10-设备管理命令
本章节下载: 10-设备管理命令 (472.94 KB)
1.1.12 display cpu-usage configuration
1.1.13 display cpu-usage history
1.1.15 display device manuinfo
1.1.16 display device manuinfo chassis-only
1.1.17 display device manuinfo fan
1.1.18 display device manuinfo power
1.1.19 display diagnostic-information
1.1.23 display memory-threshold
1.1.26 display scheduler logfile
1.1.27 display scheduler reboot
1.1.28 display scheduler schedule
1.1.29 display switch-mode status
1.1.30 display system stable state
1.1.31 display system-working-mode
1.1.32 display transceiver alarm
1.1.33 display transceiver diagnosis
1.1.34 display transceiver interface
1.1.35 display transceiver manuinfo
1.1.37 display version-update-record
1.1.40 hardware-failure-detection
1.1.45 monitor cpu-usage enable
1.1.46 monitor cpu-usage interval
1.1.47 monitor cpu-usage threshold
1.1.48 monitor handshake-timeout disable-port
1.1.50 restore factory-default
1.1.51 reset scheduler logfile
1.1.53 reset version-update-record
1.1.62 switch-fabric removal-signal-suppression
clock datetime命令用来设置设备的UTC(Coordinated Universal Time,国际协调时间)时间。
设备的UTC时间为出厂时间。
time:设置的时间,格式为HH:MM:SS(小时:分钟:秒),HH取值范围为0~23,MM和SS取值范围为0~59。如果要设置成整分,则可以不输入秒;如果要设置成整点,则可以不输入分和秒。比如将time参数设置为0表示零点。
date:设置的日期,格式为MM/DD/YYYY(月/日/年)或者YYYY/MM/DD(年/月/日),MM的取值范围为1~12,DD的取值范围与月份有关,YYYY的取值范围为2000~2035。
为了保证与其它设备协调工作,为了更好的监控和维护设备,请确保设备的系统时间是准确的。设备的系统时间由UTC时间、本地时区和夏令时运算之后联合决定,通过display clock命令可以查看。
用户可使用本命令行配置UTC时间,或者通过NTP协议获取UTC时间,通过NTP协议获取的UTC时间比命令行配置的UTC时间更精确。
# 设置设备的UTC时间为2012年1月1日8时8分8秒。
<Sysname> clock datetime 8:8:8 1/1/2012
# 设置设备的UTC时间为2012年1月1日8时10分。
<Sysname> clock datetime 8:10 2012/1/1
clock protocol命令用来配置获取UTC时间的方式。
undo clock protocol命令用来恢复缺省情况。
clock protocol { none | ntp mdc mdc-id }
通过NTP协议获取UTC时间。
none:表示通过命令行配置UTC时间。
ntp:表示通过NTP(Network Time Protocol,网络时间协议)协议获取UTC时间。配置该参数后,用户不能通过命令行修改系统时间,需要配置NTP的相关参数才能获取到时钟。关于NTP的详细介绍和配置,请参见“网络管理和监控配置指导”中的“NTP”。
mdc mdc-id:表示时钟的来源MDC编号。
系统时间由UTC时间、本地时区和夏令时运算之后联合决定,通过display clock命令可以查看。
用户有以下方式获取UTC时间:
· 通过命令行配置UTC时间。
· 通过NTP协议获取UTC时间。
通过NTP协议获取的UTC时间比命令行配置的UTC时间更精确。
多次执行本命令,最后一次执行的命令生效。
所有MDC的系统时间相同。当设备从某个MDC获取时钟后,会同步给其它MDC。缺省情况下,从缺省MDC通过NTP协议获取UTC时间。
# 配置获取UTC时间的方式为通过命令行配置。
[Sysname] clock protocol none
clock summer-time命令用来设置夏令时。
undo clock summer-time命令用来恢复缺省情况。
clock summer-time name start-time start-date end-time end-date add-time
name:夏令时的名称,为1~32个字符的字符串,区分大小写。
start-time:开始时间,格式为HH:MM:SS,HH取值范围为0~23,MM和SS取值范围为0~59。如果要设置成整分,则可以不输入秒;如果要设置成整点,则可以不输入分和秒。
start-date:开始日期,有两种输入方式:
· 直接一次性输入月和日,参数格式为MM/DD,MM取值范围为1~12,DD的取值范围与月份有关。
· 分次输入月、日,各参数之间以<空格>键隔开。首先输入开始的月份,取值如下:January、February、March、April、May、June、July、August、September、October、November或December;然后输入开始的星期,用当月的第几个星期表示,取值如下:first、second、third、fourth、fifth或last;最后输入起始日,取值为Sunday、Monday、Tuesday、Wednesday、Thursday、Friday或Saturday。
end-time:结束时间,格式为HH:MM:SS,HH取值范围为0~23,MM和SS取值范围为0~59。如果要设置成整分,则可以不输入秒;如果要设置成整点,则可以不输入分和秒。
end-date:结束日期,有两种输入方式:
· 直接一次性输入月日,参数格式为MM/DD,MM取值范围为1~12,DD的取值范围与月份有关。
· 分次输入月、日,各参数之间以<空格>键隔开。首先输入开始的月份,取值如下:January、February、March、April、May、June、July、August、September、October、November或December;然后输入开始的星期,用当月的第几个星期表示,取值如下:first、second、third、fourth、fifth或last;最后输入起始日,取值为Sunday、Monday、Tuesday、Wednesday、Thursday、Friday或Saturday。
add-time:偏移时间,格式为HH:MM:SS,HH取值范围为0~23,MM和SS取值范围为0~59。如果要设置成整分,则可以不输入秒;如果要设置成整点,则可以不输入分和秒。
为了保证与其它设备协调工作,为了更好的监控和维护设备,请确保设备的系统时间是准确的。设备的系统时间由UTC时间、本地时区和夏令时运算之后联合决定,通过display clock命令可以查看。
请将所有网络设备的夏令时和当地夏令时保持一致。
# 设置夏令时PDT,从每年的8月1日的06:00:00开始,到9月1日的06:00:00结束,比当前设备标准时间增加1小时。
[Sysname] clock summer-time PDT 6 08/01 6 09/01 1
clock timezone命令用来配置系统所在的时区。
undo clock timezone命令用来恢复缺省情况。
clock timezone zone-name { add | minus } zone-offset
zone-name:时区名称,为1~32个字符的字符串,区分大小写。
add:在UTC时间的基础上增加指定时间。
minus:在UTC时间的基础上减少指定时间。
zone-offset:与UTC的时间差,格式为HH:MM:SS,HH取值范围为0~23,MM和SS取值范围为0~59,如果要设置成整分,则可以不输入秒;如果要设置成整点,则可以不输入分和秒。
为了保证与其它设备协调工作,为了更好的监控和维护设备,请确保设备的系统时间是准确的。设备的系统时间由UTC时间、本地时区和夏令时运算之后联合决定,通过display clock命令可以查看。
请将所有网络设备的时区和当地地理时区保持一致。
# 设置本地时区名称为Z5,比UTC标准时间增加5小时。
[Sysname] clock timezone Z5 add 5
command命令用来为Job分配命令。
undo command命令用来取消为Job分配的命令。
没有为Job分配命令。
Job视图
id:命令编号,取值范围为0~4294967295。该编号表示命令在Job中的执行顺序,编号小的命令优先执行。
command:为Job分配的命令。
多次输入command命令可以为当前Job分配多条命令,不同命令用编号来唯一区别。如果新分配命令的编号和已分配的某命令的编号相同,则新分配的命令会覆盖已分配的命令。
通过command分配的命令行必须是设备上可成功执行的命令行,不包括telnet、ftp、ssh2和monitor process。由用户保证配置的正确性,否则,命令行不能自动被执行。
如果需要分配的命令(假设为A)是非用户视图下的命令,则必须先分配进入A所在视图的命令(指定较小的id值),再分配A。比如:要使用Job定时执行shutdown命令,则需执行三次command命令,分别分配system-view、interface、shutdown命令,且各command命令的id值逐渐增大。
定时执行任务时,设备不会与用户交互信息。当需要用户交互确认时,系统将自动输入“Y”或“Yes”;当需要用户交互输入字符信息时,系统将自动输入缺省字符串,没有缺省字符串的将自动输入空字符串。
# 为Job(假设名称为backupconfig)分配命令,以便将配置文件startup.cfg备份到TFTP服务器192.168.100.11。
[Sysname] scheduler job backupconfig
[Sysname-job-backupconfig] command 2 tftp 192.168.100.11 put flash:/startup.cfg backup.cfg
# 为Job(假设名称为shutdownGE)分配命令,以便将接口GigabitEthernet1/0/1关闭。
<Sysname> system-view
[Sysname] scheduler job shutdownGE
[Sysname-job-shutdownGE] command 1 system-view
[Sysname-job-shutdownGE] command 2 interface gigabitethernet 1/0/1
[Sysname-job-shutdownGE] command 3 shutdown
copyright-info enable命令用来开启版权信息显示功能。
undo copyright-info enable命令用来关闭版权信息显示功能。
# 开启版权信息显示功能。
[Sysname] copyright-info enable
· 使用Telnet方式登录设备,会显示如下信息:
**************************************************************************
* Copyright (c) 2004-2014 Hangzhou H3C Tech. Co., Ltd. All rights reserved.*
* Without the owner's prior written consent, *
* no decompiling or reverse-engineering shall be allowed. *
****************************************************************************
<Sysname>
· 如果当前已经使用Console口登录设备了,再退出用户视图重新登录,会显示如下信息:
**************************************************************************
* Copyright (c) 2004-2014 Hangzhou H3C Tech. Co., Ltd. All rights reserved.*
* Without the owner's prior written consent, *
* no decompiling or reverse-engineering shall be allowed. *
****************************************************************************
User interface aux0 is available.
Press ENTER to get started.
# 禁止显示版权信息。
[Sysname] undo copyright-info enable
· 使用Telnet方式登录设备,会显示如下信息:
· 如果当前已经使用Console口登录设备了,再退出用户视图重新登录,会显示如下信息:
User interface aux0 is available.
Press ENTER to get started.
display alarm命令用来显示设备的告警信息。
display alarm [ slot slot-number ]
IRF模式:
display alarm [ chassis chassis-number slot slot-number ]
slot slot-number:显示指定单板的告警信息。slot-number表示单板所在的槽位号。不指定该参数时,则表示所有单板。(独立运行模式)
chassis chassis-number slot slot-number:显示指定成员设备上指定单板/PEX的告警信息。chassis-number表示设备在IRF中的成员编号或者PEX对应的虚拟框号,slot-number表示单板/PEX所在的槽位号。不指定该参数时,则表示IRF中的所有单板/PEX。(IRF模式)
# 显示设备的告警信息。(独立运行模式)
Slot CPU Level Info
- - INFO Power 1 is absent.
- - INFO Power 2 is absent.
- - INFO Power 3 is absent.
8 0 ERROR Board is faulty
9 0 ERROR Board is faulty
表1-1 display alarm命令显示信息描述表
产生告警的单板所在的槽位号(如果显示为“-”,则表示产生告警的元件位于机框上)(独立运行模式) |
|
告警单板的CPU编号 |
|
告警的级别,级别由高到低依次为ERROR、WARNING、NOTICE、INFO |
|
风扇n当前不在位 |
|
电源n当前不在位 |
|
单板处于faulty状态(该单板可能正在启动,或者当前处于故障状态) |
|
传感器n的温度低于低温门限 |
|
传感器n的温度高于高温门限 |
# 显示设备当前告警信息。(IRF模式)
Chassis Slot CPU Level Info
1 - - INFO Chassis 1 Power 1 is absent.
1 - - INFO Chassis 1 Power 2 is absent.
1 8 0 ERROR Chassis 1 Board is faulty
2 9 0 ERROR Chassis 2 Board is faulty
表1-2 display alarm命令显示信息描述表(IRF模式)
告警单板的CPU编号 |
|
告警的级别,级别由高到低依次为ERROR、WARNING、NOTICE、INFO |
|
风扇n当前不在位 |
|
电源n当前不在位 |
|
n号槽位上的单板处于faulty状态(该单板可能正在启动,或者当前处于故障状态) |
|
传感器n的温度低于低温门限 |
|
传感器n的温度高于高温门限 |
display asset-info命令用来显示设备的用户资产信息。使用该命令,可以显示设备机箱、单板、风扇框或电源模块的资产信息。
display asset-info { chassis | fan fan-id | power power-id | slot slot-number } [ csn | custom| department | description | location | service-date | state ]
display asset-info chassis chassis-number { chassis | fan fan-id | power power-id | slot slot-number } [ csn | custom| department | description | location | service-date | state ]
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
fan fan-id:显示指定风扇框的用户资产信息。fan-id表示设备上风扇框的编号。
power power-id:显示指定电源模块的用户资产信息。power-id表示设备上电源模块的编号。
slot slot-number:显示指定单板的用户资产信息。slot-number表示设备上单板所在的槽位号。
chassis chassis-number:显示指定成员设备的用户资产信息。chassis-number表示设备在IRF中的成员编号。(IRF模式)
当用户希望显示设备机箱、单板或风扇框的具体信息项目(比如资产编号、资产描述信息等)时,只需要选择该信息项目对应的命令行参数;不选择具体信息项目对应的参数时,显示的是该设备机箱、单板或风扇框的所有用户资产信息。
使用该命令显示设备机箱、单板、风扇框或电源模块没有经过设置的具体信息项目时,该信息项目的内容显示为空。
使用该命令显示指定风扇框或者电源模块的资产信息时,如果设备上无对应编号的风扇框或者电源模块,将返回风扇框或者电源模块不在位的提示信息。
# 显示设备上0号风扇框的资产编号信息(该显示信息与用户的当前配置有关)。(独立运行模式)
[Sysname] display asset-info fan 0 csn
# 显示设备上0号风扇框的资产信息(该显示信息与用户的当前配置有关)。(独立运行模式)
[Sysname] display asset-info fan 0
# 显示1号成员设备上0号风扇框的资产编号信息(该显示信息与用户的当前配置有关)。(IRF模式)
[Sysname] display asset-info chassis 1 fan 0 csn
# 显示1号成员设备上0号风扇框的资产信息(该显示信息与用户的当前配置有关)。(IRF模式)
[Sysname] display asset-info chassis 1 fan 0
表1-3 display asset-info命令显示信息描述表
【相关命令】
· reset asset-info
· set asset-info
display clock命令用来显示系统当前的时间、日期、本地时区以及夏令时配置。
# 没有配置本地时区时,显示系统当前日期和时间。
10:09:00 UTC Fri 03/16/2012
# 配置了本地时区Z5后,显示系统当前日期和时间。
15:10:00 Z5 Fri 03/16/2012
Time Zone : Z5 add 05:00:00
# 配置了本地时区Z5和夏令时PDT后,显示系统当前日期和时间。
15:11:00 Z5 Fri 03/16/2012
Time Zone : Z5 add 05:00:00
Summer Time : PDT 06:00:00 08/01 06:00:00 09/01 01:00:00
display copyright命令用来显示设备的版权信息。
通过查看版权信息,可以获知系统当前使用软件和硬件版本的版权信息、版权的参照标准、版权证书等相关信息。
# 显示设备的版权信息。
……显示信息略……
display cpu-usage命令用来显示CPU利用率的统计信息。
display cpu-usage [ slot slot-number [ cpu cpu-number ] ]
IRF模式:
display cpu-usage [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
slot slot-number:显示指定单板的CPU利用率的统计信息。slot-number表示单板所在的槽位号。不指定该参数时,显示的是所有单板的相应信息。(独立运行模式)
chassis chassis-number slot slot-number:显示指定成员设备指定单板的CPU利用率的统计信息。chassis-number表示设备在IRF中的成员编号或者PEX对应的虚拟框号,slot-number表示单板或PEX所在的槽位号。不指定该参数时,表示IRF中的所有单板/PEX。(IRF模式)
cpu cpu-number:显示指定CPU的利用率统计信息。cpu-number表示CPU的编号。不指定该参数时,表示默认CPU。
该命令用于显示最近5秒钟、最近1分钟、最近5分钟CPU利用率的平均值。
# 显示当前CPU利用率统计信息。(独立运行模式)
Slot 3 CPU 0 CPU usage:
2% in last 5 seconds
2% in last 1 minute
2% in last 5 minutes
Slot 7 CPU 0 CPU usage:
0% in last 5 seconds
0% in last 1 minute
0% in last 5 minutes
# 显示所有单板CPU利用率统计信息。(IRF模式)
Chassis 1 Slot 3 CPU 0 CPU usage:
2% in last 5 seconds
2% in last 1 minute
2% in last 5 minutes
Chassis 1 Slot 7 CPU 0 CPU usage:
0% in last 5 seconds
0% in last 1 minute
0% in last 5 minutes
表1-4 display cpu-usage命令显示信息描述表
设备启动后,会以5秒为周期计算并记录一次该5秒内的CPU的平均利用率。该字段显示的是最近一个5秒统计周期内CPU的平均利用率 |
|
设备启动后,会以1分钟为周期计算并记录一次该1分钟内的CPU的平均利用率。该字段显示的是最近一个1分钟统计周期内CPU的平均利用率 |
|
设备启动后,会以5分钟为周期计算并记录一次该5分钟内的CPU的平均利用率。该字段显示的是最近一个5分钟统计周期内CPU的平均利用率 |
|
x号单板上y号CPU的CPU利用率信息(独立运行模式) |
|
x号成员设备y号单板上z号CPU的CPU利用率信息(IRF模式) |
display cpu-usage configuration命令用来显示CPU利用率历史信息记录功能相关配置。
display cpu-usage configuration [ slot slot-number [ cpu cpu-number ] ]
IRF模式:
display cpu-usage configuration [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
slot slot-number:表示单板所在的槽位号。不指定该参数时,显示的是主用主控板上的相应信息。(独立运行模式)
chassis chassis-number slot slot-number:表示指定成员设备上的指定单板/PEX。chassis-number表示设备在IRF中的成员编号或者PEX对应的虚拟框号,slot-number表示单板或PEX所在的槽位号。不指定该参数时,显示的是全局主用主控板上的相应信息。(IRF模式)
cpu cpu-number:表示CPU的编号。不指定该参数时,表示默认CPU。
# 显示CPU利用率历史信息记录功能相关配置。
<Sysname> display cpu-usage configuration
CPU usage monitor is enabled.
Current monitor interval is 60 seconds.
Current monitor threshold is 99%.
· monitor cpu-usage threshold
display cpu-usage history命令用来以图表方式显示CPU利用率的历史信息。
display cpu-usage history [ job job-id ] [ slot slot-number [ cpu cpu-number ] ]
IRF模式:
job job-id:显示指定进程的CPU利用率的历史信息,job-id表示进程的编号。不指定该参数时,显示的是整个系统的相应信息(整个系统的CPU利用率等于所有进程CPU利用率之和)。可以使用display process命令可以查看当前运行的进程的编号和名称,display process命令的详细介绍请参见“网络管理与监控”中的“系统维护与调试”。
slot slot-number:显示指定单板的CPU利用率的历史信息。slot-number表示单板所在的槽位号。当不指定job和该参数时,显示的是所有单板上所有进程的相应信息;当指定job参数,但不指定该参数时,显示的是主用主控板上指定进程的相应信息。(独立运行模式)
chassis chassis-number slot slot-number:显示指定成员设备上指定单板/PEX的CPU利用率的历史信息。chassis-number表示设备在IRF中的成员编号或者PEX对应的虚拟框号,slot-number表示单板或PEX所在的槽位号。当不指定job和该参数时,显示的是所有单板和PEX上所有进程的相应信息;当指定job参数,但不指定该参数时,显示的是全局主用主控板上指定进程的相应信息。(IRF模式)
cpu cpu-number:显示指定CPU的利用率的历史信息。cpu-number表示CPU的编号。当不指定job和该参数时,表示所有CPU。当指定job参数,但不指定该参数时,表示默认CPU。
开启CPU利用率历史记录功能后,系统每隔一定时间(可通过monitor cpu-usage interval命令配置)会对CPU的利用率进行采样,并把采样结果保存到历史记录区。通过display cpu-usage history命令可以查看到最近60个采样点的值。结果以坐标的形式进行显示,显示信息中:
· 纵坐标表示利用率,采用就近显示的原则。比如,利用率的间隔为5%,则实际统计值53%将被显示成55%,实际统计值52%将被显示成50%。
· 用连续的#号表示该时刻的利用率,某个时间点上最高处的#号对应的纵坐标值即为该时刻CPU的利用率。
# 以图表方式显示整个系统的CPU利用率的历史记录。
<Sysname> display cpu-usage history
100%|
95%|
90%|
85%|
80%|
75%|
70%|
65%|
60%|
55%|
50%|
45%|
40%|
35%|
30%|
25%|
20%|
15%| #
10%| ### #
5%| ########
------------------------------------------------------------
10 20 30 40 50 60 (minutes)
cpu-usage (Chassis 1 Slot 7 CPU 0)
以上显示信息表明系统(用“SYSTEM”表示,运行在Chassis 1 Slot 7 CPU 0上)在最近60分钟内CPU的利用率情况:12分钟前大约为5%,13分钟前大约为10%,14分钟前大约为15%,15分钟前大约为10%,16、17分钟前大约为5%,18分钟前大约为10%,19分钟前大约为5%,其它时间均小于或等于2%。
# 以图表方式显示编号为1的进程的CPU利用率的历史记录。
<Sysname> display cpu-usage history job 1
100%|
95%|
90%|
85%|
80%|
75%|
70%|
65%|
60%|
55%|
50%|
45%|
40%|
35%|
30%|
25%|
20%|
15%|
10%|
5%| #
------------------------------------------------------------
10 20 30 40 50 60 (minutes)
cpu-usage (Chassis 1 Slot 7 CPU 0)
以上显示信息表明Chassis 1 Slot 7 CPU 0上编号为1的进程(进程名为scmd,如果进程名带有“[]”标识则表示它是内核线程)在最近60分钟内CPU的利用率情况:20分钟前大约为5%,其它时间均小于或等于2%。
display device命令用来显示设备信息。
display device [ flash ] [ slot slot-number [ subslot msubslot-number ] | verbose ]
IRF模式:
flash:显示Flash的信息。
chassis chassis-number:显示指定成员设备的详细信息。chassis-number表示设备在IRF中的成员编号或者PEX对应的虚拟框号。不指定该参数时,表示所有成员设备和虚拟框。(IRF模式)
slot slot-number:显示指定单板的信息。slot-number表示单板所在的槽位号。不指定该参数时,表示所有单板。(独立运行模式)
slot slot-number:显示指定单板/PEX的信息。slot-number表示单板或者PEX所在的槽位号。不指定该参数时,表示所有单板/PEX。(IRF模式)
subslot subslot-number:显示指定接口子卡的信息。subslot-number表示接口子卡所在的子槽位号。不指定该参数时,不会显示接口子卡的信息。该参数暂不支持。
verbose:显示设备的详细信息。不指定该参数时,显示设备的简要信息。
#显示设备信息。(独立运行模式)
Slot Type State Subslot Soft Ver Patch Ver
0 NONE Absent 0 NONE None
1 NONE Absent 0 NONE None
2 NONE Absent 0 NONE None
3 LSXM1GT24PTSSE3 Normal 0 S12500-S-7178 None
4 NONE Absent 0 NONE None
5 NONE Absent 0 NONE None
6 NONE Absent 0 NONE None
7 LSXM1MPU06B3 Master 0 S12500-S-7178 None
8 NONE Fault 0 NONE None
9 NONE Fault 0 NONE None
以上显示信息表明,该独立运行模式上有一块主控板,一块接口板。其中插在7号槽位的是主用主控板,插在3号槽位的是接口板。
表1-5 display device命令显示信息描述表(独立运行模式)
· Standby表示该板是备用主控板 · Master表示该板是主用主控板 · Absent表示该槽位没有插入单板 · Fault表示该槽位单板出错,不能正常启动 · Normal表示该槽位单板是接口板并处于正常工作状态 · Offline表示该槽位网板处于隔离状态 |
|
单板支持接口子卡的最大个数(暂不支持) |
|
# 显示IRF中各成员设备的设备信息。(IRF模式)
Slot Type State Subslot Soft Ver Patch Ver
1/0 NONE Absent 0 NONE None
1/1 NONE Absent 0 NONE None
1/2 NONE Absent 0 NONE None
1/3 LSXM1GT24PTSSE3 Normal 0 S12500-S-7178 None
1/4 NONE Absent 0 NONE None
1/5 NONE Absent 0 NONE None
1/6 NONE Absent 0 NONE None
1/7 LSXM1MPU06B3 Master 0 S12500-S-7178 None
1/8 NONE Fault 0 NONE None
1/9 NONE Fault 0 NONE None
以上显示信息表明,该IRF中包含一台成员设备,成员编号分别为1。从单板状态可以看出,成员设备1的7号单板为整个IRF的主用主控板,成员设备1的3号槽位的是接口板。
表1-6 display device命令显示信息描述表(IRF模式)
Slot1/3 |
1表示设备在IRF中的成员编号,3表示成员设备上单板所在的槽位号 |
· Absent:单板不在位 · Master:单板为全局主用主控板(即整个IRF的主用主控板) · Standby:单板为全局备用主控板(即整个IRF的备用主控板) · Normal:单板为接口板,并且状态正常 · Fault:单板状态异常 |
|
单板支持接口子卡的最大个数(暂不支持) |
|
当前单板上运行的热补丁版本,None表示没有补丁 |
display device manuinfo命令用来显示设备的电子标签信息。
display device manuinfo [ slot slot-number [ subslot subslot-number ] ]
IRF模式:
display device manuinfo [ chassis chassis-number [ slot slot-number [ subslot subslot-number ] ] ]
chassis chassis-number:显示指定成员设备/虚拟框的电子标签信息。chassis-number表示设备在IRF中的成员编号或者PEX对应的虚拟框号。不输入该参数时,显示所有成员设备/虚拟框的相应信息。(IRF模式)
slot slot-number:显示指定单板的电子标签信息。slot-number表示单板所在的槽位号。不输入该参数时,显示所有单板的相应信息。(独立运行模式)
slot slot-number:显示指定单板/PEX的电子标签信息。slot-number表示单板/PEX所在的槽位号。不输入该参数时,显示所有单板/PEX的相应信息。(IRF模式)
subslot subslot-number:显示指定接口子卡的电子标签信息。subslot-number表示接口子卡所在的子槽位号。不指定该参数时,不会显示接口子卡的信息。该参数暂不支持。
电子标签信息也可以称为永久配置数据或档案信息等,在单板或者设备的调测(调试、测试)过程中被写入到设备的存储器件中,包括单板的名称、生产序列号、MAC地址、制造商等信息。本命令显示的是设备的部分电子标签信息。
# 显示设备的电子标签信息。(独立运行模式)
<Sysname> display device manuinfo
Chassis self:
DEVICE_NAME : LS-12506-S
DEVICE_SERIAL_NUMBER : 210235A1H19876543220
MAC_ADDRESS : NONE
MANUFACTURING_DATE : 2014-12-29
VENDOR_NAME : H3C
Slot 6 CPU 0:
DEVICE_NAME : LSXM1MPU06B3
DEVICE_SERIAL_NUMBER : 210231A2VP1236547987
MAC_ADDRESS : 00FE-5689-AA60
MANUFACTURING_DATE : 2014-12-26
VENDOR_NAME : H3C
Fan 0:
DEVICE_NAME : LSUM106FAN
DEVICE_SERIAL_NUMBER : 210231A2YG9876543210
MAC_ADDRESS : NONE
MANUFACTURING_DATE : 2014-12-29
VENDOR_NAME : H3C
Power 0
DEVICE_NAME : POWER
DEVICE_SERIAL_NUMBER : 210231A0PPX127000196
MAC_ADDRESS : NONE
MANUFACTURING_DATE : 2012-07-05
VENDOR_NAME : H3C
表1-7 display device manuinfo命令信息显示描述表
单板所在的槽位号和CPU编号(独立运行模式) |
|
设备出厂MAC地址 |
|
# 显示设备的电子标签信息。(IRF模式)
<Sysname> display device manuinfo
Chassis 1:
Chassis self:
DEVICE_NAME : LS-12506-S
DEVICE_SERIAL_NUMBER : 210235A1H19876543220
MAC_ADDRESS : NONE
MANUFACTURING_DATE : 2014-12-29
VENDOR_NAME : H3C
Slot 6 CPU 0:
DEVICE_NAME : LSXM1MPU06B3
DEVICE_SERIAL_NUMBER : 210231A2VP1236547987
MAC_ADDRESS : 00FE-5689-AA60
MANUFACTURING_DATE : 2014-12-26
VENDOR_NAME : H3C
Fan 0:
DEVICE_NAME : LSUM106FAN
DEVICE_SERIAL_NUMBER : 210231A2YG9876543210
MAC_ADDRESS : NONE
MANUFACTURING_DATE : 2014-12-29
VENDOR_NAME : H3C
表1-8 display device manuinfo命令信息显示描述表
Slot m CPU n |
m号单板的n号CPU的相关信息 |
设备出厂MAC地址 |
|
display device manuinfo chassis-only命令用来显示指定机框背板的电子标签信息。
display device manuinfo chassis-only
IRF模式:
display device manuinfo chassis chassis-number chassis-only
chassis chassis-number:表示设备在IRF中的成员编号或者PEX对应的虚拟框号。(IRF模式)
# 显示机框背板的电子标签信息。(独立运行模式)
<Sysname> display device manuinfo chassis-only
Chassis self:
DEVICE_NAME : LS-12506-S
DEVICE_SERIAL_NUMBER : 210235A1H19876543220
MAC_ADDRESS : NONE
MANUFACTURING_DATE : 2014-12-29
VENDOR_NAME : H3C
# 显示成员设备1上机框背板的电子标签信息。(IRF模式)
<Sysname> display device manuinfo chassis 1 chassis-only
Chassis 1:
Chassis self:
DEVICE_NAME : LS-12506-S
DEVICE_SERIAL_NUMBER : 210235A1H19876543220
MAC_ADDRESS : NONE
MANUFACTURING_DATE : 2014-12-29
VENDOR_NAME : H3C
显示信息中的参数仅供参考,请以设备实际显示为准。
display device manuinfo fan命令用来显示指定风扇的电子标签信息。
display device manuinfo fan fan-id
IRF模式:
chassis { chassis-number | virtual-chassis-number slot slot-number }: chassis-number表示设备在IRF中的成员编号;virtual-chassis-number表示PEX对应的虚拟框号,slot-number表示PEX在虚拟框中的槽位号。(IRF模式)
fan-id:表示设备上风扇的ID编号。
# 显示风扇0的电子标签信息。(独立运行模式)
<Sysname> display device manuinfo fan 0
Fan 0:
DEVICE_NAME : LSUM106FAN
DEVICE_SERIAL_NUMBER : 210231A2YG9876543210
MAC_ADDRESS : NONE
MANUFACTURING_DATE : 2014-12-29
VENDOR_NAME : H3C
# 显示成员设备1上风扇0的电子标签信息。(IRF模式)
<Sysname> display device manuinfo chassis 1 fan 0
Chassis 1:
Fan 0:
DEVICE_NAME : LSUM106FAN
DEVICE_SERIAL_NUMBER : 210231A2YG9876543210
MAC_ADDRESS : NONE
MANUFACTURING_DATE : 2014-12-29
VENDOR_NAME : H3C
显示信息中的参数仅供参考,请以设备实际显示为准。
display device manuinfo power命令用来显示指定电源的电子标签信息。
display device manuinfo power power-id
IRF模式:
chassis { chassis-number | virtual-chassis-number slot slot-number }:chassis-number表示设备在IRF中的成员编号;virtual-chassis-number表示PEX对应的虚拟框号,slot-number表示PEX在虚拟框中的槽位号。(IRF模式)
power-id:表示设备上电源的ID编号。
# 显示电源2的电子标签信息。(独立运行模式)
<Sysname> display device manuinfo power 2
Power 2
DEVICE_NAME : POWER
DEVICE_SERIAL_NUMBER : 210231A0PPX127000196
MAC_ADDRESS : NONE
MANUFACTURING_DATE : 2012-07-05
VENDOR_NAME : H3C
# 显示成员设备1上电源监控模块2的电子标签信息。(IRF模式)
<Sysname> display device manuinfo chassis 1 power 2
Chassis 1:
Power 2
DEVICE_NAME : POWER
DEVICE_SERIAL_NUMBER : 210231A0PPX127000196
MAC_ADDRESS : NONE
MANUFACTURING_DATE : 2012-07-05
VENDOR_NAME : H3C
显示信息中的参数仅供参考,请以设备实际显示为准。
display diagnostic-information命令用来显示诊断信息。
display diagnostic-information [ hardware | infrastructure | l2 | l3 | service ] [ filename ]
hardware:收集硬件相关诊断信息。
infrastructure:收集基础模块的诊断信息。
l2:收集二层特性相关诊断信息。
l3:收集三层特性相关诊断信息。
service:收集上层业务模块相关诊断信息。
filename:表示将收集到的诊断信息保存到指定文件。filename表示文件的名称,后缀必须为“.tar.gz”。不指定该参数时,用户可根据提示信息选择将诊断信息保存到指定文件或者是直接显示诊断信息。
在日常维护或系统出现故障时,为了便于问题定位,用户需要查看各个功能模块的运行信息。因为各个功能模块都有其对应的运行信息,所以一般情况下,用户需要逐条运行相应的display命令。为便于一次性收集更多信息,用户可以在任意视图下执行display diagnostic-information命令,显示系统当前多个功能模块运行的统计信息。
使用该命令,用户可以直接显示指定的诊断信息或者将诊断信息直接保存到指定文件,保存到指定文件时会同时收集设备上的core文件,因为诊断信息较多,core文件较大,系统会自动将该文件压缩后保存,默认文件名组成为diag_sysname_年月日-时分秒,文件名后缀为“.tar.gz”。如果要在设备上查看该文件的内容,请使用tar extract命令解包后再使用more命令查看。
未指定hardware、infrastructure、l2、l3和service参数时,将收集设备产生的所有诊断信息。
该命令不支持“|”、“>”和“>>”参数。
# 显示系统当前各个功能模块运行的统计信息。
<Sysname> display diagnostic-information
==================================================================
===============display cpu===============
Slot 3 CPU 0 CPU usage:
2% in last 5 seconds
3% in last 1 minute
2% in last 5 minutes
Slot 7 CPU 0 CPU usage:
1% in last 5 seconds
1% in last 1 minute
1% in last 5 minutes
===========================================================
=================================================================
===============display cpu-usage history slot 3 ===============
# 将收集到的诊断信息保存到文件test.tar.gz。
· 方法一:在交互信息时选择将诊断信息保存到指定文件,并输入文件名test.tar.gz。
<Sysname> display diagnostic-information
Save or display diagnostic information (Y=save, N=display)? [Y/N]:y
Please input the file name(*.tar.gz)[flash:/diag_sysname_20140829-083832.tar.gz]:
test.tar.gz
Diagnostic information is outputting to flash:/test.tar.gz.
Please wait...
Save successfully.
· 方法二:在命令行中直接通过参数指定将诊断信息保存到文件test.tar.gz。
<Sysname> display diagnostic-information test.tar.gz
Diagnostic information is outputting to flash:/test.tar.gz.
Please wait...
Save successfully.
· more(基础配置命令参考/文件系统管理)
· tar extract(基础配置命令参考/文件系统管理)
display environment命令用来显示设备上温度传感器的温度信息,包括当前温度和设定的温度告警门限。
display environment [ slot slot-number ]
IRF模式:
display environment [ chassis chassis-number [ slot slot-number ] ]
chassis chassis-number:显示IRF中指定成员设备或者PEX上温度传感器的温度信息。chassis-number表示设备在IRF中的成员编号或者PEX的虚拟框号。不指定该参数时,显示所有成员设备和虚拟框的对应信息。(IRF模式)
slot slot-number:显示设备中指定单板上的温度传感器的温度信息。slot-number表示单板所在的槽位号。不指定该参数时,显示所有单板的对应信息。(独立运行模式)
slot slot-number:显示设备中指定单板/PEX上的温度传感器的温度信息。slot-number表示单板/PEX所在的槽位号。不指定该参数时,显示所有单板和PEX的对应信息。(IRF模式)
· 不指定slot参数时,显示的是设备上所有温度传感器的温度信息。(独立运行模式)
· 不指定chassis参数时,显示的是IRF中所有温度传感器的温度信息;指定chassis但不指定slot时,显示的是指定成员设备上所有温度传感器的温度信息。(IRF模式)
# 显示设备上所有温度传感器的温度信息。(独立运行模式)
System temperature information (degree centigrade):
----------------------------------------------------------------------
Slot Sensor Temperature Lower Warning Alarm Shutdown
3 hotspot 1 38 0 80 97 NA
3 hotspot 2 49 0 80 97 NA
7 inflow 1 31 0 71 90 NA
7 outflow 1 44 0 80 99 NA
7 hotspot 1 47 0 81 100 NA
7 hotspot 2 53 0 88 107 NA
表1-9 display environment命令显示信息描述表
· hotspot:表示热点温度传感器 · inflow:表示入风口温度传感器 · outflow:表示出风口温度传感器 |
|
一般级(Warning)高温告警门限 |
|
严重级(Alarm)高温告警门限 |
|
关断级(Shutdown)高温告警门限,当温度传感器的温度大于该门限时,设备会自动关闭 |
display fan命令用来显示设备风扇的工作状态。
IRF模式:
display fan [ chassis { chassis-number | virtual-chassis-number slot slot-number } [ fan-id ] ]
chassis { chassis-number | virtual-chassis-number slot slot-number }:显示指定成员设备或者PEX上风扇的状态信息。chassis-number表示设备在IRF中的成员编号;virtual-chassis-number表示PEX对应的虚拟框号,slot-number表示PEX在虚拟框中的槽位号。不指定chassis参数时,表示所有风扇。(IRF模式)
fan-id:表示设备内置风扇的编号。不指定该参数时,表示指定位置的所有风扇。
# 显示设备上所有风扇的工作状态。
Fan Frame 1 State: Normal
display memory命令用来显示内存使用情况。
display memory [ slot slot-number [ cpu cpu-number ] ]
IRF模式:
display memory [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
slot slot-number:表示单板所在的槽位号,不指定时显示当前所有单板的内存使用情况。(独立运行模式)
chassis chassis-number slot slot-number:表示指定成员设备上的指定单板,不指定时显示当前所有单板的内存使用情况。(IRF模式)
cpu cpu-number:表示CPU编号。不指定该参数时,表示默认CPU。
# 显示设备的内存使用情况。(独立运行模式)
The statistics about memory is measured in KB:
Slot 3:
Total Used Free Shared Buffers Cached FreeRatio
Mem: 999968 345792 654176 0 0 28496 65.4%
-/+ Buffers/Cache: 317296 682672
Swap: 0 0 0
Slot 7:
Total Used Free Shared Buffers Cached FreeRatio
Mem: 8135316 737928 7397388 0 152 175584 90.9%
-/+ Buffers/Cache: 562192 7573124
Swap: 0 0 0
# 显示设备的内存使用情况。(IRF模式)
<Sysname> display memory
The statistics about memory is measured in KB:
Chassis 1 Slot 3:
Total Used Free Shared Buffers Cached FreeRatio
Mem: 999968 345792 654176 0 0 28496 65.4%
-/+ Buffers/Cache: 317296 682672
Swap: 0 0 0
Chassis 1 Slot 7:
Total Used Free Shared Buffers Cached FreeRatio
Mem: 8135316 737928 7397388 0 152 175584 90.9%
-/+ Buffers/Cache: 562192 7573124
Swap: 0 0 0
表1-10 display memory命令显示信息描述表
单板所在的槽位号(IRF模式) |
|
设备总物理内存分为不可分配物理内存和可分配物理内存。其中,不可分配物理内存用于内核代码段存储、内核管理开销以及ISSU功能运行等;可分配物理内存用于支撑业务模块的运行、文件存储等操作。不可分配内存的大小由设备根据系统运行需要自动计算划分,可分配物理内存的大小等于设备总物理内存减去不可分配内存的大小 |
|
-/+ Buffers/Cache:used = Mem:Used – Mem:Buffers – Mem:Cached,表示应用程序已用的物理内存大小 -/+ Buffers/Cache:free = Mem:Free + Mem:Buffers + Mem:Cached,表示应用程序可用的物理内存大小 |
|
display memory-threshold命令用来显示内存告警门限相关信息。
display memory-threshold [ slot slot-number [ cpu cpu-number ] ]
IRF模式:
display memory-threshold [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
slot slot-number:表示单板所在的槽位号。不指定该参数时,表示主用主控板。(独立运行模式)
chassis chassis-number slot slot-number:表示指定单板/PEX。chassis-number表示设备在IRF中的成员编号或者PEX对应的虚拟框号,slot-number表示单板/PEX所在的槽位号。不指定该参数时,表示全局主用主控板。(IRF模式)
cpu cpu-number:表示CPU编号。不指定该参数时,表示默认CPU。
当设备已经使用的物理内存大小超过内存某个告警门限阈值时,系统会认为发生了一次该类型内存异常,并记录第一次、最近一次发生异常的时间,以及这段时间内发生的该类异常的次数。如果想了解该类异常的详细情况,请查看日志信息,可按日志摘要关键字“MEM_EXCEED_THRESHOLD”或“MEM_BELOW_THRESHOLD”进行搜索。
# 显示内存告警门限相关信息。
<Sysname> display memory-threshold
Memory usage threshold: 100%
Free memory threshold:
Minor: 96M
Severe: 64M
Critical: 48M
Normal: 128M
Current memory state: Normal
Event statistics:
[Back to normal state]
First notification: 0.0
Latest notification: 0.0
Total number of notifications sent: 0
[Enter minor low-memory state]
First notification at: 0.0
Latest notification at: 0.0
Total number of notifications sent: 0
[Back to minor low-memory state]
First notification at: 0.0
Latest notification at: 0.0
Total number of notifications sent: 0
[Enter severe low-memory state]
First notification at: 0.0
Latest notification at: 0.0
Total number of notifications sent: 0
[Back to severe low-memory state]
First notification at: 0.0
Latest notification at: 0.0
Total number of notifications sent: 0
[Enter critical low-memory state]
First notification at: 0.0
Latest notification at: 0.0
Total number of notifications sent: 0
表1-11 display memory-threshold命令显示信息描述表
· Minor:一级告警门限,单位为MB · Severe:二级告警门限,单位为MB · Critical:三级告警门限,单位为MB · Normal:恢复到正常状态的阈值,单位为MB |
|
· Normal:正常状态 · Minor:一级告警门限状态 · Severe:二级告警门限状态 · Critical:三级告警门限状态 |
|
· Back to normal state:内存恢复到正常状态 · Enter minor low-memory state:进入一级告警门限状态 · Back to minor low-memory state:恢复到一级告警门限状态 · Enter severe low-memory state:进入二级告警门限状态 · Back to severe low-memory state:恢复到二级告警门限状态 · Enter critical low-memory state:进入三级告警门限状态 |
|
display power命令用来显示设备电源的信息。
display power [ power-id ]
IRF模式:
display power [ chassis { chassis-number | virtual-chassis-number slot slot-number } [ power-id ] ]
chassis { chassis-number | virtual-chassis-number slot slot-number }:显示指定成员设备或者PEX上电源的信息。chassis-number表示设备在IRF中的成员编号;virtual-chassis-number表示PEX对应的虚拟框号,slot-number表示PEX在虚拟框中的槽位号。不指定chassis参数时,表示所有电源。(IRF模式)
power-id:表示电源的编号。不指定该参数时,表示指定位置的所有电源。
当S5130-EI系列交换机作为PEX设备时,本设备上不会显示该设备的电源功率。
【举例】
# 显示设备电源的状况。
Power 1 State: Normal
Power 2 State: Absent
Power 3 State: Absent
Power 4 State: Absent
display scheduler job命令用来查看Job的配置信息,包括Job的名称和分配的命令。
display scheduler job [ job-name ]
job-name:Job的名称,为1~47个字符的字符串,区分大小写。不指定该参数时,则显示所有Job的配置信息。
# 查看所有Job的配置信息。
<Sysname> display scheduler job
Job name: saveconfig
copy startup.cfg backup.cfg
Job name: backupconfig
Job name: creat-VLAN100
system-view
vlan 100
以上显示信息表明,设备当前配置了3个Job,分别显示了Job的名称,以及为Job分配的命令(如果没有为Job分配命令,则只显示Job的名称),不同Job间用空行分隔。
display scheduler logfile命令用来显示已执行的Job的日志信息,包括Job的名称、对应的Schedule的名称、执行时间以及执行结果。
# 显示Schedule日志文件的相关信息。
<Sysname> display scheduler logfile
Logfile Size: 1902 Bytes.
Job name : shutdown
Schedule name : shutdown
Execution time : Tue Dec 27 10:44:42 2011
Completion time : Tue Dec 27 10:44:47 2011
--------------------------------- Job output -----------------------------------
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname]interface rang gigabitethernet 1/0/1 to gigabitethernet 1/0/3
[Sysname-if-range]shutdown
表1-12 display scheduler logfile命令显示信息描述表
Schedule日志文件的大小,单位为字节 |
|
Job的名称 |
|
Schedule的名称 |
|
开始执行Job的时间 |
|
Job执行结束的时间(没有调度的或者没有分配命令的Job,均不会显示该信息) |
|
Job中的命令执行时的输出信息 |
display scheduler reboot命令用来查看定时重启功能的相关配置。
# 查看定时重启功能的相关配置。
<Sysname> display scheduler reboot
System will reboot at 16:32:00 05/23/2011 (in 1 hours and 39 minutes).
display scheduler schedule命令用来查看Schedule的相关信息。
display scheduler schedule [ schedule-name ]
schedule-name:Schedule的名称,为1~47个字符的字符串,区分大小写。如果不指定该参数,则显示所有Schedule的信息。
# 查看所有Schedule的信息。
<Sysname> display scheduler schedule
Schedule name : START-pc1/pc2
Schedule type : Run on every Mon Tue Wed Thu Fri at 08:00:00
Start time : Thu Aug 7 08:00:00 2014
Last execution time : Yet to be executed
-----------------------------------------------------------------------
Job name Last execution status
start-GigabitEthernet1/0/1 -NA-
start-GigabitEthernet1/0/2 -NA-
Schedule name : STOP-pc1/pc2
Schedule type : Run on every Mon Tue Wed Thu Fri at 18:00:00
Start time : Wed Aug 6 18:00:00 2014
Last execution time : Yet to be executed
-----------------------------------------------------------------------
Job name Last execution status
shutdown-GigabitEthernet1/0/1 -NA-
shutdown-GigabitEthernet1/0/2 -NA-
Schedule name : saveconfig
-----------------------------------------------------------------------
Job name Last execution status
1 -NA-
表1-13 display scheduler schedule命令显示信息描述表
Schedule的名称 |
|
Schedule的执行时间配置。如果没有为Schedule配置执行时间,则不会显示该信息 |
|
Schedule第一次开始执行的时间。如果没有为Schedule配置执行时间,则不会显示该信息 |
|
Schedule上一开始执行的时间 · 如果没有为Schedule配置执行时间,则不会显示该信息 |
|
Schedule上一次执行完成的时间。如果没有为Schedule配置执行时间,则不会显示该信息 |
|
Schedule已经执行的次数。如果Schedule还没有执行,则不会显示该信息 |
|
Schedule下关联的Job的名称 |
|
Job上一次被执行的状态(Job下分配的命令是否执行以及执行结果,请通过display scheduler logfile命令查看) · Successful:表示执行成功 · Failed:表示执行失败 · Waiting:表示正在等待被执行 · In process:表示正在执行 · -NA-:表示还没有到执行时间 |
display switch-mode status用于查看所有业务板当前的工作模式和业务板配置的工作模式。
【命令】
独立运行模式:
display switch-mode status
IRF模式:
display switch-mode status chassis chassis-number
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【参数】
chassis chassis-number:显示指定成员设备上所有业务板当前的工作模式和业务板配置的工作模式。chassis-number表示设备在IRF中的成员编号。(IRF模式)
【使用指导】
使用undo switch-mode命令将业务板的工作模式恢复到未配置状态(即config显示为NONE),保存配置并重启该业务板后,业务板将以缺省工作模式启动。
【举例】
# 查看交换机所有业务板当前的工作模式和业务板配置的工作模式。(独立运行模式)
<Sysname> display switch-mode status
LPU switch mode:
Slot Current Config
2 NORMAL *BRIDGING
3 MIX NONE
4 NORMAL NORMAL
5 MIX BRIDGING
* indicates the mode is not supported.
CurrentForwardMode: compatible
NextForwardMode: high-speed
# 查看IRF中1号成员设备的所有业务板当前的工作模式和业务板配置的工作模式。(IRF模式)
<Sysname> display switch-mode status chassis 1
LPU switch mode:
Slot Current Config
2 MIX MIX
3 MIX NONE
4 NORMAL NORMAL
5 MIX BRIDGING
CurrentForwardMode: compatible
NextForwardMode: high-speed
表1-14 display switch-mode status显示信息描述表
字段 |
说明 |
Slot |
单板槽位号 |
LPU switch mode |
业务板的工作模式 |
Current |
业务板当前的工作模式: NONE:单板不支持配置业务板的工作模式 BRIDGING:业务板当前的工作模式为MAC扩展模式 NORMAL:业务板当前的工作模式为普通模式 ROUTING:业务板当前的工作模式为路由扩展模式 MIX:业务板当前的工作模式为混合扩展模式 IPv6:业务板当前的工作模式为IPv6模式 STANDARD-IPV6:业务板当前的工作模式为IPv6标准模式 |
Config |
业务板配置的工作模式: NONE:目前没有对业务板配置工作模式 BRIDGING:业务板配置的工作模式为MAC扩展模式 NORMAL:业务板配置的工作模式为普通模式 ROUTING:业务板配置的工作模式为路由扩展模式 MIX:业务板配置的工作模式为混合扩展模式 IPv6:业务板当前的工作模式为IPv6模式 STANDARD-IPV6:业务板配置的工作模式为IPv6标准模式 |
* indicates the mode is not supported. |
*表示插入某一槽位的业务板不支持该槽位已配置的工作模式,业务板将以缺省工作模式启动 |
CurrentForwardMode |
当前业务板槽位转发模式 · compatible:将业务板槽位转发模式设置为兼容模式 · standard:将业务板槽位转发模式设置为标准模式 · high-speed:将业务板槽位转发模式设置为高速模式 |
NextForwardMode |
下次业务板槽位转发模式 · compatible:将业务板槽位转发模式设置为兼容模式 · standard:将业务板槽位转发模式设置为标准模式 · high-speed:将业务板槽位转发模式设置为高速模式 |
【相关命令】
· switch-mode
· fabric-mode
display system stable state命令用来显示系统的稳定状态。
【命令】
display system stable state [ mdc { id | all } ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【参数】
mdc { id | all }:显示指定或所有MDC的系统稳定状态。id表示MDC的编号。
【使用指导】
不指定mdc参数时,显示系统的稳定状态。
在进行ISSU升级或主备倒换前,请先执行该命令,检查设备是否处于稳定状态。如果System State未处于Stable状态,不能进行ISSU升级;如果Redundancy Stable未处于Stable状态,不能进行主备倒换。
设备/单板/MDC启动需要一定的时间,才能达到Stable状态。如果设备/单板/MDC长时间未能进入Stable状态,可通过该命令的显示信息找出未稳定的设备/单板/MDC,根据其具体状态,采取进一步措施。
系统处于不稳定状态时,需要结合相关命令查看设备的具体情况。例如:
· 通过display device命令查看设备是否处于故障状态。
· 通过display ha service-group命令查看HA服务组的状态,以找出未批备完成的模块。
操作时,建议多次执行命令,以确认稳定状态的连续性。
【举例】
# 显示系统的稳定状态。(独立运行模式)
<Sysname> display system stable state
System state : Stable
Redundancy state: Stable
Slot CPU Role State
* 1 0 Active Stable
表1-15 display system stable state命令显示信息描述表
字段 |
描述 |
System state |
系统状态: · Stable:稳定运行 · Not ready:未稳定,此时不能进行ISSU升级 |
Redundancy state |
主备状态: · Stable:主备状态稳定,可以倒换 · No Redundance:系统无冗余,不能倒换 · Not Ready:未稳定,不可以倒换 |
Role |
单板在系统中的身份: · Active:主用主控板 · Standby:备用主控板,提供冗余备份 · Other:其它类型单板 |
State |
单板状态: · Stable:单板稳定运行 · Board Inserted:单板插入 · Kernel Init:单板内核初始化 · Service Starting:单板上的服务正在启动 · Service Stopping:单板上的服务正在关闭 · HA Batch Backup:HA批量备份中 · Interface Data Batch Backup:接口管理批量备份未完成 · MDC Starting:MDC正在启动 · MDC Stopping:MDC正在关闭 |
* |
当前对象处于未稳定状态 |
【相关命令】
· display device
· display ha service-group(可靠性命令参考/进程分布优化)
· display mdc(虚拟化技术命令参考/MDC)
display system-working-mode命令用来显示设备当前的工作模式。
# 显示设备当前的工作模式。
<Sysname> display system-working-mode
The current system working mode is standard.
The system working mode for next startup is standard.
display transceiver alarm命令用来显示可插拔接口模块的当前故障告警信息。
display transceiver alarm interface [ interface-type interface-number ]
interface [ interface-type interface-number ]:显示接口上插入的可插拔接口模块的当前故障告警信息。interface-type interface-number表示接口类型和接口编号,如果不指定该参数,表示所有接口。
目前,使用的可插拔接口模块可能出现的故障告警信息见表1-16。如果没有故障,则显示为None。
表1-16 display transceiver alarm命令输出信息描述表
字段 |
描述 |
SFP/SFP+ |
|
RX loss of signal |
接收信号丢失 |
RX power high |
接收光功率高 |
RX power low |
接收光功率低 |
TX fault |
发送错误 |
TX bias high |
偏置电流高 |
TX bias low |
偏置电流低 |
TX power high |
发送光功率高 |
TX power low |
发送光功率低 |
Temp high |
温度高 |
Temp low |
温度低 |
Voltage high |
电压高 |
Voltage low |
电压低 |
Transceiver info I/O error |
模块信息读写错误 |
Transceiver info checksum error |
模块信息校验和错误 |
Transceiver type and port configuration mismatch |
模块类型和端口配置不匹配 |
Transceiver type not supported by port hardware |
端口不支持该模块类型 |
QSFP+ |
|
Temp high |
温度高 |
Temp low |
温度低 |
Voltage high |
电压高 |
Voltage low |
电压低 |
RX signal loss in channel x |
通道x接收到的信号丢失 |
TX fault in channel x |
通道x发送报文时出错 |
TX signal loss in channel x |
通道x发送的信号丢失 |
RX power high in channel x |
通道x接收到的光的功率太高 |
RX power low in channel x |
通道x接收到的光的功率太低 |
TX bias high in channel x |
通道x的偏置电流高 |
TX bias low in channel x |
通道x的偏置电流低 |
Transceiver info I/O error |
模块读写错误 |
Transceiver info checksum error |
模块信息校验和错误 |
Transceiver type and port configuration mismatched |
模块类型和端口配置不匹配 |
Transceiver type not supported |
端口不支持该类型的模块 |
CFP |
|
TX jitter PLL unlocked |
发送Jitter PLL失锁 |
TX CMU unlocked |
发送CMU失锁 |
Overloaded |
负载过大 |
Loss of REFCLK input |
缺乏参考时钟 |
Channel signals out of alignment |
主机通道信号不对齐 |
PLD or flash initialization error |
初始化错误 |
Power supply fault |
电源错误 |
CFP checksum error |
校验和错误 |
TX bias high |
偏置电流高 |
TX bias low |
偏置电流低 |
Temp high |
温度高 |
Temp low |
温度低 |
Voltage high |
电压高 |
Voltage low |
电压低 |
RX signal loss in channel x |
通道x接收到的信号丢失 |
RX IC unlocked in channel x |
通道x接收到的IC时钟失锁 |
RX FIFO error in channel x |
通道x接收到FIFO错误 |
TX signal loss in channel x |
通道x发送的信号丢失 |
TX IC unlocked in channel x |
通道x发送的IC时钟失锁 |
TX FIFO error in channel x |
主机通道x的发送FIFO出错 |
TX IC unlocked in channel x |
主机通道x发送的IC时钟失锁 |
APD supply fault in channel x |
通道x出现APD错误 |
TEC fault in channel x |
通道x出现TEC错误 |
Wavelength unlocked in channel x |
通道x的光信号波长失锁 |
RX power high in lane x |
通道x接收到的光的功率太高 |
RX power low in lane x |
通道x接收到的光的功率太低 |
TX power high in lane x |
通道x发送的光的功率太高 |
TX power low in lane x |
通道x发送的光的功率太低 |
TX bias high in lane x |
通道x的偏置电流高 |
TX bias low in lane x |
通道x的偏置电流低 |
Temp high in lane x |
通道x的温度高 |
Temp low in lane x |
通道x的温度低 |
Transceiver info I/O error |
模块读写错误 |
Transceiver info checksum error |
模块信息校验和错误 |
Transceiver type and port configuration mismatched |
模块类型和端口配置不匹配 |
Transceiver type not supported |
端口不支持该类型的模块 |
# 显示接口Ten-GigabitEthernet3/0/45上插入的可插拔接口模块的当前故障告警信息。
<Sysname> display transceiver alarm interface ten-gigabitethernet 3/0/45
Ten-GigabitEthernet3/0/45 transceiver current alarm information:
RX power low
RX signal loss
表1-17 display transceiver alarm显示信息描述表
display transceiver diagnosis命令用来显示可插拔光模块的数字诊断参数的当前测量值。
display transceiver diagnosis interface [ interface-type interface-number ]
interface [ interface-type interface-number ]:显示接口上插入的可插拔光模块的数字诊断参数的当前测量值。interface-type interface-number表示接口类型和接口编号,如果不指定该参数,表示所有接口。
# 显示接口Ten-GigabitEthernet3/0/45上插入的可插拔光模块的数字诊断参数的当前测量值。
<Sysname> display transceiver diagnosis interface ten-gigabitethernet 3/0/45
Ten-GigabitEthernet3/0/45 transceiver diagnostic information:
Current diagnostic parameters:
Temp.(°C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
30 3.36 7.82 -35.64 -2.23
Alarm thresholds:
Temp.(°C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
High 73 3.80 13.20 1.00 0.00
Low -3 2.81 1.00 -9.50 -10.30
表1-18 display transceiver diagnosis显示信息描述表
数字诊断参数——温度,单位为°C,精确到1°C |
|
数字诊断参数——电压,单位为V,精确到0.01V |
|
数字诊断参数——偏置电流,单位为mA,精确到0.01mA |
|
数字诊断参数——接收光功率,单位为dBm,精确到0.01dBm |
|
数字诊断参数——发送光功率,单位为dBm,精确到0.01dBm |
|
display transceiver interface命令用来显示可插拔接口模块的主要特征参数。
display transceiver interface [ interface-type interface-number ]
interface-type interface-number:显示接口上插入的可插拔接口模块的主要特征参数。interface-type interface-number表示接口类型和接口编号,如果不指定该参数,表示所有接口。
# 显示接口Ten-GigabitEthernet3/0/45上插入的可插拔接口模块的主要特征参数。
<Sysname> display transceiver interface ten-gigabitethernet 3/0/45
Ten-GigabitEthernet3/0/45 transceiver information:
Transceiver Type : 10G_BASE_SR_SFP
Connector Type : LC
Wavelength(nm) : 850
Transfer Distance(m) : 80(OM2),20(OM1),300(OM3)
Digital Diagnostic Monitoring : YES
Vendor Name : FINISAR CORP.
表1-19 display transceiver interface命令显示信息描述表
· 光纤连接器包括SC(SC Connector,NTT公司推出的拔插锁紧式光纤连接器)、LC(LC Connector,Lucent公司推出的1.25mm/RJ45锁紧式光纤连接器)两种类型 · 其他连接器包括RJ-45、CX4等类型 |
|
· 光模块:显示发送激光中心波长,单位nm;对于支持多条不同波长光路的模块(例如10GBASE-LX4模块),各个波长值之间用逗号分隔 |
|
传输距离,xx为传输距离的单位,对于单模模块xx为km,对于其他模块xx为m。当模块支持多种传输介质时,各个传输距离值之间用逗号分隔。距离值后面括号里包含对应的“传输介质”。下面是各个介质的名称: · 9um:表示9/125um单模光纤 · 50um:表示50/125um多模光纤 · 62.5um:表示62.5/125um多模光纤 · TP:表示双绞线 · CX4:表示CX4电缆 |
|
· YES:表示支持数字诊断 · NO:表示不支持数字诊断 |
|
display transceiver manuinfo命令用于显示可插拔接口模块的部分电子标签信息。
display transceiver manuinfo interface [ interface-type interface-number ]
interface [ interface-type interface-number ]:显示接口上插入的可插拔接口模块的部分电子标签信息。interface-type interface-number表示接口类型和接口编号,如果不指定该参数,表示所有接口。
# 显示接口Ten-GigabitEthernet3/0/45上插入的可插拔接口模块的部分电子标签信息。
<Sysname> display transceiver manuinfo interface ten-gigabitethernet 3/0/45
Ten-gigabitethernet 3/0/45 transceiver manufacture information:
Manu. Serial Number : 213410A0000054000251
Manufacturing Date : 2012-09-01
Vendor Name : H3C
表1-20 display transceiver manuinfo命令显示信息描述表
display version命令用来显示系统版本信息。
# 查看系统版本信息。
<Sysname> display version
H3C Comware Software, Version 7.1.045, Release 7178
Copyright (c) 2004-2014 Hangzhou H3C Tech. Co., Ltd. All rights reserved.
H3C S12506-S uptime is 0 weeks, 0 days, 7 hours, 57 minutes
Last reboot reason : Cold reboot
Boot image: flash:/S12500-S-cmw710-boot-r7178.bin
Boot image version: 7.1.045, Release 7178
Compiled Jul 08 2014 16:07:02
System image: flash:/S12500-S-cmw710-system-r7178.bin
System image version: 7.1.045, Release 7178
Compiled Jul 08 2014 16:07:02
LPU 3:
Uptime is 0 weeks,0 days,7 hours,54 minutes
BOARD TYPE: LSXM1GT24PTSSE3
DRAM: 1024M bytes
FLASH: 0M bytes
NVRAM: 0K bytes
PCB 1 Version: VER.A
Bootrom Version: 001
CPLD 1 Version: 001
Release Version: H3C S12506-S-7178
Patch Version : None
Reboot Cause : ColdReboot
MPU(M) 7:
Uptime is 0 weeks,0 days,7 hours,57 minutes
BOARD TYPE: LSXM1MPU06B3
DRAM: 8192M bytes
FLASH: 1024M bytes
NVRAM: 1M bytes
PCB 1 Version: VER.A
Bootrom Version: 103
CPLD 1 Version: 000
CPLD 2 Version: 001
Release Version: H3C S12506-S-7178
Patch Version : None
Reboot Cause : ColdReboot
显示信息中的参数仅供参考,请以设备实际显示为准。
display version-update-record命令用来显示主用主控板启动软件包版本更新操作的记录。(独立运行模式)
display version-update-record命令用来显示全局主用主控板启动软件包版本更新操作的记录。(IRF模式)
设备启动时会记录当前使用的启动软件包版本信息,如果在运行过程中进行启动软件包版本更新操作,系统会记录该次更新的简要信息,包括升级时间和版本,以便管理员了解相关信息。设备重启这些记录也不会被删除。
目前最多可以保存10条更新记录。
# 显示设备启动软件包版本更新操作的记录。
<Sysname> display version-update-record
Name Version Compile time
Record 1 (updated on Aug 04 2014 at 17:42:04):
S12500-S-cmw710-boot-r7178.bin 7.1.045 Release 7178 Jul 08 2014 16:
07:02
S12500-S-cmw710-system-r7178.bin 7.1.045 Release 7178 Jul 08 2014 16:07:
02
Record 2 (updated on Jul 31 2014 at 09:42:59):
* S12500-S-cmw710-boot-r7178.bin 7.1.045 Release 7178 Jul 08 2014 16:
07:02
* S12500-S-cmw710-system-r7178.bin 7.1.045 Release 7178 Jul 08 2014 16:07:
02
…(略)
表1-21 display version-update-record命令显示信息描述表
最近的第n次更新的时间,Record 1为最新的一次更新 |
|
软件包的名称。带*符号,表示软件包的版本和升级前的版本有变化;不带*符号,表示版本没有变化 |
|
fabric-mode命令用来配置业务板槽位上的转发模式。
undo fabric-mode命令用来恢复缺省情况。
独立运行模式:
fabric-mode { compatible | standard | high-speed }
undo fabric-mode
IRF模式:
fabric-mode { compatible | standard | high-speed } chassis chassis-number
undo fabric-mode chassis chassis-number
【缺省情况】
设备工作在兼容模式。
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
compatible:将业务板槽位上的转发模式设置为兼容模式。
standard:将业务板槽位上的转发模式设置为标准模式。
high-speed:将业务板槽位上的转发模式设置为高速模式。
chassis chassis-number:设置指定成员设备的业务板槽位上的转发模式。chassis-number表示设备在IRF中的成员编号。(IRF模式)
【使用指导】
仅S12506-S支持该命令。
不同模式下,S12506-S业务板槽位支持的单板类型和槽位最大带宽不同,详见表1-22,用户可根据实际情况进行灵活配置。
业务板槽位上的转发模式 |
槽位限制 |
compatible |
S12506-S的Slot 4~5不支持以下业务板:OAP单板 |
standard |
S12506-S的业务板槽位不支持以下业务板:OAP单板 |
high-speed |
S12506-S的Slot 0~1不支持以下业务板: · SF系列接口板 · EC系列接口板 · SG系列接口板 · SE系列接口板 S12506-S的Slot 2~5不支持以下业务板:OAP单板 |
· 要使修改的业务板槽位上的转发模式生效,必须重启设备。
· 本命令仅在缺省MDC下支持。有关MDC的详细介绍,请参见“虚拟化技术配置指导”中的“MDC”。
· 关于OAP单板的详细介绍,请参见“OAA配置指导”中的“OAP单板”。
【举例】
# 将业务板槽位上的转发模式配置为标准模式。
[Sysname] fabric-mode standard
This command may need reboot the device. Continue? [Y/N]:y
Process OK.
【相关命令】
· display switch-mode status
fan prefer-direction命令用来配置PEX设备期望的风扇模块的风道方向。
undo fan prefer-direction命令用来恢复缺省情况。
【命令】
fan prefer-direction chassis chassis-number slot slot-number { power-to-port | port-to-power }
undo fan prefer-direction chassis chassis-number slot slot-number
【缺省情况】
PEX设备用户期望的风道方向为power-to-port,即电源侧进风、端口侧出风。
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
chassis chassis-number slot slot-number:表示PEX设备所在位置。chassis chassis-number表示PEX对应的虚拟框号。slot slot-number表示PEX设备对应的槽位号。(IRF模式)
power-to-port:表示设备期望的风道方向是电源侧进风、端口侧出风。
port-to-power:表示设备期望的风道方向是端口侧进风、电源侧出风。
【使用指导】
需要注意的是:
· 仅IRF模式下支持此命令。
· 此命令仅支持对以下PEX设备进行配置:S5120-28SC-HI、S6300系列交换机、S5130-HI系列交换机、S5130-EI系列交换机。
【举例】
# 配置虚拟框号为110,虚拟槽位号为0的PEX设备期望的风扇模块的风道方向为port-to-power。
<Sysname> system-view
[Sysname] fan prefer-direction chassis 110 slot 0 port-to-power
【相关命令】
· display fan
hardware-failure-detection命令用来配置当系统检测到硬件故障时自动采取的修复操作。
undo hardware-failure-detection命令用来恢复缺省情况。
【命令】
hardware-failure-detection { board | chip | forwarding } { isolate | off | reset | warning }
undo hardware-failure-detection { board | chip | forwarding }
【缺省情况】
当系统检测到器件(chip)、单板(board)和转发(forwarding)的硬件故障时,修复操作均为warning。
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
board:对单板故障进行在线检测,包括控制通道检测和单板状态快速检测。
chip:对器件故障进行在线检测,包括单板上各种器件(比如芯片、电容、电阻等)的检测。
forwarding:对转发层面的故障进行在线检测,包括业务自动检测和其他转发相关的检测。
isolate:检测到故障时,设备会自动关闭端口、隔离单板、禁止单板加载或给单板下电,从而尽量减小故障的影响。
off:检测到故障时,设备不进行任何操作。
reset:检测到故障时,设备会自动重启器件/单板以尝试修复故障。
warning:检测到故障时,设备发送Trap信息,不会修复故障。
【使用指导】
设备启动后,系统会持续自动检测器件、单板和转发的硬件故障。
【举例】
# 配置系统检测到器件故障时自动告警。
<Sysname> system-view
[Sysname] hardware-failure-detection chip warning
# 配置系统检测到单板故障时自动重启。
<Sysname> system-view
[Sysname] hardware-failure-detection board reset
header命令用来设置欢迎信息。
undo header命令用来关闭欢迎信息。
header { incoming | legal | login | motd | shell } text
undo header { incoming | legal | login | motd | shell }
incoming:设置Modem登录用户登录进入用户视图时的欢迎信息。如果要求认证,则欢迎信息在通过认证后输出。暂不支持通过Modem登录。
legal:设置登录终端界面前的授权信息,在输入认证用户名和密码前输出。
login:设置登录验证时的欢迎信息。
motd:设置登录终端界面前的欢迎信息。
shell:设置非Modem登录用户登录进入用户视图时的欢迎信息。
text:输入欢迎信息的内容。内容的输入支持单行和多行两种方式,具体输入规则请参见“基础配置指导”中的“设备管理”。
# 先后配置incoming、legal、login、motd和shell欢迎信息,并验证配置效果。
[Sysname] header incoming
Please input banner content, and quit with the character '%'.
Welcome to incoming(header incoming)%
[Sysname] header legal
Please input banner content, and quit with the character '%'.
Welcome to legal (header legal)%
[Sysname] header login
Please input banner content, and quit with the character '%'.
Welcome to login(header login)%
[Sysname] header motd
Please input banner content, and quit with the character '%'.
Welcome to motd(header motd)%
[Sysname] header shell
Please input banner content, and quit with the character '%'.
Welcome to shell(header shell)%
本例中,“%”为text的起始/结束字符,在显示文本后输入“%”表示文本结束,退出header命令。作为起始与结束字符,“%”不会成为所设置欢迎信息的一部分。
采用Telnet方式远程登录设备,测试以上设置(只有设置了登录认证之后,才会显示login欢迎信息)。
******************************************************************************
* Copyright (c) 2004-2014 Hangzhou H3C Tech. Co., Ltd. All rights reserved. *
* Without the owner's prior written consent, *
* no decompiling or reverse-engineering shall be allowed. *
******************************************************************************
Welcome to legal (header legal)
Press Y or ENTER to continue, N to exit.
Welcome to motd(header motd)
Welcome to login(header login)
Login authentication
Password:
Welcome to shell(header shell)
job命令用来为Schedule分配Job。
undo job命令用来将Job从Schedule中删除。
没有为Schedule分配Job。
Schedule视图
job-name:Job的名称,为1~47个字符的字符串,区分大小写。
多次执行该命令,可以为Schedule分配多个Job。多个Job在Schedule指定的时间同时执行,没有先后顺序。
分配的Job必须是设备上已经创建的Job,否则不能分配。Job可以通过scheduler job命令来创建。
# 为Schedule分配一个名称为save-job的Job。
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] job save-job
memory-threshold命令用来配置空闲内存告警的门限值。
undo memory-threshold命令用来恢复空闲内存告警的门限值。
undo memory-threshold [ slot slot-number [ cpu cpu-number ] ]
IRF模式:
undo memory-threshold [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
一级告警门限为96MB,二级告警门限为64MB,三级告警门限为48MB,系统恢复到正常的内存门限为128MB。
minor minor-value:一级告警门限,单位为兆字节(MB);minor-value应小于等于normal-value;为0则表示关闭该级门限告警功能。
severe severe-value:二级告警门限,单位为兆字节(MB);severe-value必须小于等于minor-value;为0则表示关闭该级门限告警功能。
critical critical-value:三级告警门限,单位为兆字节(MB);critical-value必须小于等于severe-value;为0则表示关闭该级门限告警功能。
normal normal-value:系统内存恢复正常状态时的内存大小,单位为兆字节(MB);normal-value必须小于等于实际内存大小。
slot slot-number:表示单板所在的槽位号,不指定该参数时,表示主用主控板。(独立运行模式)
chassis chassis-number slot slot-number:表示指定单板/PEX。chassis-number表示设备在IRF中的成员编号或者PEX对应的虚拟框号,slot-number表示单板/PEX所在的槽位号。不指定该参数时,表示全局主用主控板。(IRF模式)
cpu cpu-number:表示CPU编号。不指定该参数时,表示默认CPU。
系统实时监控系统剩余空闲内存大小,当条件达到时,就产生相应的告警/告警解除通知,以便通知关联的业务模块/进程采取相应的措施,以便最大限度的利用内存,又能保证设备的正常运行。
设备支持一级、二级、三级告警门限,关于这些告警门限的详细介绍请参见“基础配置指导”中的“设备管理”。
# 一级、二级、三级告警门限分别为64MB、48MB、32MB,当系统剩余空闲内存大于96MB时,恢复到正常状态。
[Sysname] memory-threshold minor 64 severe 48 critical 32 normal 96
· display memory-threshold
memory-threshold usage命令用来配置内存利用率阈值。
undo memory-threshold usage命令用来恢复缺省情况。
memory-threshold [ slot slot-number [ cpu cpu-number ] ] usage memory-threshold
undo memory-threshold [ slot slot-number [ cpu cpu-number ] ] usage
IRF模式:
memory-threshold [ chassis chassis-number slot slot-number [ cpu cpu-number ] ] usage memory-threshold
undo memory-threshold [ chassis chassis-number slot slot-number [ cpu cpu-number ] ] usage
memory-threshold:内存利用率阈值百分比,取值范围为0~100。
slot slot-number:表示单板所在的槽位号,不指定该参数时,表示主用主控板。(独立运行模式)
chassis chassis-number slot slot-number:表示指定单板/PEX。chassis-number表示设备在IRF中的成员编号或者PEX对应的虚拟框号,slot-number表示单板/PEX所在的槽位号。不指定该参数时,表示全局主用主控板。(IRF模式)
cpu cpu-number:设置单板的指定CPU的内存门限。cpu-number表示单板上CPU的编号。若没有设置该参数,表示设置的是默认的CPU。
系统每隔1分钟会对内存利用率进行采样,并将采样值和用户配置的内存利用率阈值比较。当采样值大时,则认为内存利用率过高,设备会发送Trap报文。
# 配置内存利用率阈值为80%。
[Sysname] memory-threshold chassis 1 slot 2 cpu 1 usage 80
monitor cpu-usage enable命令用来开启CPU利用率历史记录功能。
undo monitor cpu-usage enable命令用来关闭CPU利用率历史记录功能。
monitor cpu-usage enable [ slot slot-number [ cpu cpu-number ] ]
undo monitor cpu-usage enable [ slot slot-number [ cpu cpu-number ] ]
IRF模式:
monitor cpu-usage enable [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
undo monitor cpu-usage enable [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
CPU利用率历史记录功能处于开启状态。
slot slot-number:表示单板所在的槽位号,不指定表示主用主控板。(独立运行模式)
chassis chassis-number slot slot-number:表示指定单板/PEX。chassis-number表示设备在IRF中的成员编号或者PEX对应的虚拟框号,slot-number表示单板/PEX所在的槽位号。不指定表示全局主用主控板。(IRF模式)
cpu cpu-number:表示CPU编号。不指定该参数时,表示默认CPU。
开启CPU利用率历史记录功能后,系统会每隔一定时间(可通过monitor cpu-usage interval命令配置)对CPU的利用率进行采样,并把采样结果保存到历史记录区。这些记录可通过display cpu-usage history命令查看,以便用户监控设备近期的运行情况。
【举例】
# 打开CPU利用率历史记录功能。
[Sysname] monitor cpu-usage enable
· display cpu-usage configuration
monitor cpu-usage interval命令用来配置CPU利用率历史记录的采样周期。
monitor cpu-usage interval interval-value [ slot slot-number [ cpu cpu-number ] ]
IRF模式:
CPU利用率历史记录采样周期为1分钟。
interval-value:CPU利用率历史记录采用周期,取值为5Sec、1Min或者5Min。输入该参数时,请完整输入,否则,系统会提示参数错误。
slot slot-number:表示单板所在的槽位号,不指定表示主用主控板。(独立运行模式)
chassis chassis-number slot slot-number:表示指定单板/PEX。chassis-number表示设备在IRF中的成员编号或者PEX对应的虚拟框号,slot-number表示单板/PEX所在的槽位号。不指定表示全局主用主控板。(IRF模式)
cpu cpu-number:表示CPU编号。不指定该参数时,表示默认CPU。
开启CPU利用率历史记录功能后,系统会每隔一定时间(可通过monitor cpu-usage interval命令配置)对CPU的利用率进行采样,并把采样结果保存到历史记录区。这些记录可通过display cpu-usage history命令查看,以便用户监控设备近期的运行情况。
【举例】
# 配置CPU利用率历史记录的采样周期为5秒。
[Sysname] monitor cpu-usage interval 5Sec
· display cpu-usage configuration
monitor cpu-usage threshold命令用来配置CPU利用率阈值。
undo monitor cpu-usage threshold命令用来恢复缺省情况。
monitor cpu-usage threshold cpu-threshold [ slot slot-number [ cpu cpu-number ] ]
undo monitor cpu-usage threshold [ slot slot-number [ cpu cpu-number ] ]
IRF模式:
undo monitor cpu-usage threshold [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
CPU利用率阀值为99%。
cpu-threshold:CPU利用率阈值百分比,取值范围为0~100。
slot slot-number:表示单板所在的槽位号,不指定表示主用主控板。(独立运行模式)
chassis chassis-number slot slot-number:表示指定单板/PEX。chassis-number表示设备在IRF中的成员编号或者PEX对应的虚拟框号,slot-number表示单板/PEX所在的槽位号。不指定表示全局主用主控板。(IRF模式)
cpu cpu-number:表示单板上指定的CPU编号。
系统每隔1分钟会对CPU的利用率进行采样,并将采样值和用户配置的CPU利用率阈值比较。当采样值大时,则认为CPU利用率过高,设备会发送Trap报文。
# 配置CPU利用率阈值为80%。
<Sysname> system-view
[Sysname] monitor cpu-usage threshold 80
· display cpu-usage configuration
monitor handshake-timeout disable-port命令用于全局开启Port Down功能。
undo monitor handshake-timeout disable-port命令用于全局关闭Port Down功能。
monitor handshake-timeout disable-port
undo monitor handshake-timeout disable-port
【缺省情况】
缺省情况下,Port Down功能处于开启状态。
network-admin
mdc-admin
本功能常用于以主备方式提供网络可靠性的双机环境中(例如VRRP)。开启本功能后,当主设备的主控板被拔出或异常重启时,系统将立即关闭主设备上的所有业务口,使业务快速切换到备用设备上。
该功能配置成功后,只有当当前设备上已没有可用的主控板时才生效。
System View: return to User View with Ctrl+Z.
[Sysname] monitor handshake-timeout disable-port
reboot命令用来重启指定单板或整个设备。(独立运行模式)
reboot命令用来重启指定成员设备或所有成员设备。(IRF模式)
reboot [ slot slot-number [ subslot subslot-number ] ] [ force ]
IRF模式:
reboot [ chassis chassis-number [ slot slot-number [ subslot subslot-number ] ] ] [ force ]
chassis chassis-number:表示设备在IRF中的成员编号或者PEX对应的虚拟框号。(IRF模式)
slot slot-number:表示单板所在的槽位号。(独立运行模式)
slot slot-number:表示单板/PEX所在的槽位号。(IRF模式)
subslot subslot-number:接口子卡所在的子槽位号。该参数暂不支持。
force:强制重启:
· 不指定该参数时,重启设备,系统会做一些保护性检查(如启动文件是否存在,是否正在写磁盘等),若检查不通过则退出处理,不会重启设备;
· 如果主用启动文件损坏或者不存在,则不能通过reboot命令重启设备。此时,可以通过指定新的主用启动文件再重启。
· 如果设备在准备重启时,用户正在进行文件操作,为了安全起见,系统将不会执行此次重启操作。
· 使用force参数时,系统在重启时不会做任何保护性措施。重启后,可能导致文件系统损坏,请谨慎使用该参数。建议在系统故障或无法正常重启时,才使用该参数。
· 不指定slot参数,会导致整个设备重启。
· 指定slot参数,会重启指定单板。
(2) IRF模式:
· 不指定chassis和slot参数,则会重启所有成员设备和虚拟框。
· 只指定chassis不指定slot参数,则会重启IRF中指定的成员设备或者虚拟框。
· 同时指定chassis和slot参数,则会重启IRF中指定的单板或者PEX。
# 当配置没有变化时,重启设备。
Start to check configuration with next startup configuration file, please wait.........DONE!
This command will reboot the device. Continue? [Y/N]:y
Now rebooting, please wait...
# 当配置有变化时,重启设备,并选择保存配置文件。
Start to check configuration with next startup configuration file, please wait.........DONE!
Current configuration will be lost after the reboot, save current configuration? [Y/N]:y
Please input the file name(*.cfg)[flash:/startup.cfg]
(To leave the existing filename unchanged, press the enter key):
flash:/startup.cfg exists, overwrite? [Y/N]:y
Validating file. Please wait...
Configuration is saved to flash successfully.
This command will reboot the device. Continue? [Y/N]:y
Now rebooting, please wait...
# 当配置有变化时,重启设备,但不保存配置文件(。
Start to check configuration with next startup configuration file, please wait.........DONE!
Current configuration will be lost after the reboot, save current configuration? [Y/N]:n
This command will reboot the device. Continue? [Y/N]:y
Now rebooting, please wait...
# 强制重启设备。
A forced reboot might cause the storage medium to be corrupted. Continue? [Y/N]:y
Now rebooting, please wait...
# 重启接口板(接口板所在的槽位号为2)。(独立运行模式)
Start to check configuration with next startup configuration file, please wait..
.......DONE!
This command will reboot the specified slot, Continue? [Y/N]:y
Now rebooting, please wait...
# 强制重启接口板(接口板所在的槽位号为2)。(独立运行模式)
A forced reboot might cause the storage medium to be corrupted. Continue? [Y/N]:y
Now rebooting, please wait...
# 重启成员设备2。(IRF模式)
Start to check configuration with next startup configuration file, please wait..
.......DONE!
This command will reboot the specified chassis, Continue? [Y/N]:y
Now rebooting, please wait...
# 强制重启成员设备2。(IRF模式)
<Sysname> reboot chassis 2 force
A forced reboot might cause the storage medium to be corrupted. Continue? [Y/N]:y
Now rebooting, please wait...
# 重启成员设备2上的2号接口板。(IRF模式)
<Sysname> reboot chassis 2 slot 2
Start to check configuration with next startup configuration file, please wait..
.......DONE!
This command will reboot the specified slot, Continue? [Y/N]:y
Now rebooting, please wait...
# 强制重启成员设备2上的2号接口板。(IRF模式)
<Sysname> reboot chassis 2 slot 2 force
A forced reboot might cause the storage medium to be corrupted. Continue? [Y/N]:y
Now rebooting, please wait...
restore factory-default命令用来将设备恢复到出厂状态。
当设备使用场景更改,或者设备出现故障时,可以使用本命令来将设备恢复到出厂状态。执行该命令后,设备将只保留“.bin”软件包、MAC地址、电子标签等维持设备正常工作必需的信息,其它文件和参数均恢复到出厂状态,例如,设备存储介质根目录下的所有配置文件(即后缀为“.cfg”的文件)将被清除,设备在使用过程中生成的日志信息(即/logfile下的“.log”文件以及logbuffer中的信息)、Trap信息、Debug信息将被清除,BootWare菜单中各选项的值将恢复到缺省值等。请谨慎使用该命令。
# 将设备恢复到出厂状态。
<Sysname> restore factory-default
This command will restore the system to the factory default configuration and clear the operation data. Continue [Y/N]:y
Restoring the factory default configuration. This process might take a few minutes. Please wait..........................................................................................................Done.
Please reboot the system to place the factory default configuration into effect.
reset scheduler logfile命令用来清除Schedule日志文件的相关信息。
# 清除Schedule日志文件的相关信息。
<Sysname> reset scheduler logfile
reset asset-info命令用来清除设备的用户资产信息。使用该命令,用户可以清除设备机箱、单板、风扇框或电源模块的资产信息。
【命令】
独立运行模式
reset asset-info { chassis | fan fan-id | power power-id | slot slot-number } [ csn | custom | department | description | location | service-date | state ]
IRF模式:
reset asset-info chassis chassis-number { chassis | fan fan-id | power power-id | slot slot-number } [ csn | custom| department | description | location | service-date | state ]
【视图】
系统视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【参数】
chassis:清除设备机箱的用户资产信息。
fan fan-id:清除指定风扇框的用户资产信息。fan-id表示设备上风扇框的编号。
power power-id:清除指定电源模块的用户资产信息。power-id表示设备上电源模块的编号。
slot slot-number:清除指定单板的用户资产信息。slot-number表示设备上单板所在的槽位号。
csn:清除资产编号信息。
custom:清除用户自定义的资产信息。
department:清除资产的归属部门信息。
description:清除资产的描述信息。
location:清除资产的位置信息。
service-date:清除资产的启用时间信息。
state:清除资产的使用状态信息。
chassis chassis-number:清除指定成员设备的用户资产信息。chassis-number表示设备在IRF中的成员编号。(IRF模式)
清除指定电源模块的用户资产信息时,命令行只支持csn参数。
【描述】
reset asset-info命令用来清除设备的用户资产信息。使用该命令,用户可以清除设备机箱、单板、风扇框或电源模块的资产信息。
当用户希望清除设备机箱、单板或风扇框的具体信息项目(比如资产编号、资产描述信息等)时,只需要选择该信息项目对应的命令行参数;不选择具体信息项目对应的参数时,清除的是该设备机箱、单板或风扇框的所有用户资产信息。
使用该命令清除指定风扇框或者电源模块的资产信息时,如果设备上无对应编号的风扇框或者电源模块,将返回风扇框或者电源模块不在位的提示信息。
【举例】
# 清除设备上0号风扇框的资产编号信息。(独立运行模式)
<Sysname> system-view
[Sysname] reset asset-info fan 0 csn
# 清除1号成员设备上0号风扇框的资产编号信息。(IRF模式)
<Sysname> system-view
[Sysname] reset asset-info chassis 1 fan 0 csn
【相关命令】
· display asset-info
· set asset-info
reset version-update-record命令用来清除主用主控板启动软件包版本更新操作的记录。(独立运行模式)
reset version-update-record命令用来清除全局主用主控板启动软件包版本更新操作的记录。(-IRF模式)
# 清除设备启动软件包版本更新操作的记录。
[Sysname] reset version-update-record
This command will delete all records of version update. Continue? [Y/N]:y
· display version-update-record
scheduler job命令用来创建Job并进入Job视图。如果Job已创建,则直接进入Job视图。
undo scheduler job命令用来删除已创建的Job。
job-name:Job的名称,为1~47个字符的字符串,区分大小写。
一个Job可以被多个Schedule引用。Job视图下用户可以通过command命令为Job分配命令。
# 创建名称为backupconfig的Job并进入Job视图。
[Sysname] scheduler job backupconfig
[Sysname-job-backupconfig]
scheduler logfile size命令用来设置Schedule日志文件的大小。
Schedule日志文件的大小为16KB。
value:Schedule日志文件的大小,取值范围为16~1024,单位是KB。
Schedule日志文件用来记录Job下命令行的执行结果。如果该文件的大小超过了用户设置值,则系统会把老的记录删除,用来记录新的记录。如果要记录的日志信息超长,超过了日志文件的大小,则该日志超出的部分不会记录。
# 设置Schedule日志文件的大小为32KB。
[Sysname] scheduler logfile size 32
scheduler reboot at命令用来指定设备重启的具体时间和日期。
undo scheduler reboot命令用来取消定时重启设置。
scheduler reboot at time [ date ]
time:设备重启的时间,格式为HH:MM。HH代表小时,取值范围为0~23,MM代表分钟,取值范围为0~59。
date:设备重启的日期,格式为MM/DD/YYYY(月/日/年)或者YYYY/MM/DD(年/月/日)。
· YYYY的取值范围为2000~2035;
· MM的取值范围为1~12;
· DD的取值范围与具体月份有关。
如果没有指定date参数,并且:
· 设置的时间点在当前时间之后,则设备将在当天的该时间点重启;
· 设置的时间点在当前时间之前,则设备将在第二天的该时间点重启。
多次配置scheduler reboot at、scheduler reboot delay命令,最后一次执行的命令生效。
如果设备在准备重启时,用户正在进行文件操作,为了安全起见,系统将不会执行此次重启操作。
需要注意的是,该命令会使设备在将来的某个时间点重新启动,从而导致业务中断,请谨慎使用。
# 假设系统的当前时间为2011年6月6日11:43,设置设备在当天中午12:00重启。
<Sysname> scheduler reboot at 12:00
Reboot system at 12:00:00 06/06/2011 (in 0 hours and 16 minutes). Confirm? [Y/N]:
scheduler reboot delay命令用来配置重启设备的延迟时间。
undo scheduler reboot命令用来取消延时重启配置。
time:设备重启的等待时延,格式为HH:MM(小时:分钟)或MM(分钟)。
· 使用HH:MM格式时,MM的取值范围为0~59,HH:MM的最大长度为6个字符。
· 使用MM格式时,最大长度为6个字符。
如果设备在准备重启时,用户正在进行文件操作,为了安全起见,系统将不会执行此次重启操作。
多次配置scheduler reboot at、scheduler reboot delay命令,最后一次执行的命令生效。
需要注意的是,该命令会使设备在将来的某个时间点重新启动,从而导致业务中断,请谨慎使用。
# 假设系统的当前时间为2011年6月6日11:48,配置设备在88分钟后重启。
<Sysname> scheduler reboot delay 88
Reboot system at 13:16 06/06/2011(in 1 hours and 28 minutes). Confirm? [Y/N]:
scheduler schedule命令用来创建Schedule并进入相应的Schedule视图。如果Schedule已创建,则直接进入Schedule视图。
undo scheduler schedule命令用来删除指定Schedule。
scheduler schedule schedule-name
undo scheduler schedule schedule-name
schedule-name:Schedule的名字,为1~47个字符的字符串,区分大小写。
使用scheduler schedule命令可以配置定时执行任务,让设备在指定时间执行指定命令。
(1) 使用scheduler job命令创建Job。
(2) 在Job视图下,使用command命令配置需要执行的命令。
(3) 使用scheduler schedule命令创建Schedule。
(4) 在Schedule视图下,使用job命令为Schedule分配Job。一个Schedule下可以分配多个Job,但必须是已创建的Job,否则分配失败。
(5) 在Schedule视图下,使用user-role命令为Schedule配置用户角色。一个Schedule下最多可以分配64个角色。
(6) 在Schedule视图下,使用time at、time once或者time repeating命令来配置任务执行的时间。一个Schedule下只能设置一个执行时间。
# 创建名为saveconfig的Schedule。
[Sysname] scheduler schedule saveconfig
· time once
set asset-info命令用来设置设备的用户资产信息。使用该命令,用户可以根据自定义的规则为设备机箱、单板、风扇框及电源模块设置资产信息。
set asset-info { chassis | fan fan-id | power power-id | slot slot-number } { csn csn-number | custom name value | department department | description description | location location | service-date date | state state }
set asset-info chassis chassis-number { chassis | fan fan-id | power power-id | slot slot-number } { csn csn-number | custom name value | department department | description description | location location | service-date date | state state }
network-admin
network-operator
mdc-admin
mdc-operator
fan fan-id:设置指定风扇框的用户资产信息。fan-id表示设备上风扇框的编号。
power power-id:设置指定电源模块的用户资产信息。power-id表示设备上电源模块的编号。
slot slot-number:设置指定单板的用户资产信息。slot-number表示设备上单板所在的槽位号。
csn csn-number:设置资产编号信息。csn-number表示用户设置的资产编号信息,为1~64字节的字符串。
custom name value:设置用户自定义的资产信息。name表示用户自定义的资产信息名称,value表示用户设置的资产信息内容。
department department:设置资产的归属部门信息。department表示用户设置的资产归属部门,为1~64字节的字符串。
description description:设置资产的描述信息。description表示用户设置的资产描述信息,为1~64字节的字符串。
location location:设置资产的位置信息。location表示用户设置的资产位置信息,为1~64字节的字符串。
service-date date:设置资产的启用时间信息。date表示用户设置的资产启用时间,为1~25字节的字符串。
state state:设置资产的使用状态信息。state表示用户设置的资产使用状态,为1~64字节的字符串。
chassis chassis-number:设置指定成员设备的用户资产信息。chassis-number表示设备在IRF中的成员编号。(IRF模式)
使用该命令设置指定风扇框或者电源模块的资产信息时,如果设备上无对应编号的风扇框或者电源模块,将返回风扇框或者电源模块不在位的提示信息。
# 设置设备上0号风扇框的资产编号为123456。(独立运行模式)
[Sysname] set asset-info fan 0 csn 123456
# 设置1号成员设备上0号风扇框的资产编号为123456。(IRF模式)
[Sysname] set asset-info chassis 1 fan 0 csn 123456
【相关命令】
· display asset-info
· reset asset-info
shutdown-interval命令用来配置端口状态检测定时器的时长。
undo shutdown-interval命令用来恢复缺省情况。
time:端口状态检测定时器的时长,取值范围为0~300,单位为秒。取值为0时,表示不进行定时检测。
某些协议模块在特定情况下会自动关闭某个端口,比如当开启了BPDU保护功能的端口收到配置消息时,MSTP协议模块将自动关闭该端口。同时,系统会启动一个检测定时器,如果直到定时器超时(即经过time秒之后),该端口仍处于关闭状态,协议模块则自动激活该端口,令其恢复到真实的物理状态。
需要注意的是,如果用户在端口定时检测过程中将检测时间间隔修改为T1,修改时刻距协议关闭端口时间间隔为T。若T<T1,则被关闭的端口会再经过T1-T时间后被恢复;若T>=T1,则被关闭的端口会立即恢复。例如当前time设置为30,当端口被协议模块关闭2秒(T=2)后,修改time为10(T1=10),则该接口会再经过8秒后被恢复;如果当前time为30,端口被协议模块关闭10秒后,修改time为2,则该端口会立即恢复。
# 配置端口状态检测定时器的时长为100秒。
[Sysname] shutdown-interval 100
switch-fabric isolate命令用来将网板从转发平面隔离出去,所有数据流量都不经过指定网板。
undo switch-fabric isolate命令用来恢复缺省情况。
【命令】
独立运行模式:
switch-fabric isolate slot slot-number
undo switch-fabric isolate slot slot-number
IRF模式:
switch-fabric isolate chassis chassis-number slot slot-number
undo switch-fabric isolate chassis chassis-number slot slot-number
【缺省情况】
网板处于转发平面,数据流量会经过网板进行转发。
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
slot slot-number:表示网板所在的槽位号。(独立运行模式)
chassis chassis-number slot slot-number:表示指定成员设备上的指定网板。(IRF模式)
【使用指导】
· 本命令不支持对主控板进行隔离。
· 设备上仅存在一块网板时,请不要使用本命令隔离该网板。
· 配置某块网板的隔离功能后,如果该网板不需要再使用,请及时拔出该网板;如果该网板需要继续使用,请使用undo switch-fabric isolate命令对该网板取消隔离并重启该网板,并且在网板隔离期间请不要重启设备。
· 配置该功能后主控板与网板的正常通信,控制平面上协议报文的解析与协议的计算等功能均不受影响,从而保证了通过undo switch-fabric isolate 命令快速恢复网板的转发能力。
· 每块网板都有一定的转发带宽,隔离一块网板后会减少相应的转发带宽,使设备整体转发带宽降低。
【举例】
# 将10号槽位网板隔离。
<Sysname> system-view
[Sysname] switch-fabric isolate slot 10
The command will isolate the switch fabric from the system. Continue? [Y/N]y
# 将1号成员设备的10号槽位网板隔离。
<Sysname> system-view
[Sysname] switch-fabric isolate chassis 1 slot 10
The command will isolate the switch fabric from the system. Continue? [Y/N]y
【相关命令】
· switch-fabric removal-signal-suppression
switch-fabric removal-signal-suppression命令用来抑制网板移出前向系统上报中断信号。
undo switch-fabric removal-signal-suppression命令用来恢复缺省情况。
【命令】
switch-fabric removal-signal-suppression
undo switch-fabric removal-signal-suppression
【缺省情况】
网板移出前会向系统上报中断信号。
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
无
【使用指导】
为了避免因网板频繁误报中断信号而导致设备异常,可以配置网板移出信号抑制功能。
【举例】
#配置网板移出信号抑制功能。
<Sysname> system-view
[Sysname] switch-fabric removal-signal-suppression
【相关命令】
· switch-fabric isolate
switch-mode命令用于配置交换机业务板的工作模式。
undo switch-mode命令用于恢复业务板的工作模式为未配置状态。
【命令】
独立运行模式:
switch-mode { acl-ipv4 | acl-l2 | bridging | high-speed | ipv6 | low-speed | routing | mix-bridging-routing | normal | standard-ipv6 | port-extender } slot slot-number
undo switch-mode slot slot-number
IRF模式:
switch-mode { acl-ipv4 | acl-l2 | bridging | high-speed | ipv6 | low-speed | routing | mix-bridging-routing | normal | standard-ipv6 | port-extender } chassis chassis-number slot slot-number
undo switch-mode chassis chassis-number slot slot-number
【缺省情况】
表1-23 业务板的缺省工作模式
接口板 |
缺省的接口板工作模式 |
EC系列接口板 SG系列接口板 SE系列接口板 |
mix-bridging-routing |
SF系列接口板 |
normal |
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
acl-ipv4:acl-ipv4模式。本参数暂不支持。
acl-l2:acl-l2模式。本参数暂不支持。
high-speed:高速模式。本参数暂不支持。
ipv6:IPv6模式。
low-speed:低速模式。本参数暂不支持。
bridging:MAC扩展模式。
normal:普通模式。
routing:路由扩展模式。
mix-bridging-routing:混合扩展模式。
standard-ipv6:IPv6标准模式。
port-extender:端口扩展模式。设备目前暂不支持。
slot slot-number:业务板所在槽位号。
chassis chassis-number:表示IRF中设备的成员编号。(IRF模式)
【使用指导】
业务板工作模式配置完毕后需保存配置并重启该业务板,所做配置才会生效。
【举例】
# 配置设备2号槽位EC系列接口板的工作模式为MAC扩展模式(bridging)。(独立运行模式)
<Sysname> system-view
[Sysname] switch-mode bridging slot 2
# 配置1号成员设备上2号槽位EC系列接口板的工作模式为MAC扩展模式(bridging)。(IRF模式)
<Sysname> system-view
[Sysname] switch-mode bridging chassis 1 slot 2
【相关命令】
· display switch-mode status
sysname命令用来设置设备的名称。
undo sysname用来恢复缺省情况。
sysname:设备名称,为1~64个字符的字符串。
设备的名称对应于命令行接口的提示符,如设备的名称为Sysname,则用户视图的提示符为<Sysname>。
# 设置设备的名称为R2000。
[Sysname] sysname R2000
system-working-mode命令用来配置设备的工作模式。
undo system-working-mode命令用来恢复缺省情况。
system-working-mode { advance | standard }
advance:将设备的工作模式设置为高级模式。
standard:将设备的工作模式设置为标准模式。
· SF系列接口板
· EC系列接口板
· SG系列接口板
· SE系列接口板
不同模式下设备支持的特性不同,或者相同的特性支持的规格不同,请根据实际需要配置。例如只有当设备工作在高级模式下才支持配置FCoE功能。
需要注意的是,系统工作模式切换到advance时,需要预留足够的IFP ACL资源,否则会导致切换失败。可以使用display qos-acl resource命令查看当前剩余的IFP ACL资源。有关display qos-acl resource命令的介绍,请参见“ACL和QoS”中的“ACL”。
# 将设备工作模式配置为高级模式。
[Sysname] system-working-mode advance
The system working mode is changed, it will take effect after system restart.
temperature-limit命令用于设置设备的温度告警门限。
undo temperature-limit命令用来恢复缺省情况。
undo temperature-limit slot slot-number { hotspot | inflow | outflow } sensor-number
IRF模式:
单板的缺省温度告警门限可以在配置本功能前通过display environment命令查看。
chassis chassis-number:表示设备在IRF中的成员编号。(IRF模式)
slot slot-number:配置指定单板上温度传感器的温度门限。slot-number表示单板所在的槽位号。
hotspot:配置热点传感器的温度门限。热点传感器一般置于发热量较大的芯片附近,监测芯片温度。
inflow:配置入风传感器的温度门限。入风传感器一般置于入风口附近,监测环境温度。
outflow:配置出风传感器的温度门限。出风传感器一般置于出风口附近,监测设备温度。
sensor-number:温度传感器的编号,取值为从1开始的正整数,每一个数字对应设备(单板)上的一个温度传感器。
lowlimit:低温告警门限,单位为摄氏度。
warninglimit:一般级(Warning)高温告警门限,单位为摄氏度。一般级高温告警门限必须大于低温告警门限。
alarmlimit:严重级(Alarm)高温告警门限,单位为摄氏度。严重级高温告警门限必须大于一般级高温告警门限。
· 不同单板的温度告警门限取值范围不同,输入温度告警门限值时请通过<?>查看设备提示信息,以获取温度告警门限的取值范围。
· 如果温度低于低温告警门限,系统会生成日志信息和告警信息提示用户。
· 如果温度高于Warning高温门限,系统会生成日志信息和告警信息提示用户。
· 如果温度高于Alarm高温门限,系统一方面通过反复打印日志信息和告警信息提示用户,另一方面还会通过设备面板上的指示灯来告警。
# 配置7号单板上1号热点传感器,低温门限为-5摄氏度,Warning级高温门限为80摄氏度,Alarm级高温门限为95摄氏度。(独立运行模式)
[sysname] temperature-limit slot 7 hotspot 1 -5 80 95
# 配置1号成员设备7号单板上1号热点传感器,低温门限为-5摄氏度,Warning级高温门限为80摄氏度,Alarm级高温门限为95摄氏度。(IRF模式)
[sysname] temperature-limit chassis 1 slot 7 hotspot 1 -5 80 95
time at命令用来配置在指定时刻执行Schedule。
undo time命令用来为Schedule取消执行时间配置。
没有为Schedule配置执行时间。
Schedule视图
time:Schedule的执行时间,格式为HH:MM(小时:分钟)。HH取值范围为0~23,MM取值范围为0~59。
date:Schedule执行的日期,格式为MM/DD/YYYY(月/日/年)或者YYYY/MM/DD(年/月/日)。
· YYYY的取值范围为2000~2035;
· MM的取值范围为1~12;
· DD的取值范围与具体月份有关。
一个Schedule只能配置一个执行时间。因此,同一Schedule视图下,多次执行time at、time once或time repeating命令时,最新配置生效。
# 配置2011年5月11日1点1分执行名称为saveconfig的Schedule。
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] time at 1:1 2011/05/11
time once命令用来为Schedule配置执行时间。
undo time命令用来为Schedule取消执行时间配置。
time once at time [ month-date month-day | week-day week-day&<1-7> ]
没有为Schedule配置执行时间。
Schedule视图
at time:Schedule的执行时间,格式为HH:MM(小时:分钟)。HH取值范围为0~23,MM取值范围为0~59。
month-date month-day:Schedule在一个月中的哪天被执行。month-day表示日期,取值范围为1~31。如果指定了一个本月不存在的日期,则实际生效的时间为下一个月的该日期,比如,二月没有30号,则实际生效的时间为三月的30号。
week-day week-day&<1-7>:Schedule在一周中的哪(些)天被执行。week-day&<1-7>表示一周中任一天或几天的组合,week-day取值为:Mon、Tue、Wed、Thu、Fri、Sat、Sun,&<1-7>表示前面的参数最多可以输入7次。设置多天时,字符串之间用空格分开。
delay time:指定Schedule延迟执行的时间。格式为HH:MM(小时:分钟)或MM(分钟)。
· 使用HH:MM格式时,MM的取值范围为0~59,HH:MM最大长度为6个字符。
· 使用MM格式时,最大长度为6个字符。
配置该命令后,Schedule在该设定时间点到达时执行,若当天/本月/本周该时间点已过去,则顺延到第二天/下月/下周。执行后下次再到达该时间点时Schedule不再执行。
一个Schedule只能配置一个执行时间。因此,同一Schedule视图下,多次执行time at、time once或time repeating命令时,最新配置生效。
# 当天的15点执行名称为saveconfig的Schedule。
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] time once at 15:00
# 最近到达的15号的15点执行名称为saveconfig的Schedule。
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] time once at 15:00 month-date 15
# 最近一个周一和周五的12点整执行名称为saveconfig的Schedule。
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] time once at 12:00 week-day mon fri
# 延迟10分钟执行名称为saveconfig的Schedule。
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] time once delay 10
time repeating命令用来配置重复执行Schedule的时间。
undo time命令用来为Schedule取消执行时间配置。
time repeating [ at time [ date ] ] interval interval-time
time repeating at time [ month-date [ month-day | last ] | week-day week-day&<1-7> ]
没有配置重复执行Schedule的时间。
Schedule视图
at time:表示重复执行的时间,格式为HH:MM(小时:分钟)。HH取值范围为0~23,MM取值范围为0~59。不指定该参数时,表示从现在开始。
date:指定Schedule重复执行的开始日期,格式为MM/DD/YYYY(月/日/年)或者YYYY/MM/DD(年/月/日)。不指定该参数时,表示将来第一次到达time的时间点的日期。
· YYYY的取值范围为2000~2035;
· MM的取值范围为1~12;
· DD的取值范围与具体月份有关。
interval interval-time:指定重复执行的时间间隔。格式为HH:MM(小时:分钟)或MM(分钟)。
· 使用HH:MM格式时,MM的取值范围为0~59,最大长度为6个字符。
· 使用MM格式时,取值的最小值为1,最大长度为6个字符。
month-date [ month-day | last ]:表示每月中的某一天。其中,month-day表示日期,取值范围为1~31。如果指定了一个本月不存在的日期,则实际生效的时间为下一个月的该日期,比如,二月没有30号,则实际生效的时间为三月的30号。last表示每月的最后一天。
week-day week-day&<1-7>:表示每周中的某(些)天。week-day&<1-7>表示一周中任一天或几天的组合,week-day取值为:Mon、Tue、Wed、Thu、Fri、Sat、Sun,&<1-7>表示前面的参数最多可以输入7次。设置多天时,字符串之间用空格分开。
time repeating [ at time [ date ] ] interval interval-time表示从指定时间开始,周期性执行Schedule。
time repeating at time [ month-date [ month-day | last ] | week-day week-day&<1-7> ]表示每月/每周的某(些)天重复执行Schedule。
一个Schedule只能配置一个执行时间。因此,同一Schedule视图下,多次执行time at、time once或time repeating命令时,最新配置生效。
# 配置从早上八点开始,每隔1小时执行一次名称为saveconfig的Schedule。
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] time repeating at 8:00 interval 60
# 配置从现在开始每天的12:00执行名称为saveconfig的Schedule。
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] time repeating at 12:00
# 配置从现在开始每个月5号的上午8点执行名称为saveconfig的Schedule。
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] time repeating at 8:00 month-date 5
# 配置从现在开始每个月的最后一天8点执行名称为saveconfig的Schedule。
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] time repeating at 8:00 month-date last
# 配置从现在开始每个周五和周六的上午8点执行名称为saveconfig的Schedule。
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] time repeating at 8:00 week-day fri sat
transceiver phony-alarm-disable命令用来关闭可插拔模块告警信息开关。
undo transceiver phony-alarm-disable命令用来恢复缺省情况。
【命令】
transceiver phony-alarm-disable
undo transceiver phony-alarm-disable
【缺省情况】
可插拔模块告警信息开关处于开启状态。
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【使用指导】
当设备上插入的光模块的生产或定制厂商不是H3C时,设备会不停打印Trap和Log信息提醒用户,要求用户更换成H3C的光模块,以便管理和维护光模块。而H3C早期销售的光模块,可能没有记录厂商信息,但为了保护用户投资,这样的光模块还需要能继续正常使用。此时,可以关闭可插拔模块告警信息开关,停止输出相关告警信息。
本命令仅在缺省MDC下支持。有关MDC的详细介绍,请参见“虚拟化技术配置指导”中的“MDC”。
【举例】
# 关闭可插拔模块告警信息开关。
<Sysname> system-view
[Sysname] transceiver phony-alarm-disable
user-role命令用来配置执行Schedule的定时任务时使用的用户角色。
undo user-role命令用来将已经配置的用户角色从Schedule中删除。
Schedule执行定时任务时使用的用户角色,为创建该Schedule的用户的用户角色。
Schedule视图
role-name:执行定时任务时使用的用户角色,为1~63个字符的字符串,区分大小写。可以是系统预定义的角色名称,包括network-admin、network-operator、mdc-admin、mdc-operator、level-0~level-15,也可以是自定义的用户角色名称。
设备支持的每条命令执行时都需要相应的用户角色。只有本命令中配置的用户角色具有权限,Schedule中的command命令中指定的命令行才能执行。关于用户角色的详细描述请参见“基础配置指导”中的“RBAC”。
同一Schedule最多可配置64个用户角色,超过该上限后,新配置会执行失败。
# 配置执行定时任务test时使用的用户角色为rolename。
[Sysname] scheduler schedule test
[Sysname-schedule-test] user-role rolename
不同款型规格的资料略有差异, 详细信息请向具体销售和400咨询。H3C保留在没有任何通知或提示的情况下对资料内容进行修改的权利!