01-Text

Download

Table of Contents

Chapter 1 Product Overview.. 1-1

1.1 Introduction. 1-1

1.2 S3600-28P-SI 1-3

1.2.1 Front Panel 1-3

1.2.2 Rear Panel 1-7

1.3 S3600-28TP-SI 1-8

1.3.1 Front Panel 1-8

1.3.2 Rear Panel 1-12

1.4 S3600-52P-SI 1-13

1.4.1 Front Panel 1-13

1.4.2 Rear Panel 1-14

1.5 S3600-28P-EI 1-15

1.5.1 Front Panel 1-15

1.5.2 Rear Panel 1-19

1.6 S3600-28F-EI 1-19

1.6.1 Front Panel 1-19

1.6.2 Rear Panel 1-25

1.7 S3600-52P-EI 1-26

1.7.1 Front Panel 1-26

1.7.2 Rear Panel 1-27

1.8 S3600-28P-PWR-SI/S3600-28P-PWR-EI 1-28

1.8.1 Front Panel 1-28

1.8.2 Rear Panel 1-34

1.9 S3600-52P-PWR-SI/S3600-52P-PWR-EI 1-34

1.9.1 Front Panel 1-34

1.9.2 Rear Panel 1-36

1.10 Features of the S3600 Series. 1-37

1.10.1 Features of the S3600-SI 1-37

1.10.2 Features of the S3600-EI 1-38

1.10.3 Features of the S3600-PWR-SI/S3600-PWR-EI 1-39

Chapter 2 Preparation. 2-1

2.1 Safety Precautions. 2-1

2.2 Installation Site. 2-1

2.2.1 Temperature/Humidity. 2-1

2.2.2 Cleanness. 2-2

2.2.3 Electromagnetic Susceptibility. 2-2

2.2.4 Laser Safety. 2-3

2.3 Installation Tools. 2-3

Chapter 3 Installation. 3-1

3.1 Mounting the Switch. 3-1

3.1.1 Mounting the Switch into a 19-Inch Standard Cabinet 3-1

3.1.2 Mounting the Switch on a Desktop/Workbench. 3-10

3.2 Connecting the Power Cord and the Ground Wire. 3-10

3.2.1 Connecting the AC Power Cord. 3-10

3.2.2 Connecting the DC-Input Power Cord. 3-11

3.2.3 Connecting the Ground Wire. 3-13

3.2.4 Multi-power Input 3-15

3.3 Connecting Optical Fiber 3-15

3.4 Connecting the Switch to a Console Terminal 3-16

3.4.1 Console Cable. 3-16

3.4.2 Connecting the Console Cable. 3-16

3.5 Connecting and Removing Special Stack Interconnect Cables. 3-17

3.5.1 Special Stack Interconnect Cables. 3-17

3.5.2 Connecting Special Stack Interconnect Cables. 3-17

3.5.3 Removing Special Stack Interconnect Cables. 3-18

3.6 Verifying Installation. 3-18

Chapter 4 Starting up the Switch at the Initial Boot 4-1

4.1 Setting up a Configuration Environment 4-1

4.2 Connecting the Console Cable. 4-1

4.3 Setting Terminal Parameters. 4-1

4.4 Booting the Switch. 4-4

4.4.1 Verifying Installation before Power-up. 4-4

4.4.2 Powering up the Switch. 4-4

Chapter 5 Loading Boot ROM and Host Software. 5-1

5.1 Introduction to Loading Approaches. 5-1

5.2 File attribute in Boot ROM.. 5-1

5.2.1 Introduction to File Attribute. 5-1

5.2.2 Impact of File Attributes on Downloading and Booting. 5-2

5.2.3 Setting the Attribute of a File. 5-3

5.3 Loading Software Locally. 5-5

5.3.1 Boot Menu. 5-5

5.3.2 Loading Software from Console Port Using XModem.. 5-6

5.3.3 Loading Software from an Ethernet Port Using TFTP. 5-11

5.3.4 Loading Software from an Ethernet Port Using FTP. 5-12

5.4 Loading Software Remotely. 5-13

5.4.1 Loading Software Remotely Using FTP. 5-14

5.4.2 Loading Software Remotely Using TFTP. 5-15

Chapter 6 Maintenance and Troubleshooting. 6-1

6.1 Dealing with Loading Failures. 6-1

6.2 Dealing with Password Loss. 6-1

6.2.1 Dealing with User Password Loss. 6-1

6.2.2 Recovering the Boot ROM Password. 6-2

6.3 Dealing with Power System Failures. 6-2

6.4 Dealing with Configuration System Failures. 6-2

 


Chapter 1  Product Overview

1.1  Introduction

H3C S3600 Series Ethernet Switches developed by H3C are high-performance, high-density, easy-to-install, NMS-manageable intelligent Ethernet switches which support wire-speed Layer 2/3 switching.

Table 1-1 lists the models of H3C S3600 Series Ethernet Switches.

Table 1-1 Models of the S3600 series

Subseries

Model

Power supply

Number of service ports

Number of 100 Mbps ports

Number of 1000 Mbps uplink ports

Number of Console ports

H3C S3600-SI

S3600-28P-SI

AC

28

24 × 10Base-T/100Base-TX Ethernet ports

4 × 1000Base-X SFP ports

1

S3600-28TP-SI

AC

28

24 × 10Base-T/100Base-TX Ethernet ports

2 × 1000Base-X SFP ports, 2 × 10/100/1000Base-T Ethernet ports

1

S3600-52P-SI

AC

52

48 × 10Base-T/100Base-TX Ethernet ports

4 × 1000Base-X SFP ports

1

H3C S3600-PWR-SI

S3600-28P-PWR-SI

AC/DC

28

24 × 10Base-T/100Base-TX Ethernet ports

4 × 1000Base-X SFP ports

1

S3600-52P-PWR-SI

AC/DC

52

48 × 10Base-T/100Base-TX Ethernet ports

4 × 1000Base-X SFP ports

1

H3C S3600-EI

S3600-28P-EI

AC/DC

28

24 × 10Base-T/100Base-TX Ethernet ports

4 × 1000Base-X SFP ports

1

S3600-28F-EI

AC/DC

28

24 x 100Base-X SFP ports

2 × 1000Base-X SFP ports, 2 × 10/100/1000Base-T Ethernet ports

1

S3600-52P-EI

AC/DC

52

48 × 10Base-T/100Base-TX Ethernet ports

4 × 1000Base-X SFP ports

1

H3C S3600-PWR-EI

S3600-28P-PWR-EI

AC/DC

28

24 × 10Base-T/100Base-TX Ethernet ports

4 × 1000Base-X SFP ports

1

S3600-52P-PWR-EI

AC/DC

52

48 × 10Base-T/100Base-TX Ethernet ports

4 × 1000Base-X SFP ports

1

 

&  Note:

l      The S3600-28P-PWR-SI, S3600-28P-PWR-EI, S3600-52P-PWR-SI, and S3600-52P-PWR-EI provides over-temperature protection mechanism. When the internal temperature exceeds 65°C (149°F), they will stop providing power from all ports. When the temperature is below 60°C (140°F), they will continue to provide power from all ports.

l      Only the recommended PoE power supply can be used for the S3600-28P-PWR-SI, S3600-28P-PWR-EI, S3600-52P-PWR-SI, and S3600-52P-PWR-EI. The –48 VDC from the equipment room cannot be used directly. Otherwise, devices may be damaged.

 

1.2  S3600-28P-SI

1.2.1  Front Panel

I. Schematic diagram

The S3600-28P-SI provides twenty-four 10Base-T/100Base-TX auto-sensing Ethernet ports, four 1000Base-X SFP ports, and one Console port on the front panel, as shown in Figure 1-1.

(1) 10Base-T/100Base-TX auto-sensing Ethernet port status LEDs

(2) 1000Base-X SFP port status LEDs

(3) AC power LED

(4) Mode LED

(5) Mode button

(6) 7-segment digital LED

(7) Console port

Figure 1-1 Front panel of the S3600-28P-SI

II. LEDs

The S3600-28P-SI provides one AC power LED, one mode LED, one 7-segment digital LED, twenty-four 10Base-T/100Base-TX auto-sensing Ethernet port status LEDs, and four 1000Base-X SFP port status LEDs on the front panel. You can learn how the switch operates by observing the LEDs listed in Table 1-2.

Table 1-2 LEDs on the front panel of the S3600-28P-SI

LED

Mark

Status

Indication

Mode LED

Mode

Speed

Solid green

Rate information of 10Base-T/100Base-TX auto-sensing Ethernet ports, and 1000Base-X SFP ports

Duplex

Solid yellow

Duplex information of 10Base-T/100Base-TX auto-sensing Ethernet ports, and 1000Base-X SFP ports

AC Power LED

PWR

Solid green

The switch is started normally.

Flashing green (1 Hz)

The system is running a power-on self-test (POST) or downloading software.

Solid red

The system fails a POST or a fault occurs.

Flashing yellow (1 Hz)

Some ports fail a POST or malfunctions occur.

OFF

The power is disconnected.

10Base-T/100 Base -TX port status LED

Speed

Green

ON

A 100 Mbps link is present.

Flashing

Data is being received/sent on the port.

Yellow

ON

A 10 Mbps link is present.

Flashing

Data is being received/sent on the port.

Flashing yellow (3 Hz)

The port fails the POST.

OFF

No link is present.

Duplex

Green

ON

The port is operating in full duplex mode.

Flashing

Data is being received/sent on the port.

Yellow

ON

The port is operating in half duplex mode.

Flashing

Data is being received/sent on the port.

Flashing yellow (3 Hz)

The port fails the POST.

OFF

No data is being received/sent on the port.

1000 Base-SFP port status LED

Speed

Green

ON

A 1000 Mbps link is present.

Flash

Data is being received/sent on the port.

Flashing yellow (3 Hz)

The port fails POST.

OFF

No link is present.

Duplex

Green

ON

The port is operating in full duplex mode.

Flash

Data is being received/sent on the port.

Flashing yellow (3 Hz)

 The port fails the POST.

OFF

The port is not connected.

PoE mode

Flashing green (3 Hz)

The port fails the POST.

OFF

––

Status LED of the 1000Base-X SFP port serving as a fabric port

Speed

Green

ON

The port is connected, and the device is in an IRF loop fabric.

Flashing

Data is being received/sent on the port.

Yellow

ON

The port is connected, and the device is in an IRF chain fabric.

Flash

Data is being received/sent on the port.

Flashing green (3Hz)

A fault occurs to Fabric.

Flashing yellow (3 Hz)

The port fails the POST.

OFF

The port is not connected.

Duplex

Green

ON

The port is in full duplex mode.

Flashing

Data is being received/sent on the port.

Flashing yellow (3 Hz)

The port fails the POST.

OFF

The port is not connected.

PoE

Flashing yellow (3 Hz)

The port fails the POST.

OFF

––

7-segment digital LED

Unit

POST running

The PWR LED flashes green

Displays the POST test ID (in the range of 1 to 9).

POST failed

The PWR LED flashes yellow

Flashes the POST test ID of the failed test.

The PWR LED is solid red

Software downloading

The PWR LED flashes green

A bar rotates clockwise around the LED.

Fan failed

The PWR LED is solid red

Displays “F”.

Unit ID

Button released

Displays the unit ID in the fabric; and displays “1” if there is only one unit.

 

III. Attributes of the 10Base-T/100Base-TX Ethernet ports

Table 1-3 Attributes of the 10Base-T/100Base-TX Ethernet Ports on the S3600-28P-SI

Attribute

Description

Connector

RJ-45

Number of ports

24

Rate

l      10 Mbps, half duplex/full duplex

l      100 Mbps, half-duplex/full duplex

l      MDI/MDI-X auto-sensing

Standard

IEEE 802.3u

Transmission distance over the selected medium

100 m (328.08 ft) over the category-5 unshielded twisted pair (UTP) cable

 

IV. Console port

The S3600-28P-SI provides one EIA/TIA-232 compliant Console port for local or remote configuration. Table 1-4 lists the attributes of the Console port.

Table 1-4  Console port attributes

Attribute

Description

Connector

RJ-45

Standard

Asynchronous EIA/TIA-232

Baud rate

9600 bps (default)

Service

l      Connection to the ASCII terminal

l      Connection to the serial interface of a local terminal (a PC for example) or to a remote terminal through a pair of modems), where terminal emulation program is run

 

V. Attributes of the 1000Base-X SFP ports

The S3600-28P-SI provides four 1000Base-X SFP ports (numbered from 25 to 28) on its front panel.

SFP modules allow for great flexibility because they are hot swappable and user configurable.

Table 1-5 lists the available SFP modules.

Table 1-5 1000Base-X SFP modules

Type

Model

SFP optical module

1000Base-X SFP module

SFP-GE-SX-MM850-A

SFP-GE-LX-SM1310-A

SFP-GE-LH40-SM1310

SFP-GE-LH40-SM1550

SFP-GE-LH70-SM1550

SFP electrical interface module

SFP-GE-T

 

&  Note:

l      The types of 1000Base-X SFP modules may be subject to changes without notice. Consult H3C marketing personnel or technical support personnel to obtain the latest information about SFP modules.

l      For specifications of SFP modules, refer to H3C Low End Series Ethernet Switches  Pluggable Modules Manual.

 

1.2.2  Rear Panel

I. Schematic diagram

The S3600-28P-SI provides an AC power socket and a grounding screw on its rear panel, as shown in Figure 1-2.

(1) AC power socket

(2) Grounding screw

Figure 1-2 Rear panel of the S3600-28P-SI

II. Power system

The following gives the input voltage specifications for the S3600-28P-SI:

Rated voltage range: 100 VAC to 240 VAC, 50/60 Hz

Input voltage range: 90 VAC to 264 VAC, 47 to 63 Hz

1.3  S3600-28TP-SI

1.3.1  Front Panel

I. Schematic diagram

The S3600-28TP-SI provides twenty-four 10Base-T/100Base-TX auto-sensing Ethernet ports, two 1000Base-X SFP ports, two 10/100/1000Base-T auto-sensing Ethernet ports, and one Console port on the front panel, as shown in Figure 1-3.

(1) 10Base-T/100Base-TX auto-sensing Ethernet port status LEDs

(2) 1000Base-X SFP port status LEDs

(3) 10/100/1000Base-T auto-sensing Ethernet port status LEDs

(4) Console port

 

(5) 7-segment digital LED

(6) AC power LED

(7) Mode LED

(8) Mode button

Figure 1-3 Front panel of the S3600-28TP-SI

II. LEDs

The S3600-28TP-SI provides one power LED, one DC power LED, one mode LED, one 7-segment digital LED, twenty-four 10Base-T/100Base-TX Ethernet port status LEDs, two 1000Base-X SFP port status LEDs, and two 10/100/1000Base-T auto-sensing Ethernet port status LEDs. You can learn how the switch operates by observing the LEDs listed in Table 1-6.

Table 1-6 LEDs on the front panel of the S3600-28TP-SI

LED

Mark

Status

Indication

AC power LED

PWR

Solid green

The switch is started normally.

Flashing green (1Hz)

The system is running a POST or downloading software.

Solid red

The system fails the POST or a fault occurs.

Flashing yellow (1Hz)

Some ports fail a POST or malfunctions occur.

OFF

The power is disconnected.

Mode LED

Mode

Speed

Solid green

Rate information of 10Base-T/100Base-TX Ethernet ports, and 1000Base-X SFP ports.

Duplex

Solid yellow

Duplex information of 10Base-T/100Base-TX Ethernet ports, and 1000Base-X SFP ports.

10Base-T/100Base-TX port status LED

Speed

Green

ON

A 100 Mbps link is present.

Flashing

Data is being received/sent on the port.

Yellow

On

A 10 Mbps link is present.

Flashing

Data is being received/sent on the port.

Flashing yellow (3Hz)

The port fails a POST.

OFF

No link is present.

Duplex

Green