on the PC browser and operate according to the page to synchronize to the PC and continue browsing.
Continue by mobile
The switch offers high-density 100G/400G ports and a forwarding capacity as high as 6.4Tbps, which enables the switch to provide high-density server access in high-end data centers without oversubscriptions.
H3C S9850-G switch series adopt industry-leading programmable chips, which can define forwarding logic according to user requirements. Users can develop new features that meet the evolving trend of their networks through simple software updates.
With the rapid development of data center, the scale of the data center expands rapidly, reliability, operation and maintenance become the bottleneck of data center for further expansion. H3C S9850-G switch series conform to the trend of automated data operation and maintenance, and support visualization of data center. H3C S9850-G switch series can send real-time resources information, statistics, and alarm of RDMA information to the data center operation and maintenance platform through ERSPAN and GRPC protocols. This can allow the operation and maintenance center to perform real-time analysis in order to achieve network quality tracing, troubleshooting, risk warning and system optimization, etc. Visualization can even adjust network configuration automatically and reduce network congestion, which makes it possible to move to automated data center operation and maintenance.
H3C S9850-G switch series adopt the next-generation chip with more flexible OpenFlow Flow Table, more resources and accurate ACL matching, which greatly improves the software-defined network (SDN) capabilities and meet the demand of data center SDN network.
H3C S9850-G switch series support standard OpenFlow protocol, which can be integrated and managed by H3C or mainstream cloud platforms to support flexible network customization and automated management. Users and third-party controllers can use standard interfaces to develop and deploy a dedicated network management strategy for rapid business deployment, functional expansion, and intelligent device management.
The switch supports abundant data center features, including:
FCoE: Allows transmission of FC packets over Ethernet so that FC SAN services and LAN services can run over the same network infrastructure.
PFC, ECN, and DCBX: Helps provide FC storage and high-performance computing services with low-latency and no data loss.
VXLAN: Supports VXLAN (Virtual Extensible LAN), which provides two major benefits, higher scalability of Layer 2 segmentation and better utilization of available network paths.
DCB, RoCE, and OAM: Provides high-performance services.
To cope with data center cooling aisle design, the H3C S9850-G switch series comes with flexible airflow design, which features bi-cooling aisles in the front and back. Users may also choose the direction of airflow (from front to back or vice versa) by selecting a different fan tray.
The switch improves system management through the following ways:
Provides multiple management interfaces, including the serial console port, USB port, one out-of-band management port.
Supports configuration and management from CLI or a mainstream network management platform and H3C IMC Intelligent Management Center.
Supports multiple access methods, including SNMPv1/v2c/v3, Telnet, SSH 2.0, SSL, and FTP.
Supports GRPC and provides a flexible programmable interface for customized development.
Supports Telemetry, allowing for real-time, high-speed, and precise data collection.
H3C S9850-G switch series support M-LAG, which enables links of multiple switches to aggregate into one to implement device-level link backup. M-LAG is applicable to servers dual-homed to a pair of access devices for node redundancy.
Streamlined topology: M-LAG simplifies the network topology and spanning tree configuration by virtualizing two physical devices into one logical device.
Independent upgrading: The DR member devices can be upgraded independently one by one to minimize the impact on traffic forwarding.
High availability: The DR system uses a keepalive link to detect multi-active collision to ensure that only one member device forwards traffic after a DR system splits.
The S9850-G switch series provides multiple reliability protection at both switch and link levels. With over current, overvoltage, and overheat protection, all models have a redundant pluggable power module, which enables flexible configuration of AC power modules based on actual needs. The entire switch supports fault detection and alarm for power supply and fan, allowing fan speed to change to suit different ambient temperatures.
The switch supports diverse link redundancy technologies such as H3C proprietary RRPP, VRRP, and Smart Link. These technologies ensure quick network convergence even when large amount of traffic of multiple services runs on the network.
H3C S9850-G switch series support Layer 2 to Layer 4 packet filtering, which can provide traffic classification based on source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN.
Each 100G port provides a flexible queue scheduling algorithm, which can be set based on ports and queues at the same time.
S9850-G switch series supports five queuing modes include SP (Strict Priority), WRR (Weighted Round Robin), SP+WRR.
S9850-G switch series supports CAR (Committed Access Rate) function with a minimum granularity of 1Kbps, and port mirroring on both directions used to monitor packets on the specified port and forward the packets to the monitoring port for network detection and troubleshooting.
H3C S9850-G switch series supports AAA, RADIUS and user account-based authentication, IP, MAC, VLAN, port-based user identification, dynamic and static binding; when working with the H3C iMC platform, it can conduct real time management, instant diagnosis, and crackdown on illicit network behaviors
H3C S9850-G switch series supports enhanced ACL control logic, which enables an enormous amount of in-port and out-port ACL, and delegate VLAN based ACL. This simplifies user deployment process and avoids ACL resource wastage. S9850-G switch series can also take advantage of Unicast Reverse Path Forwarding (uRPF). When the device receives a packet, it will perform the reverse check to verify the source address from which the packets are supposedly originated and will drop the packet if such path doesn't exist.
MACsec is an ideal hop-by-hop link-layer security protocol for Ethernet networks, which are typically insecure. It provides the following services:
Data encryption: Encrypts data over the Ethernet link to protect data against security issues such as eavesdropping.
Anti-replay: Prevents packets from being intercepted and modified en route to protect the network against unauthorized access.
Tampering protection: prevents packet tampering to protect data integrity.
MACsec supports the following deployments:
Client-oriented: Protects data transmission over the link between the client and its access device.
Device-oriented mode: Protects data transmission over the link between two peering devices.
Item | S9850-32H-G |
Dimensions (H × W × D) | 43.6 × 440 × 400 mm (1.72 × 17.32 × 15.75 in) |
Weight (Full loaded) | ≤ 9kg |
CPU cores | 4 |
CPU frequency | 2.0GHz |
Buffer | 32M |
Flash/SDRAM | 2GB/4GB |
Serial console port | 1 × RF45 |
Out-of-band management port | 1 × 10/100/1000Base-T |
USB port | 1 |
QSFP28 port | 32 |
QSFP-DD port | 4(Maximum) |
AC-input voltage | 90v to 264v |
DC-input voltage | –36v to –72v |
Power consumption (static) | Single AC: 81.54W Single DC: 82.56W Dual AC: 92.53W Dual DC: 90.28W |
Power consumption (at full load) | Single AC: 390.5W Single DC: 410.1W Dual AC: 386.3W Dual DC: 404.2W |
Power module slot | 2 |
Fan tray slot | 5 |
Air flow direction | From front to rear or from rear to front |
Operating temperature | -5~45℃ |
Operating humidity | 5%~95% |
Switching capacity | 6.4Tbps |
Forwarding capacity | 2024Mpps |
Item | S9850-32H-G |
Forwarding mode | Store-forward and cut-through modes |
Virtualization | Distributed device management, distributed link aggregation, and distributed resilient routing |
Link aggregation | 40GE/100GE port aggregation |
Data center | VXLAN RESTCONF YANG |
MAC address table | Static MAC address |
VLAN | Port-based VLAN |
Traffic monitoring | sFlow |
DHCP | DHCP server/client |
ARP | Gratuitous ARP |
IP routing | Stating routing, RIPv1/v2, OSPFv1/v2/v3, BGP, IS-IS |
IPV6 | IPv6 ND |
Multicast | IGMP snooping v2/v3 |
Zero-configuration | Auto-config |
MPLS | MPLS L3VPN VRF/VRF-Lite |
MSTP | STP/RSTP/MSTP |
QoS/ACL | Inbound and outbound traffic rate limit |
IEEE Standard | 802.3x |
Mirroring | Traffic mirroring |
Security | Secure Boot Trusted Platform Module Hierarchical user management and password protection Micro-Segmentation AAA/RADIUS/HWTACACS |
LACP | LACP |
Link layer | LLDP |
Loading and upgrading | Loading/upgrading through the XMODEM protocol |
Loading/upgrading through FTP and TFTP | |
Management and maintenance | Configuration via CLI, Telnet, and Console port |
EMC | FCC Part 15 Subpart B CLASS A |
Safety | UL 60950-1 |
Item | S9850-32H-G |
ARP entries | 78K max |
IPv4 routing entries | 768K max |
IPv6 unicast routing entries | 64K max |
MAC address entries | 288K max |
Jumbo frame length | 13312 Bytes |
Product ID | Product Description |
LS-9850-32H-G | H3C S9850-32H-G L3 Ethernet Switch with 16*QSFP28 Ports and 16*QSFP28 Ports or 4*QSFP-DD Ports, Without Power Supplies |
PSR450-12A1 | 450W AC Power Supply Module (Power Panel Side Exhaust Airflow) |
PSR450-12A | 450W AC Power Supply Module (Power Panel Side Intake Airflow) |
PSR450-12D | 450W DC Power Supply Module (Power Panel Side Exhaust Airflow) |
LSPM1FANSA-SN | H3C Fan Module (Fan Panel Side Intake Airflow) |
LSPM1FANSB-SN | H3C Fan Module (Fan Panel Side Exhaust Airflow) |
QSFP-100G-D-AOC-10M | 100G QSFP28 to 100G QSFP28 10m Active Optical Cable |
QSFP-100G-D-CAB-1M | 100G QSFP28 to 100G QSFP28 1m Passive Cable |
QSFP-100G-D-AOC-20M | 100G QSFP28 to 100G QSFP28 20m Active Optical Cable |
QSFP-100G-D-CAB-3M | 100G QSFP28 to 100G QSFP28 3m Passive Cable |
QSFP-100G-D-AOC-7M | 100G QSFP28 to 100G QSFP28 7m Active Optical Cable |
QSFP-100G-4SFP-25G-CAB-1M | 100G QSFP28 to 4x25G SFP28 1m Passive Cable |
QSFP-100G-4SFP-25G-CAB-3M | 100G QSFP28 to 4x25G SFP28 3m Passive Cable |
QSFP-100G-4SFP-25G-CAB-5M | 100G QSFP28 to 4x25G SFP28 5m Passive Cable |
QSFP-100G-LR4-WDM1300 | 100G QSFP28 Optical Transceiver Module(1310nm,10km,LR4,WDM,LC) |
QSFP-100G-LR4L-WDM1300 | 100G QSFP28 Optical Transceiver Module (1310nm,2km,LR4L,CWDM4,LC) |
QSFP-100G-ER4L-WDM1300 | 100G QSFP28 Optical Transceiver Module (1310nm,40km,ER4L,WDM,LC) |
QSFP-100G-PSM4-SM1310 | 100G QSFP28 Optical Transceiver Module (1310nm,500m,PSM4,MPO/APC) |
QSFP-100G-SR4-MM850 | 100G QSFP28 Optical Transceiver Module (850nm,100m OM4,SR4,MPO) |
QSFP-40G-LR4-WDM1300 | QSFP+ 40GBASE Optical Transceiver Module (1310nm,10km,LR4,LC) |
QSFP-40G-BIDI-SR-MM850 | QSFP+ 40GBASE BIDI Optical Transceiver Module (850nm,100m,SR) |
QSFP-40G-LR4L-WDM1300 | QSFP+ 40GBASE Optical Transceiver Module (1310nm,2km,LR4L,LC) |
QSFP-40G-ER4-WDM1300 | QSFP+ 40GBASE Optical Transceiver Module (1310nm,40km,ER4,LC) |
QSFP-40G-SR4-MM850 | QSFP+ 40GBASE Optical Transceiver Module (850nm,100m,SR4,Support 40G to 4*10G) |
QSFP-40G-CSR4-MM850 | QSFP+ 40GBASE Optical Transceiver Module (850nm,300m,CSR4,Support 40G to 4*10G) |
QSFPDD-400G-SR8-MM850 | 400G QSFPDD Optical Transceiver Module(850nm,100m OM4,SR8,MPO16/APC) |