01-Text

Download

Table of Contents

Chapter 1 Product Overview.. 1-1

1.1 Overview. 1-1

1.2 S5600-26C/S5600-26C-PWR/S5600-26F Ethernet Switch. 1-2

1.2.1 Front Panel 1-2

1.2.2 Rear Panel 1-10

1.3 S5600-50C/S5600-50C-PWR Ethernet Switch. 1-11

1.3.1 Front Panel 1-11

1.3.2 Rear panel 1-12

1.4 Power system.. 1-13

1.5 Cooling system.. 1-13

1.6 Attributes of 1000 Mbps SFP port 1-14

1.7 Expansion Module. 1-15

1.8 S5600 Series Technical Specifications. 1-18

Chapter 2 Preparing for Installation. 2-1

2.1 Safety Precautions. 2-1

2.2 Installation Site. 2-1

2.2.1 Temperature/Humidity. 2-1

2.2.2 Cleanness. 2-2

2.2.3 Electromagnetic Susceptibility. 2-2

2.2.4 Laser Safety. 2-3

2.3 Installation Tools. 2-3

Chapter 3 Installing the Switch. 3-1

3.1 Rack-Mounting the Switch. 3-1

3.1.1 Introduction to mounting ear 3-1

3.1.2 Introduction to guide rail 3-2

3.1.3 Use front mounting ears and a tray. 3-3

3.1.4 Use front and rear mounting ears. 3-4

3.1.5 Use front mounting ears and guide rails. 3-7

3.2 Mounting the Switch on a Tabletop/Workbench. 3-9

3.3 Installing/Removing the Power Module. 3-10

3.3.1 Installing the Power Module. 3-10

3.3.2 Removing the Power Module. 3-10

3.4 Connecting the Power Cord and the Ground Wire. 3-11

3.4.1 Connecting the AC-Input Power Cord. 3-11

3.4.2 Connecting the DC-Input Power Cord. 3-12

3.4.3 Connecting the Ground Wire. 3-13

3.5 Connecting the Switch to a Console Terminal 3-16

3.5.1 Console Cable. 3-16

3.5.2 Connecting the Console Cable. 3-16

3.6 Installing/Removing the Stack Cable. 3-17

3.6.1 Stack Cable. 3-17

3.6.2 Installing the Stack Cable. 3-17

3.6.3 Removing the Stack Cable. 3-18

3.7 Installing/Removing the Optional Interface Module. 3-18

3.8 Verifying Installation. 3-19

Chapter 4 Starting up the Switch at the Initial Boot 4-1

4.1 Setting up a Configuration Environment 4-1

4.2 Connecting the Console Cable. 4-1

4.3 Setting Terminal Parameters. 4-1

4.4 Booting the Switch. 4-4

4.4.1 Verifying Installation before Power-up. 4-4

4.4.2 Powering up the Switch. 4-4

Chapter 5 Loading Boot ROM and Host Software. 5-1

5.1 Introduction to Loading Approaches. 5-1

5.2 Loading Software Locally. 5-1

5.2.1 Boot Menu. 5-1

5.2.2 Loading Software from Console Port Using XModem.. 5-3

5.2.3 Loading Software from an Ethernet Port Using TFTP. 5-7

5.2.4 Loading Software from an Ethernet Port Using FTP. 5-9

5.3 Loading Software Remotely. 5-10

5.3.1 Loading Software Remotely Using FTP. 5-10

5.3.2 Loading Software Remotely Using TFTP. 5-11

Chapter 6 Maintenance and Troubleshooting. 6-1

6.1 Dealing with Loading Failures. 6-1

6.2 Dealing with Password Loss. 6-1

6.3 Dealing with Power System Failures. 6-1

6.4 Dealing with Configuration System Failures. 6-1

 


Chapter 1  Product Overview

1.1  Overview

H3C S5600 Series Ethernet Switches are high-performance, high-density, easy-to-install, NMS-manageable intelligent Ethernet switches which support wire-speed Layer2/3 switching.

Table 1-1 lists the models of H3C S5600 Series Ethernet Switches.

Table 1-1 Models of H3C S5600 Series Ethernet Switches

Model

Number of 10/100/1000M electrical ports

Number of 1000M SFP optical ports

Number of Console ports

S5600-26C

24

4

1

S5600-26C-PWR

S5600-26F

4

24

S5600-50C

48

4

S5600-50C-PWR

 

Each SFP port and the corresponding 10/100/1000M Ethernet port form a Combo port. For each Combo port, the SFP port and the 10/100/1000M Ethernet port cannot be used at the same time. For the relationship between the Combo ports and the Ethernet ports, refer to Table 1-2.

Table 1-2 Combo port list

Switch model

Combo Port

Corresponding port

S5600-26C/S5600-26C-PWR/S5600-26F

25

22

26

24

27

21

28

23

S5600-50C/S5600-50C-PWR

49

46

50

48

51

45

52

47

 

&  Note:

l      The electrical ports of S5600-26C-PWR/S5600-50C-PWR are capable of supplying -48 VDC power to remote PDs (powered devices, such as S2016C, S2008B, S2016B, S2016-EI, and so on).

l      The S5600-26C-PWR/S5600-50C-PWR adopts PoE power module, which provides AC/DC power to PD devices. When delivering the AC input, the module can supply up to 300 W power. If more power is needed, use the DC input or both AC and DC inputs to ensure the operation of all the connected devices.

l      The S5600-26C-PWR/S5600-50C-PWR can also adopt AC/DC dual input power module. In this case, however, the two types of switches have no PoE function. And they function exactly like the S5600-26C and S5600-50C.

 

1.2  S5600-26C/S5600-26C-PWR/S5600-26F Ethernet Switch

1.2.1  Front Panel

I. Front panel

The S5600-26C/S5600-26C-PWR provides 24 x 10/100/1000Base-TX Ethernet ports, one Console port, and four 1000 Mbps SFP Combo ports on its front panel. Each SFP port and the corresponding 10/100/1000M Ethernet port form a Combo port. For each Combo port, the SFP port and the 10/100/1000M Ethernet port cannot be used at the same time. For the relationship between the Combo ports and the Ethernet ports, refer to Table 1-2.

 Figure 1-1 shows the front panel of an S5600-26C Ethernet switch.:

(1) 10/100/1000M auto-negotiation Ethernet port status LEDs

(2) 1000 Mbps SFP Combo port LED

(3) Console port

(4) 7-segment digitron display

(5) Power LED

(6) DC LED

(7) Fabric LED

(8) Module LED

(9) Port mode LED

(10) Mode button

 

Figure 1-1 Front panel of the S5600-26C/S5600-26C-PWR

The S5600-26F provides 24 x 1000 Mbps SFP optical ports, one Console port, and four 1000 Mbps RJ-45 Combo ports on its front panel. Each SFP port and the corresponding 10/100/1000M Ethernet port form a Combo port. For each Combo port, the SFP port and the 10/100/1000M Ethernet port cannot be used at the same time. For the relationship between the Combo ports and the Ethernet ports, refer to Table 1-2.

Figure 1-2. shows the front panel of an S5600-26F Ethernet switch.:

(1) SFP optical port status LED

(2) 10/100/1000M auto-negotiation Ethernet port status LEDs: left one for speed, right one for duplex mode

(3) Console port

(4) 7-segment digitron display

(5) Power LED

(6) RPS LED

(7) Fabric LED

(8) Module LED

Figure 1-2 Front panel of the S5600-26F

II. LEDs

The S5600-26C/S5600-26C-PWR provides one power LED, one RPS LED, one fabric LED, one module LED, one mode LED, one 7-segment digitron display, four pairs of 1000 Mbps SFP port status LEDs, and 24 pairs of 10/100/1000M port status LEDs on its front panel.

The S5600-26F provides one power LED, one RPS LED, one fabric LED, one module LED, one 7-segment digitron display, 24 pairs of 1000 Mbps SFP port status LEDs, and four pairs of 10/100/1000M auto-negotiation Ethernet port status LEDs on its front panel.

Table 1-3 and Table 1-4 describe respectively the LEDs on the S5600-26C/S5600-26C-PWR and S5600-26F.

Table 1-3 LEDs on the S5600-26C/S5600-26C-PWR

LED

Mark

Status

Description

Mode LED

Mode

Speed

Solid green

The port status LEDs are showing the speed of each port.

Duplex

Solid yellow

The port LEDs are showing the duplex mode of each port.

PoE

Blinking green (at 1 Hz)

The port LEDs are showing the PoE status of each port.

Power LED

PWR

Solid green

The switch is started normally.

Blinking green (at 1 Hz)

The system is running power-on self-test (POST).

Solid red

The system fails the POST, or there is another fault.

Blinking yellow (at 1 Hz)

Some ports fail the POST and do not function.

OFF

The switch is power-off.

DC LED

RPS

Solid green

Both the AC power supply and the DC input operate normally.

Solid yellow

The AC power supply fails or the AC input is disconnected, while the DC input operates normally.

OFF

DC input is disconnected.

Fabric LED

STK

Green

The device is in the ring fabric status; the LED blinks quickly when the fabric port is receiving or sending data.

Yellow

The device is in the daisy chain fabric status; the LED blinks quickly when the fabric port is receiving or sending data.

Blinking green (at 3 Hz)

This device is isolated from the whole set of fabric devices (effective when this device is in the fabric status).

OFF

Neither of the two fabric ports is connected.

Module LED

Module (MOD)

Solid green

The module is seated and operates normally.

Blinking yellow

The module fails or is not supported.

OFF

No module is installed.

7-segment digitron display

Unit

POST running

Blinking green

The POST ID of the in-process test is displayed:

POST failed

Blinking red

The POST ID of the failed test blinks.

Software downloading

Blinking green

A light bar rotates clockwise around the display during the downloading procedure.

Fan failed

Solid red

An “F” is displayed.

Over temperature alarm

Solid red

A “t” is displayed.

Speed and duplex mode

Solid green

UNIT ID in the fabric; or “1” for a standalone unit is displayed.

PoE mode

Solid green

The utilization of the power supply is displayed.

10/100/ 1000M auto- negotiation Ethernet port status LED

Speed mode

Green

The port is operating at 1000 Mbps. The LED blinks quickly when the port is receiving or sending data.

Yellow

The port is operating at 10/100 Mbps. The LED blinks quickly when the port is receiving or sending data.

Blinking yellow (at 3 Hz)

The port fails the POST.

OFF

The port is not connected.

Duplex mode

Green

The port is operating in full duplex mode. The LED blinks quickly when the port is receiving or sending data.

Yellow

The port is operating in half duplex mode. The LED blinks quickly when the port is receiving or sending data.

Blinking Yellow (3 Hz)

The port fails the POST.

OFF

The port is not connected.

PoE mode

Solid green

The port supplies power normally.

Blinking green (at 1 Hz)

The connected device requires more power than the maximum power a port can supply.

The port cannot supply power because the switch has reached its maximum power supplied.

Solid yellow

The port cannot supply power because the connected device is not a PD.

The port cannot supply power due to the power source failure of PoE.

Blinking yellow (3 Hz)

The port fails the POST.

OFF

The port does not supply power.

1000M Base SFP port mode LED

Speed mode

Green

The port is operating at 1000 Mbps. The LED blinks quickly when the port is receiving or sending data.

Blinking yellow (3 Hz)

The port fails the POST.

OFF

The port is not connected.

Duplex mode

Green

The port is operating in 1000 Mbps full duplex mode. The LED blinks quickly when the port is receiving or sending data.

Blinking yellow (3 Hz)

The port fails the POST.

OFF

The port is not connected.

PoE mode

OFF

 

Table 1-4 LEDs on the S5600-26F

LED

Mark

Status

Description

Power LED

PWR

Solid green

The switch is started normally.

Blinking green (at 1 Hz)

The system is running power-on self-test (POST).

Solid red

The system fails the POST, or there is another fault.

Blinking yellow (at 1 Hz)

Some ports fail the POST and do not function.

OFF

The switch is power-off.

DC LED

RPS

Solid green

Both the AC power supply and the DC input operate normally.

Solid yellow

The AC power supply fails or the AC input is disconnected, while the DC input operates normally.

OFF

DC input is disconnected.

Fabric LED

STK

Green

The device is in the ring fabric status; the LED blinks quickly when the fabric port is receiving or sending data.

Yellow

The device is in the daisy chain fabric status; the LED blinks quickly when the fabric port is receiving or sending data.

Blinking green (at 3 Hz)

This device is isolated from the whole set of fabric devices (effective when this device is in the fabric status).

OFF

Neither of the two fabric ports is connected.

Module LED

Module (MOD)

Solid green

The module is seated and operates normally.

Blinking yellow

The module fails or is not supported.

OFF

No module is installed.

7-segment digitron display

Unit

POST running

Blinking green

The POST ID of the in-process test is displayed:

POST failed

Blinking red

The POST ID of the failed test blinks.

Software downloading

Blinking green

A light bar rotates clockwise around the display during the downloading procedure.

Fan failed

Solid red

An “F” is displayed.

Over temperature alarm

Solid red

A “t” is displayed.

Speed and duplex mode

Solid green

UNIT ID in the fabric; or “1” for a standalone unit is displayed.

10/100/ 1000M auto- negotiation Ethernet port status LED

Speed mode

Green

The port is operating at 1000 Mbps. The LED blinks quickly when the port is receiving or sending data.

Yellow

The port is operating at 10/100 Mbps. The LED blinks quickly when the port is receiving or sending data.

Blinking yellow (at 3 Hz)

The port fails the POST.

OFF

The port is not connected.

Duplex mode

Green

The port is operating in full duplex mode. The LED blinks quickly when the port is receiving or sending data.

Yellow

The port is operating in half duplex mode. The LED blinks quickly when the port is receiving or sending data.

Blinking Yellow (3 Hz)

The port fails the POST.

OFF

The port is not connected.

1000Base SFP optical port status LED

port status LED

Green

The port is operating at 1000 Mbps. The LED blinks quickly when the port is receiving or sending data.

Blinking yellow (3 Hz)

The port fails the POST.

OFF

The port is not connected.

 

III. Console port

The S5600-26C/S5600-26C-PWR/S5600-26F provides an EIA/TIA-232-compliant Console port, which enables you to configure the switch from the local or remote site.

Table 1-5 Attributes of the Console port

Item

Description

Connector

RJ-45

Standard

EIA/TIA-232

Baud rate

9600 bps (default), auto-negotiation is supported

Services

Connection to an ASCII terminal

Connection to the serial port of a local terminal (a PC for example) or a remote terminal (through a pair of modems) running terminal emulation software

 

1.2.2  Rear Panel

I. Rear panel

 

&  Note:

The ports of the AC/DC dual input power module and the PoE power module are exactly the same, so only one rear panel illustration is shown below.

 

The S5600-26C/S5600-26C-PWR/S5600-26F provides two sockets for pluggable power module, two fabric ports, one expansion slot, and one grounding screw on its rear panel, as shown in the following figure.

(1) AC-input power socket for the power module

(2) Expansion module

(3) Grounding screw

(4) Fabric ports

(5) Fabric port LEDs

(6) RPS LED

(7) DC-input power socket for the power module

 

Figure 1-3 Rear panel of the S5600-26C/S5600-26C-PWR/S5600-26F

II. Fabric port

The fabric port marked with “UP” connects to a port of the same type on an upstream device; the fabric port marked with “DOWN” connects to a port of the same type on a downstream device.

Table 1-6 Fabric port LEDs

LED

Mark

Status

Indicate

Fabric port LED

UP(DOWN)

Solid green

The fabric port is properly connected.