H3C S3600 Series Ethernet Switches developed by H3C are high-performance,
high-density, easy-to-install, NMS-manageable intelligent Ethernet switches
which support wire-speed Layer 2/3 switching.
Table 1-1 lists the models of H3C S3600 Series Ethernet Switches.
Table 1-1 Models of the S3600 series
|
Subseries
|
Model
|
Power supply
|
Number of service ports
|
Number of 100 Mbps ports
|
Number of 1000 Mbps uplink ports
|
Number of Console ports
|
|
H3C S3600-SI
|
S3600-28P-SI
|
AC
|
28
|
24 × 10Base-T/100Base-TX Ethernet ports
|
4 × 1000Base-X SFP ports
|
1
|
|
S3600-28TP-SI
|
AC
|
28
|
24 × 10Base-T/100Base-TX Ethernet ports
|
2 × 1000Base-X SFP ports, 2 × 10/100/1000Base-T Ethernet ports
|
1
|
|
S3600-52P-SI
|
AC
|
52
|
48 × 10Base-T/100Base-TX Ethernet ports
|
4 × 1000Base-X SFP ports
|
1
|
|
H3C S3600-PWR-SI
|
S3600-28P-PWR-SI
|
AC/DC
|
28
|
24 × 10Base-T/100Base-TX Ethernet ports
|
4 × 1000Base-X SFP ports
|
1
|
|
S3600-52P-PWR-SI
|
AC/DC
|
52
|
48 × 10Base-T/100Base-TX Ethernet ports
|
4 × 1000Base-X SFP ports
|
1
|
|
H3C S3600-EI
|
S3600-28P-EI
|
AC/DC
|
28
|
24 × 10Base-T/100Base-TX Ethernet ports
|
4 × 1000Base-X SFP ports
|
1
|
|
S3600-28F-EI
|
AC/DC
|
28
|
24 x 100Base-X SFP ports
|
2 × 1000Base-X SFP ports, 2 × 10/100/1000Base-T Ethernet ports
|
1
|
|
S3600-52P-EI
|
AC/DC
|
52
|
48 × 10Base-T/100Base-TX Ethernet ports
|
4 × 1000Base-X SFP
ports
|
1
|
|
H3C S3600-PWR-EI
|
S3600-28P-PWR-EI
|
AC/DC
|
28
|
24 × 10Base-T/100Base-TX Ethernet ports
|
4 × 1000Base-X SFP
ports
|
1
|
|
S3600-52P-PWR-EI
|
AC/DC
|
52
|
48 × 10Base-T/100Base-TX Ethernet ports
|
4 × 1000Base-X SFP ports
|
1
|
l
The S3600-28P-PWR-SI, S3600-28P-PWR-EI, S3600-52P-PWR-SI,
and S3600-52P-PWR-EI provides over-temperature protection mechanism. When the
internal temperature exceeds 65°C (149°F), they will stop providing power from
all ports. When the temperature is below 60°C (140°F), they will continue to
provide power from all ports.
l
Only the recommended PoE power supply can be
used for the S3600-28P-PWR-SI, S3600-28P-PWR-EI, S3600-52P-PWR-SI, and S3600-52P-PWR-EI.
The –48 VDC from the equipment room cannot be used directly. Otherwise,
devices may be damaged.
1.2 S3600-28P-SI
I. Schematic diagram
The S3600-28P-SI provides twenty-four
10Base-T/100Base-TX auto-sensing Ethernet ports, four 1000Base-X SFP ports, and
one Console port on the front panel, as shown in Figure
1-1.

|
(1) 10Base-T/100Base-TX auto-sensing
Ethernet port status LEDs
|
|
(2) 1000Base-X SFP port status LEDs
|
(3) AC power LED
|
|
(4) Mode LED
|
(5) Mode button
|
|
(6) 7-segment digital LED
|
(7) Console port
|
Figure 1-1 Front panel of the S3600-28P-SI
II. LEDs
The S3600-28P-SI provides one AC power LED,
one mode LED, one 7-segment digital LED, twenty-four 10Base-T/100Base-TX
auto-sensing Ethernet port status LEDs, and four 1000Base-X SFP port status
LEDs on the front panel. You can learn how the switch operates by observing the
LEDs listed in Table 1-2.
Table 1-2 LEDs on the front panel of the
S3600-28P-SI
|
LED
|
Mark
|
Status
|
Indication
|
|
Mode LED
|
Mode
|
Speed
|
Solid green
|
Rate information of 10Base-T/100Base-TX
auto-sensing Ethernet ports, and 1000Base-X SFP ports
|
|
Duplex
|
Solid yellow
|
Duplex information of 10Base-T/100Base-TX
auto-sensing Ethernet ports, and 1000Base-X SFP ports
|
|
AC Power
LED
|
PWR
|
Solid green
|
The switch is started normally.
|
|
Flashing
green (1 Hz)
|
The system is running a power-on
self-test (POST) or downloading software.
|
|
Solid red
|
The system fails a POST or a fault
occurs.
|
|
Flashing
yellow (1 Hz)
|
Some ports fail a POST or malfunctions
occur.
|
|
OFF
|
The power is disconnected.
|
|
10Base-T/100 Base -TX port status LED
|
—
|
Speed
|
Green
|
ON
|
A 100 Mbps
link is present.
|
|
Flashing
|
Data is
being received/sent on the port.
|
|
Yellow
|
ON
|
A 10 Mbps
link is present.
|
|
Flashing
|
Data is
being received/sent on the port.
|
|
Flashing
yellow (3 Hz)
|
The port
fails the POST.
|
|
OFF
|
No link is
present.
|
|
Duplex
|
Green
|
ON
|
The port
is operating in full duplex mode.
|
|
Flashing
|
Data is
being received/sent on the port.
|
|
Yellow
|
ON
|
The port
is operating in half duplex mode.
|
|
Flashing
|
Data is
being received/sent on the port.
|
|
Flashing
yellow (3 Hz)
|
The port
fails the POST.
|
|
OFF
|
No data is
being received/sent on the port.
|
|
1000 Base-SFP
port status LED
|
—
|
Speed
|
Green
|
ON
|
A 1000
Mbps link is present.
|
|
Flash
|
Data is
being received/sent on the port.
|
|
Flashing
yellow (3 Hz)
|
The port
fails POST.
|
|
OFF
|
No link is
present.
|
|
Duplex
|
Green
|
ON
|
The port
is operating in full duplex mode.
|
|
Flash
|
Data is
being received/sent on the port.
|
|
Flashing
yellow (3 Hz)
|
The port
fails the POST.
|
|
OFF
|
The port
is not connected.
|
|
PoE mode
|
Flashing
green (3 Hz)
|
The port
fails the POST.
|
|
OFF
|
––
|
|
Status LED of the 1000Base-X SFP port serving
as a fabric port
|
—
|
Speed
|
Green
|
ON
|
The port is connected, and the device is
in an IRF loop fabric.
|
|
Flashing
|
Data is being received/sent on the port.
|
|
Yellow
|
ON
|
The port is connected, and the device is
in an IRF chain fabric.
|
|
Flash
|
Data is being received/sent on the port.
|
|
Flashing green (3Hz)
|
A fault occurs to Fabric.
|
|
Flashing yellow (3 Hz)
|
The port fails the POST.
|
|
OFF
|
The port is not connected.
|
|
Duplex
|
Green
|
ON
|
The port is in full duplex mode.
|
|
Flashing
|
Data is being received/sent on the port.
|
|
Flashing yellow (3 Hz)
|
The port fails the POST.
|
|
OFF
|
The port is not connected.
|
|
PoE
|
Flashing yellow (3 Hz)
|
The port fails the POST.
|
|
OFF
|
––
|
|
7-segment digital LED
|
Unit
|
POST running
|
The PWR LED flashes green
|
Displays the POST test ID (in the range
of 1 to 9).
|
|
POST failed
|
The PWR LED flashes yellow
|
Flashes the POST test ID of the failed
test.
|
|
The PWR LED is solid red
|
|
Software downloading
|
The PWR LED flashes green
|
A bar rotates clockwise around the LED.
|
|
Fan failed
|
The PWR LED is solid red
|
Displays “F”.
|
|
Unit ID
|
Button released
|
Displays the unit ID in the fabric; and
displays “1” if there is only one unit.
|
|
|
|
|
|
|
|
III. Attributes of the
10Base-T/100Base-TX Ethernet ports
Table 1-3 Attributes
of the 10Base-T/100Base-TX Ethernet Ports on the S3600-28P-SI
|
Attribute
|
Description
|
|
Connector
|
RJ-45
|
|
Number of ports
|
24
|
|
Rate
|
l
10 Mbps, half duplex/full duplex
l
100 Mbps, half-duplex/full duplex
l
MDI/MDI-X auto-sensing
|
|
Standard
|
IEEE 802.3u
|
|
Transmission distance over the selected
medium
|
100 m (328.08 ft) over the category-5
unshielded twisted pair (UTP) cable
|
IV. Console port
The S3600-28P-SI provides one EIA/TIA-232
compliant Console port for local or remote configuration. Table 1-4 lists the attributes of the Console port.
Table 1-4
Console
port attributes
|
Attribute
|
Description
|
|
Connector
|
RJ-45
|
|
Standard
|
Asynchronous EIA/TIA-232
|
|
Baud rate
|
9600 bps (default)
|
|
Service
|
l
Connection to the ASCII terminal
l
Connection to the serial interface of a local
terminal (a PC for example) or to a remote terminal through a pair of
modems), where terminal emulation program is run
|
V. Attributes of the 1000Base-X SFP
ports
The S3600-28P-SI provides four 1000Base-X SFP
ports (numbered from 25 to 28) on its front panel.
SFP modules allow for great flexibility
because they are hot swappable and user configurable.
Table 1-5 lists the available SFP modules.
Table 1-5 1000Base-X SFP modules
|
Type
|
Model
|
|
SFP
optical module
|
1000Base-X
SFP module
|
SFP-GE-SX-MM850-A
|
|
SFP-GE-LX-SM1310-A
|
|
SFP-GE-LH40-SM1310
|
|
SFP-GE-LH40-SM1550
|
|
SFP-GE-LH70-SM1550
|
|
SFP
electrical interface module
|
SFP-GE-T
|
l
The types of 1000Base-X SFP modules may be
subject to changes without notice. Consult H3C marketing personnel or technical
support personnel to obtain the latest information about SFP modules.
l
For specifications of SFP modules, refer to H3C
Low End Series Ethernet Switches Pluggable Modules Manual.
I. Schematic diagram
The S3600-28P-SI provides an AC power
socket and a grounding screw on its rear panel, as shown in Figure 1-2.

|
(1) AC power socket
|
(2) Grounding screw
|
Figure 1-2 Rear panel of the S3600-28P-SI
II. Power system
The following gives the input voltage
specifications for the S3600-28P-SI:
Rated voltage range: 100 VAC to 240 VAC, 50/60
Hz
Input voltage range: 90 VAC to 264 VAC, 47
to 63 Hz
I. Schematic diagram
The S3600-28TP-SI provides twenty-four
10Base-T/100Base-TX auto-sensing Ethernet ports, two 1000Base-X SFP ports, two 10/100/1000Base-T
auto-sensing Ethernet ports, and one Console port on the front panel, as shown
in Figure 1-3.

|
(1) 10Base-T/100Base-TX auto-sensing
Ethernet port status LEDs
|
|
(2) 1000Base-X SFP port status LEDs
|
|
(3) 10/100/1000Base-T auto-sensing
Ethernet port status LEDs
|
|
(4) Console port
|
|
|
(5) 7-segment digital LED
|
(6) AC power LED
|
|
(7) Mode LED
|
(8) Mode button
|
Figure 1-3
Front panel of the S3600-28TP-SI
II. LEDs
The S3600-28TP-SI provides one power LED,
one DC power LED, one mode LED, one 7-segment digital LED, twenty-four
10Base-T/100Base-TX Ethernet port status LEDs, two 1000Base-X SFP port status
LEDs, and two 10/100/1000Base-T auto-sensing Ethernet port status LEDs. You can
learn how the switch operates by observing the LEDs listed in Table 1-6.
Table 1-6 LEDs on the front panel of the S3600-28TP-SI
|
LED
|
Mark
|
Status
|
Indication
|
|
AC power
LED
|
PWR
|
Solid green
|
The switch is started normally.
|
|
Flashing green (1Hz)
|
The system is running a POST or
downloading software.
|
|
Solid red
|
The system fails the POST or a fault
occurs.
|
|
Flashing yellow (1Hz)
|
Some ports fail a POST or malfunctions
occur.
|
|
OFF
|
The power is disconnected.
|
|
Mode LED
|
Mode
|
Speed
|
Solid green
|
Rate information of 10Base-T/100Base-TX
Ethernet ports, and 1000Base-X SFP ports.
|
|
Duplex
|
Solid yellow
|
Duplex information of 10Base-T/100Base-TX
Ethernet ports, and 1000Base-X SFP ports.
|
|
10Base-T/100Base-TX port status LED
|
—
|
Speed
|
Green
|
ON
|
A 100 Mbps link is present.
|
|
Flashing
|
Data is being received/sent on the port.
|
|
Yellow
|
On
|
A 10 Mbps link is present.
|
|
Flashing
|
Data is being received/sent on the port.
|
|
Flashing yellow (3Hz)
|
The port fails a POST.
|
|
OFF
|
No link is present.
|
|
Duplex
|
Green
|
|